Car enclosures must be:
(1) Enclosed on all sides, except at the entrance, to a height of at least 42 inches;
(2) Enclosed with a type of material that will reject a 1 1/2 inch diameter ball;
(3) Securely fastened to the car platform so that it cannot become loose or displaced due to ordinary service, application of the car safety, or car contact with a buffer.
(4) Built to withstand a 75 pound pressure, horizontally applied at any point on the wall, without causing a wall deflection that reduces running clearance below 3/4 inch or above 1 inch.