108/2007 Sb.
DECREE
of 14 July 1999. April 2011
for the measurement of gas and about how the determination of damages against unauthorized
subscription delivery, unauthorized unauthorized storage, unauthorized
transportation or unauthorized distribution of gas
Change: 289/Sb.
The Ministry of industry and trade shall be determined according to section 98, para. 1 (b). and)
Act No. 458/2000 Coll., on conditions for business and public administration
in the energy sectors and on amendments to certain acts (the energy
Act), as amended by law No 158/2009, code:
§ 1
Basic provisions
(1) measurement of gas takes place at measuring point enabling the measurement of
the quantity and, where applicable, gas pressure, gas flow control, measurement
the physical and chemical parameters of the gas for the purposes of the calculation of the
delivery in kWh or MWh and transfer data to the control. Measuring site is
implemented
and between the transport system) and
1. the natural gas system of another State,
2. distribution system,
3. gas-processing,
4. underground gas storage tank,
5. the sampling point,
(b)) between the distribution system and
1. the natural gas system of another State,
2. a distribution system,
3. gas powerhouse, with the exception of distribution grids, which is
distributed another type of gas than natural gas or biometan,
4. underground gas storage tank,
5. the sampling place.
(2) gas measurement activities is the installation of measuring equipment, its
operation and servicing, inspection and maintenance of measuring equipment, the readings,
the transfer and retention of data from the measurement.
(3) data on gas quantity in m ^ 3 in all measurement locations
the exception of the measuring points between the transmission or distribution system and
the natural gas system of another State when the reference conditions: temperature
15 ° c and pressure 101.325 kPa for dry gas (gas containing no water vapour,
relative humidity of the j = 0). Calorific value in kWh/m ^ 3 and the Wobbe number
kWh/m ^ 3 at reference temperature of 15 ° c combustion.
§ 2
Types of measuring equipment
(1) the gas quantity measurement and evaluation of the data is used for measuring
a device for
and continuous measurement with the conversion) values on the conditions provided for in § 1 (1). 3,
that performs a continuous recording of the values of the amount of gas in the measuring
interval, and
1. with the daily transfer of information (hereinafter referred to as the measurement type, and ")
2. other than the daily transfer of information (hereinafter referred to as "type B"),
(b) continuous measurements without conversion) of the values that make a running record
the value of the quantity of gas in the measuring interval (hereinafter referred to as the measurement type, with "),
(c)) neprůběhové measurement without recalculation of values,
1. monthly data vyčítáním (hereinafter referred to as the "measurement of CM"),
2. other than the vyčítáním moon data (hereinafter referred to as "type C").
(2) to measure the gross calorific value is used for measuring device allowing
measurement of physical and chemical parameters of the gas.
§ 3
The assignment of the appropriate type of measurement
(1) the measurement type, and to measuring space
and between the transport system) and
1. foreign natural gas system,
2. distribution system,
3. gas-processing,
4. underground gas storage tank,
(b)) between the distribution system and
1. foreign natural gas system,
2. a distribution system (with the exception of emergency connection nodes look
distribution systems),
3. gas-processing,
4. underground gas storage tank,
(c)) at the consumption points
1. directly connected to the transmission system
2. with an annual subscription of more than 52 500 MWh.
(2) the measurement of type A or B is measured by the quantity of gas at the point of use
and) directly connected to high-pressure distribution system with an annual
the collection of over 630 MWh
(b)) directly connected to low pressure or low pressure parts distribution
system, with an annual subscription of more than 2 100 MWh to 52 500 MWh including.
(3) the measurement type, with the amount of gas can be measured at the point of use
connected to a distribution system, where it is not technically or economically
install the measurement of type A or B.
(4) the measurement of CM is the measured amount of gas in point of right
connected to the low pressure or low pressure parts of the distribution system operator with
an annual subscription from 630 MWh to 2 100 MWh including, if this sampling locations
not for technical or economic reasons, equipped with a measurement of type A,
(B) or with.
(5) the measurement of type C is measured by the amount of gas for other offtake points.
(6) Measuring places at the sampling points may be from a technical-operational
reasons, fitted with a measuring device of type A or B, even if a lower
annual gas sampling, than is the case referred to in paragraph 1 (b). c) point 2 or
in accordance with paragraph 2 (a). b). A shoulder measuring device of type A or B
shall be decided by the transmission system operator or the operator
distribution system, which is a supply point is connected.
