Advanced Search

On Occupational Safety And Health In Mining Underground

Original Language Title: o bezpečnosti a ochraně zdraví při práci v hornictví v podzemí

Subscribe to a Global-Regulation Premium Membership Today!

Key Benefits:

Subscribe Now for only USD$40 per month.
22/1989 Coll.
DECREE


Czech Mining Office

Dated December 29, 1988

On occupational safety and health and safety at
mining activities and the conquest of unrestricted minerals underground

Change: 477/1991 Coll.

Change: 340/1992 Coll.

Change: 3/1994 Coll.

Change: 54/1996 Coll.

Change: 109/1998 Coll.

Change: 434/2000 Coll.

Change: 330/2002 Coll.

Change: 330/2002 Coll. (Part)

Change: 141/2004 Coll.

Change: 298/2005 Coll.

Change: 282/2007 Coll.

Change: 361/2009 Coll.

Change: 35/2010 Coll.

Change: 176/2011 Coll.

Czech Mining Office determined under § 5 para. 3 and § 6 para. 6 point. a)
Czech National Council Act no. 61/1988 Coll., on mining activities,
explosives and the State Mining Authority:
PART ONE



General Provisions Part first

Introductory provisions


§ 1
Heading left


Decree determined in accordance with European Community law ^ 1b)
requirements for ensuring occupational safety and health and safety
(hereinafter the "Occupational Safety and Traffic") at
mining activities ^ 1 ) underground and during the extraction of unreserved minerals-1a)
underground, including buildings and equipment on the surface that are related to these activities
. This decree was notified in accordance with Directive
European Parliament and Council Directive 98/34 / EC of 22 June 1998 on the procedure
provision of information in the field of technical standards and regulations and
regulations on information society services, as amended by Directive 98/48 EC.

§ 2


Definitions
(1) For the purposes of this Order shall be deemed

A) mobile (movable) machine such a machine, which in its working
activity varies from place to place,

B) long proof course beyond the loading surface of the vehicle in the longitudinal direction
so as to connect the vehicle to another vehicle should be used
auxiliary coupling device (rod, chain, etc.)

C) a mine operating unit, which usually forms in terms of ventilation
separate technical unit, regardless of how it is after the
organization called,

D) mine work underground space created by mining activities;
for mining work is regarded as ventilation, drainage, excavation and rescue borehole and other
wells, which performs the function of the mine. For mine work is not
search and exploration well,

E) mine fires unwanted and uncontrolled combustion; for mine fire is also considered
process of spontaneous combustion, from a stage when his
fumes are liable to jeopardize the health or lives of people or when the temperature
flammable materials could cause an explosion

F) label or demonstrate ban, warning, instruction or information expressed
sound, light, mark, sign or warning sign
according to its position or color

G) protective equipment or other technical devices to prevent serious injuries,
operational accidents or failures of technical equipment;
for the protective device is regarded as locking devices, mining machinery,

H) safe distance from the source of danger
distance between the device and the source of endangering the life or health workers (rotating,
moving or hot parts of machines, parts of electrical equipment under voltage
etc.) | ||
Ch) open fire deliberate and controlled burning; for the open fire is also considered as such
evolution of heat or sparks, which is
consequence of intentional physical or chemical processes or
marches and could cause a fire or explosion

I) underground work underground space created by mining activities carried out
way

J) longwall coalface a wall; Others work for mining of
are dobývky,

K) polostrmou seam, such seam or part thereof which has inclination
22-60 degrees from the horizontal plane

L) work associated with increased risk of such work which threatens
workers increased risk of accidents. They are the work provided by this decree
further work which is dictated by constant supervision, and work on that
so decides organization

M) office space dedicated personnel to perform work
including technical installations in this area, associated with the specified
work activities

N) establishment or otherwise enclosed confined space in which it is

Integrated mechanical or electrical equipment or which is intended to shut
mobile machinery,

O) security system operationally set of measurement and control elements
including necessary controls or other parts that
continuously or at set intervals
control the safe operation of the plant and ensure its shutdown under predetermined conditions
or in the state where it could cause damage to the device
due to exceeding or falling below specified values,

P) separate mine ventilation system department of workings, which are conducted
mining winds from the place where the mine is unused winds separated from the main or associated
vtažných wind currents up to the point where, after
use in workplace combine with other výdušnými winds or
outdoor atmosphere. In doing so, disregarding the use of wind for ventilation
early development and similar workings, mined from the United vtažného
or výdušného větrního current

Q) constant supervision constant monitoring of work and workers
state department in which a staff member designated organizations must move away from
workers and must not employ anything other than supervised

R) steep seam, such seam or part thereof which has the inclination greater than 60
degrees from the horizontal plane

S) duct excavated mine or underground work
circular cross section with diameter up to 2.2 meters or rectangular to square
3.75 m with a maximum depth of 40 meters; for the duct is also considered
digging wells,

T) equipment maintenance activities to maintain equipment
serviceable and safe condition. Equipment maintenance are also
prescribed inspections, tests, checks, inspections and repairs, as well as
assembly and disassembly of the machine to the extent necessary to carry out inspections
tests, checks, inspections and equipment repairs, || |
U) downhill guided air stream such an air stream that is conducted in a mine
whose general inclination of the horizontal downward
cm.m exceeds 2 -1

V) maintenance of workings process of creation or liquidation of mines.
Includes punching, reinforcement, maintenance, restoration, foundation,
securing and disposal of mining or underground mining works and
reserve deposits,

W) facility fire protection devices used to protect against fires and extinguishing fires
including the firehouse, warehouses and tools, fire
equipment, fire extinguishers and other means of fire protection
, smoke and fire doors and covers, preparatory
fire dams etc.

(2) For the purposes of this Decree also considers

A)

Burden of excessive weight
object whose mass is greater than 4000 kg

B)


Burden oversized object during the transport or handling can not be guaranteed spaces on
transport route specified in this Decree,

C)


Load bulky object requires for its safe loading and transport to transport
means in terms of ensuring stability Special sustaining him in the recovery position
,

D)


Special burden of proof excessive weight, the burden of oversized or bulky burden
,

E)

Transport by land transport path
proof transport platform or chassis with transport
propelled along conveying path positioned and anchored to invert mine
work secured against derailing or overturning vehicles
resources || |
F)


Shipping skid transport burden upon the rock basement after invert either transport platform
or without transport or on the platform after special leadership
positioned and anchored to invert the mine using a windlass or other machinery || | equipment

G)


Main grounding wire grounding wire from strojeného ground electrode to the mining and transformation substation
stations

H)


Cable hanger device for flexible cable clamping on the reinforcement of the walls or mine
works

I)


Sum of the heeling moment moments tangential component of gravity of the vehicle and tangential component of the load weight
relative to the tilting point

J)


Nonflammable electric circuit electrical circuit under normal operating condition does not create sparks

Nor thermal effect which would be capable of causing ignition of explosive gas atmosphere
,

K)

Current protection
overcurrent definite time (short circuit) two-stage overcurrent protection
time-dependent or inverse (overload) and
fault protection directional,

L)


Transport special transport and handling loads using special rail transport,
suspension or after terrestrial orbit and transportation of any load skid when
use the device with a pulling force greater than 45 kN,

M)


Stabilized coordinates position of the object at which the stabilizing moment is greater than the overturning moment
,

N)


Stabilizing torque sum of the moments of the normal component of gravity of the vehicle and moments
normal component of the load weight relative to the tilting point

O)


File system grounding connections and components that are necessary for the individual or
ground electrical equipment

P)

Power contactor above 1 kV
electrical devices with one rest position, which is not controlled by
hand and is able to turn, transmit and switch off the current under normal
conditions including operating overload

Q)

Breaker above 1 kV
electrical equipment designed for connecting and disconnecting electrical
circuits, lines or equipment, even under voltage at full load and
also in fault situations.

§ 3

Responsibility for compliance with the decree

Liability workers at individual levels for the implementation
obligations under this decree detailing the organization adjusts
organizational rules.
Part of the second


Buildings, workplaces and equipment

§ 4

Entry into buildings and workplaces

(1) Surface buildings and office equipment shall be enclosed or otherwise
secured against unauthorized entry.

(2) Usti workings to the surface must be secured against unauthorized entry
so not prevented workers from leaving the mine when
risk.

(3) holes, depressions, depressions and other places where there is a risk
fall of persons, must be covered fence or buried.

