Cabinet of Ministers Regulations No. 383 in Riga, July 9, 2013 (pr. No 39 39 §) rules for buildings issued in accordance with energosertifikācij of the energy performance of buildings 7. the third paragraph of article 8 of the eighth, the fifth paragraph of article 9, the third paragraph of article 10 and article 11, third part i. General provisions 1 the questions determines: 1.1. building energosertifikācij; 1.2. the energy performance certificate of a building and the building of temporary registration of samples, the dissemination policy, building energy benchmarking system; 1.3. the classification system of the energy performance of buildings; 1.4. requirements for energy efficiency and the use of high-efficiency system requirements almost zero energy buildings; 1.5. test procedure and time limits for heating systems, boilers of which effective rated output of more than 20 kW, and air conditioning systems of an effective rated output of more than 12 kW.
II. Building procedure energosertifikācij 2. to make the building in operation energosertifikācij, an independent expert: 2.1 check the calculations required output data quality and determine the applicability of it; 2.2. measuring and evaluation of measurements; 2.3. calculation of the building energy efficiency indicators in accordance with the laws and regulations of the building energy efficiency calculation method; 2.4. building energy performance certificate is issued; 2.5. prepare recommendations for improving the energy performance of the building. 3. to make those buildings (new construction, compensated or renovējam buildings), energosertifikācij independent expert: 3.1 check calculation required output data quality and determine the applicability of it; 3.2. calculation of the building energy efficiency indicators in accordance with the laws and regulations of the building energy efficiency calculation method; 3.3. the energy efficiency of the building shall be issued a temporary certificate. 4. building energy efficiency evaluation of Subscriber ensure independent expert access to the building or its premises and access to the building's technical systems, as well as access to such documents and information about the building: 4.1 building project or inventory plan; 4.2. building technical systems projects or drawings; 4.3. building technical systems instructions; 4.4. building technical systems operation and maintenance logs or reports;
4.5. the actual use of the premises and the temperature in the premises; 4.6. the utility provider statements or invoices for actually listed the amount of energy consumed by a building, or the building's technical systems; 4.7. data on building commissioning; 4.8. data on the building's technical systems installation or replacement of buildings during the operation; 4.9 calculation of energy (if any); 4.10. previous inspection findings (if any); 4.11. other required information related to building energy audits and heating boiler or air conditioning system check smooth operation.
III. Building energy performance certificate 5. dissemination shall be building into existing buildings and their parts in accordance with the provisions of annex 1, but building a temporary dissemination of those buildings (new construction, compensated or renovējam buildings) and parts (new, compensated or renovējam building) in accordance with the provisions of annex 2. 6. dissemination of the building or building temporary dissemination is completed, subject to the following conditions: 1. this rule 6.1 of annex 1 or Annex 2, paragraph (1) shall indicate one of the following building types: 6.1.1. different types of viendzīvokļ building; 6.1.2. the apartment house; 6.1.3. Office building; 6.1.4. the building of educational institutions; 6.1.5. the outpatient or inpatient treatment institution building; 6.1.6. hotel and restaurant building; 6.1.7. sports building of institutions; 6.1.8. wholesale or retail buildings; 6.1.9. other types of building, in which the use of energy; 6.2. If the type of the building complies with this provision of the type referred to in paragraph 6.1.2., this rule paragraph 1 of annex 1 or Annex 2 in paragraph 1 specify the number of additional flats in the House; 6.3. This provision is paragraph 6 of annex 1 or Annex 2 paragraph 6 in the "last year of reconstruction/renovation" indicates the last year when reconstruction or renovation work in the affected building facade or influenced the building energy efficiency indicators; 6.4. This provision of the annex 7, paragraph 1 or 2 of annex 7, paragraph building energy efficiency class indicated in accordance with paragraph 14 of these regulations, subject to the following conditions: 6.4.1. new points of reference (A), (B), (C) and (E) class buildings; 6.4.2. compensated buildings indicate the reference values (A), (B), (D) and (E) class buildings; 6.4.3. commissioning existing buildings reference point (A), (D), (E) and (F) class buildings; 6.4.4. the E and F class building values indicate only building types for which they are established in accordance with these rules or other laws and regulations; 6.4.5. This provision is paragraph 6 of annex 1 in the "calculated area" and 7, 9, 10 and 11 of the relevant fields or paragraph 6 of annex 2 in the "calculated area" and 7, 10 and 11 of the relevant fields indicate values determined in accordance with the calculation of the energy performance of the building method. 7. dissemination of the building adds: 7.1 Overview of economically justified energy efficiency enhancing measures that implementation costs are cost effective future (planned) lifetime (annex 3); 7.2. heating boilers, heating systems and air conditioning inspection measures drawn up these regulations 19, 20 and 23 of the time limits referred to in paragraph; 7.3. the annex specifying the input value used in the calculation, you specify a data type and data source: 7.3.1. the names of the rooms or areas, area and temperature; 7.3.2. delimiting areas and design of heat loss coefficient; 7.3.3. the thermal bridge lengths and heat loss coefficient; 7.3.4. building technical systems used in the values used in the assessment; 7.3.5. the value adopted to meet building energy efficiency affecting factors; 7.3.6. the adjustment of the climatic conditions and the calculation of the coefficients used to refine; 7.3.7. energy efficiency assessment the confidence interval, if it is defined; 7.4. the annex with the estimates of the energy efficiency of the building measures improve the payback periods; 7.5. other documents that provide additional information on the assessment of the energy performance of the building, scoring conditions or conditions. 8. temporary building annex is added to the dissemination of the rules of 7.3.1, 7.3.2, 7.3.3, 7.3.4.. and the calculations referred to in paragraph 7.3.5. use the input values, and this rule 7.2. documents referred to when building a temporary dissemination shall be issued or compensated renovējam building.