(7) in the case of a combination of continuous and neprůběhového of measurement in
one point of consumption neprůběhových types of measurement in CM
individual gas days ^ 1) provides a linear calculation of
the monthly consumption and the number of days of the month.
§ 4
Gas measurement interval
(1) for the measurement of type and is
Basic measuring interval) 1 hour; in the first hour of the beginning of the
set at time 06:00:00 and end at time 07:00:00 gas day,
(b)) the basic interval for processing and transmission of measured data in the context
the measuring device 1 gas day.
(2) for the measurement of type B is
Basic measuring interval) 1 hour; in the first hour of the beginning of the
set at time 06:00:00 and end at time 07:00:00 gas day,
(b)) the basic interval for processing and transmission of measured data in the context
1 gas measuring apparatus a month ^ 1).
(3) the measure of S is
Basic measuring interval) 1 hour; in the first hour of the beginning of the
set at time 06:00:00 and end at time 07:00:00 gas day,
(b)) the processing of measured data in the context of the measuring device is carried out
at least once every 18 months.
(4) for the measurement of CM is the base period for the processing of measured
the data of the measuring device for 1 month.
(5) for measurement of type C is the processing of data from the measurement of gas carried out
at least once every 18 months.
(6) processing of data from the measurement of the gas is also executed when you change
gas supplier, the distribution system operator, operator
clearing, the manufacturer of the gas or the customer on termination of subscription or
the supply of gas, when the births and deaths of the obligations of the distribution above and beyond
license ^ 2), when a change made on the measuring device.
§ 5
Details of the measuring gas
(1) data from the measurement of the gas are among the participants in the gas market being passed in
M3, m-3 kWh, kWh MWh or in m3. h-1 kW and MW. The conversion of the gas supply from the
volumes of the power units is done by converting
volumes of gas to energy referred to in the annex No. 1.
to this Decree.
(2) data from the measurement of the gas are
and) data recorded by the measuring device the transmission system operator
or distribution system operator and, where applicable, read,
calculated on the basis of the data from this instrumentation,
(b)) the data read from the measuring device and passed directly to a participant in the market
gas distribution system operator, or data calculated on the
the basis of the data transmitted, if the amount of consumption in a given point
corresponds to the nature of consumption and the consumption during the preceding
periods,
1. in the case of data-by customer type deducted (C) only in the case that
the reading will be delivered within 5 days from the date of the proper reading and for data
deducted by the customer with the type of measuring CM only if the reading of the will
delivered to you the next business day until 12:00 hours from the date of the ordinary
reading,
2. in the case of reading the customer when changing gas prices or distribution taking into account
the distribution system operator this reading to the last day of the month
in which the change occurred in the case that was served within 14 days after
make a change to the gas prices or distribution,
3. the deduction of the customer when changing the gas supplier shall take the operator
This distribution system, the deduction under the conditions laid down in the legal
Regulation laying down the rules of the gas market ^ 1)
4. in the case of reading when you change the customer receives a distribution operator
the system of this reading from a new customer, directly or through
his dealer of gas as of the date of this change,
c) replacement data recorded control measuring device that is not
in the ownership of the transmission system operator or service provider.
distribution system operators, if such a device is installed, and under the
provided that corresponds to a different law ^ 3) and that the consumption of
provided for this device is demonstrable and corresponds to the nature
consumption or supply of gas and over consumption in the preceding
periods,
d) replacement data obtained by calculation in accordance with paragraph 3, estimate based on
paragraph 4 or mutual agreeing between the market participants with
gas,
e) data on the basis of the contractual relationship, if the delivery and distribution of
carried out without measuring the amount of gas measuring device.
(3) the calculation of spare data on consumption or delivery of gas and its
during the malfunction or failure when detected on the measuring device or when you
correct erroneous or missing values makes the operator
the transmission system operator or distribution system operator on the basis of
authorized service or log messages about failure or malfunction
the measuring device based on the amount of gas consumption in the previous
the comparable period when comparable nature gas sampling, in which
was the gas properly measured. If the data cannot be about the amount of power or
supply of gas used in the previous period, the calculation of spare
data on consumption or delivery of the gas, and on the basis of the inspection reading
in the following for the same period.
