Advanced Search

Amendments To The Cabinet Of Ministers Of 9 July 2013 Regulation No 383 Of The "rules For The Building Of The Energosertifikācij"

Original Language Title: Grozījumi Ministru kabineta 2013. gada 9. jūlija noteikumos Nr. 383 "Noteikumi par ēku energosertifikāciju"

Subscribe to a Global-Regulation Premium Membership Today!

Key Benefits:

Subscribe Now for only USD$40 per month.
Cabinet of Ministers Regulations No. 643 in Riga 2015 10 November (pr. No. 58 1) amendments to the Cabinet of Ministers of 9 July 2013 the Regulation No 383 "rules for building energosertifikācij" Issued in accordance with the law of the energy performance of buildings the third subparagraph of article 7, article 8 of the eighth, the fifth paragraph of article 9, the third paragraph of article 10, article 11 the third paragraph do cabinet 9 July 2013 the Regulation No 383 "rules for building energosertifikācij ' (Latvian journal, 13, nr. 138.) the following amendments : 1. Replace the text, the word "compensated" (fold) with the word "pārbūvējam" (the fold). 2. Replace the text of the provisions, the word "renovējam" (the fold) with the word "renewable" (fold). 3. Replace the text, the words "technical system" (fold) with the words "engineering systems" (fold). 4. Replace the text of the provisions, the word "type" (fold) with the word "type" (fold). 5. Express 3.3 subparagraph by the following: "3.3. based on the estimates and the actual results of construction, placing in service, construction of temporary buildings produce energy performance certificates are issued." 6. Express 4.1. subparagraph by the following: "4.1. building construction or building cadastral trying thing;". 7. Replace the words in point 4.11. "energy audit" with the words "energy efficiency rating, heating system". 8. Make 6.1.1. subparagraph by the following: "6.1.1. various types of building or divdzīvokļ viendzīvokļ building;". 9. Express 6.3. subparagraph by the following: "6.3. This provision paragraph 6 of annex 1 or Annex 2 paragraph 6 in the" last year of renovation/restoration "indicates the last year when rebuilding or reconstruction work in the affected building facade or influenced the building energy efficiency indicators". 10. Express 6.4.1. subparagraph by the following: "6.4.1. reference values indicate almost zero energy building, according to the building regulations, as well as building type corresponding to the average consumption, if the building falls within any of the rules referred to in point 16;". 11. Delete 6.4.2.6.4.3 and 6.4.4.,. 12. Replace paragraph 7.2 "23." with the number "24". 13. Make paragraph 9 by the following: "9. the independent expert building or temporary dissemination dissemination is recorded in the register of the dissemination of buildings." 14. Add to paragraph 11 after words "heating system" with the words "boilers". 15. Make the following paragraph 13: "13. building energy benchmarking system consists of building energy efficiency indicators, the comparison of heating consumption represented by the comparative evaluation scale in accordance with the provisions of the annex." 16. Make 14.1. and 14.2. subparagraph by the following: "14.1. residential buildings: 14.1.1. Class A – energy efficiency indicator heating not exceeding 40 kWh per square meter per year; 14.1.2. Class B – energy efficiency indicator for heating more than 40 kWh per square meter per year, but not more than 60 kWh per square meter per year; 14.1.3. C class – energy efficiency indicator for heating more than 60 kWh per square meter per year but does not exceed 80 kWh per square meter per year; 14.1.4. Class D – energy efficiency indicator for heating exceeds 80 kWh per square meter per year, but less than 100 kWh per square meter per year; 14.1.5. E class-energy efficiency indicator for heating exceeds 100 kWh per square meter per year, but not more than 150 kWh per square meter per year; 