Hygiene Requirements For The Swimming Pool And Saunas

Original Language Title: hygienické požadavky na koupaliště a sauny

Subscribe to a Global-Regulation Premium Membership Today!

Key Benefits:

Subscribe Now for only USD$40 per month.
238/2011 Sb.



The DECREE



of 10 June 1999. August 2011



on the determination of the sanitary requirements for the swimming pool, the sauna and the health

the levels of sand in the outdoor playing surfaces of the hookworm is



Change: 97/2014 Sb.



The Ministry of health provides under section 108, paragraph. 1 for the implementation of section 6a

paragraph. 6, section 6 c of paragraph 1. 2, section 6e, 6f, paragraph. 3, section 13 (3). 2, § 18 paragraph. 3 and

section 82a, paragraph. 5 of the law No. 258/2000 Coll., on the protection of public health and the

changes to some related laws, as amended by Act No. 151/2011 Sb.

(hereinafter referred to as "the Act"):



PART THE FIRST



GENERAL PROVISIONS



§ 1



This Decree incorporates the relevant provisions of the European Union ^ 1) and

modifies the



and) Rules monitoring and assessment of water quality in natural

swimming pools, evaluation, classification, terms, method and scope

informing the public about the quality of the water in the pond,



(b)) and physical health limits microbiological quality indicators

the water in the pond, indicators and limit values of reproduction

cyanobacteria cyanobacteria outbreak monitoring rules and the rules of Visual inspection

water pollution,



(c)) methods, rules, frequency, timing and scope of laboratory control

bathing water in natural and artificial swimming pool, water for showering

or cooling, dates of transmission protocol on the results of laboratory

checks the quality of water and a way to demonstrate the equivalence of the laboratory

the methods and rules,



(d) a breakdown,) the requirements for equipment and operation of natural or artificial

swimming pools or saunas,



(e)) and the highest limits limit values of microbiological, physical and

chemical indicators of the quality of bathing water in the artificial swimming pool and

cooling down in the sauna, climatic conditions, hygiene requirements for

breakdown, equipment and operation of artificial rock pools and saunas, and requirements for

the quality and yield of water source for artificial swimming pool and sauna,



f) hygiene requirements for yield, quality, and editing laboratory

analysis of the source of water for artificial swimming pool and sauna, disinfection, treatment,

replacement and the temperature of the water for bathing, hygiene requirements for recirculating

system, its equipment and the intensity of the recirculation, properties, equipment and

materials equipment, artificial swimming pool and saunas, their maintenance and

storing clothes, infants and toddlers in swimming, climatic

conditions of artificial swimming pool and saunas and their measurement,



(g)) the way and extent of quality control of bathing water or cooling,

the elements of the operating journal and the method and extent of the evidence of the results of

controls and measurements in the production journal



h) hygiene microbiological indicators of water quality in other

surface waters for swimming and bathing water areas arising

mining activities, indicators and limit values of cyanobacteria,

the rules of the monitoring of the occurrence of cyanobacteria, a Visual inspection of the pollution rules

the macroscopic algae and water management and the method of evaluation of water pollution

in other surface waters for swimming and bathing water areas

incurred by the mining activities, the rules for the processing of the monitoring

calendar and rules for monitoring the quality of surface waters for swimming,

rules for the assessment of these waters, the criteria for the classification and

the method, timing and extent of the information to the public,



I) hygiene microbiological, Parasitology and chemical

pollution of the sand in the hookworm is on outdoor playing areas.



§ 2



Interpretation of the terms



(1) For the purposes of this Ordinance means



and filling water water) which is fed into the pool from the water source,

for example, the water for public use, or from a natural healing

the resources proven in accordance with other legislation ^ 2); for filling water

can be considered and adjusted the water from the water source, which is of

technological or industrial reasons, supplemented by minerals,



(b) the water filling water diluent), which is used for replacement and replenishment

the water in the swimming pool or the swimming pools,



(c)) recirkulovanou water water after leaving the pool passes

recirculating treatment and after mixing with water-dilutive returns

back to the pool; dilutive water must be brought into the system so that the

immediately went through recirculating treatment plant,



(d) water is water) before entering the pool, which was modified.

including disinfection and heating,



recirculating water treatment plant) system of technological steps that

includes at least the mechanical filtration for catching coarse impurities,

If it does not contain a different degree of editing, coagulation, or other

the technological level of editing, removing, in particular, colloidal substances,

sand filtration or on another suitable medium filtration, disinfection and

water transport system between the swimming pool, technology elements, and the swimming pool,



(f)), a swimming pool, a pool with water temperature 28 ° c for bathing and lower,



g) koupelovým pool swimming pool with a water temperature of 28 ° c for bathing,



h) pool for infants and toddlers pool designated for bathing and swimming

children under the age of 3 years,



even with the largest tank) a wading depth of bathing water 40 cm,



j) swimming pool operated by the person providing the care in the health pool

device or the Institute of social welfare, which is filling with water, the water from the

water source or from a natural source, used to

the provision of health care, and the healing, rehabilitation or

regenerative purposes,



k) swimming pool with natural healing source pool, which is filling with water

water from natural sources and not to provide

health care,



l) piscinou type of baths, therapeutic swimming pool is located directly above the

natural healing source; the water comes from a natural healing source

directly to the swimming pool.



(2) artificial swimming pools For swimming pools, for the purposes of this Ordinance shall not be regarded

swimming pools, designed for use by one person only, that is, before any

use clean, sanitised and drainage, filling with water.



PART THE SECOND



NATURAL SWIMMING POOL OPERATING ON SURFACE WATERS, OTHER SURFACE

BATHING WATER AND BATHING WATER AREA RESULTING FROM MINING ACTIVITIES



§ 3



Structure, equipment and operation



(1) the area of the swimming pool must guarantee the conditions for your location

drainage and sewerage services. Breakout areas must be maintained in a

clean and tidy; priority shall be a grass surface, which

must be regularly maintained.



(2) the swimming pool must be equipped with a readily available toilets ^ 3), where

Unable to provide running water, it is possible to install a chemical toilet.



(3) For waste disposal must be around the object pool

suitable locations spaced waste receptacles.



(4) where the swimming pool is equipped with dressing rooms or changing cabins,

floors and walls of the dressing rooms or cabins must be smooth, easily

clean material. The floor must have a non-slip surface ^ 3).

Changing cabins can be solved and the curtain on an outdoor surface.



(5) where the swimming pool is equipped with showers, these can be set up as

loose or in stalls. The floor of the shower must be easy to clean, with

an anti-slip surface ^ 3). Waste water from showers must be taken to

winding up under other legislation ^ 4) ^ 5) outside the spaces intended for

swimming.



(6) at the time of the bathing season must be each day before or after

the end of the operation carried out the cleaning of all space, including areas designated for

relaxation and sunbathing. At least once a day the floors of dressing rooms,

dressing cabins, washrooms and toilets including seats washed in a suitable

disinfectant solution at least once daily and empties waste receptacles.



Rules for monitoring water quality



§ 4



The General rules for monitoring water quality



(1) when the sampling of the water and the determination of indicators of the quality of water

proceed according to Czech standards ČSN EN ISO 5667-1 (75

7051) water quality-sampling, part 1: instructions and program design collection

sampling and sampling methods, ISO 5667-4.6 (75 7051) Quality

water-sampling, part 4: guidelines for the sampling of water reservoirs and

Part 6: guidance on sampling of rivers and streams, ČSN EN ISO 19458 (75

7801) water quality-sampling for microbiological analysis and CSN 75

7717 water quality-determination of planktonic cyanobacteria, if in this Decree

unless otherwise specified.



(2) the Protocol on results of laboratory checks must be passed to 3

working days from the date of the sample to the competent authority of the protection

public health.



§ 5



The rules for the monitoring of the microbiological parameters



(1) the microbiological indicators of water quality are laid down in annex No. 1.

to this Ordinance in column A.



(2) water sampling for the determination of microbiological indicators and

When the transport of samples to the laboratory in accordance with Annex 2 to the

This Decree. The determination shall be made in the laboratory methods laid down in the

Annex No 1 to this notice the column (E).



(3) proof of the equivalence of non-reference methods laboratory

control of water microbiological parameters is carried out using the method described in

section 7.2. ČSN EN ISO 17994 (75 7016)-water quality-criteria for

the findings of the equivalence of two microbiological methods.



§ 6



Rules for monitoring the occurrence of cyanobacteria



(1) the Bathing Water must be monitored in the range indicated in the table.

1 of annex 4 to this Decree and in frequency according to § 8. If there is a
exceeded the limit value for the indicator water flower or for pointer

transparency for both indicators, as appropriate, at the same time, it is necessary to perform

the monitoring referred to in paragraph 2.



(2) the bathing water, which can be reasonably during the bathing season

assume the cyanobacteria under section 10, paragraph 1. 1 or during bathing

the season was considered a suspected occurrence under paragraph 1, they shall

be further monitored in the range given in table 2 of annex 4 to this

the Decree.



section 7 of the



Rules for the implementation of Visual inspection



The Visual inspection of the bathing water is to be carried out in the scope of the

Annex No. 5 to this Decree and in frequency according to § 8.



§ 8



The monitoring calendar



(1) the determination of the individual subscriptions and data indicators, which

individual subscriptions are established shall be governed by the following rules:



and) the first sample must be taken shortly before the start of the bathing season



(b)) other subscriptions are distributed evenly over the entire bathing

the season for sampling for the determination of microbiological indicators according to

§ 5 (3). 1 must be the time between the scheduled subscriptions longer

than 28 days,



(c)), Visual inspection under section 7 and control under section 6 (1). 1 is

carried out at least on each sampling for the determination of microbiological

indicators,



(d)) for bathing waters, for which monitoring is carried out in accordance with section 6 (1). 2,

the indicators are determined in accordance with Annex No 4 to this Decree of table 2.

The subscriptions for these indicators are distributed evenly throughout the

the bathing season. Time between individual subscriptions cannot be longer than 14

days.



(2) the monitoring shall take place no later than 4 days after the date specified in the

the monitoring calendar.



(3) in the event of short-term pollution it is necessary to remove one additional

the sample to be confirmed, that the pollution. This sample is not

part of a set of data on bathing water quality. If you need to replace the

a sample, from which a disregarded sample under section 9 (2). 3 (b). and)

an additional sample of the 7 days of the short-term pollution.



The rules of the assessment and the classification of water quality



§ 9



Assessment and classification of microbiological analyses



(1) after the end of each bathing season public health protection authority

for each monitoring location data set, which includes

the results of the determination of the indicators referred to in section 5 for the just expired and 3 previous

the bathing season. The data file must contain at least 4 results for

each parameter of each rated the bathing season. However, if some of the

investigational bathing seasons less than 8 weeks, the data file contains

a minimum of 3 results.