(4) the unavailability of the data recorded by the measuring device provides
the transmission system operator or distribution system operator
an estimate of the spare data on consumption or delivery of gas in accordance with
legal regulation laying down the rules of the gas market ^ 1).
(5) in the case of the additional finding of erroneous data on exposures measured quantity
or about the value of the gross calorific value of gas at the measuring points according to § 1 (1).
1 with the exception of consumption points can make the correction of erroneous data when
the calculation of data on the gas passed the following month after the determination of the wrong
details.
§ 6
Conditions for measuring gas
(1) for new or reconstructed offtake points provides the location of the
the measuring device the transmission system operator or
the distribution system operator. The measuring equipment is installed in
measuring point as close as possible to the point of předávacímu.
(2) on application, the Subscriber of the gas market, and where this measurement
the device can be technically possible to provide details of the measurement directly in the
measuring point.
(3) the measurement type and must be equipped with a measuring range of the main and backup,
If the hour given by the sampling or the delivery place greater
than or equal to 1 000 MWh.
§ 7
The measuring equipment
(1) installation, removal or replacement of measuring device or its part in
measuring point, which does not own the transmission system operator or
the distribution system operator must be reconciled in advance
the transmission system operator or the operator
the distribution system.
(2) removal or replacement of measuring device, especially when
their collection or supply of gas, or gas supply interruption
due to the unlawful collection or delivery, unauthorised transportation,
unauthorized distribution, findings or defect on the measuring
the device, a regular verification of the measuring device or validating
the accuracy of measurement at the request of a market participant with gas.
(3) the exchange of the measuring device is carried out also in cases where the range of
the existing measuring equipment does not conform to the actual, or type of subscriptions
the measuring device does not match the assignment of the appropriate type of measurement. The exchange of
shall be carried out in the projednaném of the term with the customer on the spot by a modified
for the installation of a new measuring device.
(4) the removal or exchange of the measuring device or its parts must be
the affected Party is informed of the gas market. On the exchange of the measuring device
or part thereof for the purpose of official verification must be the affected party
the gas market is informed at least five days in advance.
(5) in the demontovaného test equipment to verify the accuracy of measurement shall
be the distribution system operator shall promptly record
balances and made identification of the measuring device (manufacturing
number, type of measuring equipment, year of verification).
(6) failure or malfunction of the measuring apparatus shall be demonstrated by
authorized metrological centre or in the case of obvious defects
or fault message transmission system operator, prepared or
distribution system operator.
§ 8
The transmission and storage of measurement results
(1) measured data supply and gas measurement and measurement type and type
(B) in the measuring device are kept for at least 40 days from the date of the dropper.
(2) data from the measurements necessary to account for supplies and gas and
the actual value of the supplies and gas to be passed for the market operator
evaluation of deviations shall keep the transmission system operator or
the distribution system operator, which provides measurement, at least 36
months from the date of the dropper. The scope and terms of the transfer of data from the measurement
necessary to account for supplies and gas and actual values
the supply and consumption of gas to be passed to the market operator for the evaluation
derogations shall lay down the law, laying down the rules of the market in
gas ^ 1).
§ 9
The method of determining the amount of damages against unauthorized collection, delivery,
transport, storage, or distribution of gas
(1) an unauthorized gas sampling will determine the amount wrongly taken
gas transmission system operator, or the operator of a distribution
system on the basis of the measured or otherwise discovered, demonstrable
data on unauthorized gas sampling.
(2) in cases where it cannot determine the actual amount unduly
the gas collected in accordance with paragraph 1, provides for the transmission
system operator or distribution system operator the amount unduly
collected gas to determine the amount of compensation calculated according to the
paragraphs 3 to 8.
(3) the amount unduly collected gas is in the case of knowledge
label inputs and the number of individual gas appliances
installed in place of unauthorized subscription, calculated by the formula
referred to in annex 2 to this Decree.
(4) in the event that the amount unduly collected gas cannot be determined
According to the formula set out in annex 2 to this Decree and instead
unauthorized subscription is fitted with a measuring device, calculate the amount of
unduly collected gas under the calculation referred to in annex 3 to the
This Decree.