14.1.6. F-energy efficiency class indicator for heating more than 150 kWh per square meter per year, the building requires energy efficiency improvement measures; 14.2. non-residential buildings: 14.2.1 A class – energy efficiency indicator heating not exceeding 45 kWh per square meter per year; 14.2.2. Class B – energy efficiency indicator for heating exceeds 45 kWh per square meter per year but no greater than 65 kWh per square meter per year; 14.2.3. C class – energy efficiency indicator for heating more than 65 kWh per square meter per year, but not exceeding 90 kWh per square meter per year; 14.2.4. Class D – energy efficiency indicator for heating exceeds 90 kWh per square meter per year, but not more than 110 kWh per square meter per year; 14.2.5. E class-energy efficiency indicator for heating more than 110 kWh per square meter per year, but not more than 150 kWh per square meter per year; 14.2.6. F-energy efficiency class indicator for heating more than 150 kWh per square meter per year, the building requires energy efficiency measures. " 17. Supplement with 15.1, 15.2, 15.3 and 15.4 points as follows: "15.1 of the energy performance of buildings on the minimum level of new construction set in annex 5 of these regulations, taking into account the construction of the building plans approval date. 15.2 building energy efficiency minimum levels of renewable or pārbūvējam buildings: 15.2 1. multi-family residential buildings-energy efficiency indicator heating not exceeding 90 kWh per square meter per year; 15.2 2. different types of viendzīvokļ and divdzīvokļ residential buildings-energy efficiency indicator heating not exceeding 100 kWh per square meter per year; 15.2 non-residential buildings-energy efficiency indicator heating not exceeding 110 kWh per square meter per year. 15.3 If the average heated area of a building to a height greater than 3.5 metres, building energy efficiency minimum levels may exceed this rules 15.1 and 15.2 points in these indicators. Taking into account the average heated area of a building heights, building energy efficiency minimum level of heating is calculated using the following formula: Emin. Apr. = Emin. x h/3.5 that Emin. Apr. -the energy performance of buildings minimum level, if the average heated area of a building shall exceed the height of 3.5 meters (kWh/m2 per year); h-actual average heated area of the building height (m); Emin. -the energy performance of buildings minimum level according to this provision, or 15.2 points 15.1 (kWh/m2/year). 15.4 the energy performance of buildings, the minimum permissible level of new construction, renewable or pārbūvējam buildings shall not apply if this requirement is not technically or functionally possible or if the cost-benefit analysis for the life of the building indicate a loss. " 18. Express 17.1. subparagraph by the following: "17.1. building energy performance indicator corresponds to A class for heating, while ensuring compliance with the regulations of the indoor climate requirements, hygiene and construction work in the area of defence;". 19. Amend paragraph 29. 20. Make 30 and 31 by the following: "9.30. This provision and paragraph 28 shall apply on 1 January 2016. 31. Existing dissemination and temporary buildings, as well as the dissemination of heating system and air conditioning inspection provisions, issued by 2015. December 31, the independent expert is recorded in the register of the dissemination of buildings up to 30 June 2016. " 21. Put 1, 2, 3, 4 and 5 of the annex as follows: "annex 1 Cabinet 9 July 2013 the Regulation No 383 1. page notes. 1 building energy efficiency class in accordance with the assessment of the consumption of the building heating. 2 building assessment of consumption, kWh/m2 per year for heating. 3 document properties "date" and "signature" does not fill in, if the document has been prepared according to the law on electronic document design. 2. page