(2) Data File shall be drawn up and from the smaller number of bathing seasons, than

referred to in paragraph 1, in cases



and) If this is a newly designed monitoring instead monitored less than 4

the bathing season, or



(b)) If during the previous 4 bathing seasons change

likely to affect the classification of the waters referred to in paragraph 5. In this case,

the data file is drawn up from the results of the measured after this change. Always

However, the data file must contain at least 16 samples, with the exception of

swimming pools, for which there is a bathing season of less than 8 weeks. In this case,

the file must contain at least 8 samples.



(3) In the data file will include only the results obtained in accordance with

the monitoring calendar, with the exception of the results, from which it was

apart because of short-term pollution; the results do not include

the samples were taken to determine that the short-term

pollution. In the data file to include the results of the indicators

enterococci and coliform termotolerantní obtained in accordance with the Decree of the

No 135/2004 Coll. termotolerantní Pointer for coliform bacteria

this purpose it considers equivalent indicator Escherichia coli.



(4) the assessment of the quality of water is carried out after the end of each bathing season

in accordance with the procedure referred to in annex 3 to this decree with the use of

the file of the data referred to in paragraph 1 or 2. On the basis of the assessment is

the quality of the bathing water in accordance with annex 3 to this notice

classified by the degree of



1. excellent



2. the good



3. acceptable



4. inadequate.



(5) If the data file does not contain a sufficient number of samples referred to in

paragraphs 1 and 2, it is not possible to carry out the assessment and classification according to the

of paragraph 4. Until you can do the first classification, assessing the

microbiological pollution of the body of public health protection on the basis of the

assessment of the health risks.



(6) on the basis of the previous seasons, and based on the knowledge of local

the conditions and in accordance with the Decree of the Assembly of profiles ^ 7) will examine the protection authority

public health, whether the water is not susceptible to short-term pollution.



§ 10



Assessing the occurrence of cyanobacteria



(1) before the start of the bathing season will examine public protection authority

health, whether they can expect during the bathing season, with great

probability of exceeding the limits of the cyanobacteria degree according to the

Annex No 4 to this Decree of table 2. This assessment is carried out on

the basis of data on the occurrence of cyanobacteria in the preceding bathing seasons.

If it is on the site, from which there are no data on the

the occurrence of cyanobacteria from the previous seasons, it is assumed that the cyanobacteria

It is likely, if according to the nature of the site cannot conclude the opposite.

For the water, which can be expected with high probability array

cyanobacteria, especially water, where he was at least once for the last 3

years exceeding the limits observed occurrence of cyanobacteria (II). degree by

paragraph 2 or in the previous season, recorded the occurrence of cyanobacteria

exceeding the limits of the degree.



(2) the evaluation of the occurrence of cyanobacteria is carried out according to annex No 4 to this

the Decree. When exceeding the limits of the first degree shall be a shortening of frequency

subscriptions for the purpose of checks on 5 to 9 days.



(3) the limit values of the grade I, II. degree and cyanobacteria

not forming příhladinové water flowers and (III). the degree is achieved when

the limit values for the indicator, the indicator for cyanobacteria

chlorophyll-and listed in table 2 of annex 4 to this notice.



(4) if the previous guest in the swimming season in progress

for limit values have been exceeded (III). grade, it is necessary to carry out the

evaluation in accordance with Annex No 4 to this Decree table 3.



§ 11



Cumulative assessment



According to the rules referred to in annex 6 to this Ordinance shall be carried out

comprehensive evaluation of water quality.



§ 12



The scope, terms and method of informing the public



(1) At an easily accessible location in the vicinity of the bathing places must be

provides the following information:



and) the current bathing water classification under section 9 (2). 4 and the ban

swimming or advice against bathing, and including the use of a unique

the marking referred to in annex 3 to this Decree,



(b)) a general description of the bathing water,



(c)) in the case of bathing waters susceptible to short-term pollution



1. notice that the bathing water is subject to short-term

pollution,



2. the indication of the number of days in which he was in the preceding bathing season

because of such short-term pollution released bathing prohibition or

warning before bathing,



3. warning if such short-term pollution, or

If you have it,



(d) information on the nature of and) the expected duration of the exceptional situations,



(e)) is issued if a bathing prohibition or advice against bathing, announcements for

the public stating the reasons for



(f)) is a permanent bathing prohibition or permanent advice against bathing,

the fact that the water in the area concerned is no longer a bathing water

stating the reasons for the cancellation of the classification,



(g)), where it is possible to obtain more detailed information referred to in paragraph 2.



(2) in a way that allows remote access to the data must be available

referred to in paragraph 1 and



and) the list of bathing waters,



(b) the results of the evaluation of the quality summary) of the waters carried out under section 11,



(c)) the classification of each bathing water in accordance with § 9 (2). 4 in the

the last 3 years and their profile ^ 7), including the results of monitoring,

that has been done since the last classification,



(d)), in the case of bathing waters classified as "poor"

information about the causes of the pollution and measures taken to ensure that

avoid exposure of bathers pollution and tackle the causes of

pollution,



e) in the case of water, which are subject to short-term pollution,

General information about the



1. the conditions that can lead to short-term pollution,



2. probability and probable duration of such pollution,



3. the causes of the pollution and measures taken to prevent the

bathers ' exposure to pollution and to tackle its causes.



(3) the information referred to in paragraphs 1 and 2 shall be in accordance with the needs of the few

languages.



PART THE THIRD



TANKS FOR BATHING AND ALLOWED FOR THE PURPOSE OF SWIMMING RUNNING

THE NATURAL WAY OF PURIFYING WATER FOR BATHING



section 13



Structure, equipment and operation



The requirements for the equipment, cleaning and operation of reservoirs for bathing and buildings

allowed for the purpose of running the natural bathing method

clean bathing water are listed in section 3.



§ 14



Rules for monitoring
(1) the quality of bathing water must be controlled in the range and frequency of

listed in table 2 of annex 7 to this Decree.



(2) water sampling for the determination of microbiological indicators and

When the transport of samples to the laboratory in accordance with Annex 2 to the

This Decree. Subscriptions are made always in operation, as soon as possible

However, the 3 hours after the start of operation, if it is on the checks carried out

the operator, or at any time during operation, if it is a subscription within the

the State health supervision. If the operation of the swimming pool less than 3

hours, the time between the start of the operation and the collection of shorten. proportionately



(3) the Protocol in electronic form must be submitted within 3 working days

from the date of the sample to the competent authority to protect public health.



§ 15



Evaluation of water quality



(1) the water quality in the source shall not exceed the limit values laid down in

table 1 of annex 7 to this Decree.



(2) If during the bathing season exceeded the limit value for the

microbiological indicators, it is necessary to implement without delay the restart

the subscription.



(3) If during the previous bathing season measured results

microbiological parameters always lower than the limit values referred to in

table 2 of annex 7 to this Decree, may be in the following

the bathing season is reduced to half the sampling frequency. When crossing

the exposure limit values are once again launches sampling once every 14 days.



PART THE FOURTH



ARTIFICIAL SWIMMING POOL AND SAUNAS



section 16 of the



Source of water for swimming pool, artificial swimming pool



(1) when choosing a water source is preferred water supply from the

public water supply or other authenticated sources of drinking water or of

the natural medicinal resources with sufficient strength to enable

the necessary replacement of water. When choosing a different source water quality must be

achieve the minimum quality laid down in annex 7 to this Decree

table 1; the source must be sufficient to allow the necessary yield

replacement of water.



(2) to the water from the source to the artificial swimming pool can be used from the

technological or industrial reasons to add minerals. The quality of the

Thus the treated water must comply with the requirements set out in annex 8 to

This Decree.



(3) if the source of tap water for public use,

current data on the values of the monitored parameters in feeding the water from

the operator of tap water. If the water is obtained from another source, or

tap water is not checked in the indicators of total organic carbon,

an operator must ensure that the analyses of the water in the swimming pool resources for

indicators of total organic carbon and nitrates, in order to determine

the increase in the concentration of these parameters in the pool water during operation.



§ 17



Hygiene requirements for swimming pools and bath



(1) the immediate capacity of the artificial rock pools, the indoor area

provides a maximum of twice the capacity as water pools.

The immediate capacity of the area not covered by the artificial swimming pools is determined as

a maximum of five times the capacity of the water of the swimming pools. The derivation of the capacity

from the water of the swimming pools is not artificial swimming pools with exclusively

koupelovými swimming pools or pools for infants and toddlers. The capacity of the water

the area is determined, in part, for non-swimmers area makes for one

non-swimmers 3 m2 and in part for swimmers is the area for one swimmer 5 m2.

The depth of water for non-swimmers may be not more than 160 cm, and must be clearly

marked. For swimming pools with water attractions, water area for one

the visitor sets individually.



(2) An artificial swimming pool with year-round and seasonal operation and a covered

artificial swimming pool must be equipped with a recycling system, which

part of the recirculating water treatment plant, or not covered by the swimming pools

at least continuous disinfection system for the current requirement

referred to in section 25, paragraph. 6. The way of the inflow and outflow of water of each pool

must ensure that in each pool were thorough mixing

water fed into the pool from the water treatment plant with water in the pool. The fulfilment of the

This requirement provides a sufficient number of gating and

drainage elements corresponding to the hydraulic parameters appropriately

spaced, so that when the flow of water in the pool, avoid short-circuit

streams and places with a slow Exchange of water and to Exchange and mixing water

on the short track, intensely enough and in the whole volume of

the swimming pool. In swimming pools must be able to drain the water on

recirculating water treatment plant from both levels, so from the bottom. All

runoff controls in swimming pools must be designed so as to prevent

risk to users of the pool.



(3) the system must not be water pools of the přepouštěna directly from the pool to

the swimming pool. Shall not be considered for release of water attractions, where the water in the

system pools from pool to pool, přepadává, and system pools

connected to a treatment plant, where it is ensured in each pool

a separate tributary of the treated water. The supply of treated water from the recirculation

the treatment must be separate for each pool. If not every day

implemented reading dilutive of water and the value obtained for registered to

the operating journal, must be designed for the supply of water and installed the dilutive

a separate registration with the registration of the meter or the flow measurement of gas

the amount of water.



(4) the pool and storage sink must be in the deepest spot, bear

launching the device in order to drain the water from the pool (sink) in the

sewers, streams or to an appropriate drainage system according to the

their connection to the conditions, and in agreement with its administrators. Must

be assured possibility shock disinfection of all equipment and the swimming pool

water.