(4) The organization shall determine how security posts referred to in paragraphs 1 and 2
against unauthorized access and control their deadlines.

(5) The ban on the entry of unauthorized persons to the places referred to in paragraphs 1 and 2
must be indicated on the safety tables ^ 3) at all entrances,
approaches and ways to them.

(6) Entry into the workings marked bans (security
table, cross terephthalate, etc.) Or znepřístupněných is prohibited.
If necessary, may enter into them only upon a written statement in which
organization must identify measures to ensure the safety of workers entering
. Entry is allowed only after verification of the composition of mine air and the presence
employee designated for continuous measurement of the anticipated
pollutants.

(7) The objects and working persons are prohibited
which are under the influence of alcohol or narcotics; ^ 4)
carrying out random checks compliance with this prohibition and the extent and manner determined
racing pit or persons authorized by them.

(8) entering the workplace is allowed only personnel designated to work
control or supervision at the workplace; others only when accompanied by a designated official
.

(9) Anyone who enters the mine, mine must have a personal
light, self-rescue device, helmet and other necessary
personal protective equipment; 5) during boring pits, trenching
shafts up to 15 meters in works carried out
must have a self-rescue device only if it determines the organization and mining personal
light only if the work is not sufficiently illuminated by daylight.

(10) On the surface must have a helmet, anyone who enters the sites with
risk of falling objects.

§ 4a
Self-Rescuers


(1) coal mines can only be used by self-rescue devices
insulation type. On the other mines may be based on a favorable assessment and evaluation
risk-5a) instead sebezáchranného devices
type of insulation used self-rescue device filtering.

(2) At one mine can only use one type sebezáchranného
devices.

(3) self-rescue device is intended for use only issued for

Provided that the unit is clearly indicated diagram
manner of use.

(4) self-rescue device in a mine employee may defer
only work to a distance more than 5 meters apart.

(5) Organization demonstrably learn and practice them employees
sebezáchranného use the device, before his first assignment.
Practical exercises are repeated at least once a year.

(6) For practical training of staff to ensure the organization of such training
self-rescuers to allow practical exercises
workers within specified periods to perform. For practical exercises
possible to use discarded self-rescue devices.

§ 4b

Requirements objects

(1) Floors in areas where they go or places where there are people, not have
no irregularities, bumps, holes or dangerous slopes;
must be safe for walking and slip resistance.

(2) Floor area (base), height and volume of the work space
must be designed so that employees can do their job without
was influenced their safety, health or welfare of a good job.

(3) Space, the employee is available on site, must be
so great that the employee had in their activities
sufficient freedom of movement and could perform their tasks safely.

(4) Windows, skylights and ventilation devices which can be opened, closed
, rebuilt and secured, it must be designed so that
ensure safe handling. Must allow for safe cleaning.
In the open state must not pose a hazard to workers.

(5) Transparent or translucent walls, room dividers or
close to transport routes, doors and gates must be at eye
clearly marked and shall be made of safety materials or
reliably protected, that in the event of their breakage, to prevent
injury to workers.

(6) It is forbidden access to roofs made of materials that do not comply
load resistance, if there is no equipment with which to
appropriate action can be done safely.

(7) position, number and dimensions of doors and gates and materials for fabrication
must be chosen according to the characteristics and usage
spaces and workplaces.

(8) Doors must meet the following requirements:

A) pendulum (swing) doors and gates must be transparent or have
transparent window

B) sliding doors must be secured against ejection and falling out

C) doors and gates opening upwards must be
securable against unexpected fall back

D) doors to escape routes shall open outwards, they must be labeled
, the design must allow at any opening from the inside
without the use of aids and can not be locked

E) gates on the road with transport if their passage to pedestrians
is not safe, it must be equipped with other highly visible and more accessible
door for passage

F) doors and gates controlled by mechanical force must not endanger their movement
employees must be equipped with a clear, well
easily identifiable and accessible emergency stop devices as
except when a power failure automatically self open,
must allow manual opening

G) if the access at some point lose the chains or similar
device must be such chains or similar devices
clearly visible and marked with appropriate signs ban or warning.

(9) Auxiliary operating objects, such as workshop, office, warehouse or
rest must be placed in a safe area.

(10) are installed in the operating object
measuring and control apparatus which is fed gas, they must be
Blow-off pipe exhausted out of the object so that gas could not return, even | || diluted.

(11) Operational buildings must be labeled with the name of the object.

§ 5
Operating documentation


(1) Before commencing the work or activities for which it is determined
this decree must be made relevant operational documentation, and
technological process, workflow, traffic rules, operating regulations or
instructions for use ^ 77).

(2) Operating documentation must determine continuity or simultaneity

Work operations, conditions for the safe performance of work, endangered areas and
way of marking, equipment and instrumentation to ensure
work and operation safety and measures to ensure the workplace after a period
after which the it does not work.

(3) Operating documentation must comply with the regulatory requirements for
work safety and operational decisions on the authorization or approval
activities, installations or structures ^ 6)
technical conditions of the manufacturer or supplier equipment or buildings and the manufacturer's instructions for operation and maintenance
equipment.

(4) similar activities can be used in a type of operational documentation
adapted to local conditions.

(5) Operating documentation must be promptly when conditions change
adjusted.

(6) Employees must be aware before starting work with the operating
documentation to the extent that it relates to them.

(7) Operating documentation must be stored at a designated place
accessible for workers who are required to comply with.

(8) Operating documentation must be retained for at least a year from completion
work. If during this work has been massive, serious or fatal injury
must be operational documentation kept at least 5 years
from injury.

§ 6


Equipment
(1) When the activities covered by this decree can be operated and used only
workplaces, machinery, equipment, apparatus, equipment, facilities and materials
whose design, implementation and technical condition meets the regulations
to ensure occupational safety and health and safety
. Do use may be listed only products ^ 79)
which design, implementation and technical condition
meet the requirements for safe product. ^ 80)

(2) The use of machinery, equipment, apparatus, equipment and materials must be observed
instructions or technical conditions to the manufacturer instructions and conditions set
when their approval or authorization.

(3) Equipment, as well as other devices and utilities that serve
operation and its safety or protection of life and health of workers must be
still maintained and in perfect working order.
Device may be placed into operation or use only personnel designated to operate them.
Device can be used for acts for which they are intended; other acts only under the conditions specified
organizations.

(4) If the safety devices are damaged or urgent reasons
temporarily put out of action, it must be replaced as soon as possible or
brought to a proper state. Until then, must be safety and traffic
ensure appropriate security measures.

(5) The safety of workers at work at heights above 1.5 meters per
underground workplaces must deal with operational documentation.

(6) Near workings, stopes mined and mine workings, except manholes,
underground workings and underground structures must be placed
telecommunications equipment connected to the control room or other designated location.

(7) The organization is obliged to provide at least once a year inspection
steel and wooden structures and buildings if they are exposed
humidity or corrosive substances.

(8) In the inspection pursuant to paragraph 7 also determines whether
cover plates or gratings floor plates are secured against accidental displacement
, overturning a slanted position, and the cover plates or grids are treading
firmly. For platforms with external defects assessed visually and percussion.
For platforms that have a welded construction, with the visual inspection
detects also the state of welds their supporting parts to external flaws tapping.
When detecting external defects in welds are performed using their control
flaw detection (eg. Capillary) whether the welds and cracks.

(9) Cover sheets platforms must have a minimum thickness of 5 mm, if the project does not
higher value. The surface of the plates must be knurled or otherwise roughened
.

§ 7
Departments


(1) If the ordinance or special rules provide for a different period,
is obliged to inspect workplaces

A) shift engineer in a coal mine at least once in each half
shift in the other mines least once per shift, and on the surface
underground mine at least once a day; the non-working days may
organization of inspections of workplaces on the surface waive

B) technician immediately to the shift supervisor or engineer

Representative in the coal mine at least twice a week, in other
mines and underground mines on the surface at least once a week.

(2) The designated remote and scattered surface work with
simple operating conditions (manholes, Vrtba etc.) Is obliged to inspect workplaces


A) shift technician at least once a week,

B) senior technician immediately to the shift engineer or his representative
least once every two weeks,

C) foreman or group leader (the "foreman") in each inning,
which will be inspected by a) or b).

(3) The foreman designated to conduct inspections of workplaces under paragraph 2
point. c) must

A) have at least three years experience in implementing similar works

B) to attend training and pass an examination of the relevant regulations
to ensure the safety and operation to the extent required for the shift
technology

C) receive written authorization from the organization to supervise the definition
rights and obligations. This assignment must be stated in the operating
documentation for the workstation including a description of control activities
foreman.