IV. dissemination of procedures for registration of buildings 9. Independent expert building or temporary dissemination dissemination within five days after the issue of the dissemination of buildings recorded in the register. 10. dissemination of the register maintained by the building of the Ministry of economy. 11. building on the register includes data dissemination, which in accordance with these provisions included in the dissemination of the building, building a temporary dissemination and in the annexes to this document, as well as heating and air conditioning inspection. 12. for each of the dissemination of building document registered at the registry of the Ministry of the economy shall assign a registration number.
V. Building Energy benchmarking assessment and classification system and requirements of nearly zero energy buildings

13. building energy benchmarking system consists of building regulations energy efficiency indicators, energy efficiency and building a statistically determined the type of average energy efficiency of heating consumption comparison of indicators that represent the comparative evaluation scale in accordance with the provisions of annex 4. 14. Comparative evaluation scale, the following buildings: energy efficiency class 14.1. residential buildings: 14.1.1. Class-meet this provision in paragraph 17 above requirements almost zero energy buildings; 14.1.2. Class B – energy efficiency indicator heating not exceeding 40 kWh per square meter per year; 14.1.3. C class – energy efficiency indicator for heating up to 50 kWh per square meter per year; 14.1.4. Class D – energy efficiency indicator heating does not exceed 60 kWh per square meter per year; 14.1.5. E class-representing a building type for average consumption; 14.1.6. F class-match regulations Uptown management defined permissible energy consumption level; 14.2. non-residential buildings: 14.2.1 A class-meet this provision in paragraph 17 above requirements almost zero energy buildings; 14.2.2. Class B – low energy consumption building which complies with the class A and C, and the average value of this rule and section 17.3.17.4. requirements of nearly zero energy buildings; 14.2.3. class C – meet the regulations in the field of construction requirements for new buildings; 14.2.4. Class D – comply with the laws and regulations in the field of construction requirements compensated buildings; 14.2.5. E class-representing a building type for average consumption. 15. building energy efficiency class indicator corresponds to the value, in accordance with the calculation of the energy performance of the building method of building energy consumption for heating. The value referred to in this paragraph shall be expressed in whole numbers to calculate the area of kilowatt-hours per square metre per year. 16. the Ministry of the economy once a year until March 1 to provide statistically determine the average energy efficiency of heating consumption figures published by the Ministry of economy website on the internet for at least the following types of buildings: 16.1 multi-family housing; 16.2. Office buildings; 16.3. education buildings. 17. The building is classified as a near-zero energy building, if it meets all the following requirements: 17.1. energy consumption for heating purposes shall be drawn up not more than 30 kWh per square meter per year, whilst ensuring compliance with the regulations of the indoor climate requirements, hygiene and construction work; 17.2. the total primary energy consumption for heating, hot water supply, mechanical ventilation, cooling, lighting make up no more than 95 kWh per square meter per year; 17.3. the building uses high-efficiency systems: 17.3.1. not less than 75% provide ventilation heat loss recovery heating period; 17.3.2. at least in part, to the use of renewable energy; 17.4. the building is installed below the efficiency of fossil fuel heating equipment.