(5) if the water from the pool used for the wiring to the showers, you can use

only water at the outlet of the recirculation and its disinfection.



section 18



(1) around all pools must be easily cleaned walkway with

non-slip ^ 3) and with such a differential, that all the water in the

cleaning drain to drainage works, which are operationally

set so that all the water drain into the sewage system. The same

must be carried out and the construction and set up of all operational

other communication areas, which are directly linked to the Gallery; all

the water in the cleaning of these areas must drain so that it does not negatively

affect the quality of the water in the pool. The edge of the swimming pool must be made and

operationally secured so that when cleaning up the observation deck were not dirt

splachovány in the water of the swimming pool or in the recirkulačního system, with

recirculating system and přelivný the Groove pool.



(2) for uncoated pools or between outdoor and indoor gallery

the swimming pool must be the transition of visitors to bypass the pools only through

paddling pools. Footbath must be in the direction of passage of at least 2 m long, with

the wall before and after brodítky, with nástupnou water height 10 cm to 15 cm, and

the constant-intensity corresponding to the flow of water in the Exchange brodítku

at least once per hour. Water to the footbath can be removed from

recirkulačního system after dosing of disinfectant or

use the water running off from the pool to overflow. Footbath must be equipped with

showers, which is headed by the treated water from the recirculation after dosage

disinfectant or water from the tap. These showers are used only

to rinse the body without the use of SOAP and detergent. Paddling pools are regularly

mechanically cleaned and sanitized daily.



§ 19



(1) Materials which come into contact with the pool water (for example,

tiles, covers water, fill the joints, pipes, filters), shall not

affect the quality of water after the physico-chemical or promote growth

micro-organisms. Must not have a negative impact on the efficiency of the disinfection

the pool water.



(2) Equipment used in the swimming training (for example, fins,

pontoons, the buoyancy of the plate), which come into contact with the pool water,

shall not adversely affect the quality of the water and must be resistant to

the physico-chemical properties of the water.



(3) in addition to the swimming pools, a pool for infants and toddlers, they do not

children up to 1 year of age; children aged 1 to 3 years in the pool

only in a swimsuit with a close-fitting rubber around the legs, unless the operator

the pool otherwise.



section 20



(1) the Ventilation of the space above the surface of the pools provides, inter alia,

also defined levels, which may not be less than 30 cm below the

the stands. In the swimming pool level must be established přelivný Groove that

must be adjusted and designed so that the water is returning back to the

the swimming pool. Přelivného Groove length must be at least two-thirds of the omočeného

the perimeter of the pool. In the case of pools deeper than 1.6 meters must be at a depth of 1.2 m u

exterior walls built for the user to secure facilities in the area

width of at least 10 cm.



(2) Přelivné grooves, the walls of the swimming pool and the bottom of the swimming pool must be intact and

easy to clean and it must be mechanically cleaned so that they are permanently

without stop pollution or nárostů.



(3) Artificial swimming pool, which is used as a swimming stadium, must

have places for spectators separated from the space reserved for the

users of the pool; access to these locations must be secured in a special

the entrance and a separate corridor. According to the projected number of viewers must be
available dressing rooms and the required number of toilets with wash basins ^ 3). The floor of the

bleachers for the spectators must be vyspádována to the drain.



section 21



Additional health requirements on the bath the pools



Bath pools with a capacity of up to 2 m3, including daily and must be discharged

mechanically cleaned with subsequent washing with vydezinfikováním and and the newly

filled with filling with water; in the total volume of the swimming pools is calculated and the volume of

the water in the storage tank. Bath pools with a capacity of 2 m3 to 10 m3

must be discharged and cleaned at least once every 2 weeks. For both types of

swimming pools shall be at least once a week and thorough sanitizing surfaces

all technical accessories swimming pool, which is in contact with the

the pool water. Swimming pools with a volume of more than 10 m3 are discharged and

cleaned according to the quality of the water.



section 22



Hygiene requirements for pools for infants and toddlers



(1) General requirements for pools for infants and toddlers:



and) pools for infants and toddlers must have related

areas, in particular indoor, best internal space for prams, cloakrooms

children equipped with changing table or washable pad, separated

space on breastfeeding, rest and acclimatization to the outdoor for kids

environment before leaving, background for the escort (the cloakroom, showers, toilets, etc.),

dry and větratelnou room (the warehouse) on dry storage devices and

materials,



(b) facilities for swimming) infants and toddlers must be structurally or

operationally separated from other premises; during bathing infants or

Toddlers not possible overlapping of activities,



(c)), in which all the premises are parents with children to move,

including areas that come into contact with children, must be at least

Once a day, preferably before each tutorial hour, thoroughly

cleaned using detergent with disinfectant effect; to

disinfection of equipment and the swimming pool you can use just such products, which are

its composition and concentration suitable for health

the workplace (e.g.. infant and neonatal Department of hospitals);

the preparations must take turns as represented by the active active substances and

their application must comply with the required exposure time to

prevent the emergence of drug resistance of bacteria



(d)) toys and AIDS that are used in the pool must be washable,

undamaged, without any holes and removable parts to

they couldn't get the water, with the exception of the openings through which water freely

flows, and appropriate for a given age group; a day after the end of the course

used toys and accessories thoroughly cleaned and disinfected, rinsed

drinking water and saves on a dedicated dry place,



(e)) do not have access to the swimming pools and the sick children sufferers of communicable

diseases,



(f)) in water pollution (stool, vomit, mucus, etc.), as well as in the

any other visible water pollution, traffic is immediately interrupted

to remove the fault; a bathtub or pool is necessary to delete, thoroughly

mechanically clean and disinfect before again with walls and

the bottom and rinsed with clean water,



(g)) for water treatment for infants and toddlers can only be used

disinfectants under the conditions referred to in section 25, paragraph. 9; only for

swimming pool connected to the recirculating system can also use preparations

adjustment of pH and coagulation; ozone can be used for water treatment, provided that the

the dosage will be included in the recirkulačního circuit and the water in the

the pool is no longer contain it. For water treatment you can use algaecides

only for pools operated for over 12 months of age.

The use of other chemical products for water treatment of swimming pools for infants

and toddlers are not allowed; the use of other chemical products

(brighteners, perfumes, algaecides, etc.) for water treatment is prohibited;

disinfectants (chlorine), or other chemicals, dávkují

only in the appropriate places (provided for in the operating procedure) in

recycling system, outside swimming pool, never directly to the pool or to the

floating buoys; ozone can be used for water treatment, provided that the

the dosage will be included in the recirkulačního circuit and the water in the

It will no longer include a swimming pool,



h) UV radiation can only be used in cases when the water in the pool permanently

circulates and the UV emitter is placed in the recycling circuit outside swimming pool; can be

use it only in combination with other disinfectant products pursuant to § 25

paragraph. 9,



I) If is used swimming pool with recycling system is governed by the requirements of the

the intensity of the recirculation and the quantity of water according to the requirements of the dilutive

bath pools (§ 25 paragraph 3 and 6; Annex No. 11 of this Decree),



j) free chlorine content must be kept at a lower level (between 0.2

-0.4 mg/l) in a simultaneous application of other measures, which ensure that the

meet the microbiological requirements (properly functioning water treatment

including coagulation, increased the intensity and variations of water recirculation);

the value of the indicator redox potential depends on the amount of free chlorine,



the climatic requirements for the Hall) swimming pool and adjacent spaces are

listed in annex 12 to this Decree, with the exception of the requirement for the temperature

the air in the lobby of the pool, which is governed by the temperature of the water,



l) if not stated otherwise, is governed by the requirements of the swimming pools for infants and

Toddlers, according to the requirements of the bath the pools.



(2) the Additional health requirements for pools for infants and toddlers, their

operation, replacement of water, water quality and the quality control of water are set out

in annex 10 to this Decree.



section 23



Hygiene requirements for the wading pool



(1) in determining the capacity of the water area children's paddling pool is calculated

with an area of 1 m2 on one child. Wading pool must not have a greater depth of water

than 40 cm.



(2) the way the inlet and water outlet must ensure intensive mixing

the water in the paddling pool and water in a wading pool must not be fed from another

the swimming pool. The intensity of the recirculation must be set so that the entire volume

water changed at least once per hour. Paddling pool with water recirculation

must be at least once a week, dropped, cleaned and surface

disinfected. Paddling addressed without recirculation water must be

discharged, cleaned and disinfected daily.



(3) the requirements referred to in the wading pool in § 18 paragraph. 1 and section 27 of the

Similarly.



section 24



Hygiene requirements for swimming pools operated by the persons providing the care



Hygienic limits of microbiological, physical and chemical indicators

the water quality of swimming pools, which are operated as part of the services

provided by the person providing the care, are listed in annex 8 to this

the Decree.



§ 25



Recirculation, treatment and disinfection of water



(1) the Technology and capacity of the recirculating water treatment plant and its operation

to ensure compliance with the indicators of the quality of the pool water as set out in the annex to

No 8 to this Ordinance.



(2) Recirculating system must be designed and constructed so that all

the water from the system could be discharged into the sewer system or the competent

the drainage system. Device recirculating water treatment plants must allow

easy cleaning of all its components, in particular those which are used to

the separation of the pollution from the pool water. In particular, must regularly clean

přelivné gutters and storage tank. Grid drain installation must

be removable with the possibility of two-sided cleaning and disinfection. All

floor area on the premises of the processing plant must be made and connected

the sewerage system, with the exception of areas where chemicals are stored and

where is handled, and that such measures must be taken to

prevent leakage of these substances into the sewer system.



(3) the intensity of water recirculation and residence time of water for swimming and

the bath the pools shall be determined in accordance with Annex 11 of this Decree;



the intensity shall be continuously measured and recorded automatically for each

swimming pool separately.



(4) in the case of pools with recirculating water treatment plant must be including recirculation

disinfection of swimming pool water in continuous operating time. At the time of production

peace can be the intensity of the recirculation of the pool water is reduced, small

swimming pools and aborted, but the start of operation must be of the recirculation or

filling filling with water at least once replaced the entire volume of the swimming pool. U

equipment intended for the bath can be one visitor after recirculation

for swimming, the visitor to interrupt, if in the time between 2 consecutive swimming

consecutive visitors will be turned on at least recirculation so long to

the entire volume of the water in the pool at least once changed.



(5) for reports of swimming pool water must be divided into recirkulovaná

the individual swimming pools according to their types and operating parameters. U

individual swimming pool with variable depth and different way of use

the quantity of water must be in a regulated according to current needs.



(6) in the case of pools without recirculation in an operating time must be a variation of the water

continuous and proportional to the current number of visitors. Variations of water and

any disinfection measures must ensure compliance with all the requirements on the quality of the

water.



(7) the amount of diluent water must meet the requirements of the spoluzajišťovat

the quality of water provided for in annex 8 to this Ordinance and is governed by the number of

visitors per day, and each visitor must daily
to restructure at least 30 l water in indoor swimming pools, 45 l of water for

indoor swimming pools bath and 60 l of water in uncovered pools and

will. The quantity of water must be measured by the dilutive to separate

the meter or meter registration, with registration of gas

the amount of water.