(4) In the inspection department pursuant to paragraph 2. a) and b) must be checked
well as storage and security of explosives, explosives
evidence, and if it is to carry out blasting, also its preparation,
possibly execution.

(5) Shift technician, senior technician immediately to the shift
engineer and his representative (hereinafter referred to as "supervisory authorities") and other
technicians are required during inspections of workplaces to check compliance
relevant operational documentation, state security equipment and down
with an elevated risk of methane (hereinafter referred to as "gassy mine") and
concentration of methane in the mine air and fix defects have been corrected.
If not detected and rectified workers are obviously a
imminent danger, the supervisory authorities and other technicians
obliged to stop work and arrange exodus of workers to a safe place. About this
measures are required to immediately notify the dispatcher or inspection service
who notify inspectors of occupational safety and health authority
social control.

(6) The results of inspections and determined action must be recorded [
§ 23 paragraph. 1 point. G)].

(7) The supervisory authorities are required to carry a relevant part of the mine
maps showing all walls (§ 92 and 129) and rescue (§ 291
par. 8) tract.

§ 8

Preliminary examinations workings

(1) Safe condition of all underground sites where the
not work for the period specified in paragraphs 2, 3 and 4, including all approaches to them
must be checked before REPOPULATION workplace inspection.
Preliminary inspections must be carried out in places where they will reside
workers. Preliminary examinations carried out by a pair of workers
designed racing pit or an authorized officer. At the same time
must be determined for each pair workplace to control access to them and
times and places reporting inspection service.

(2) The gassy mines are preliminary examinations must be carried out unless
office was occupied two or more shifts. In workplaces
ovětrávaných průchodním air current, they can be expected that their
fumigation is excluded, inspections may be carried out only after 3 or more
vacant shifts. Preliminary inspections must be carried
less than three hours before the occupation of workplaces.

(3) separately ventilated mines, which is permitted
increased methane concentration according to § 83 paragraph. 5 and neproražená uphill from them
branching mines in plynujícím below must be pre-inspected after
unoccupied longer than 3 hours. The results of these inspections must
workers who are made, also noted on the table, face a
transferred to the appropriate place at the entrance to the mine in průchodním
air current. If these mines methane concentrations measured
continual analyzers placed under the rules governing
separate ventilation in gassy mines-80a) does not exceed
unoccupied for a mine of 0.8%, it is sufficient if these
mines after previously viewed unoccupied for more than two shifts.

(4) down without the occurrence of methane (hereinafter "neplynující mine") where

Idle for a specified period of time racing down may not be
preliminary inspections carried out sooner than 6 hours before the occupation of workplaces.

(5) Preliminary inspections must be established mainly
concentrations of carbon monoxide and carbon dioxide, in plynujícím below also
concentration of methane in the mine air and in the coal mine and coal dust disposal.
The gassy mines II. Class risk [§ 79 para. 4 point. a)] and
gassy mines with danger of rock bursts [§ 73 para. 1 point. b)]
workers must carry out preliminary examinations also equipped with portable
continual analyzers of methane or carbon dioxide
signaling.

(6) Results of preliminary examinations must be before the occupation of workplaces
reported to the dispatcher or inspection service, to work in accordance with § 7 paragraph
. 2 foreman and recorded.

§ 9

Evidence workers

(1) Accurate and uniform accounting personnel must be guided by their
start work until the end of the work shift.

(2) The staff responsible for keeping and supervisory authorities are obliged
later than one hour after the end of her shift to ensure that the
all workers left their workplaces or were assumed to
evidence of the following shift. Workers employed in the underground
are obliged to make sure that emerged from the mine.

(3) all persons who reside underground, must be guided by the dual
independent evidence. In the activities carried out by mining method in
which in most occupied inning underground stays of less than 10 people, just one
records.

(4) If someone is reported missing, they must be initiated immediately after the search.

§ 10


Inspection Service
(1) All work and other shifts must be ensured
inspection services, the organization and the tasks determined racing down.
This service may be entrusted to a qualified staff to manage the winding
accident. ^ 7)

(2) Non-coal mine neplynujícím with simple ratios, especially in
ventilation, the inspection service perform a function outside the mine for more
down if it is ensured

A) telecommunications link between the mine and Inspection Service,

B) informing the inspection services on the situation at the mine,

C) the withdrawal of workers from the underground and call for inspection services at the mine
case of an accident,

D) the urgent delivery of the inspection services at the mine in the event of an accident.

(3) If neplynujícího neuhelného underground mine does not work, it may
racing down waive collateral inspection services.

§ 11


Canceled A third part


Staff

§ 12

Introduction workers with safety regulations

(1) The organization is obliged to inform the workers who work designing,
control, supervise and implement, with this Decree and any special
regulations, to which the decree refers to other regulations to || | work safety and traffic-8) and the decisions of state
mining administration, at least to the extent required for the performance of their functions
. Deadlines repeated familiarization of staff with these regulations shall
racing down. The organization is obliged to allow workers to look into
these regulations and submit them to their request necessary explanations.

(2) The organization shall specify the activities for which it will issue rules ^ 8)
pass and the employees concerned.

(3) Newly recruited staff must be trained theoretically and practically
curriculum issued by racing down and tested. Theoretical training
workers who have to work underground and who are still underground
worked or have such work was interrupted for more than 2
years must be at least 24 teaching hours for workers on the surface
workplaces for at least 8 hours of instruction.

§ 13

Special Protection pupils while working underground

Underground can work pupils of secondary vocational school only
sites approved for that purpose organizations. This also applies to students
vocational schools and university students who are younger than 18 years
.

§ 14


Allocation of work
(1) An employee may be assigned to work (function) and work only when
if it has been previously assessed his medical fitness, ^ 9)
verified theoretical and practical knowledge, and if it was aware of the relevant

Regulations to ensure the safety and operation.

(2) Prior to the inclusion of workplace risk torrential rocks, coal and
gas, mining tremors or inrushes water and bahnin (zvodněných rocks) is
organization shall also instruct workers about these dangers on their
symptoms and how you should behave when they are discovered.

(3) An employee ignorant of local conditions must be at least on the first shift
brought down on workplace worker who is familiar with.

(4) The work associated with the increased risk may be carried out only by experienced personnel
. To carry out this work must be made operational
documentation and work must be done under constant supervision.

(5) Work to remove the obvious and immediate threat may be
performed only after the issue of their performance and determine
constant supervision.

(6) Whether it comes to labor under paragraph 4 or 5, decides
organization.

§ 15

Separate work performance

(1) An independent performance of work organization can entrust a worker
who has attained the age of 18 years, underwent designated internship, where he worked under the supervision of a designated
skilled worker, and passed the examination of relevant expertise
and regulations to ensure safety and
operation.

(2) outline job training, its duration and method of testing determines racing down by
kind of work if these requirements are not set rules to ensure the safety and
operation or special regulations.

(3) Training of a test may be waived organization workers who are
taught in the field in which they work, and
graduates of secondary vocational schools and universities corresponding direction.

§ 16

Cast workplaces

In the workplace, from which it is not possible by telephone or otherwise
call or report must be at least two workers.
At other sites may be one person; In this case, the organization
determine the manner and time of appeal or to report or shorter periods
inspections of workplaces supervisory authorities.

§ 17

Obligations workers

(1) Workers are required before work and during
verify the safe condition of the workplace. When the threat must stop work, report it
foreman and proceed according to § 18. In the work can continue once
threat passed.

(2) Except as provided in § 14 para. 5, § 45 para. 5, § 61, 63, 64, 65 and 71
workers should not enter into endangered areas, to remain in them, and
eliminate their possible designation.

(3) Workers are required to use the allocated
personal protective equipment while working to follow the operating documentation and regulations
to ensure the safety and operation and to select such working
procedures that are in accordance with principles of safe work.
Not, without a command to change anything on operational, safety, fire,
sanitary and other facilities. Use and can serve only those
machinery, equipment, tools and aids to them for their work
determined.

(4) Workers must not move away from your workplace without the consent
foreman or prematurely leave without the consent of the supervisory board, except for imperative reasons
(nausea, sudden illness, accident, etc.). Leaving the
urgent reasons are required as soon as possible an appropriate way to report
foreman and supervisory authority or dispatcher.

