347/2012 Sb.
DECREE
of 12 October. October 2012,
laying down the technical and economic parameters of renewable resources
for the production of electricity and the production of electricity from lifetime
supported sources
350/2013: Sb.
Energy Regulatory Office lays down pursuant to § 53 para. 2 (a). a) and b)
Act No. 165/2012 Coll., on supported energy sources and amending
Some laws (law on the supported energy sources), to perform the
§ 7 para. 3 and § 12 para. 1 (b). and) of the supported sources
energy:
§ 1
The subject of the edit
This Decree lays down the technical-economic parameters for the determination of
feed-in tariffs each type of renewable resources for the production of
electricity and the lifetime of the production of renewable electricity
energy.
§ 2
Basic concepts
For the purposes of this Ordinance, means the
and the source of the electricity energy production) equipment for the production of electricity
the specified value of the installed power, the date of entry into service and
identification number allocated by the energy regulatory office upon
the decision to grant a license for production of electricity,
(b)) is a powerhouse of electricity from renewable energy sources, energy
device for the conversion of renewable energy to electricity
that includes all the necessary facilities, including facilities for the conversion of
a renewable energy source to fuel or its editing,
(c) technological custom electricity consumption) power consumption
energy for electricity production in the production of electricity, or electricity and heat
in the main production equipment and auxiliary plant manufacture
directly related, including the production, transformation or modification of the fuel, losses in the
divorce, own consumption and losses to zvyšovacích transformers
production of electricity for supply to the distribution network or transmission
system,
d) technological custom heat demand from renewable energy sources
heat consumption in the production device and auxiliary plant, with
directly related to the production of electricity, including the production, transformation or modification of the
fuel and losses in district heat production plants of electricity,
e) useful heat from renewable sources of heat produced in the process of
the combined production of electricity and heat, which is used for the supply of the system
supply of thermal energy or for further use for technological
purposes outside their own technological consumption of heat production plants of electricity from
renewable energy sources or used for further transformation into electrical or
mechanical energy.
§ 3
Production of electricity from renewable energy sources shall consist of one
or more of the production sources of electricity.
§ 4
The precondition to ensure the 15-year period free of return on
investment in the promotion of electricity produced from renewable energy sources
farm gate prices comply with the values of technical-economic parameters for
the different types of renewable resources in accordance with the annexes to this Decree.
§ 5
Lifetime production of renewable electricity is fixed in
the annex to this Decree.
§ 6
Transitional provisions
(1) For plants referred to in service until 31 December 2006. December 2012, including
applies indicative values according to technical and economic parameters
Annex No. 3 to Decree No. 475/2005 Coll., implementing some
provisions of the Act on the promotion of the use of renewable resources, as amended by
amended.
(2) For the plant put into service from 1 January 2003. January 2013, including
the Energy Regulatory Office shall proceed, in the determination of feed-in tariffs in accordance with
technical-economic parameters laid down in this Decree.
§ 7
Regulation (EEC)
Shall be repealed:
1. Decree No. 475/2005 Coll., which implements certain provisions of
the law on the promotion of the use of renewable resources.
2. Decree No. 364/2007 Coll., amending Decree No. 475/2005 Coll.
by implementing some provisions of the Act on the promotion of the use of
renewable energy sources.
3. Decree No. 409/2009 Coll., amending Decree No. 475/2005 Coll.
by implementing some provisions of the Act on the promotion of the use of
renewable resources, as amended by Decree No. 364/2007 Coll.
4. Decree No. 300/2010 Coll., amending Decree No. 475/2005 Coll.
by implementing some provisions of the Act on the promotion of the use of
renewable resources, as amended by Decree No. 364/2007 Coll. and Decree No.
409/2009 Sb.
5. Decree 338/2011 Coll., amending Decree No. 475/2005 Coll.
by implementing some provisions of the Act on the promotion of the use of
renewable resources, as amended by Decree No. 364/2007 Coll., Decree No.
409/2009 Coll. and Decree No. 300/2010 Coll.
§ 8
The effectiveness of the
This Decree shall enter into force on 5 February 2000. November 2012, except
the provisions of § 7, which shall take effect on 1 January 2000. January 1, 2013.
Chair:
Ing. Vaghela in r.
Annex
Techno-economic parameters and the lifetime of the production of electricity from
renewable energy sources
Production of electricity from renewable energy sources
(I).
The power of water-Water power plant
1. the useful life of the plant: 30 years.
2. The request of the primary content of the energy efficiency: the efficiency of the newly
installed turbines in production is assumed to be optimum > = 85%,
the renovation of older types of > = 80% (measured at the turbine).
3. The cost of an installed unit performance and annual usage
installed power:
--------------------------------------------------------------
The specific investment costs annual usage of the installed
[€/KWe] performance [kWh/kWe]
--------------------------------------------------------------
< 150 000 > 4 000
--------------------------------------------------------------
II.
Biomass energy
1. the useful life of the plant: 20 years.
2. for the production of renewable electricity with biomass
assumes the application of useful heat from renewable sources.
3. The cost of an installed unit performance, annual usage of the installed
performance and cost of fuel:
-------------------------------------------------------------------------------
Characteristics of the cost of Annual fuel cost recovery
factory installed installed
drive performance [kWh/kWe]
performance
[Kč/kWe] -----------------------
Price Category
biomass biomass
[Eur/GJ]
-------------------------------------------------------------------------------
The source of the scorching < 75 000 > 5 000 1 170 clean biomass 2 < < 70-120 3 < 5 000 1 170
(separately) gas
from the gasification of solid
biomass
2 < 120
3 < 70
-------------------------------------------------------------------------------
Note: the classification of the various categories of biomass provides the Decree
No. 477/2012 Coll., on determination of kinds and parameters supported by
renewable energy sources for the production of electricity, heat or biomethane and
determination and storage of documents. The specific investment costs are expressed
the total investment cost per installed electrical power.
--------------------------------------------------------------------------------
Characteristics of Investment Annual fuel cost recovery
factory installed costs [EUR/GJ]
[EUR/t] performance [kWh/kWe]
--------------------------------------------------------------------------------
The source of the burning 4 400 0
municipal waste
--------------------------------------------------------------------------------
Note: for the burning municipal waste are the sources of specific investment
the costs relate to the quantity of incinerated municipal waste per year [EUR/t].
III.
Wind energy-wind power
1. the useful life of the plant: 20 years.
2. The request of the primary content of the energy efficiency: annual
average wind speed at the site of the construction of a wind power plant in height
the axis of the rotor, the proposed power plants assumes > = 6 m/s.
3. The cost of an installed unit performance and annual usage
installed power:
------------------------------------------------------------
The investment costs of the annual usage of the installed
[€/KWe] performance [kWh/kWe]
------------------------------------------------------------
2 100 < 44 000 >
------------------------------------------------------------
IV.
Geothermal energy-the use of low-potential heat
1. the useful life of the plant: 20 years.
2. The request of the primary content of the energy efficiency: Energy
potential sources of geothermal energy is assumed at least in such
level that it has been possible through the heating media permanently
earn minimum heat gain equivalent to 50 to 70 litres of water per
Second, at a temperature of 95 ° c per > megawatts of installed electric
the performance of the source.
3. The cost of an installed unit performance and annual usage
installed power:
----------------------------------------------------------------
The cost of the annual usage of the installed
installed power [kWh/kWe]
Unit
including Wells
[€/KWe]
----------------------------------------------------------------
< 275 000 > 5 700
----------------------------------------------------------------
The explanatory notes to the tables:
kWh. power unit (kilowatt hour),