(5) in the event that the amount unduly collected gas cannot be determined
pursuant to paragraph 3 or 4, and the place of the collection is equipped with
gas pressure regulator, the amount wrongly taken
gas as in paragraph 4, instead of the nominal hourly flow
the measuring device is assumed to be the nominal hourly flow rate of the pressure regulator
gas.
(6) in the event that you cannot follow the previous paragraphs, shall lay down the
the amount unduly collected gas based on the inner diameter
pipeline gas pipeline at the beginning of the sampling gas equipment for the main
gas seal and pressure values in this pipeline. The amount unduly
gas shall be taken as in paragraph 4. Place
nominal hourly flow rate measuring device for calculation of the
maximum technically achievable annual gas substitutes
technically achievable hourly supply of gas to the pipeline,
calculated in accordance with the formula set out in annex 4 to this notice. In
If it is not possible to determine the internal pipe diameter pipeline
beginning of the sampling gas equipment, the internal diameter
pipeline connections.
(7) if the operator of a transmission system operator or distribution
the system does not detect the duration of unauthorized sampling of gas, it is considered that,
He insisted that the unauthorized gas
and the measurement of type C) and with all the time since the last reading in the case that
When reading it was possible unauthorized subscription figure, but no longer than for a period of
24 months,
(b) in all other cases) after the last physical examination of the place of
detect unauthorised sampling carried out by the operator, the distribution
system, but no longer than for a period of 24 months.
(8) in the case of an intervention in a measuring device or gas, even if
in part, drawn from that part of the device, which is unmeasured gas,
from the amount unduly collected gas calculated in accordance with paragraphs
3 to 6, subtracts the quantity of gas measured by the transmission system operator
or distribution system operator on the measuring device. In
other cases of unauthorized sampling of gas, with the exception of unauthorized
gas sampling, where the entire volume of unauthorized sampling of gas measured
the measuring device measured the quantity of gas, transmission
system operator or distribution system operator does not take.
(9) the amount unduly collected gas identified pursuant to paragraph 1
or calculated in accordance with paragraphs 3 to 6 is converted to energy
units (kWh or MWh) with a gross calorific value of applied
transmission system operator or distribution operator
system for comparable case contractually authorized the subscription.
(10) the amount of compensation an unauthorized gas sampling shall be
the valuation amount unduly collected gas from
paragraph 1 or calculated in accordance with paragraphs 3 to 6 and converted to
power units referred to in paragraph 9 of the components of the price according to price
the decision of the Energy Regulatory Office effective at the time of the findings
unauthorized collection of gas, while the price of unduly collected gas
It consists of
and twice the monthly arithmetic mean) fixed daily gas prices
for lack of buffer gas in the month preceding the findings
unauthorized subscription
(b)) prices for gas distribution by category of customers and annual subscription
gas,
(c) gas prices) to the home zone ^ 1), if it is separately
fixed, or load the customer directly connected to the transmission
the system,
(d)) of the price for clearing the market operator's activities,
e) value added tax and the tax on gas.
(11) the amount of compensation for an unauthorized gas may also be
a written agreement between the transmission system operator or
distribution system operator and a customer, or a person
should illegal gas sampling on a benefit or advantage
participated. The compensation provided for in this way must not be higher than
the refund calculated in accordance with the preceding paragraphs.
(12) for the determination of the amount of damages in wrongful supply of gas,
When the unauthorized transport of gas, or when unauthorized distribution of gas
It shall apply the provisions of paragraphs 1 to 10 mutatis mutandis.
(13) the part of the compensation is remuneration demonstrable strictly necessary
costs incurred to detect unauthorized gas sampling,
unauthorized supply of gas, the unauthorized transport of gas or unauthorized
distribution of gas, they interrupt and checking of the measuring device and
expert evidence, if any, that are not included in the regulated prices for
gas transport or distribution of gas.
§ 10
Measurement of physical and chemical parameters of gas
(1) the transmission system operator is responsible for the measurement of the prescribed
the values of the physical and chemical parameters of the gas at the entry points into the
the transmission system operator and the transmission system of the output points. The measured
the value of the output points of the transmission system to the distribution
the system passes the transmission system operator in the form of monthly
log with a daily breakdown on each transfer points
distribution system operators.
(2) in the case of gas production is responsible for measuring the prescribed values
the physical and chemical parameters of the gas on the output point of the plant
gas manufacturer.