(5) Workers must follow the instructions under
safety signs, warning signals and warnings.
They are also obliged to follow the instructions patrols securing the safety circuit
(with blasting, etc.).

(6) In areas with increased fire risk on the surface
workers must use open fire and smoke. In exceptional cases
may use open fire only upon a written statement of the organization. ^ 10)

§ 18

Duties in danger

Anyone who notices a danger that could threaten the health or lives of people or
cause operational accident (crash) or failure
technical equipment, or the signs of danger, is obliged
if not eliminate danger alone, report it immediately to the Supervisory body
or dispatcher, or inspection service and by the possibility of raising
all persons who could be vulnerable to this danger.

§ 19

The foreman and his duties


(1) In group two or more workers must be determined by the foreman.

(2), the leader can be only one who has the necessary professional experience and passed
examination of professional knowledge and appropriate regulations to ensure
safety and operation. Provision of professional practice, the way the tests and their repetition periods
determined racing down. Foreman for conducting mining works
must have at least three years professional experience in conducting mining works.

(3) The foreman is obliged to ensure the security of their group status
safe workplace, compliance with operational documentation and fulfillment of orders
organization. When finding fault is obliged to ensure its
removal. If it can not do so and if there is clear and workers
immediate threats must stop work and lead their group on
safe place. About all defects and measures taken
is obliged to inform the competent supervisory authority or dispatcher, who
cases of work stoppages and notify the inspector of health and safety at work
organ of social control. The restoration work pays § 17 para. 1.

(4) The change of shift foreman is obliged to inform the incoming foreman
important facts or defects in the workplace. If he can not do so
, shall report to the Supervisory Authority before joining
alternating shifts.

§ 19a
Aggregation functions


In gassy mines can not be cumulated functions racing mine manager
ventilation and workers to control the installation, operation and maintenance of electrical equipment
or for more down, or with other functions; in mines with danger of rock bursts
^ 10a) shall not be granted also feature
geomechanics-10b) with other functions.
Part of the fourth

Emergencies


§ 20


Emergency Plan
(1) Organizations conducting mining activity is required to develop a plan
fighting serious operational accidents (accidents). 7 ^) ^ 11)

(2) If the organization to perform mining activities
required to prepare a plan for fighting serious operational accidents (accidents)
^ 12) is progressing appropriately under a special regulation, ^ 7) as
Czech Mining Office provides otherwise.

§ 21

Reporting serious accidents at work, serious events
serious operational accidents and dangerous states

(1) Racing mine ensure immediate reports of serious injuries
work, serious accidents, serious operational accidents and dangerous states
regional mining authorities.

(2) Called these serious accidents at work:

A) fatality,

B) a life-threatening injury, which is related incidents resulting in loss of body
(anatomical or functional), life-threatening injuries, including
industrial poisoning, injury and with such character of an accident that occurred
due to violation of safety regulations and suggests
serious threat to safety and health at work,

C) multiple injury accident when the same plot were injured
least three people, including at least one fatal accident suffered, or were
injured more than 10 people.

(3) Reported serious events, serious operational accidents and dangerous
states, and it

A) ignition and explosion of methane or coal dust

B) mining shock and such a concussive effect ^ 13), which saw work
injury

C) exogenous mine fire and surface fire within a radius of 60 meters from the intersection with pit
surface

D) the presence of carbon monoxide in concentrations higher than 0,013% if
results are not influenced by processes not having a connection with
samovzněcujícím process or threatening safety and
operation, such as blasting,

E) gassing the mine for more than 8 hours

F) a mine cave-in, which is expected RECOVERY for more than 24
hours

G) breakout waters and bahnin (zvodněných rocks)

K) cloudburst rock, coal or gases

L) forfeiture of people, machinery or equipment to the mine or other
underground space,

M) leakage of radioactive and other industrial wastes stored in
underground spaces, the loss of radioactive emitters or demonstrable
sealed source leak,

N) the search for missing persons,

O) accident during the transport of persons on the conveyor belt

P) death of a person in the house or workplace organization.


(4) In addition, reports of serious events, serious operational accidents and dangerous states
if they occur during

A) dealing with explosives, including accidents
poisoned fumes generated during the explosion, breaking into a warehouse, theft or finding
explosives

B) the use of restricted technical equipment including injuries
electric shock

C) operation of mining equipment, including injuries incurred in the operation of mining equipment
.

§ 22
Status quo
place of serious industrial accidents, serious incidents
dangerous condition and severe operational accident (crash)

(1) The place where the serious work accident happened or where there has been
serious incidents unsafe condition or serious operational accident
(crash) can not change anything until the District Mining Authority failed || | crime scene or decided otherwise, except when it comes to saving
affected by, or on another rescue or safety.
Changes required for other serious reasons, can only be made with the consent
District Mining Authority.

(2) The place of serious industrial accidents, serious incidents
hazardous condition and severe operational accident takes organization documentation, especially
sketch, plan, photo etc.
Part of the fifth

Basic documentation


§ 23

Documentation and records

(1) In addition to the books required by other regulations to ensure the safety
work and operations or specific provisions must be kept

A) the registration book, which must contain

First basic data on protected deposit area, mining area,
land ownership, zoning, building permits and
other important official decisions

Second basic data on the main mine workings and important buildings and facilities
a decision to authorize the start of their operation,

Third basic information on how mining and primary mining methods

B) mine or building log book in which shall be entered or establish
decision of the State Mining Administration,
central state administration bodies and organs of the public health service and social control
actions and statements relating to the organization safety and operating
rational exploitation of deposits,

C) book dams

D) books drainage

E) book of mine fires

F) a book of extraordinary events

G) of the book, in which supervisory authorities and other technicians
record the results of their errands and statutory inspections.

(2) Racing mine or the authorized officer determines where and how
books must be kept under subsection 1. a) to g).

(3) Records supervisory bodies, reporting data encoders, sensors, etc., U
which regulations to ensure the safety and operation require
form of books, can be performed in a manner that will allow the storage and use
data for a specified period.

(4) The statutory inspection, inspection, measurement and analysis are required to collect
workers who made them. Unless stated otherwise
, records must be kept for at least one year.

(5) The training, job training and examinations in accordance with regulations to ensure
safety and traffic must be kept.

§ 24

Mining survey and geological documentation

Mining survey and geological documentation ^ 15) must be routed so that
provide reliable data for the development of operational documentation.
PART TWO


Requirements on the working environment

§ 25


Canceled
§ 26


Canceled
§ 27


Canceled
§ 28


Canceled
§ 29


Canceled
§ 30
First Aid


(1) If the worker suffers workplace accident or suddenly become ill, he must
be given first aid and must be transported under escort to
medical facility. Transport victim takes precedence over another
transport.

(2) once every 3 years the organization shall ensure the training of technicians
Blaster, foremen, mine rescue instructors
secondary vocational schools and koupelářů about first aid. ^ 18)

(3) Verification of medical knowledge lows in first
assistance must be part of any examination of regulations to ensure
safety and operation.

§ 31

WC underground


(1) The underground mine to mine the reserved deposit must be established
toilets placed in suitable premises near the workplace, if possible in
výdušných winds.

(2) Lavatories must be equipped with lavatory truck or suitable container material
disinfectant and cleaning agents. They must be kept
clean and regularly disinfected.

(3) Means of transport for mining trucks toilet and lavatory tanks determines
traffic rules.

§ 32

Garbage and their removal

(1) In the basement is forbidden to throw garbage freely.

(2) nárazištích, platforms and other places designated by
organization, must be placed in a rubbish bin.

(3) Garbage must be regularly exported from underground.
PART THREE


Leadership workings
Part first



General Provisions
§ 33

The mine

(1) Mine must have at least two separated and independent
exits to the surface, each of which must allow the departure of all personnel from
underground.

(2) Mine, which are only conducted reconnaissance or works only
and on one floor, a pit in which only exploit natural healing and
mineral drinking water and mine at the end of the liquidation, or the provision of
may have one exit to the surface. This is true even if the exceptionally justified cases
exclusive field without a designated mining area
conquers organization that conducted or conducted its survey.

§ 34

Combination exits from the mine

(1) After excavation or excavation of early development of main mine workings
designated as exits from the mine to the designed floor or deepen their
new floor should preferably be stamped mines
to their union.