(8) water intake pool and its completion must traverse

recirculating pool water treatment plant, where the swimming pool treatment

equipped with.



(9) for the disinfection of swimming pool water and limit the occurrence of algae and cyanobacteria can be used

only disinfectants or algicidní the preparations referred to in another legal

the code ^ 8), possibly in combination with physical means of disinfection.

When the use of these products must be complied with the instructions laid down by the manufacturer.

The use of other than the chlor disinfectants is only possible for

provided that their concentration in the pool water will be at least as

effective as the concentration of free chlorine set out in the annex

No 8 to this Ordinance. To determine the effectiveness of the procedure shall be the same

referred to in annex No 4 section and the Decree on the hygienic requirements

products coming into direct contact with water and water treatment ^ 13)

by testing the efficacy of the product also in the test interval 1

minutes of action and that, in parallel with a chlorine test

product with the required concentrations of free chlorine. Disinfection

products (chlorine), or other chemicals, dávkují only to

the appropriate place (provided for in the operating procedure) in

the system outside of the pool, never directly into the swimming pool or in the floating buoys.



section 26



The quality of the water in swimming pools, artificial swimming pools



(1) the water in the pools of the artificial swimming pools must be adjusted so that its

use avoid damage to human health, in particular by

germs (pathogenic or conditionally pathogenic agents of origin

bacterial, viral or protozoálního or pathogenic yeast,

mold or toxic cyanobacteria). The pool water is not vyplavovat

organisms that can reproduce on the filters or in other stage

editing.



(2) in the water in swimming pools, artificial swimming pools, chemical substances, including

those that have been used or originated in the editing processes, disinfection

and recirculation of the pool water, may be present in concentrations that would

may cause damage to human health.



(3) the requirements for the quality of the water in swimming pools, artificial swimming pools are

set out in annex 8 to this Ordinance.



section 27 of the



The place for sampling water



(1) in the case of pools with a length of more than 26 m for microbiological analysis

a separate sample taken at the entrance to the pool, and after a separate sample

in all 4 corners of the swimming pool; If it is located in the corner of the pool water inflow

in the pool, the sampling place moves for tributary. In the case of 5 consecutive

following satisfactory microbiological findings for

microbiological examination, in addition to the sample on a tributary, just remove the 2

samples from opposite corners of the swimming pool; in the case of unsatisfactory,

the number of samples again increased to 4. Legionel can be used for the examination of the so-called.

slévaný pattern that is obtained by mixing the water collected in the 4 corners and

tested as the sole pattern. For the analysis of the chemical parameters, which

do not set in place, removing slévaný from all 4 corners of the sample pool.

Measurement indicators set at the place of sampling shall be carried out in formulas

taken from a single place, or these indicators set probe

submerged directly into the pool water. Indicators, which are continuously

measured in the probe, the selected sample analysis carried out by the

do not specify the operator.



(2) For the microbiological analysis of water from swimming pools to a length of 26 m, including the

a separate sample taken at the entrance to the swimming pool and one sample for

two opposite shorter sides of the pool, but not near

the inflow of water into the pool. Legionel can be used for the examination of the so-called. slévaný

the sample, which is obtained by mixing water collected on two opposite

the shorter sides and tested as a single sample. For the analysis of chemical

indicators, which are not on the site, is taken from the slévaný sample

the subscription for two opposite shorter sides of the pool. Measurement indicators

charged at the place of sampling shall be carried out on the samples taken from

one place, or these indicators establish the probe submerged

directly into the pool water. If the pool is equipped with hydro-massage

the circulation circuit, sampling shall be carried out in the mode turned on

circulation circuits after at least 5minutovém. Indicators,

which are continuously measured in the probe, the selected sample analysis

conducted by the operator do not constitute.



(3) in the case of pools of irregular shape with flat levels greater than 500 m2

proceed as in paragraph 1, in the case of irregular shape with swimming pools

flat levels of 500 m2 and smaller proceed as in paragraph 2 with

the fact that the place for sampling shall be individually so that the

sufficiently representative of the quality of water in the entire pool. To

the determination is appropriate to use eg. ink test according to technical

^ 9 standards), which explores how the flow of water and the effectiveness of the Exchange and

mixing of water in the pool and marks the place of risk in terms of the quality of

water, where the sample should be taken. To perform this test is appropriate

also for other pools.



(4) for pools with a volume of less than 2 m3 for microbiological and

chemical analysis of a separate sample taken at the entrance to the pool, if

It is technically possible, and one sample in the middle of the pool. If the pool is

equipped with a hydro-massage circuit loop, sampling shall be carried out in

based on the mode of closed-circuit after at least 5minutovém

operation.



(5) water samples are taken from the pool of 15 cm below the surface. Samples

the treated water is taken from the sample of the outlet valve equipped

on the pipe before its entry into the pool. If it is in the area of the swimming pool

multiple swimming pools and all is channelled water from common water treatment swimming pool

water, take a sample of treated water from just one place.



(6) subscriptions are implemented for the operation of the swimming pool; first 3 hours after

the start of operation, if it is on the checks carried out by the operator,

or at any time during operation, if it is on the checks carried out in the framework of the

the State health supervision. If the operation of the pool less than 3

hours, the time between the start of the operation and the collection of shorten. proportionately



(7) When the sampling of the water and the determination of indicators of the quality of water

proceed according to Czech standards ČSN EN ISO 5667-1 (75

7051) water quality-sampling, part 1: instructions and program design collection

sampling and sampling methods, ČSN EN ISO 5667-3 (75 7051) Quality

water-sampling-part 3: instructions for the preservation of the samples and the handling of

them, ČSN ISO 5667-5 (75 7051) water quality-sampling-part 5:

A guide for the sampling of drinking water from water treatment plants and water supply networks,

ČSN EN ISO 19458 (75 7801) water quality-sampling for the

microbiological analysis, if in this Ordinance, unless otherwise specified.



section 28



Review and evaluation of the quality of the water in the swimming pool with an artificial swimming pool



(1) the requirements for frequency control are laid down in annex 9 to this

the Decree. If there is no monitoring of the values of the content of free and

bound chlorine and redox potential of continuously automatic measuring and

the registration system in the pool or on the runoff water from the swimming pool, the

These values in the water of the swimming pool 1 hour before the start of operation and

every fourth hour. The correct operation of the equipment without disinfectant

automatic error report is checked 1 hour before the start

operation and at least every other hour.



(2) monitoring of the microbiological parameters in the water before entering the

the pool and the water of the swimming pool shall be carried out in the frequency set out in the annex to

No 9 of this decree with the reference methods of measurement listed in

Appendix 8 to this Ordinance. Demonstration of the equivalence of non-reference

methods of laboratory control of water microbiological parameters is carried out

the method set out in article 7.2 of the ČSN EN ISO 17994 (75 7016)-water quality-

The criteria for the determination of equivalence of two microbiological methods.



(3) the quality of the water in the pool is also tentatively checked at least three times

daily monitoring of the transparency of the indicators in the deepest part of the pool water

the swimming pool. The temperature of the water in the swimming pool and the air temperature is measured at least in the lobby

three times a day, before operation and after 4 and 8 hours of operation,

and is on the Board, located in a visible place, or other

conclusively.



(4) the results of the checks the values provided in the indicators of the quality of pool water

carried out by the operator must be recorded in a production journal

or an electronic database. Furthermore, it must be in the production journal

recorded the start time of the operation.



(5) the Protocol on results of laboratory checks must be passed to 4

working days from the date of the sample to the competent authority of the protection

public health. In the event that the subscription is carried out on the establishment of

indicators



Legionella spp.

must be passed to the result of this determination no later than the 14th day after the

the implementation of sampling.



section 29



In the area of artificial swimming pool it is necessary to ensure the distribution of drinking water.



section 30



The dressing room of the artificial swimming pools and saunas
(1) the capacity of the dressing rooms must match the capacity of the artificial swimming pool. The capacity of the

the dressing room of the sauna must correspond to twice the number of places heating rooms (section 35).



(2) for uncoated artificial swimming pools can be used instead of the dressing rooms to build

changing cabins. Floor area of the one changing cabins for uncoated

even the indoor swimming pools must be at least 1.5 m2.



(3) dressing rooms with indoor artificial swimming pools must be operationally separated for

visitors who go to bathe, from other visitors.



(4) the number of showers is governed by an estimated capacity of swimming pool. For indoor

artificial swimming pools must be maintained for the coming of the order of the dressing room, space

for showering, swimming pool, swimming pool for the departure order, space for showering,

osušovna, dressing room, and these sections must be structurally separated.



(5) the floors and walls of the dressing rooms shall be of smooth, easy to clean

the material. The floor must have an antislip finish ^ 3) and must be

a sufficient fall towards the odvodňovacímu of the system. The Division shall be

completed at least 15 cm above the floor, corners and corners of the perimeter walls must

be rounded. For newly built or renovated buildings must be

corners and corners between the walls and corners rounded.



(6) the equipment of the dressing locker rooms and dressing cabins must be

nenasákavé and easily washable.



(7) the Cabinet for clothes and footwear shall be of smooth, moisture-resistant

material and changing rooms indoor swimming pools and saunas must be well větratelné.



section 31



Showers and toilets, artificial swimming pools and saunas



(1) for the indoor artificial swimming pools must be assured for 15 visitors

at least 1 shower, artificial swimming pools not covered by at least 1 shower for

100 visitors; in the sauna at least 1 shower on 4 places in increasing their heating rooms.

A shower of artificial swimming pools for men and women must be separated by ^ 3). In

the case of a small number of the device to not more than 6 visitors it is possible to establish

showers are common.



(2) Wall space for showering must be fitted with easily washable

the surface to a height of at least 2 m ceilings and walls in the shower shall be above the

washable parts whitewashed plaster with protiplísňovým.



(3) the toilets are placed so that the visitor when you return to the pool

Hall walking space for showering. If the toilets will be placed

also right next to the pool must be equipped with shower. Their number and

the arrangement sets out the specific legal provisions that govern the technical

the requirements on the construction of ^ 3). In the case of small equipment to the number of not more than 6

visitors can set up a common toilet.



(4) the floor space for shower and toilets must be easily

washable and easy to disinfect with non-slip

editing ^ 3), with space for showering made in the direction of the

odvodňovacímu system, whose position must ensure good conditions for the

maintenance. For newly built or reconstructed buildings and corners must be

the corners between the walls and corners rounded.



§ 32



Cleaning



(1) an artificial swimming pool and the sauna must be kept clean. Toilets

including chairs, space for showering and dressing room must therefore be cleaned

and disinfected, as appropriate, for the operation of the device at least once

daily. The used disinfectants must rotate under represented

effective active substances and their application must comply with the prescribed

the exposure time, to avoid unwanted resistance

biological agents.