(3) in the case of the border station between the distribution system and
foreign shipping system or distribution system is responsible for
measurement of prescribed values of physical and chemical parameters of the gas to
entry into the distribution system operator of the distribution system.
(4) the distribution system operator shall be responsible for the proper determination of
the values of the gross calorific value of gas in various parts of the distribution
system based on the values transmitted to the transmission
system and gas producers.
(5) the physical and chemical parameters of the gas is measured mainly in nodal
points of quality and in the places provided for transmission
system operator and distribution system operator. The nodal point of the quality
is
and border station forming) pass-through space between the foreign
the natural gas system and the transmission system or distribution
System; the Hub Transport server in the perimeter station is always measured the physical and
chemical gas parameters in the range of at least
1. gas composition (for calculation of gross calorific value, density and Wobbe number),
2. the water dew point and hydrocarbon dew point higher,
3. the content of sulphur and the various sulfur compounds,
4. oxygen content,
5. where appropriate, the additional folders, whose exact specification provides
the operator of a transmission or distribution system,
(b)) # gas pass-through is a powerhouse and the transport system or
the distribution system; in this delivery place is always measured by the physical
gas and chemical parameters in the range at least as in (a)),
c) pass-through space between the underground reservoir and transport
system or gas distribution system, or foreign
System; in this delivery place is always measured physical and chemical
gas parameters in the range of at least
1. gas composition (for calculation of gross calorific value, density and Wobbe number),
2. the water dew point and hydrocarbon dew point higher,
(d) the submission site) between the transmission system and distribution system,
If it is determined the nodal point of quality; in this delivery place
always measure the physical and chemical parameters of the gas in the range of at least
gas composition (for calculation of gross calorific value, density and Wobbe number).
(6) the prescribed values for physical and chemical parameters of the gas are
listed in annex 5 to this Decree.
§ 11
Transitional provision
Liquidated damages for unauthorized sampling, distribution, transport or delivery of
gas, occurred before the entry into force of this order, the
be assessed according to the existing legislation.
§ 12
Regulation (EEC)
Decree No. 254/2001 Coll., laying down the rules of operation of transport
system and distribution systems in the gas industry, is hereby repealed.
section 13 of the
The effectiveness of the
This Decree shall enter into force on 1 January 2000. May 2011.
Minister:
Ing. Sri k v r.
Annex 1
The conversion of the volumes of gas to energy
(1) the basis for the accounting of gas supply to the gas market participants is
the amount of energy supplied in the gas.
(2) the amount of energy Supplied gas is determined by the relation
Q = Vp. to the. It
Where is:
Q-quantity of energy in kWh supplied
VP-operational volume of gas in m3 measured meter operating pressure and temperature
for the billing period to the nearest whole unit
k-volume rating factor is the ratio between the volume of a gas at reference
conditions and the volume of production, rounded to four decimal places.
It-the average value of the gross calorific value kWh/m3 in volume for posting
period, rounded to four decimal places.
(3) the volumetric rating factor for dry gas is calculated from the relation
Tv pp + pb zoom
k = ------ x ----------- x ------
TP zp pv
where is:
Tv-reference temperature expressed in a scale of Kelvinově to 288.15 (tv = 15 ° c),
where tv is the reference temperature in ° c
TP-temperature gas at the meter, expressed in the Kelvinově scale, rounded
to two decimal places
pp-working pressure of gas expressed in kPa measured in meter or
set value output overpressure gas pressure regulator
located in front of the meter or by or for the average value rounded
to one decimal place
PB-the average annual value of the atmospheric pressure of the air in the place of sampling gas
in kPa; rounded to one decimal place; for the determination of this value
It is the responsibility of the transmission system operator or distribution system operator,
from which the gas is supplied to the
PV-the reference pressure 101.325 kPa, in the amount of
ZV-kompresibilní factor in the reference conditions
ZP-kompresibilní factor in operating conditions
(4) If, at the point of use to time changes the values of the gross calorific value
by volume, its average value as the mean value of the
supplied in terms of volume for the billing period. Medium
the value supplied in terms of volume is determined by the weighted
average. If the billing period is longer than 1 month, the
the mean gross calorific value of volume for the billing period, the weighted
the average of the previous 12 months.