(2) Prior to the excavation workings to link the mine can be stamped only
mines needed to ensure the safety of another stamping
(pumping chamber, žumpovní corridors, etc.). Non-coal mine at neplynujícím
may also be stamped exploratory workings and mines needed to operate
(depot, warehouse of explosives, etc.).

§ 35

Exits from the workplace

(1) Workplaces must be safely walkable and accessible from the free East
any place and head into the mine workings, which can be achieved
exits from the mine.

(2) Base for strong mining in coal mine and stope wall
must always have at least two exits accessible from any place, of which one has
lead to vtažného and second výdušného into the mine.

(3) Residual pillar bearing can be justified in cases quarried
with only one exit from the workplace, but in the production process must be determined
necessary precautions.

(4) For other mining methods apply paragraph 2 that 2
exits must be directly from dobývky or at least her story, mezzanine, possibly
mining corridor.

(5) In the workplace, where the muck is transported by gravity shall be
exit from the workplace safely separated from the transport muck.

§ 36

Working in the vicinity of old or abandoned mines and other underground areas


Working in the vicinity of known or anticipated
old or abandoned mines and other underground spaces are allowed only after determining
necessary safety measures.

§ 37

Working at the frontiers of mining areas

(1) At the boundary of mining area adjacent mines must operate so
to operate these mines was negatively affected by one another.

(2) Precautions for work at border mining areas must
particular take into account the danger of rock bursts,
outbursts of rock, coal and gas, water and bahnin breakout, mine fires or mine delays
winds.

(3) As long as they are not intended for work safety measures at the border
mining areas, work must stop as they approach the border
mining area. Stopping distance of work is determined by
zálomového angle deposition conditions so as not to affect
used mines beyond the mining area.
But shall not be less than 20 meters from the border of the mining area and 40 meters from the nearest mine working
neighboring mine, measured in plan view.

§ 38

Contact with underground mining other mining activities or activities

Using mining methods

(1) Conditions for the simultaneous mining, quarrying
must be addressed in the plans of opening, preparation and extraction or exploitation plan
bearings so as not to adversely affect each other.

(2) Similarly, it is necessary to proceed with the possible influence of underground mining
other mining activities or mining activities
way.

§ 39

Principles of leadership workings

(1) Mining work must be guided by technological progress
drawn up in accordance with the terms defined in the authorization or
reporting work. ^ 19) Technological progress must conform to circumstances in which the mine
work conducted.

(2) Punching mines and mining method must be chosen according
mountain anticipated pressures and evaluation of properties and store
rocks, and also in terms of bedding, quality of bedding
areas, the ability to avalanching, danger drift like. Especially
detail must be studied rock layers on the bow 30 degrees
greater danger in terms of driving.

(3) Profile and reinforcement of the mine must match the durability and purpose
which will serve the mining work. Bolting can be used only in appropriate
mining-geological conditions in accordance with the technical
conditions of use. Frequency and method of load control
bolting down the technological process.

(4) The size of the frame, and technology stamping or possibly mining
renovations must conform to local conditions, in particular qualities
rocks and used by devices including the reinforcement.

(5) Mine works must be is reinforced so as to prevent rock falls.

(6) Disturbed part of rock must be timely torn down or otherwise secured.
The demolition and excavation of rock must be done from a safe place.
To this end it must be workplace appropriate working tools.

(7) Before approaching the mine to another mining work must be designed
measures to ensure the safety and operation, verification,
neproraženého pillar protection from the effects of blasting ^ 20) and adjustment of ventilation
. Likewise, it must proceed in parallel lines workings of
reach their mutual influence and before the breakthrough mining works on the surface
.

(8) for the safe management of coal mines in the vicinity of the excavated areas
organization shall decide whether it is necessary to keep in their neighborhood
pillars or protective caps. The dimensions of the pillars and safeguard caps
determined mainly by the expected pressures mountain, properties and buildings bearing and
surrounding rocks, as well as by the anticipated state
excavated or abandoned mines. If the dimensions are the pillars and safeguard caps
reliably known, must be verified by drilling.

§ 40

Places to increased pressures mountain

(1) Resources increasing mountain of pressures, especially heaps, dumps, geological
disorder, left pillar caverns spaces and places where
occurred as a result of pressure manifestations of the operational incident must be || | marked on the mine maps.

(2) For the safe keeping of mine works in places where they can express
elevated mountain pressures must be addressed in the technological process
special measures.

§ 41

Materials for reinforcement workings

To ensure a safe workplace must be prepared for the amount of
materials for reinforcement. Instead of storing certain technological process.

§ 42

Protection workings, utilities and other objects

Before excavation workings with surface or opening out on the surface
organization is required in the area of ​​the works to determine

A) engineering networks and cable lines,

B) underground spaces

C) leaks or sprain harmful substances

D) construction and other objects

E) distance and the nature of communications traffic on them
verify their status and determine the necessary measures.
If these facts discovered during the excavation, it is necessary to take the necessary precautions
or stop work.
Part of the second


Stamping and securing of workings

§ 43
Technological progress


(1) Technological process for stamping and securing of workings must determine


A) direction and slope excavation and profile of the mine work,

B) the manner and process of rock disintegration,


C) the impact of other mine workings or mining activities and the necessary security measures
,

D) conditions and stamping their expected changes

E) type of reinforcement, the spacing and the maximum permissible
distance from the face, quantity and place of storage materials for reinforcement and
way of establishment of free space for reinforcement, or kind of interim
reinforcement and replacement, interim reinforcement for permanent and machineries in the building
reinforcement

F) workplace ventilation and dust disposal,

G) special measures against mining shocks, water burst rocks, coal and
gas, water and breakout bahnin (zvodněných rocks), covering the surrounding
rocks or other hazards

H) machinery and electrical equipment for stamping and transport

I) the extent of their own workplace with defining responsibilities,

J) any other measures requiring workplace conditions.

(2) Annex technological progress must be a drawing of the cross, or even
longitudinal profile of the mine showing the locations
kits, transport facilities and coal mine explosion and
closures.

(3) The provisions of paragraphs 1 and 2 shall apply mutatis mutandis to the reconstruction
workings.

§ 44

Reinforcing horizontal and inclined workings

(1) Free space for the supports must be secured against loosening and
of the rock. The workings of hazardous ujetím rocks must be
these facilities are based.

(2) In gassy mines and coal mines in seams prone to spontaneous combustion
must be open spaces for reinforcements filled
tailings or other suitable material (§ 181).

(3) solid and cohesive rocks, except in danger of being elevated mountain
pressures and coal mines also places crossing or turning
workings, mines can be excavated and left without reinforcement if
they no danger of rock falls.

(4) Stability pliable steel reinforcement ensures a stretcher.
In the event that the mines excavated

A) harvesters

B) in areas in danger of rock bursts and outbursts of rock, coal and gas
,

C) the gross profile larger than 20 m2 or

D) of inclination greater than 10 degrees,
used at least three pieces of steel spreaders arranged at
closed reinforcement approximately 120 degrees on the circumference and open at
reinforcement on the ceiling of the work and after its sides.

§ 45

Striking tunneling and tunneling machines and shields

(1) Punching or longwall shield tunneling machine or (hereinafter
"stamping device") may be initiated after approval and workplace
defects which could impair the safety or operation.
Approval committee appointed by racing pit or persons authorized by them. The result
approval must be alert.

(2) stamping equipment can be put into operation until the departure of all
workers away from isolating the machine body.

(3) When moving a stamping facility for additional working step is not in the range
moving equipment do work that directly
nothing to do with this activity. After each shift foreman is obliged to check the condition
workplace.

(4) In an area where they are fitted reinforcement parts storage shall not take place
work that is not directly related to that activity.

(5) In front of the disengagement authority of the stamping device can enter
workers only for the purpose of exchanging cutting tools, maintenance or inspection equipment
face. Before entering this area must be inspected
unsecured part of the mine in terms of the danger of falling rocks and
checked mine air for traces of contaminants
at the face. Stamping equipment must be calm and
secured against actuation.

(6) Under the working platforms stamping apparatus
workers can detain only if prevent rock falls or objects from platforms.

§ 46
Striking extrusion


(1) At the start of the extrusion device can close
hydraulic machine parts delaying a worker who controls the machine.
With the shift may be at a face worker who gives the label instructions
extrusion equipment.

(2) When a shift is not in a pipe and in the inlet pit
perform other work.


(3) manually lifting the rock at the face extruded pipe is permitted only when
pipe diameter greater than 0.8 m. When using pipes with a diameter
less than 1 meter worker must be secured to the face
another worker outside and chained to a locking cable.