(2) for newly built or renovated buildings must be established

cleaning the room ventilated, equipped with a sink with water battery

for hot and cold water. The walls must be fitted with easily washable

the surface to a height of at least 180 cm from the floor.



section 33



The requirements on the microclimatic conditions, lighting and indoor air

the pool hall



(1) the requirements on the microclimatic conditions, lighting and indoor air

the pool hall, indoor swimming pools are listed in annex 12 to this

the Decree.



(2) for holding swimming competitions or other organized events in the

length 50 m pools with artificial lighting intensity control technical

^ 11) standards.



(3) all rooms and spaces of objects covered and not covered by the artificial

swimming pools must be ventilated; If not enough natural air exchange

Windows, exchange of air must be ensured in mechanical ventilation. Ventilation

toilets must be vacuum.



§ 34



Room, sauna



(1) space heating rooms for one person must be at least 2 m ^ 3.

Room must be well insulated with a moisture barrier.

The properties of the materials used in increasing their heating rooms must not be under the influence of heat and

the moisture change.



(2) the walls and ceiling heating rooms, tiled the material well insulating carpet

the heat and humidity well absorbujícím, best quality from the wood

on the surface, unlucky obroušeným without bearings. The doors are made of transparent

material or over the window, with a wooden handle from both parties and

must open outwards, without the use of interlocking sklapky. The door must reliably

to allow exit from the heating rooms. No wood in increasing their heating rooms must not be

impregnováno, napuštěno, or nalakováno, with the exception of outdoor areas

doors and walls.



(3) the Room must be equipped with at least one degree of wood

pryčen with a width of at least 50 cm, while the top grade must be located

at least 120 cm from the ceiling. Per person, according to the capacity of the heating rooms counts

1 m length of the platform. The seating areas shall be constructed of lath

attached from the bottom or with sunken and covered the heads of the screws.

Individual parts of the platforms must be removable with a maximum weight of 15

kg. In increasing their heating rooms must be no metal objects, or parts, are

that could saunující the person come into contact.



(4) the flooring must be well washable with non-slip materials

editing ^ 3) and vyspádována to the floor drains. Floor drain is placed

outside of space heating rooms, sauna door threshold or the machine is not making

leaving free space underneath to allow drainage of water from the

When cleaning heating rooms. In the case of the placement of floor drains in the

increasing their heating rooms must admit its design to prevent intrusion

smells from the sewerage system in heating rooms.



(5) the Sauna heater must be secured against accidental touch

saunujících persons. The transfer of excessive radiant heat into the space must

be limited by the construction of the heaters or the appropriate covers. The heaters on fixed

or gas to space heating rooms placed only the heat

heat exchanger, or construction of the heaters must ensure only service

outside heating rooms. The flue and related equipment must be placed

outside of space heating rooms.



(6) the Room must be sufficiently větratelná, with the possibility of regulation.

Must be sufficiently lighted and equipped with emergency lighting.

Illuminators must be located so as to avoid risks

saunujících persons.



section 35



Shower and sauna



(1) to cool the body establishes the external or internal shower,

or both at the same time.



(2) the internal ochlazovnu forming a cooling shower, possibly in combination with the

cold water pool or other cooling device. The swimming pool and

shower facilities are located inside the object, in the vicinity of the

heating rooms. The walls and floor of the pool must be equipped with a well rounded

the surface. The surface must be smooth and non-slip nepórovitý

DNA. The swimming pool must be equipped with a water level of přelivným groves, with

discharges to water treatment of the pool water, or through the sifonový CAP, if the mouth

into the sewers. During the operation of the swimming pool water must be continuously supplied to

the bottom and drain overflow. The bottom of the incline to the výpustnímu must have a hole. The entrance to the

the pool must be equipped with steps, handrails or input the ladder with

handrails. The floor around the pool must have an antislip finish ^ 3)

drain pipe to the floor the Bureau.



(3) the water in the swimming pool or the water to the shower in the ochlazovně must match the

the requirements for pool water in artificial lakes with

the exception of temperature and must perform a cooling effect. The chemical and

microbiological water analysis is carried out once a month in the range

specified in annex 8 to this Ordinance. Chemical examination, with

the exception of the determination of the content of free chlorine in swimming pools equipped with

disinfectant device is not required in the case of swimming pools, in which

the water is constantly and in proportion to the traffic daily changed drinking water, and

at least 30 l per visitor saunas, which are daily

cleaned and newly populated. In the cool-down the showers, which are

linked to the distribution of drinking water, it is not necessary to perform a chemical or

microbiological water analysis.



(4) the water in the pool can recycle only if its standing

disinfecting and continuous replacement of water in quantities of at least 30 l dilutive

water on the visitor's day. The concentration of free chlorine must be

maintained in the range of 0.3 mg/l up to 0.6 mg/l of water, and at least once

checked daily. If the cooling swimming pool equipped with a recirculating

the water treatment plant, its operations are subject to the provisions as to the swimming

swimming pools.



(5) the external ochlazovnu make up the outdoor space for cooling of the body of water

or air coupled with other areas. It is equipped with
benches from the smooth, easily cleanable material, and in the case of the establishment of the

the swimming pool in the outer ochlazovně this pool must conform to the requirements of this

the Decree. For the winter season is necessary to ensure access to communication

the pool against namrzání, or otherwise secured against injury caused by

slipping.



section 36



Rest room sauna



The size of the rest rooms must be at least 2 m2 in one place

heating rooms. Rest room must be equipped with chairs or armchairs in a number of

the corresponding capacity heating rooms, with washable surface. The floor in the

the rec room must be easy to clean. The air temperature is indicated in the

Annex No. 13 of this Decree.



§ 37



Additional requirements for spatial resolution of saunas



(1) for the storage of detergents and disinfectants shall be established

the eraser room, větratelná, equipped with a sink with water battery

for hot and cold water. The walls must be fitted with easily washable

the surface to a height of at least 180 cm from the floor.



(2) in the saunas with picking clothes must be clean and the linens are stored

separately in a special area. If it is not used linen a day shipped

the laundry room must be made for the possibility of its drying in a room to

to this end, dedicated; You can also use the premises after the end of

service for visitors, with the exception of the space heating rooms.



section 38



Climatic conditions of saunas



(1) the requirements on the climatic conditions and the lighting of the saunas are

regulated in annex 13 to this Decree.



(2) in increasing their heating rooms must be installed at least one thermometer with

up to 130 ° c, which must be located at least 1 m from the thermal

resources, up to a maximum height of 200 cm above the floor.



section 39



Cleaning and cleaning the sauna



(1) at least once a day, and especially after the end of the operation, must

all sauna facilities wash water with detergent and

disinfected. Floor heating rooms and bunks must be regularly wipe off

clean water, at least twice daily during the operation. Doors, washable

parts of the walls, the cloakroom cabinets and other furniture, radiators, heating, etc.

the sanitized at least once a week. Room is clean,

disinfect and ventilate the rule after the end of the second day of operation, and must

keep the door open.



(2) water from the ochlazovacího pool without recirculation, a day after the end of

traffic discarded, the walls and the floor shall be mechanically cleaned, disinfected

disinfectant and them properly with clean water. Swimming pools with

recirculation shall be mechanically cleaned at least once a week.



section 40



Sand in outdoor gaming areas hookworm is



Hygienic limits of chemical, microbial and parasitic contamination

the sand used to games children in hookworm is on outdoor playing

areas designated for the games the children are regulated in annex 14 to this

the Decree.



§ 41



Transitional and final provisions



(1) in the assessment and classification of the microbiological analyses shall

pursuant to section 9 (2). 3 the second and third sentences until 31 December 2004. December 2014.



(2) the provisions of § 20. 1 third sentence applies to newly constructed buildings

After the date of entry into force of this order or the building reconstructed.



(3) until 31 December 2006. December 2012, you can place the TOC indicator referred to in annex No.

8 of this Decree to follow pointer COD-Mn with limit value in

pool water during operation 2 mg/l over the value of the filling of water; absolute

the value in the water before entering the pool should not exceed 3 mg/l.



section 42



Cancellation provisions



Shall be repealed:



1. Decree No. 135/2004 Coll., laying down the health requirements for

the swimming pool, the sauna and the health levels of sand in the hookworm is outdoor

gaming areas.



2. Decree No. 292/2006 Coll., amending Decree No. 135/2004 Coll.

laying down public health requirements for the swimming pool, the sauna and the

hygienic limits of sand in outdoor gaming areas hookworm is.



§ 43



The effectiveness of the



This Decree shall take effect on the date of its publication, with the exception of section 12 of the

paragraph. 1, which shall take effect on the date of 24. March 2012, and § 25 paragraph. 3

part of the sentence for a semicolon, which shall take effect on 31 December. December

2015.



Minister:



doc. MUDr. Heger, CSc., r.



Annex 1



Microbiological indicators of water quality in natural pools

operated on surface waters, other surface waters to

swimming and bathing water areas resulting from mining activities



-------------------------------- --------------------------------------------------------------

A B C D E

-------------------------------- --------------------------------------------------------------

indicator of Excellent, good, acceptable reference methods

quality quality quality analysis

-------------------------------- --------------------------------------------------------------

1 200 intestinal enterococci (*) 400 (*) 330 (**) the ČSN EN ISO 7899-1 (***)

(CFU/100 ml), or EN ISO 7899-2

-------------------------------- --------------------------------------------------------------

2 Escherichia coli (CFU/100 ml) 500 (*) (*) 1 000 900 (**) ISO 9308-EN 3 (***)

or ČSN EN ISO 9308-1

-------------------------------- --------------------------------------------------------------



(*) On the basis of the evaluation of the 95. percentile.



(**) On the basis of the evaluation of the 90. percentile.



(***) In the case of the use of these methods is given in units of

MPN MPN/100 ml. (most likely means the number of most probable

number).



When percentilovém processing log-normal density

probability (decimal logaritmech) microbiological data

obtained from a single monitoring point values percentilů provides

as follows:



1. For each value of the assembled data file, the value is calculated

logarithm (log10). If a zero value is detected, the

Instead, the base-10 logarithm of the lowest limits of detection of the used

the analytical methods.



2. Calculate the arithmetic mean of the values of logaritmovaných (my)



3. Calculate the standard deviation of the values logaritmovaných (sigma).



4. The value of 90. and 95. percentile of the data probability density

be calculated from the following relations



and) 90. percentile = antilog (my + 1,282 sigma) = 10 (my + 1,282 sigma).



(b)) 95. percentile = antilog (my + 1.65 sigma) = 10 (my + 1.65 sigma).



Annex 2



The rules for the handling of samples for microbiological analyses of water in

natural swimming pools operated by the surface waters, other

surface waters for swimming and bathing water areas arising

mining activities



1.