9. the buildings delimiting the specific design of the heat loss coefficient of HT/Aapr ___ ___ ___ W/(m2K) HT/Aapr ___ ___ ___ W/(m2K) HT and HT-actual and statutory construction limiting the building heat loss coefficient, calculated in accordance with the laws and regulations in the field of construction 10. The building's distinctive ventilation heat loss coefficient of HVE/Aapr ___ ___ ___ W/(m2K) HV – building ventilation heat loss coefficient, calculated in accordance with building energy efficiency calculation method of ventilation heat loss recovery heating period _____ _____% 11. Energy accounting and distribution of heating and hot water systems in the Energonesēj calendar year for heating hot water supply the name of the listed quantity kWh climate adjustments, kWh5 kWh/m2 per year kWh kWh/m2 year ___ 4 kWh 12. Attachments and attached documents (document name, date, number, and page number): 1) overview of the economic energy efficiency based on enhancing measures that implementation costs are cost effective future (planned) lifetime; 2) annex, which contains the used input values, specifying the type of data acquisition and data source; 3) _____________ 4) .. 13. the independent expert's certificate Certifying that the building is drawn up the dissemination, by preventing the action of my own, the Subscriber or any other person's interest could reduce the accuracy of the results obtained, the objectivity and reliability of the assessment. _ _ _ _ _ _ _ _ _ _ _ _ _ (datums6) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ (name) ___ ___ ___ ___ ___ ___ (paraksts6) notes. 4 data for infact energonesēj listed for the last five years or seasons actually listed the units (t, m3, MJ, kcal, or other). 5 climate correction factor for the heating season consumption, regulations for the normalisation of heating degree days. 6 document properties "date" and "signature" does not fill in, if the document has been prepared according to the law on electronic document design. 2. the annex to Cabinet of Ministers of 9 July 2013 the Regulation No 383 1. page notes. 1 building energy efficiency class in accordance with the assessment of the consumption of the building heating. 2 building assessment of consumption, kWh/m2 per year for heating. 3 document properties "date" and "signature" does not fill in, if the document has been prepared according to the law on electronic document design. 2. page 9. News about the acceptance into service of the building (completed after the commissioning of the building): _____ date ____ _____ ____ 10. Building construction specific limiting heat loss coefficient of HT/Aapr ___ ___ ___ W/(m2K) HT/Aapr ___ ___ ___ W/(m2K) HT and HT-actual and statutory construction limiting the building heat loss coefficient, calculated in accordance with the laws and regulations in the field of construction 11. The building's distinctive ventilation heat loss coefficient of HVE/Aapr ___ ___ ___ W/(m2K) HV – building ventilation heat loss coefficient, calculated in accordance with building energy efficiency calculation method of ventilation heat loss recovery heating period _____ _____% 12. Attachments and attached documents (document name, date, number, and page number): Annex 1), containing the input values used to indicate the type of data acquisition and data source; 2) _____________ 3) .. 13. the independent expert's certificate Certifying that the building is drawn up temporary dissemination, by preventing the action of my own, the Subscriber or any other person's interest could reduce the accuracy of the results obtained, the objectivity and reliability of the assessment. _ _ _ _ _ _ _ _ _ _ _ _ _ (date) _____ _____ _____ _____ _____ ___ (name) ___ ___ ___ ___ ___ ___ (paraksts4) Note. 4 document properties "date" and "signature" does not fill in, if the document has been prepared according to the law on electronic document design. 3. the Cabinet of Ministers of 9 July 2013 the Regulation No 383 overview of economically justified energy efficiency enhancing measures that implementation costs are cost effective future (planned) lifetime of building 1 type [in accordance with Cabinet of Ministers July 9, 2013 No. 383 of the provisions of the "rules for the building of the energosertifikācij" section 6.1] 2. address [Street, building, village, County or city areas, city, municipality, County, postal code] 3. Part of a building [indicates If it relates to a part of the building] 4. building or its part (space group) cadastral designation [XXXX XXX XXXX XXX XXX] 5. Proposals for improving the energy performance of the building proposals fill in the free-form, subject to the following conditions: 1) include proposals on measures that are technically feasible for the specific building; 2) indicated the proposed measure, its description and achievable, showing the desired unit of measure; 3) indicates the proposed measure planned energy savings delivered, specific energy savings to building one square meter per year and percentage of savings (from the existing building energy efficiency calculated estimate); 4) indicates the proposal planned implementation costs (you can also specify the measures the payback period); 5) if building the proposal increases or decreases the other energy consumption, the consumption separately with the appropriate positive or negative sign; 6) proposals are numbered. If you are offered an alternative proposal, the variant represents (for example, 1A, 1B, 1 c) and, if necessary, explain, to be able to identify with whom or which other measures they are comparable and interact.
 