§ 47
Striking the chimneys


(1) Prior to the entry of the face mined chimney should be checked
mine air during the designated organizations.

(2) When working in the chimney must be workers and working tools
secured against falling into the depths.

(3) The chimney without separate lezního department must be ensured
possibility of understanding among workers at the base of the chimney and the chimney on the face.
Entry into the chimney is prohibited without prior understanding.
For walking or driving in the chimney should not be here performed no work.

(4) hoisting department mined chimney must be left in the muck
quantities required for safe access and work at the face of the chimney.
Technological process determines the conditions for the safe release of muck.

(5) If working simultaneously at different levels of the chimney must be
technological process intended measures to protect workers.

(6) Lower the mouth of the chimney must be ensured so that the workers
access corridor from falling rocks or objects from the chimney.

§ 48

Excavated using tunnel boring rigs

(1) Stamping platform may only be operated with the device providing
alternative transport workers.

(2) Before starting work on the platform must be sinking platform
stabilized by strutting into the sides of the mine.

(3) In the technological process shall be determined by the time and manner of controls
cohesion rocks mined the mine and the state of anchoring the track stamping
platforms.

(4) Material conveyed driving platforms must be stored and secured so as not to endanger
workers and allow the output to a working level.

(5) Equipment mined the mine must be built upon the latest
removing path punch platform.

(6) For the operation of boring platforms also apply special prescription. ^ 21)

§ 49


Shaft sinking
(1) Ústí shaft must be secured in an appropriate manner (by fencing,
threshold, railings, cross bars, etc.) Against falling objects and persons into
shaft. If the duct is not working, it must be safely
her mouth covered.

(2) Excavated soil or rock, tools and other objects must be
stored at a distance from the mouth of the shaft and such that
was expelled them fall into the shaft and the negative pressure manifestations stored
materials on the duct.

(3) If the mouth of the shaft on an inclined surface, it must be on the higher side
moat so that stormwater running into the shaft and
nerozmáčela its surroundings.

(4) If the duct deeper than 5 meters must be at a height of 2-4
meters above the bottom protective Rolling.

(5) The shaft to a depth of 15 meters must be equipped with a fixed ladder.
The shaft deeper than 15 meters must be equipped with a separate Leźnie
department with resting, the vertical distance should not be greater than 5 m
. A boundary separation can be replaced by a vertical ladder with protective cage
. Distance foot of the ladder lezního separation from reinforcement and equipment
shaft must be at least 0.3 meters.

(6) of the emergency exit shafts must be prepared lifeline
or escape ladder securely anchored to the surface.

(7) The shaft deeper than 15 meters must be equipped with warning signal device.

(8) When used in the extraction duct Single-acting hand winch must have
ratchet or self-locking transmission and brake. Unless
hand winch fitted with a retarder, it must be operated by two workers.

(9) Before the descent of workers must be ventilated shafts and verified that
is it safe atmosphere.

(10) The bottom of the shaft, if it works, it must be illuminated so that
reliably visible from the mouth of the shaft.

(11) When working in the duct must be ohlubni still present
least one worker.

(12) from the shaft may pave the mines within a distance of 50 meters.

(13) Unused shafts and workings of which must be stamped
immediately liquidated.

§ 50

Dredging and deepening pits


(1) dredging, excavation, reinforcing and equipping pit blind pit
Sibik (hereinafter referred to as "pit"), including nárazišť must be drawn
project under special regulations. ^ 21) ^ 22) | ||
(2) trench section between its base and constant reinforcement must be ensured
interim reinforcement. In solid rock may be the interim reinforcement
waived, under conditions determined by technological process.

(3) Workers at the bottom of the pit must be protected against falling objects protective
Rolling carried out under a special regulation. ^ 21)

(4) Deepens If the pit is at present extraction of the floors above the excavation,
must be to protect workers in the pit set up under the lowest floor
safety (protective) Rolling or left Celik. ^ 21) Protection
workers must deal with the project.

(5) Protective Rolling or rods can be removed only after full
wells or deepening the trench and excavation run into a specified distance
project.

(6) The procedures and precautions when removing the protective staging
Celik or certain technological process.

(7) Following the removal of staging or rods must be pit
equipping the time in the pit mined.

(8) When used with the deepening pit mining equipment must not be used during
work in the pit mining equipment is used for other purposes. In this way
deepening must be a time when workers are in the pit, locked
zátyňová doors on all floors, denied access to the pit
unauthorized persons and must avoid objects falling into the pit.

(9) Equipment for digging pits must be operated under a special regulation
. ^ 21)

§ 51

Digging in zvodněných or gassy rocks

If during excavation can expect bursts of water or gas or water inrushes
bahnin (zvodněných rocks) must be predrilling distance
specified technological process. Results of drilling a
must be evaluated and determined on the basis of security measures.

§ 52

Digging pits in the rock hard freeze

(1) Frozen bottom of the excavated pit must be checked at
predrilled distance determined technological process. Results of drilling a
must be evaluated and on the basis of security measures intended
against breakout unfrozen rocks.

(2) When water leakage must process a threat (§ 17
par. 1).

(3) The walls of the excavated pits and pit equipment must be deprived
ice stalactites. At the beginning of the shift and as needed during the course
must be checked whether the signal equipment is decommissioned for
ice.

(4) Oil shackle may be left after the shift to the bottom of the pit.

§ 53

Sinking with predrilled or předrážkou

(1) contact probe borehole or předrážky to the bottom of the pit must be secured against
workers fall into the depths. If this is not for technological reasons
temporarily possible, workers must be strapped protective harness with energy absorber fall
attached to the rope and the work must be carried out
constant supervision.

(2) A method for ensuring the safety of workers during excavation of the lower estuary
probe borehole or předrážky determine technological progress.

(3) When the probe borehole blockage or předrážky organization is required to determine
way to unwind and rock excavation. These works must be carried out as
work associated with increased risk.

§ 54
Reconstruction jam


Reconstruction pits must be carried out according to the plans drawn up by
special regulations. ^ 21) ^ 22) The project must also specify
safety measures to protect workers from falling into the pit, and against falling rocks and
subjects and attachment work staging.
A third part



Mining work
§ 55
Commencement of mining works


Mining work can be started only after the necessary
early development and preparatory work, meet regulatory requirements to ensure safety
work and traffic, particularly as regards ventilation, fire protection, protection against dust explosion
and gas and drainage and meet the permit conditions
opening, preparation and extraction and technological progress.
Meet these requirements must be checked by the organization and control of acquired
record.

§ 56

How to exploit coal seams and bearings


(1) seams to be mined in a row from the top down.

(2) Podrubání coal seams are only permissible for degassing very
plynonosné overlying seams or to release tension in the overlying seam with
danger of rock burst or potentially outbursts of rock, coal and gas
. When podrubání caving, the distance between podrubanou and
podrubávající seams such as to achieve the above effects and
avoid disabling pry podrubávané seam.

(3) For thick seams and seams tightly grouped, separated by
weak middlings can be footbridge or seam podrubána only once. When
mining thick seams of footbridges may be the upper walkway podrubána only
coal face with a full airing.

(4) Paragraphs 1 and 2 shall apply mutatis mutandis to any other type bearings.

§ 57
The mining method


The extraction may only be used mining method with which the district mining office
consented.

§ 58

Reinforcement and longwall stopes

(1) If mining technology requires reinforcement shall be constructed
as soon as her place. When mining must be elected
such a procedure, the newly opened area was secured as soon as possible reinforcements.
Where conditions require that ceiling should be immediately after the opening of the new space built
interim reinforcement.

(2) The method and the type providing reinforcement must be chosen so as to not have
temporary reinforcement in addition to mechanical support, converting
at various stages of mining.

(3) Providing temporary reinforcement must be completed no later than before the commencement
next conquest.

§ 59
Technological progress


(1) Technological process for mining must determine

A) the method and procedure conquest

B) the manner of disintegration,

C) the type of reinforcement and method of securing the coalface and dobývky including input
alley advance, niches and chapels, places of elevated mountain pressures
disorders etc., And the quantity and place of storage materials for reinforcement, || |
D) actions resulting from the anticipated conditions change during the conquest
influence and other mine workings

E) the size of the open space and measures for possible entry into
him, the thickness of the protective pillars or ceiling and method of verification
way to control the ceiling and causing a cave,

F) the reinforcement of looting at the coalface, dobývce and adjacent workings

G) the type and method of disposal of excavated area (establishment, etc.)