Instead of sampling



Samples shall be taken from a depth of 30 cm below the surface, in the water, which has

the depth of at least 1 metre.



2.



Sterilization containers for samples



Sample containers must:



-be sterilized in an autoclave at 121 ° c for at least 15 minutes

or



-to undergo dry sterilisation at between 170 ° c +/-10 ° c for at least 1

hours or



-to be irradiated sample containers taken directly from the manufacturer.



3.



A sampling of the



The volume of the sample container depends on the amount of water needed for each

controlled pointer. The minimum content is generally 250 ml. Container

the samples must be of transparent and non-coloured material (glass,

polyethylene or polypropylene). In order to prevent accidental contamination of the

the sample, the sample use hygienic procedure, in order to

maintain the sterility of the samples. Proceed to properly, it is not

need another sterile equipment (such as sterile surgical

gloves, use pliers or rods), however, should also be avoided

contamination of the water abstracted from the recipient. The sample must be clearly

Mark indelibly on the container of the sample and on the

sampling.



4.



Storage and transport of samples before analysis



Water samples are to be protected during all stages of transport from exposure to

the light, in particular direct sunlight. The sample is to be up to

arrival to the laboratory, keep in a cool box or refrigerator

(according to weather conditions) at a temperature of around 4 ° c. If the transport

in the laboratory, probably longer than 4 hours, transport is needed in

the refrigerator. The time between sampling and analysis shall be performing

the shortest. It is recommended to perform an analysis of a sample of the same business day.

If this is not possible, for practical reasons, the samples are processed by

24 hours. In the meantime, kept in the dark at a temperature of 4 ° c +/-3 ° c.



Annex 3



Assessment and classification of bathing water in the natural pools

operated on surface waters, other surface waters to

swimming and bathing water areas resulting from mining activities from the

microbiological point of view



Poor quality



Bathing water is classified as "poor", if they are in the file

data on the quality of bathing water for the last assessment period values

90. the percentile results, microbiological parameters referred to in annex

No 1 to this notice are higher than the values for "acceptable quality"

laid down in column D of annex 1 to this notice.



Acceptable quality



Bathing water is classified as water with the "acceptable quality":



1. If the file data on the quality of bathing water over the last

the period under examination the value of 90. percentile of the results of the microbiological
indicators of the same or lower than the value for "acceptable quality"

laid down in column D of annex 1 to this notice and



2. If the bathing water is vulnerable to short-term pollution, under the

the condition that:



I) adequate management measures, including surveillance, the system

early warning and monitoring, in order to use the alert or

where appropriate, the prohibition of bathing there are bathers are exposed to

pollution,



(ii)) management measures are adopted to prevent the causes of

pollution or to reduce or eliminate these causes, and



(iii) the number of samples), from where it was during the last period considered

apart because of short-term pollution, does not constitute more than 15

% of the total number of samples, as specified in the monitoring calendar,

for that period, or no more than one sample in the bathing season, according to

that number is higher.



Good quality



Bathing water is classified as "good":



1. If the file data on the quality of bathing water over the last

the period under examination the value of 95. percentile of microbiological parameters

equal to or lower than the value for the "good quality" set out in column

(C) of annex 1 to this notice and



2. If the bathing water is vulnerable to short-term pollution, under the

the condition that:



I) adequate management measures, including surveillance, systems

early warning and monitoring, in order to use the alert or

where appropriate, the prohibition of bathing there are bathers are exposed to

pollution;



(ii)) management measures are adopted to prevent the causes of

pollution or to reduce or eliminate these causes, and



(iii) the number of samples), from where it was during the last period considered

apart because of short-term pollution, does not constitute more than 15

% of the total number of samples, as specified in the monitoring calendar,

for that period, or no more than one sample in the bathing season, according to

that number is higher.



Excellent quality



Bathing water is classified as "excellent":



1. If the file data on the quality of bathing water over the last

the period under examination the value of 95. percentile of microbiological parameters

equal to or lower than the value for the "excellent quality" as set out in the

column (B) of annex 1 to this notice and



2. If the bathing water is vulnerable to short-term pollution, under the

the condition that:



I) adequate management measures, including surveillance, systems

early warning and monitoring, in order to use the alert or

where appropriate, the prohibition of bathing there are bathers are exposed to

pollution,



(ii)) management measures are adopted to prevent the causes of

pollution or to reduce or eliminate these causes, and



(iii) the number of samples), from where it was during the last period considered

apart because of short-term pollution, does not constitute more than 15

% of the total number of samples, as specified in the monitoring calendar,

for that period, or no more than one sample in the bathing season, according to

that number is higher.



Annex 4



Table 1:



Indicators and limit values for the natural swimming pool operated by the

on surface waters, other surface waters for bathing and water

bathing areas resulting from mining activities have increased

probability of cyanobacteria



------------------------------------- -------------------------

The Indicator Unit Limit Endnotes

------------------------------------- -------------------------

1 transparency m 1 1

2 water level 0 flower 2

------------------------------------- -------------------------



The explanatory notes

:



1. If it is obviously reduce transparency caused by inorganic

particles, it is not necessary to initiate monitoring of cyanobacterial according to table 2.



2. determination of sampling shall be carried out according to ČSN 757,717, where is the

listed below are the scale:

-------------------- -----------------------------------------------------------------

Degree Of Occurrence Description

-------------------- -----------------------------------------------------------------

0 No Cyanobacteria are not observable by the naked eye



1 Observable in water are detectable rare green flakes, kolonienebo

the individual threads.



2 Large shore appear weaker příhladinové clusters sinicnebo

It is in the water column, with a greater amount of koloniínebo

the individual filaments of cyanobacteria.



3 Mass occurrence of strong příhladinových the flowers of great magnitude. On the shore

larger quantities may be naplaveno green kašovitého

the material.

-------------------- -----------------------------------------------------------------



Table 2:



Indicators and limit values for the natural swimming pool operated by the

on surface waters, other surface waters for bathing and water

bathing areas resulting from mining activities, with an increased risk

the emergence of mass development of cyanobacteria



-------------------------- ----------------------------------------------------------------------

The indicator Unit and level II. grade III. the degree of explanatory notes

-------------------------- ----------------------------------------------------------------------

1A cyanobacteria cells/ml, 20 0000 100 0000 250 0000 1 5

1B cyanobacteria mm3/litre, 5 2 10 20 1

2 chlorophyll-and mikrog/l 10 50 100 2, 5

3 water flower stage 2 3

4 microscopy 4

5 transparency 6 m

-------------------------- ----------------------------------------------------------------------



The explanatory notes

:



1. just the expression of only one way (cells/ml or cellular

the volume). The determination is carried out according to CSN 75 7717.



2. the determination is carried out according to the standard ISO 10260 (75 75757). If there is a

determination of chlorophyll-a and is performed using the method that allows you to differentiate

cyanobacteria from seaweed (fluorometrie, HPLC), it is not necessary to perform a microscopic

quantification of cyanobacteria and the determination of indicators is sufficient "microscopic".



3. the determination is carried out in sampling according to ČSN 757,717 (see

explanatory note 2 in table 1).



4. the "microscopic" contains a verbal description, in which they are

listed above all the dominant taxa of cyanobacteria, the dominant representatives

phytoplankton and any other information that can contribute to the

interpretation of the results.



5. Limits for III. the degree of concern the cyanobacteria, which do not constitute a significant water

the flowers typically



Planktothrix agardhii

. If you are the dominant species of filamentous cyanobacteria nanoplanktonní (typically from

the genera



Pseudanabaena, Limnothrix

) is necessary to establish the cyanobacteria as the volume of biomass (indicator 1b).



6. evaluation of the measured values shall be carried out in the context of the cumulative assessment

results in accordance with annex 6 to this Ordinance.



Table 3:



The procedure, if the previous guest in the swimming season in progress

for limit values have been exceeded (III). the degree of

--------------------------------------------- ----------------------------------------

Prior to the current values of explanatory notes Made

the guest match guest

--------------------------------------------- ----------------------------------------

III. stage III. grade III. the degree of

III. stage II. grade II. the degree of

III. level I level II. the degree of

III. level I and level = 770 720 > = 15, 16, 17

----------------------------------------------- -------------------------------------------------------------------- -----------------------



*) Highest hurdle occurs when any of the

the following terms and conditions:



1. the value of the Escherichia coli more than 10 CFU/100 ml, and at the same time more than

100 CFU/ml for the number of colonies in the 36 ° c, and/or more than 10 CFU/100 ml

for Pseudomonas aeruginosa,



2. the value of the Pseudomonas aeruginosa is greater than 50 CFU/100 ml or values

Pseudomonas aeruginosa is greater than 10 cfu/100 ml, and at the same time and counts

the colony at 36 ° c greater than 100 CFU/ml number of colonies at 36 ° c.



Explanatory notes:



1. Method of measurement according to ČSN EN ISO 9308-1-or method

Colilert ®-18/Quanti-Tray ®.



2. Method of measurement according to ČSN EN ISO 6222.



3. Method of measurement according to ČSN EN ISO 16266.



4. Indicator of the Staphylococcus aureus is designed for the needs of the Decree

the method of determination in accordance with ČSN EN ISO 6888-1 (without changing the A1) in point 4.1, the

instead of vaccination technology uses membrane filtration, water 100 ml of sample.



5. Method of measurement according to ČSN ISO 11731 and ČSN ISO 11731-2. Examination on the

the presence of the legionel is not needed if the water temperature is

permanently lower than 23 ° c. For swimming pools operated by the persons providing

care recirkulovaná water at the entrance to the swimming pool and in the shower shall comply with the

a value of 0 cfu/100 ml.



6. In the Protocol on the results of laboratory inspections result shall indicate the

the unit according to the methods used for the determination of: ZF ZF (t) or (n), where t

means turbidimetrickou and n nefelometrickou method. For swimming pools

operated by the persons providing the care filled with water from the natural

medicinal resources, take into account the derogations resulting from specific

the natural properties of these waters.



7. In justified cases, it is possible to admit a wider range of pH, not

However, higher than pH = 9.5 and lower than pH = 6; the range of values is 6.5-7.6

optimal for efficient disinfection. If it is not carried out

measurement of pH automatically continuously, the determination of the place at

sampling. For swimming pools operated by the persons providing the care

nedezinfikovaných chlorine can accept different values if the
It is a source of natural medicinal water with a pH of naturally higher or

lower.



8. Filling the water must not be higher than the contents of the TOC is a hygienic limit for

drinking water (5 mg/l), in terms of minimizing the formation of undesirable

the by-products of disinfection is recommended in TOC in filling water

What is the lowest (up to 1 mg/l). The real measured value shall be entered

TOC total organic carbon in the water in the pool (the pointer can be

marked as "TOC"). If it is determined in the context of the collection and the analysis also

the value of total organic carbon in water filling, it is necessary to also

specify the pointer to the "TOC-the difference", where will be placed the value of the "TOC" in the pool after

subtracting the value of the "TOC" in filling the water for swimming pools.



