Administrative Measures On Earthquake Resistance Protection Of Construction Engineering Requirements, Liaoning Province

Original Language Title: 辽宁省建设工程抗震设防要求管理办法

Subscribe to a Global-Regulation Premium Membership Today!

Key Benefits:

Subscribe Now for only USD$20 per month, or Get a Day Pass for only USD$4.99.
(February 7, 2004 Liaoning Province Government 27th Times Executive Conference considered through February 27, 2004 Liaoning Province Government makes 165th, announced since April 1, 2004 up purposes) first article to strengthening on construction engineering seismic fortification requirements of management, defense and reduce earthquake disaster, protection people life and property security, according to People's Republic of China earthquake mitigation method and State earthquake security evaluation Management Ordinance, about legal, and regulations, combined I province actual, developed this approach.
    Province article requirements of earthquake resistance protection of construction projects management in the administrative areas, these measures shall apply.
    Article III administrative areas of our province of mainland shock peak acceleration 0.05g (basic seismic intensity of 6 degrees) above regional projects (including new construction, expansion, renovation projects, the same below), you must follow these rules determine requirement for earthquake, implementation of fortification.
    Requirements for seismic resistance in these measures refers to construction projects must be achieved to resist earthquake damage criteria and specifications.
    Fourth of provinces, cities and counties (including County-level cities and districts, the same below) Department or agency responsible for seismic work in accordance with the functions and powers, is responsible for supervision and administration requirements for seismic work within their respective administrative areas.
    Development plans, urban planning and construction Administrative Department in accordance with their respective responsibilities, responsible for construction project management of requirement for earthquake-related work. Fifth article determine construction engineering seismic fortification requirements, should followed following provides: (a) major construction engineering and may occurred serious secondary disaster of construction engineering, according to earthquake security evaluation results determine; (ii) preceding paragraph provides yiwai of construction engineering, according to China earthquake moving parameter Division figure marked of parameter determine; but is located in to vibration parameter Division figure in the to vibration peak acceleration partition line sides the 4-kilometer range within of construction engineering, by units select following way determine: 1.
    Review implementation of ground motion parameters, determined according to the seismic parameters review; 2. the review shall not be ground motion parameters according to seismic zoning boundaries in the high value of the parameter the parameters on one side and (iii) has completed seismic micro zoning or regionalization of urban earthquake work approved by the State, determined in accordance with the results.
    The preceding paragraph (a) called for major construction projects and serious secondary disasters of construction project's scope, by the provincial development planning Administrative Department for seismic work, in conjunction with the province of sector relevant administrative departments, such as the development and construction, reported to the provincial government for approval.
    Sixth above the county level are responsible for seismic work of departments or agencies should be submitted on the following regional ground motion parameters review the programme of work, the level of Government for approval: (a) the peak acceleration in the peak ground motion acceleration zoning map zoning boundaries on both sides of the 4-kilometer range; (b) the poor areas and degree of earthquake research and information level of detail earthquake risk area.
    Seventh article County above is responsible for management earthquake work of sector or institutions according to need and may, on following regional proposed carried out earthquake small Division work programme, reported this level Government approved Hou implementation: (a) is located in earthquake focus monitored defense district within of city and center town; (ii) is located in to vibration parameter 0.15G above area of cities; (three) is located in complex engineering geological conditions regional within of large factories enterprise, and long lifeline engineering and new zone.
    Eighth in earthquake safety evaluation, review and seismic microzonation of seismic dynamic parameters, you must delegate unit eligible for qualification, and commissioned by the units responsible for the technical report submitted to the provincial Department responsible for seismic work, in accordance with administrative rights after the review and determine requirement for earthquake, inform the Commission in writing units and construction for seismic work, seat of the city's departments.
    Nineth for major construction projects and construction of a possible serious secondary disasters, its feasibility study report shall be attached with the seismic safety evaluation report above for seismic work, and province departments to determine requirement for earthquake is not attached with the seismic safety evaluation report above for seismic work, and province departments to determine requirement for earthquake, project examination and approval Department shall not be approved feasibility study report.
    In ground motion parameter zonation map zoning boundaries on both sides of the 4-kilometer within the scope of construction works, project feasibility study report shall be attached in accordance with the first paragraph of the article fifth (b) determine requirement for earthquake.
    Article tenth of fortification must be implemented construction projects, design units shall in accordance with this approach to determine requirement for earthquake seismic design codes and national requirements, seismic design, supervisor of construction engineering, construction, supervision should be carried out in accordance with seismic design.
    11th above the county level are responsible for seismic work of departments or agencies shall strengthen the supervision and inspection requirements for seismic compliance. May occur and serious secondary disasters of major construction projects construction as well as parameters of ground motion review of the construction project when it is completed, the construction unit shall invite construction for seismic work, where departments or agencies acceptance requirements for seismic compliance.
    Experience requirements for seismic without acceptance or fail to pass, construction projects may not be delivered.
    12th article violation this approach fifth article first paragraph subsection (a) items provides, on major construction engineering and may occurred serious secondary disaster of construction engineering not for earthquake security evaluation, or not used according to earthquake security evaluation results determine of seismic fortification requirements of, by County above is responsible for management earthquake work of sector or institutions according to People's Republic of China earthquake mitigation method of about provides punishment; constitute crime of, law held criminal. 13th article violation this approach fifth article first paragraph subsection (ii) items provides, has following case one of of, by County above is responsible for management earthquake work of sector or institutions ordered deadline corrected; late not corrected of, at 10,000 yuan above 30,000 yuan following fine; constitute crime of, law held criminal: (a) not used China earthquake moving parameter Division figure marked of parameter determine seismic fortification requirements of; (ii) both not implemented to vibration parameter review,
    Not using one side of the ground motion parameters of zoning boundaries in high-value parameter to determine requirement for earthquake and (iii) introduction of ground motion parameters for review, not by reference to the review of seismic dynamic parameters to determine requirement for earthquake.
    14th article violates article tenth of these measures, not in accordance with this approach to determine requirement for earthquake seismic design and seismic design specification or not according to seismic design, supervision of construction, the construction Administration Department in accordance with the People's Republic of China earthquake disaster mitigation Act the relevant provisions constitutes a crime, criminal responsibility shall be investigated according to law.
    15th article violates this article 11th paragraph, without a construction for seismic work, where departments or agencies acceptance requirements for seismic experience or fail to pass, use of unauthorized building works, the relevant administrative departments under the State Council of the relevant provisions of the regulations on the management of construction engineering quality.
    16th impose administrative penalties, in accordance with the People's Republic of China administrative penalty provisions of that Act; penalties and fines, Liaoning province, in accordance with the penalty decisions from collection of penalty provisions of the detailed rules for the implementation of separation of implementation.
    17th article is responsible for management earthquake work of sector or institutions of staff has following behavior one of of, by its where units or superior competent sector give administrative sanctions; constitute crime of, law held criminal: (a) on seismic fortification requirements of used situation not for supervision check or not law acceptance, led construction engineering occurred serious earthquake consequences of; (ii) has other abuse, and engages in, and negligence behavior of.
                        18th article this way come into force on April 1, 2004.