H) the method of excavation and transportation of spoil material

I) workplace ventilation and dust disposal,

J) special precautions against mining shocks, water burst rocks, coal and gas
, mine fires, water and breakout bahnin (zvodněných rocks), driving
accompanying rocks or other hazards

K) electrical and machinery for mining and transport and the way they
relocation

L) the extent of their own workplace with defining responsibilities,

M) any additional measures required in the workplace.

(2) Technological process for the extraction polostrmých and steep coal seams
must next determine

A) longwall move away from the fall line,

B) dimensions indicative zátinek,

C) Horizontal and diagonal downhill zátinky,

D) the size of the advance, niches and chapels

E) method of securing workspace against a cave or elementary school,

F) distance, location and method of construction of protective Rolling,

G) reinforcement adjacent corridors.

(3) Technological process for the extraction of leaching must determine

A) the preparation, composition and amount of leach solution,

B) way of handling acids and alkalis,

C) wastewater systems and solutions,

D) any additional measures required in the workplace.

§ 60
Conquering longwall


(1) Wall coalface must be provided reinforcement that corresponds
mining-technical conditions of mining. Racing mine or his nominee
worker can identify more types of reinforcement at the coalface, each of which must
be built in sections. Mixed reinforcement can determine if it is ensured
its reliable resistance and does not deteriorate if the quality of the ceiling.

(2) equipping and disposal mechanized longwall
complexes must be drawn up separate production process.

(3) on a longwall caving controlled or partial primary school must be

Management cave formed zálomová straight edge. When conquering the nadstropem
and intermediate ceiling must be created directly zálomová edge in the coalface
who is overwhelmed.

§ 61

Mining powerful seams and bearings longwall

(1) During mining thick seams and bearings in longwall bridges must be
for the extraction of the lower bench a sufficiently cohesive ceiling, either
compacted pile, reinforced or artificial cave ceiling.

(2) Poruby at the bottom of the footbridge can be kept under artificial ceiling only when
full or cave full of elementary school in the upper walkway.

(3) When combined conquering two more bridges must be mutual spacing
Associated longwall in the common hallways designed so as to prevent their mutual
adversely affected. In determining mutual
spacing must be also taken into consideration to ensure proper condition and maintenance
adjacent workings and ventilation.

(4) mining method, which is part of the seam simultaneously with extraction
lower bench and run before stitching the excavation (longwall with
nadstropem, intermediate ceiling, etc.) Can be used only where the nature || | overburden seams, tectonic fracturing or abandoned mines or other serious reasons
do not allow the safe use of other methods
conquest. This mining method may conquer
coal seam or a piece of a thickness of 7m.

(5) nadstropovém or mezistropovém space can be simultaneously operated
most two workers, including at least one with a minimum of one year experience on
such works. In this space can only work under constant surveillance
performed from the secured area. Conditions of entry into nadstropového
mezistropového space and determine technological progress.

(6) Vyuhlování nadstropu and false ceiling can only be initiated in
points against which the leading pillar secured. Length, number of simultaneously
vyuhlovaných sections nadstropu or false ceiling and their mutual
smallest distance determined technological process.

(7) If the thickness of the layers nadstropové known, must be verified by drilling
whose spacing determines technological progress.

§ 62

Mining polostrmých and steep seams and bearings longwall

(1) When conquering polostrmých and steep seams and bearings longwall
must be taken to make workers not at work
threaten each other and that they are protected against falling objects or
rocks.

(2) Reinforcement must be carefully constructed and mutually bound and clamping
such a way as to prevent danger driving accompanying rock
especially above the lower corridor. When seam thickness greater than 2 meters must be
indicative ceiling zátinky secured polygon reinforcement.

(3) Reinforcement of the corridor over the coal face must be secured against loosening even before its
podrubáním. Reinforcement of the corridor under the coal face must be properly
braced for a cover rocks.

(4) If it can not be used to safely walk or rise of filling
reinforcement coalface must be the entire length of the longwall mining ladders laid
secured against driving.

(5) Paragraphs 1 to 4 shall apply mutatis mutandis to other mining methods used during the conquest
polostrmých and steep seams and bearings.

§ 63
Coal mining komorováním


(1) Ústí chamber must have adequate reinforcement height and pressure conditions
chamber. Ceiling mouth must be properly lagged.

(2) crew compartment shall consist of at least two officials, of whom at least one
with at least three years' experience in the rooming. The chamber can work
only after a necessary period and only under constant supervision exercised from the mouth
chamber. The Chamber and its mouth must be properly illuminated.

(3) Power protection ceiling must match the nature and structure
mined seams. Unless power is known, must be verified by drilling, the deployment
determine technological progress.

(4) Where the mined catwalk suspects
old or abandoned workings, their locations should be determined předvrtáváním.

(5) of the Chamber must be established so that the old or abandoned mines in
powers Rubano footbridge fundamentally not in the first half of the chamber or
between the two chambers. If there is the unavoidable circumstances necessary to establish
chamber so that the old or abandoned mine will be in the first half
chamber must not be disturbed pillar above the mouth of old or abandoned mine
work.


(6) After the smelt chamber must be overwhelmed. If it fails to induce caving,
may be on the same mining corridor founded a new chamber only with the consent
racing pit or a designated employee while
determining the appropriate security measures. Unburdened chamber must be marked
in basic mining map. ^ 15)

§ 64

Mining zátinkováním and pilířováním

(1) Columns must be mined in parts of the old grass to avoid the smothering
premature. For this purpose, it must be ensured
own workplace an appropriate reinforcement and corridors are protected against stařinám
edge.

(2) Dobývka must be built up to stařinám. When conquering powers
over 4 meters must be the reinforcement of crosses and mine works near
dobývky strengthened.

(3) Blasting operations can be carried out in such a way as not to breach the stability
cross and upset pillar in its vicinity.

(4) Entering into the mined area is rarely possible when building
signaling props.

§ 65

Mining open-won space

(1) The dimensions of the pillars and mined areas shall be determined by
geotechnical properties of the bearing. The smallest holiday width
pillars must be maintained uniformly throughout their length and height.

(2) When conquering more floors must be interventricular pillars located
below.

(3) While mining on two floors can be mined on the lower floor
commence until after the liquidation of the pillars intended to hand zálomového angle
dobývky.

(4) If mining technology requires the entry of workers into the open
goaf, determine the conditions of entry technological progress.

§ 66

Conquering the temporary storage of spoil excavated there in space

(1) Working height dobývce must be determined by the geotechnical properties
bearings and accompanying rocks.

(2) During the conquest, leaving pillars at the border chimneys must be
exits from dobývky at rest areas in these chimneys.

(3) If there is a dangerous vaults in discharging muck
prevented by other means, shall be provided a sufficient number of outlets
suitable dimensions and ensure uniform discharge muck.

(4) During discharge muck workers must not remain on
dobývce and must ensure control and recording the quantities discharged
muck from the individual water outlets. When you suspect a vault
measures must be taken to determine the technological process
event of an arch.

(5) Technological process of identifying measures to prevent forfeiture
workers and their burial muck.

§ 67

Mining of ore and non-ore deposits Planting excavated spaces

(1) Working height dobývce must be determined by the geotechnical properties
bearings and accompanying rocks.

(2) If the pile does not provide sufficient support hips dobývky must be
workspace ensure adequate reinforcement.

(3) Designated pillar mining dobývce not be violated.

§ 68
Mining and leaching


(1) When leaching extraction of deposits, which was prepared for leaching
other mining operations must be prevented from penetrating
leach solution into existing mine workings.

(2) During mining of salt deposits must be monitored and surface subsidence
conducted regular measurements leached space in each borehole leaching
within the time designated organizations.

(3) In the extracts must be prevented from leaking outside the leach solution leaching
space.

§ 69
Looting reinforcement


(1) Looting reinforcement longwall can only be performed by dedicated personnel with
least two years' experience in the mining industry. When the looting is looting
required to reside only in a secured area and have secured the retreat
way.

(2) The foreman wheat reinforcement longwall must be qualified foreman for
lead mines and at least six months experience in the looting.

(3) Other work can be carried out looting the only unless
compromising worker safety.

(4) When the bow of the mine above 20 degrees reinforcement can be plundered only
bottom up.