9. Apply for swimming pools and pools operated by persons

providing care with the water temperature not exceeding 28 ° c. For children's

the pools will is appropriate, regardless of the temperature of the water content

free chlorine in water with regard to the higher sensitivity of a child's organism

against chlorine in the lower value of the moving range, IE. When the value of the

0.3 mg/l.



10. Apply for the bath the pools and pools operated by persons

providing care with temperature not exceeding 32 ° c.



11. Apply to the bath the pools and pools operated by persons

providing care with a temperature higher than 32 ° c.



12. the determination is carried out at the place of sampling. For water containing

bromides and iodides are determined free halogen content, expressed as chlorine. Are

tolerated deviation from the limit values up to +/-20%.



13. The determination is carried out at the place of sampling. Calculated on the basis of the

the difference between the total chlorine and free chlorine. For water containing

bromides and iodides are determined as chlorine bound halogen.



14. only in the case of the use of ozone in water treatment. It is measured

only at the entrance to the swimming pool.



15. measured electrode with Ag/AgCl 3.5 M KCl. The measured values are given

only with the indication of the appropriate electrodes or equivalent. Expressed as

the measured value the potential of ODA (M) against the selected reference electrode

(Ag/AgCl 3.5 mol/lKCl) at a temperature of 25 ° c. In the case of other conditions

the result must be recalculated. The determination is carried out as a priority in the

stationary measuring and registration devices with continuous

the measurement.



16. The use of other than the chlor preparations and for water with a share

chlorides > = 5000 mg/l, as well as for water containing bromides and iodides in

quantity > = 0.5 mg/l, a value is required for the redox potential

determine experimentally.



17. swimming in pools for infants and toddlers shall be the value of the redox

potential > = 680 mV for the range pH 6.5-7.3 and > = 700 mV for a range of pH

7.3-7.6. These values need not be maintained in pools without recirculation,

that's drinking water, and in which the water is changed after the

each time you use or to which drinking water flows continuously.



18. In the case of the use of ozone in water treatment applies a limit for nitrates

the value of 30 mg/l over the value of the filling of water. The following shall be entered in real terms

the measured value of nitrates in the water in the pool (the pointer can be marked as

"NO3"). If it is determined in the context of the collection and the analysis of the value

nitrates in the water fountain, it is necessary to also include the pointer "NO3-difference",

where will be the value of "a" in the pool after NO3 subtracting "NO3"

filling the water for swimming pools.



19. Does not apply to nedezinfikovatelné the water in swimming pools operated by the

the persons providing the care.



20. the measurements shall be made only in the case that is used for the disinfection of swimming pool water

chlorine dioxide. This is the sum of the two substances.



21. Applies to pools where swimmers race training, and other

sports and educational activities that take place over 2 days in

week.



22. Apply to all pools except for the pools listed in the explanatory notes

No 21.



Annex 9



Check the water quality of the artificial swimming pool



--------------------------------- -------------------------------------------------------- -----------------

The frequency parameter controls the explanatory notes

--------------------------------- -------------------------------------------------------- -----------------

˘

the content of free and bound chlorine an hour before the start of the operation and every fourth hour 1

(when using the product on the basis of

chlorine, chlorine dioxide),

other, chloritanů and bound

(when using chlorine dioxide

chlorine dioxide), active ingredients

Another disinfectant and

to him the appropriate side

products for disinfection (when using

other products)

--------------------------------- -------------------------------------------------------- -----------------

redox-potential of an hour before the start of the operation and every fourth hour 1

--------------------------------- -------------------------------------------------------- -----------------

the temperature of the water in the pool three times daily 1

--------------------------------- -------------------------------------------------------- -----------------

the transparency of the continuously, but at least three times daily 1

--------------------------------- -------------------------------------------------------- -----------------

Ph once a day 1

--------------------------------- -------------------------------------------------------- -----------------

turbidity once per 14 days 1.2

--------------------------------- -------------------------------------------------------- -----------------

nitrates once per 14 days 1.2

--------------------------------- -------------------------------------------------------- -----------------

total organic carbon once a month 3

(TOC)

once every 14 days 4.5

--------------------------------- -------------------------------------------------------- -----------------

ozone once a month 1

--------------------------------- -------------------------------------------------------- -----------------

microbiological indicators: at least once a month or according to the instructions of the protection authority 3

Escherichia coli, the number of colonies of public health

at 36 ° c, Pseudomonas aeruginosa

at least once every 14 days or according to the instructions of the authority 4.5

the protection of public health

--------------------------------- -------------------------------------------------------- -----------------

Legionella spp. once every 3 months 3

Once a month 4

once every 14 days 6

--------------------------------- -------------------------------------------------------- -----------------

Staphylococcus aureus once every 3 months 3

Once a month 4

--------------------------------- -------------------------------------------------------- -----------------

(1) the absorbance A254 continuous measurement or 7 as appropriate

--------------------------------- -------------------------------------------------------- -----------------



The explanatory notes

:



1. monitoring of the parameters whose determination is carried out daily on the site (pH,

free chlorine or other disinfectants, bound chlorine, chloritany,

chlorates, redox potential, the temperature of the water and the air, transparency) or

the determination can be carried out on the spot using portable

the spectrophotometer and commercially produced sets (nitrates, turbidity), may not

the operator shall leave the lab, ensure that the authorized accredited

laboratories or laboratories who holds a certificate of good

activities of the laboratory. The establishment of these indicators must be carried out

correctly according to the instructions of the manufacturer of measuring equipment and measuring functionality

the equipment must be checked regularly. The holder of a certificate referred to in section 6 c

paragraph. 1 (a). and once a month) will make the determination of indicators of free and

bound chlorine, turbidity, pH, nitrates, chlorates, chloritany, TOC, or.

ozone.



2. The frequency of inspections of the indicators may be clouding and nitrates in the case that the

the pool is released daily and filled with filling water, reduced to one

on a monthly basis.



3. Applies for swimming pools, swimming pools operated by persons

providing care and pools with natural healing source with water temperature

to 28 ° c.



4. Apply for the bath the pools for swimming pools operated by persons

providing care and pools with natural healing source with water temperature

above 28 ° c. If you are not in a swimming pool installed generating device

aerosols, such as bubble hot tubs, waterfalls, geysers, fountains,

neck showers, etc., is carried out examinations on the presence of legionel only

in the water at the entrance to the swimming pool.



5. in the case of continuous measurements of pH, disinfectant,

redox-potential and pH adjustment and automatic dosage

disinfectant, or in the event that the pool is released daily and

filled with filling with water, it may be in the case of 5 consecutive

satisfactory microbiological findings of the reduced frequency of checks

microbiological parameters and TOC on once a month.



6. Apply, if you are in the pool, installed a device that creates

aerosols, such as bubble hot tubs, waterfalls, geysers, fountains,

neck showers and the like. In the case of continuous measurement of disinfectant
preparation of pH and redox-potential and pH adjustment and automatic control

dosage of disinfectant can be in the case of 5 consecutive

following satisfactory microbiological findings of reduced frequency

checks on once a month.



7. the optional, but recommended a pointer, which is the appropriate instrument for

the current monitoring of the load the pool water organic compounds (TOC) of the

operators, in particular in the case of continuous measurements.

Recommended value A254 (1 cm) of pool water is equal to the value of 0.02

the value of the filling of water.



Annex 10



Hygiene requirements for pools for infants and toddlers, their operation,

replenishment, water quality and water quality control



The requirements of the swimming pool and its operation, replacement, and water quality and the environment

According to the age of the child



1)



Child's age 3-6 months:



Environment: Plastic tubs and swimming pools or other containers of suitable

the material is easy to clean and dezinfikovatelným the surface, which

are used only for the purpose of bathing infants. In the course of teaching

the clock must be located in an area separated from other traffic

the swimming pool.



Water: Filling (napouštěná) the water must be of drinking water quality ^ 12).



The water temperature of 30 to 36 ° c.



Air temperature: 28-30 ° c.



Operation: Each day before the first with must be a bathtub, swimming pools or

other containers are properly cleaned, disinfected and rinsed with. In the bath,

taking just one child, led by an escort or an instructor outside of the tub

(the accompaniment does not enter into the bathtub). The water is exchanged after each child. After

3-5 water exchange is necessary to perform surface disinfecting bathtub with the fact that

After the bath will be rinsed out properly to remove

residues of the used disinfectant agents.



2)



Age child 6-12 months:



Environment: For bathing infants aged 6 to 12 months is necessary to use the

bath tubs, swimming pools or other containers (see age category 3-6 months), or

any of the following types of pools:



Type 1: portable swimming pools with recirculation



Type 2: steadily built swimming pools with recirculation, intended only for children

the conditions listed below

.



Type 1

:



Portable swimming pools with recirculation, treatment and disinfection of water, only

children (crèches, kindergartens, schools and other children's establishments) or

operated exclusively for the purpose of bathing and swimming for infants and toddlers, and

operated in accordance with the principles laid down in this Decree. It is recognised

the presence of několikačlenné groups of children with their accompaniment in the pool.

Minimum water surface area on one koupajícího is 0.8 m2.

At least once a week must be properly cleaned, drained swimming pool,

disinfected and rinsed.



Type 2

:



Steadily built swimming pools with recirculation and properly functioning treatment plant

water, including at least coagulation, filtration and disinfection with chlorine,

used only children (nursery, kindergartens, schools and other children's

devices) or operated solely for the purpose of bathing and swimming

infants and toddlers under the condition that the learning hours before operation

swimming infants and before with water will pool, poolside and

used facilities cleansed, disinfected and rinsed carefully

clean water, that water will be newly filled with or sufficient time (e.g..

overnight) before operation, recirculated, so that at least one

went through the treatment plant, and water quality will meet repeatedly laid down

the requirements. After the end of a training day will be the swimming pool, the pool area and

used facilities cleansed, disinfected and rinsed carefully

clean water.



Solid children's pool without recirculation can be used only under the conditions that the

before each production day will be disinfected and newly infused with filling

water, and during the operation will be continuously disinfected with chlorine dotékat

drinking water and overflow drain out the excess water in a minimum amount of 1

litre/min on one koupajícího, so as to ensure sufficient

the mixing of the water according to § 17 paragraph. 2.



The presence of několikačlenné groups of children with an escort in

the swimming pool. Minimum water surface area on one koupajícího is 0.8

the M2.



Water: the water quality before operation, and at the time of the operation must

correspond to at least the requirements set out in annex 8.



Water temperature: 28 ° c up to 32.



Air temperature: 28 ° c to 30 ° c.



3)



The age of a child over 12 months (up to 3 years):



Environment: the same equipment as for the age 6-12 months.