(5) if the area of the gas supplied to the gas from one point to
fluctuating energy value, the time averages of the spalných
ther vol. delivered volumes of gas and products of the heat volumes and spalných
by volume (the amount of energy supplied to gas). The weighted average gross
heat a solid for the whole billing period is the sum of the products of time
volumes and spalných heat divided by the total volume delivered volume
gas per billing period.
(6) in the event that in the field of gas is supplied to the gas from different
sources that differ spalnými teply volumes, is the weighted average of the
in terms of volume for the period determined by the proportion of the sum of the
the amount of energy supplied for the posting period from these sources, and the sum of the
the total volumes of gas supplied from these sources.
Annex 2
Calculation of amount unduly collected gas
QNOP = sum (ti. Sum (dij pj.))
(I) (j)
where:
QNOP the amount of unduly collected gas in kWh, m3, respectively.
and the index for the calendar month,
(j) index for the appliance,
power consumption of the appliance in the PJ label kW or m3/h,
you the duration of unauthorised gas sampling in the calendar měsíciv (d),
dij consumption period j-th appliances for the i-th month in h d-1.
The period of use of selected types of appliances
(1) the selected customer appliances category household types:
-gas cookers, gas cookers, gas hob, combined
cookers-2 hours a day,
-water heaters-2 hours a day,
-storage water heaters-5 hours a day
-combined boiler with domestic HOT WATER-the number of hours according to the following table:
---------------------------------------------------------------------------------------------------
Month 1. 2.3. 4.5. 6.7. 8.9. 10.11. 12.
---------------------------------------------------------------------------------------------------
hours per day 11.00 9.21 7.94 4.76 2.18 1.54 1.46 1.49 2.08 4.82 8.13 10.08
---------------------------------------------------------------------------------------------------
(2) Appliances: otopového
---------------------------------------------------------------------------------------------------
Month 1. 2.3. 4.5. 6.7. 8.9. 10.11. 12.
---------------------------------------------------------------------------------------------------
hours per day 10.00 8.21 6.94 3.76 1.18 0.54 0.46 0.49 1.08 3.82 7.13 9.08
---------------------------------------------------------------------------------------------------
(3) the appliance technological nature:
-u jednosměnného 8 hours a day,
-traffic will be maintained for 16 hours a day,
-for continuous operation 24 hours a day,
-any other mode-operating time according to proven documents by the customer.
Annex 3
Calculation of amount unduly collected the gas, if you are not aware of
current label and number of gas appliances
(1) in the case of subscriptions with the predominant character of the consumption quantity otopovým
unduly collected gas will be calculated by the following formula:
Ki
QRO. --------
100
QNOP = SUM-------------------. TI
even those
where:
QNOP the amount of unduly collected gas in m3,
and the index for the calendar month,
Ki a percentage of maximum technically available annual
gas accounted for the calendar month in%,
---------------------------------------------------------------------------------------------------
Month 1. 2.3. 4.5. 6.7. 8.9. 10.11. 12.
---------------------------------------------------------------------------------------------------
% 18.98 15.58 13.18 7.13 2.24 1.02 0.87 0.93 2.05 7.25 13.54 17.23
---------------------------------------------------------------------------------------------------
You the number of days in the relevant calendar month in days
you the duration of NOP in the relevant calendar month
in days,
QRO technically achievable annual unauthorized subscription
gas in m3 is given as:
Qro = Qn. 8760 x 0.3
where:
Nominal flow rate qn, the hour of the measuring device in m3/h,
8760 hours (non leap) the calendar year
0.3 utilization.
(2) in the case of subscriptions with the dominant technological character of consumption,
the amount unduly collected gas calculated by the formula:
QRT
QNOP =--------. tcelk
365
where:
QNOP the amount of unduly collected gas in m3,
tcelk the number of days the duration of unauthorized sampling on days
365 the number of days in the calendar year (a non leap).
QRT technically achievable annual unauthorized subscription
gas in m3, is given as:
Qrt = Qn. 8760. 0.5
,
Nominal flow rate qn, the hour of the measuring device in m3/h,
8760 hours (non leap) the calendar year
utilization coefficient of 0.5.
(3) if it cannot be determined whether the subscription with the predominant otopovým
the character of consumption or subscription with the predominant technology
the character of consumption, the calculation under paragraph (2).