6. building energy efficiency indicators and comparison of the improvement recommendation of options (specify the relevant section of this report proposed measures 5 numbers or labels) version 1 version 2 indicators measure the measured figures without correction Calculated indicators indicators to be achieved (after the implementation of the proposal) 6.1. building construction specific limiting heat loss coefficient of HT/W/(m2K) Aapr 6.2. Buildings ventilation heat loss coefficient specific HVE/Aapr 6.2.1. Heat Recovery% 6.3. air exchange rate m3/(h × m2) 6.4. required energy evaluation kWh/m2 year: t. see   6.4.1. heating 6.4.1.1. heating indicator to measure climate adjustment 6.4.2. hot water system for ventilation 6.4.3.6.4.4 6.4.5. illumination cooling 6.4.6. additional reduction% 6.5. heat benefits: kWh/m2 per year in buildings (heating period) 6.5.1 6.5.2 6.5.3 inland. the use of the solar factor. the yield of heating period 6.6 From renewable energy produced in the building energy kWh/m2 year 6.7. Primary energy rating kWh/m2 per year,% 6.8. Carbon dioxide (CO2) emissions of CO2 per year reduction in kg , %    
 
7. building energy efficiency recommendations published by an independent expert [name] registration number [the independent expert's registration number in the register of independent experts] date * signature * note. the document properties "date" and "signature" does not fill in, if an electronic document is drawn up according to the law on electronic document design. 4. the annex to Cabinet of 9 July 2013 the Regulation No 383 building energy efficiency indicators in a comparative evaluation of heating consumption scale building corresponds almost zero energy building requirements Yes [] no [] notes. 1 building energy efficiency class in accordance with the assessment of the consumption of the building heating. 2 building assessment of consumption, kWh/m2 per year for heating. 5. the annex to Cabinet of 9 July 2013 the Regulation No. 383 of the energy performance of buildings minimum level jaunbūvēm1

Nr. p. k. Building construction intentions in the approval period of the energy performance of buildings on the minimum level of energy efficiency evaluation of new devices for heating residential buildings non-residential buildings (6.1.3, 6.1.4. noteikumu2, 6.1.5, 6.1.7, 6.1.6, 6.1.8..., the building referred to in 6.1.9 types) apartment building viendzīvokļ divdzīvokļ building or buildings that are public property and institutions, and the institutions of the State to the other non-residential buildings 1 2 3 4 5 6 1. By 2016 December 31 ≤ 70 kWh/m2 per year ≤ 80 kWh/m2 per year ≤ 100 kWh/m2 per year ≤ 100 kWh/m2 per year 2. From 1 January 2017 until 2017 31 December ≤ 60 kWh/m2 per year ≤ 70 kWh/m2 per year ≤ 90 kWh/m2 per year ≤ 90 kWh/m2 per year 3. From 2018 2018 1 January to 31 December ≤ 60 kWh/m2 per year ≤ 70 kWh/m2 per year ≤ 65 kWh/m2 per year ≤ 90 kWh/m2 year 4. From January 1, 2019-2020 December 31 50 kWh/m2 per year ≤ ≤ 60 kWh/m2 per year almost zero energy building ≤ 65 kWh/m2 per year 5. From 1 January 2021 and almost zero energy building nearly zero energy building nearly zero energy building nearly zero-energy buildings notes.  1 building energy efficiency minimum level (class) for new construction shall not apply if this requirement is not technically or functionally possible or if the cost-benefit analysis for the life of the building indicate loss. 2 Cabinet 9 July 2013 the Regulation No 383 "rules for the building of" energosertifikācij. " The Prime Minister is the Rapidity of the Newsletters instead of Minister of Economics – Minister of agriculture John Dūklav