If they are used other than the pools referred to in paragraph 1 and 2 shall

the commencement of the operation of the water in the pool is sufficiently long and recirculate

Browse finishing without a swimming pool used at the time. The entire volume of water

the pool must at least once before operation to go through properly

functioning of water recirculated in the treatment plant, involving at least coagulation,

filtration and disinfection with chlorine.



The swimming pool must be accessible with a depth of water max. 130 cm. If

its depth is greater than 130 cm, then swimming must be limited to the part of the

pool after this depth and the depth of the boundary must be at the surface

marked by floats. After a period of course swimming and swimming toddlers cannot be in

the pool operated for this purpose to engage in other activities with

This rate are not directly related.



Water: the water quality conforms to the requirements set out in annex 8.



Water temperature: 28 ° c up to 32.



Air temperature: 28-30 ° c.



Operation: the presence of the escort with the kids in water is possible. The maximum number of

persons is determined by the capacity of the pool, with the water level on the minimum area

one koupajícího is 1 m2.



Check the quality of the water in the swimming pool



1) before the beginning of the operation, the operator shall verify the temperature of the water and the air,

to meet the needs of under age children.



2) the operator of a swimming pool periodically checks the quality of the water in the pool.

The frequency and extent of checks depends on the type of pool and the method of operation.



3) for portable van and swimming pools, which are emptied, cleaned,

and rinsed after each's infants or infants group

checks the temperature and the transparency of the water after each soaking. Once a

Moon performs microbiological water analysis (in the range of indicators

Escherichia coli, the number of colonies in the 36 ° c and Pseudomonas aeruginosa)

as proof of the effectiveness of the cleaning of the tub. To the implementation can only be used

drinking water or warm water, produced from drinking water.



4) for other pools with recirculation or interim variation of water

they are not emptied after each group of infants, the same requirements apply

on water quality and its control, what is true for the bath the pools according to the

Annex No. 8, 9 and 11 (with the exception of free chlorine, which indicators should be

range 0.2-0.4 mg/l).



5) water samples for inspection shall be taken during the operation, the first 1

an hour after its launch. If the teaching hours less than an hour,

Removes the sample prior to its termination.



Annex 11



Determination of the intensity of the recirculation water



1.



Swimming pools



----------------------------- ------------------------------------------------

The average depth of the swimming pool water exchange Time (delay) in hours

v metrech ------------------------------------------------

in the indoor pool in the roofless swimming pool

----------------------------- ------------------------------------------------

0,5 2,0 2,0

1,0 3,0 3,5

2,0 5,0 8,0

3,0 6,0 8,0

3,5 6,5 8,0

4,0 7,0 8,0

----------------------------- ------------------------------------------------



The values in the table are referred to as guideline values.



Needed in the quantity of water in m3/h is intended for guidance

the share of the volume of the swimming pool and the theoretical time delay of water. Specifies the

by calculation, in which is included the attendance, the purpose of the pool and the required

water quality, technological and operational parameters of the recirculating water treatment

water. If it is not the intensity of the recirculation T clarified demonstrable and

a controlled calculation, then apply as those that limit values

are given in the table above. Residence time or the time of the exchange of water

(the intensity of the recirculation) T relate to the nominal performance of the treatment plant, including

all petrol units and their reserves. The total rated power

recirculating water treatment plants is given by the sum of the individual shares all

pools connected in a parallel arrangement of the recirculating water treatment plant.

In the amount of water needed for the pool in m3/h

as the proportion of the volume of water of the swimming pool and the time delay (time of the exchange of) water

T. for swimming pools with water attractions, it is necessary to increase the intensity of the

with regard to the recirculation losses of active chlorine in the pool water of his

by leaping into the air.



2.



Bath pools



The intensity of the recirculation is set according to current needs. The Exchange or

filtration of the entire volume of the water in the pools with a capacity of up to 5 m3 including the

be carried out at least once every 15 minutes, for pools with a volume of 5-10 m3

at least every 45 minutes; for pools with a volume of water of more than 10 m3,

the intensity calculation of, or Exchange provides filtering of the entire volume

the water, however, must take place at least once every 2 hours.



The intensity calculation of recirculation water in the pool is the designer in dokládán

the processed project documentation, which is part of the.



Annex 12
Climatic requirements, lighting and indoor air swimming pool hall

the indoor swimming pool and its adjacent area



------------------------- ---------------------------------- --------------------------------------------------

Environmental factor pool Hall adjacent spaces for the user lobby

(changing rooms, showers, WC, corridor, etc.)

------------------------- ---------------------------------- --------------------------------------------------

Illumination min 200 lux for vacation 200 lux 100 Lux

swimming, min. 300 lux for

swimming training

------------------------- ---------------------------------- --------------------------------------------------

The air temperature of 1-3 ° c higher than the temperature of the shower 24-30 ° c min 17 ° c

the water in a swimming pool changing rooms and room for stay of persons 20-28 ° c

Max. 34 ° c pobytovéprostory 22-26 ° c

vstupníprostory 20-22 ° c

------------------------- ---------------------------------- --------------------------------------------------

Relative air humidity max. 65% showers max. 85%

ostatníprostory max. 50% of the

------------------------- ---------------------------------- --------------------------------------------------

The intensity of the exchange of air at least twice per hour sprchymin. 8 x per hour, 1 x per hour min.

dressing room 5-6 x per hour

other spaces to suit the exposure limit

the values of the relative humidity of the air

------------------------- ---------------------------------- --------------------------------------------------

Trichloramin 0.5 mg/m3 (Note 1)--



------------------------- ---------------------------------- --------------------------------------------------



Note 1: as the recommended value, but the operator should

strive to achieve the lowest possible value. Sampling shall be carried out 20 cm

above the surface of the water in the pool; If it is not technically possible, and in the height

150 cm above water level. The frequency of monitoring the pool operator shall elect

as needed, based on local conditions (the results of previous

determination, the measured values of the bound chlorine, seasons, etc.).



Annex 13



Microclimatic conditions and lighting the sauna



------------------------------------------ ----------------------------- -----------------------------------------------

Instead of Height. Max. temperature Max. rel. Min. air exchange. Emergency

air temperature humidity floor lighting

(m) the air (° c) air lighting

(° C) (%) (lx)

------------------------------------------ ----------------------------- -----------------------------------------------

Corridor 1.6 18-50, twice per hour, 100 +

------------------------------------------ ----------------------------- -----------------------------------------------

Cloakroom 1.6 22-50, twice per hour, 200 +

------------------------------------------ ----------------------------- -----------------------------------------------

Room *-50 +

1.5--80 15

2,0 - 110 - -

------------------------------------------ ----------------------------- -----------------------------------------------

The inside shower-70 75 + twice per hour

------------------------------------------ ----------------------------- -----------------------------------------------

External shower-----75-

------------------------------------------ ----------------------------- -----------------------------------------------

Rest room 1.6 23-50 twice per hour + 75

------------------------------------------ ----------------------------- -----------------------------------------------

1.6-lavatory 20-50 m3 to 1 100-

klosetovou Bowl

------------------------------------------ ----------------------------- -----------------------------------------------



For other types of saunas, than it is stated in section 34 can be according to the recommendations

manufacturer for sauna technology admit other temperatures and other

the relative humidity of the air.



Annex 14



Table 1:



Hygienic limits for selected indicators of microbiological and

pollution of the sand in the parasitology hookworm is on outdoor playing

surfaces.



Table No. 1



---------------------------------------------------------------------------------------------

Indicator number of Units tested Limit Detritus

the micro-sample finding samples each (the number of)

(g) control (CFU in 1gramu)

---------------------------------------------------------------------------------------------

Geohelminti

live stage 5 1 15 < ***

---------------------------------------------------------------------------------------------

Termotolerantní

coliform

bacteria 10 CFU in 1 5 1 < 103

Gram 4 < 50



---------------------------------------------------------------------------------------------

Enterococci 10 CFU in 1 5 1 < 103

Gram 4 < 50

---------------------------------------------------------------------------------------------



* CFU-colony forming unit

** Taken from 5 samples must comply with at least the specified number of prescribed limits.

The negative finding in each sample.



Table 2:



Hygienic limits of selected chemical elements

------------ ---------------------------------------------------

The limit values of the selected elements in the hookworm is

Element of children's playgrounds in mg.kg-1 of dry matter



The total content

------------ ---------------------------------------------------

As 10.0

Be 1,5

Cd 0,5

What 50.0

CR 100.0

CU 100.0

Hg 0,3

Mo 0,8

Her 60.0

PB 60.0

V 80,0

Zn 150.0

------------ ---------------------------------------------------



Selected provisions of the novel



Article. (II) Decree No. 97/2014 Sb.



The transitional provisions of the



The provisions of § 18 paragraph. 1 sentence the second decree No. 238/2011 Coll.

determination of the sanitary requirements for the swimming pool, the sauna and the health

the levels of sand in outdoor areas, hookworm is a slot in the text of this

the Decree shall apply to swimming pools design after the date of entry into force of

This Decree and pools restored after the date of entry into force of this

the Decree.



1) European Parliament and Council Directive 2006/7/EC of 15 December 1997. February

2006 on the management of bathing water quality and repealing Directive 76/160/EEC.



2) Law No. 164/2001 Coll., on the natural medicinal resources, resources

natural mineral water, natural healing baths and Spa

places and amending certain related laws (the Spa Act),

as amended.



3) for example, Decree No. 268/2009 Coll., on general technical

requirements for the construction, Decree No. 398/2009 Coll., on general technical

barrier-free use of the assurance requirements of buildings, the Decree of the hl.

m. Prahy No 26/1999 Coll. hl. m. Prahy, on general technical

requirements for the construction in the capital, Prague, as subsequently amended

regulations.



4) Law No. 274/2001 Coll., on the public water supply and sewerage Act

the need for, and on the amendment to certain acts, as amended.



5) Act No. 254/2001 Coll. on waters and on amendments to certain acts (the water

Act), as amended.



7) Decree No 155/2011 Coll., about the profiles of the surface waters used to

swimming.



8) Law No 120/2002 Coll., on conditions for the placing of biocidal products and

active substances on the market and amending certain related laws, in

as amended.



9) EN 15288-2 swimming pools-part 2: safety requirements for

the operation of swimming pools.



11) ČSN EN 12193 light and lighting-Lighting of sports facilities. ČSN EN

12646-1 light and lighting-lighting of working areas-part 1:

The internal working spaces.



12) Decree No. 252/2004 Coll., laying down the health requirements for

drinking and hot water, and the frequency and extent of monitoring drinking water, in the text of the

Decree No. 187/2005 Coll. and Decree No. 293/2006 Sb.



13) Decree No. 409/2005 Coll. on hygienic requirements for products

coming into direct contact with water and water treatment, as amended by

Decree No. 352/2013 Sb.