Annex 4
The formula for calculating the maximum technically achievable hourly deliveries
gas pipeline
PI p + 96.5
Qn = ------ . D2. w. ----------- . 3600
4101.325,
where:
Qn technically achievable hourly supply of gas
the pipeline when the reference conditions in m3/h,
(D) the internal diameter of the pipeline gas pipeline in m,
w maximum speed of gas in the pipeline in m.s-1
-for gas pipelines to 200 kPa, including w = 2 m s-1,
-for medium-pressure pipelines above 200 kPa to 400 kPa, including the w = 1 m s-1,
p excess pressure in the gas pipeline in kPa,
96.5 Central barometric pressure in kPa,
the reference pressure 101.325 in kPa,
3600 conversion from seconds to hours
Annex 5
The prescribed values of physical and chemical parameters that determine
the quality of the gas
(1) the characteristic values for the combustion of
---------------------------------------------------------------
Quantity Unit Range
---------------------------------------------------------------
Wobbe number kWh. m-3 up to 12.7 14.5 ^ 1)
MJ m-3 to 45.7 52.2 ^ 1)
Calorific value kWh. m-3 up to 11.8 9.4 ^ 1)
MJ m-3 to 33.8 42.5 ^ 1)
Calorific value kWh. m-3 to 8.4 10.6 ^ 1)
MJ. 30.4 m-3 up to 38.4 ^ 1)
Relative density-up to 0.7 0.56 ^ 1)
---------------------------------------------------------------
1) values in the reference conditions (§ 1 para. 3).
---------------------------------------------------------------
(2) the composition of the gaseous fuels-natural gas
-------------------------------------------------------------------------------------------------------------
Parameter Unit Value
---------------------------------------------------
Freight Distribution
system system
-------------------------------------------------------------------------------------------------------------
Methane content% m min 85.0
-------------------------------------------------------------------------------------------------------------
Water content expressed as ° c max. -7 ° c at max. -7 ° c
the dew point temperature of water operating pressure of 4 MPa operating pressure of 4 MPa
-------------------------------------------------------------------------------------------------------------
The hydrocarbon content, expressed in ° c max. 0 ° c at a maximum of 2 ° c below
as the dew point temperature the temperature of the soil when the operating pressure
operating pressure of hydrocarbons
-------------------------------------------------------------------------------------------------------------
The content of ethane% m max. 7.0
-------------------------------------------------------------------------------------------------------------
Propane content% m max. 3.0 max. 4.0
-------------------------------------------------------------------------------------------------------------
The contents of the sums of butanes% Mole max. max 2.0. 4.0
-------------------------------------------------------------------------------------------------------------
The contents of the sums pentanů and higher% Mole max. 0.5 max. 3.5
hydrocarbons
-------------------------------------------------------------------------------------------------------------
Oxygen content% Mole max. 0.02 max. 0.5
-------------------------------------------------------------------------------------------------------------
The carbon dioxide content% Mole max. 3.0 max. 5.0
-------------------------------------------------------------------------------------------------------------
The nitrogen content% Mole max. 5.0 max. 10.0
-------------------------------------------------------------------------------------------------------------
The content of inerts (nitrogen and carbon% mol max max 10.0 8.0
dioxide)
-------------------------------------------------------------------------------------------------------------
Total sulphur content (without mg m-3 Max. 30 ^ 1)
odorant), annual average
the value of the
-------------------------------------------------------------------------------------------------------------
The content of sulphur merkaptanové mg m-3 max. 5 ^ 1)
(no odorant)
-------------------------------------------------------------------------------------------------------------
The hydrogen sulphide content (without odorant), mg m-3 max. 6 ^ 1)
the annual average
-------------------------------------------------------------------------------------------------------------
Fog, dust, condensates-absent ^ 2)
-------------------------------------------------------------------------------------------------------------
1) values in the reference conditions (§ 1 para. 3).
2) under the term absent means the removal of the fog, dust and condensate to the extent that the
ensure safe and reliable operation of gas devices and gas sampling device.
1) Decree No. 365/2009 Coll., on rules of the gas market, as amended by
amended.
2) Act No. 458/2000 Coll., on conditions for business and for the exercise of State
management in the energy sectors and on amendments to certain laws
(Energy Act), as amended.
3) Act No. 506/1990 Coll., on weights and measures, as amended.