Vi. the heating system and air conditioning inspection 18. The heating system shall be carried out at the buildings heating system available parts (such as the heat generator, control system and the circulation pump or pumps), if this system boilers effective rated output for space heating purposes is more than 20 kW. 19. the heating system checks: 19.1. If the heating system boiler effective rated output of more than 100 kW: 19.1.1. at least once every four years-heating systems with gas boilers; 19.1.2. at least once every two years – in other cases; 19.2. If the heating system boiler effective rated output of more than 20 kW but not exceeding 100 kW: 19.2.1. at least every five years – heating systems with gas boilers; 19.2.2. at least once every four years – in other cases. 20. If the heating system equipped with command and control devices that support electronic system monitoring and control, this rule 19.1 and 19.2. checks referred to time limits may be extended by two years. 21. The heating system check includes the evaluation of the effectiveness of the boiler and boiler size compared to the heat demand of the building. The size of the boiler rating must not be repeated, if the heating system has not been modified in relation to the building's heating requirements. 22. The boiler shall be inspected in accordance with standard EN EN 15378:2009 L "building heating system. Boilers and heating system inspection "(hereinafter referred to as the standard LVS EN 15378:2009). On heating system of inspection shall be drawn up by an independent expert: 22.1. heating system boiler inspection in accordance with standard EN EN 15378:2009 Annex D; 22.2. the heating system inspection in accordance with standard EN EN 15378:2009 Annex K. 23. Air conditioning system check out air conditioning parts available if the air conditioning system of the effective rated output of more than 12 kW. 24. Air conditioning system check: 24.1. at least every six years – if the air conditioning system equipped with command and control devices that support electronic system monitoring and control; 24.2. at least once every four years – in other cases. 25. Air conditioning system test include air conditioning systems efficiency and air conditioning systems compared to the size of the cooling demand of the building. The size of the assessment should not be made if the air conditioning system has not been modified in relation to the building's cooling needs. 26. check the air conditioning system in accordance with standard EN EN 15240:2009 L "building ventilation. Energy performance of buildings. Air conditioning inspection guidelines "(hereinafter referred to as the standard LVS EN 15240:2009). For air conditioning system of an independent expert examination shall be drawn up in accordance with the provisions of standard EN 2009 EN: 15240 G. 27. the heating system or air conditioning system checks the Subscriber ensure an independent expert with the system documentation (project or survey scheme), the previous legislation, the test operation of the records or reports, as well as provide access to the test system and its components, and the ability to uzmērījum. 28. the heating system boiler Inspection Act, inspection of heating systems and air conditioning inspection legislation by an independent expert is recorded in the register of the dissemination of buildings in accordance with the provisions of paragraph 11.
VII. Closing questions 29.6.4. This provision referred to the requirements for class B, C and D the identification of non-residential buildings and the E class specifying all types of buildings shall apply from 1 January 2014. 2014 1 January buildings referred to in this paragraph of this provision in paragraph 7 of annex 1 and annex 2, paragraph 7, in the "building class" the class is not specified. 30. This provision, paragraph 9 and 28 shall enter into force on January 1, 2014. 31. the dissemination and temporary buildings, as well as the dissemination of heating system and air conditioning inspection provisions, issued to 31 December 2013, the independent expert is recorded in the register of the dissemination of buildings up to 30 June 2014.
Informative reference to European Union Directive provisions included in the law arising from the European Parliament and of the Council of 19 May 2010 the 2010/31/EU directive on the energy performance of buildings. Prime Minister-Defence Minister Artis Pabriks economic Minister, Interior Minister Richard Kozlovsk a annex 1 Cabinet 9 July 2013 the Regulation No 383 economic Minister, the Interior Minister Richard Kozlovsk a annex 2 Cabinet 2013 9. Regulation No. 383 of July the Minister of economy, Minister of Home Affairs in place of Richard Kozlovsk of annex 3 of the Cabinet of Ministers of 9 July 2013 the Regulation No 383 overview of economically justified energy efficiency retrofit measures that implementation costs are cost effective future (planned) lifetime 1. Building type [in accordance with Cabinet of Ministers July 9, 2013 No. 383 of the provisions of the "rules for the building of the energosertifikācij" section 6.1] 2. The building's address [Street, building, village, County or city areas, city, municipality, County, postal code] 3. Part of a building [specify if refers to the part of the building] 4. Building or part of a cadastral designation [XXXX XXX XXXX XXX XXX]

5. recommendations for improving the energy performance of the building no PO box The measure, its description and target pointer, indicating the units delivered energy savings (from the existing building energy efficiency calculated estimate) implementation costs of the measure MWh per year kWh/m2 year Ls 5.1. Proposal of building external structure. delimiting. .. .. .. .. .. 5.2. the proposal of building technical systems.. .. .. .. .. .. 5.3. other buildings energy-efficiency measures in the proposal. .. .. .. .. .. ..
Note the. * Include recommendations that are technically possible for the building.

6. building energy efficiency indicators and comparison of the improvement recommendation of the variants (indicate the relevant section of this report proposed measures 5. index numbers) version 1 version 2 indicators measure the measured figures without correction rated indicators indicators to be achieved by the implementation of the proposal 6.1. building construction specific limiting heat loss coefficient of HT/W/(m2K) Aapr 6.2. Buildings ventilation heat loss coefficient specific HVE/Aapr 6.3. air exchange rate m3/(h × m2) 6.4. required energy evaluation kWh/m2 per year: t.sk. 6.4.1 6.4.2. for heating hot water system for ventilation. 6.4.3.6.4.4 6.4.5. illumination cooling 6.4.6. in addition to the reduction in Heat gain 6.5% building: kWh/m2 per year (heating period) 6.5.1 6.5.2 6.5.3 inland. the use of the solar gains. factor (heating period) 6.6 From renewable energy produced in the building energy kWh/m2 year 6.7. Primary energy assessment reduction% 6.8. Carbon dioxide (CO2) emissions rating year reduction kg CO2, 7. building energy efficiency recommendations published by an independent expert [name] register number [the independent expert's registration number in the register of independent experts] company [name, registration number and address, if the independent expert representing the firm] date ** signature ** note. ** document properties "date" and "signature" does not fill in, if an electronic document is drawn up according to the law on electronic document design.