(5) When machine looting must be reliable
separate signaling devices. Meaning label must be uniform for the entire mine. Must be

Confusion with the other label.

(6) on a longwall caving driven in seam with a thickness of 0.6 m must be
reinforcement edges or fence looted before getting another
miter. If caving ceiling or connection with the tunnel floor for zálomovou edge
lags more than a determined technological process, the reinforcement shall be plundered i
when mining coal seams at a thickness of less than 0.6 meters.

(7) lags If caving distance of more than
determines technological progress must be artificially induced caving. If it fails to induce caving,
may be continued conquest to modify the technological process and
implementing appropriate security measures to ensure the safety of workers
.

(8) The Sack of reinforcement at the coalface zálomovou edge can be initiated only after ensuring
newly opened space on the pillars and create a new zálomové
edge. In longwall must be observed density and uniformity of the reinforcement
deployment.

§ 70

Foundation excavated space

(1) If it is required to protect the surface of the reserve deposit or mine works
or there is a risk, especially driving the movement of rock or delay
mine air must be founded smelt spaces. Placement
excavated area can use only non-combustible and hygienic
material. Method and peace foundation, kind of elementary, execution and control equipment for transport
elementary and handling
determine technological progress.

(2) Establishment of the mined area must proceed immediately after the conquest
if mining method dictates otherwise. Distance from elementary
pillar must match the overhead conditions. Establishing space must be in full use
elementary completely filled with stowing material.

(3) foundation area must be safely isolated from the rest of the working
space so that workers there are not endangered.

(4) Partial backfilling including ribs to protect corridors
may be used only where there is not in its application to restricting or disabling
pry underlying seams.

(5) When partial elementary school must be a method of constructing the ribs and their
mutual distances correspond to its purpose and status of overburden.
Part of the fourth


Maintenance and liquidation of mines

§ 71

Maintenance workings

(1) All used mines must be maintained in a safe condition.

(2) The workings or parts thereof, whose condition is unsafe
workers are forbidden to enter, except the entry to remove
dangerous condition.

(3) Mine works or parts thereof to which is dangerous for their state
forbidden to enter must, with the exception of non-working spaces
longwall stopes and marked entry ban or withheld.

(4) Zmáhací work must be carried out according to technological progress or
under constant surveillance.

(5) Workers determining maintenance workings, which are
electrical equipment must be instructed on how to protect electrical equipment
including cables from damage.

§ 72

Disposal of mines and pillars

(1) If the method of disposal of excavated pillars and nezavalených
spaces and other mine workings is part of the mining method shall be determined
technological process or project.

(2) For the disposal of mine works looting also applies § 69.

(3) When disposing of long mining works related to the coalface
plynujícím II below. class of danger (§ 79) must be used instead of looting
sprinkled around the perimeter. When machine looting steel reinforcement must be
instead looting sprayed. In the surrounding looting must be continuously
measured concentration of methane in the mine air.

(4) When disposing of vertical mine workings and coal mines and workings
with inclination of 30 degrees is prohibited looting reinforcement.

(5) Assuming later surface mining of the deposit must be
liquidation of mining works carried out with respect to subsequent surface
conquest.

(6) Project nezavalených disposal of large areas must be addressed
safety and operation of the particular effects anticipated
pressure waves, seismic effects and manifestations collapse on the surface.

(7) The method of disposal of mine works must be indicated in the mine
map.
Part of the fifth


Special provisions for mines with a danger of rock bursts

§ 73


Spooler down in terms of the danger of rock burst

(1) Mines with regard to the risk of rock bursts are divided into two categories:

A) mines without danger of rock bursts,

B) mines with the danger of rock bursts.

(2) Mine in the category of hazardous mining shocks ranks
District Mining Office. This could also include part of the mine. Changing circumstances may
District Mining Authority at the request of organizations including canceled.
Uncategorized mines are regarded as mines without the danger of rock bursts.

(3) If the organization really justify the inclusion
down into categories with danger of rock bursts, is obliged to disclose
Subdistrict Mining Office.

§ 74


Canceled
§ 75


Canceled Part of the sixth



Roll on economy
§ 76
Establishing heaps


(1) spoil bank must be established in accordance with the project documentation
drawn up by special regulations. ^ 19) ^ 22)

(2) spoil bank for storing materials prone to spontaneous combustion or from which they can build
gaseous pollutants must be sufficiently distanced from the mouth
vtažného mine work, but at least 60 meters along the direction of the prevailing winds
.

(3) spoil bank must be established on an outcrop of the coal seam or layer
combustible mineral, if not above the layer of non-combustible rock thick
least 10 meters.

§ 77
Operation heaps


(1) To operate the dump must be developed technological process, which
determine safety measures for the storage and collection of materials, method of disposal
dust, providing machinery and equipment and, if necessary
measurements of temperature and concentration gaseous pollutants, cooling or fire
burning dump.

(2) Dump can be placed or removed from it matter so that
not to create conditions for self-ignition and spread of fire and
not jeopardize the stability of the heap.

(3) for dump flammable materials must not kindle the fire did not sprinkled
hot ash or slag.

(4) spoil bank, including its neprovozovaných parts must be checked at
least once a month.

(5) Access roads to the dump must be labeled with
tables with the prohibition of entry of unauthorized persons.

(6) During storage and collection of materials from the burning dump must be in the air at workplaces
dump detected the presence of carbon monoxide, sulfur dioxide and hydrogen sulfide
. Places with expected and identified the occurrence
gaseous pollutants must be identified.

§ 78
Documentation heaps


The mapping documentation ^ 15) must be mentioned how to store and recall
masses.
PART FOUR


Ventilation down
Part first


Ventilation and gassy coal mines
Section One



General Provisions
§ 79


Down Distribution
(1) Mines with the occurrence of methane divided into two categories:

A) neplynující mines

B) gassy mines.

(2) Neplynující mines are those mines where methane concentration is not reached in any
ovětrávaném mine workings where 0.1% and even after stopping ventilation for 24 hours
methane concentration fell below 1%, and the concentration of other || | flammable gas or vapor (hereinafter referred to as "gas") 25% of the lower explosive limit
. Fumes mine fires for inclusion mine
involved.

(3) of gassy mines, coal mines, with the exception of lignite mines and other mines
which do not meet the requirements set out in paragraph 2.
gassy mines are classified in Class II. or the first class of danger.

Mines II. class of danger are all mines of the Ostrava-Karvina coalfield
mines and hazardous outbursts of rock, coal and gas.

Other gassy mines are mines first class of danger.

(4) Any finding that could have an impact on the division
down into categories of gassy mines or danger to the upper classes, notify the organization promptly
District Mining Authority.

(5) Based on the measurement results referred to in paragraph 2 or on the basis
notification pursuant to paragraph 4 ranks the District Mining Authority neplynující mine
into the category of gassy mines and gassy mine hazard class I to II.
Hazard class. Gassy mine can not be re-transferred between mines
neplynující.

(6) The inclusion of the gassy mine or downshift to a higher hazard class
District Mining Authority also lays down deadlines
control measurements.

§ 80


Wind joints down to the surface

(1) Mine must have at least one main downcast and upcast one main
mining work.

(2) One of the main mine ventilation mine work can have mine

A) when otvírce down until the main junction and the main vtažného
výdušného the mine; This applies likewise when otvírce new floor

B) when performing only exploration or construction work, and not just on one floor
,

C) in providing or winding down (floor).

Ventilation these mines (floors) should be addressed in the project.

(3) upcast pit must be deepened in a timely manner so that their
bottom floor was just one floor higher than the initial floor of the same
windy area. Also downcast shaft must be deepened in time to
without serious reasons nedobývalo below the deepest vtažným floor.

(4) The provisions of paragraph 3 is satisfied even when the desired level is reached
floor pit blind (Sibik), which is in protective pillars
pit.

(5) Paragraphs 3 and 4 shall apply mutatis mutandis to the other main downcast and upcast
mines than the pit.

(6) If there is no other way ensured that the icing on the main downcast
Excavation will not threaten the safety and operation shall be downcast
winds heated to at least + 2 degrees Celsius.
Open fire must not be used for direct heating vtažných winds.

§ 81

Ways ventilation

(1) Mine, except as provided in § 82 para. 2 must have a separate
mine ventilation system. Method mine ventilation must be suction.

(2) The mine must be ventilated artificially and continuously except discontinuation for
necessary to verify the presence of methane gas (§ 79 para. 2) and for the maintenance
main fan and power supply network. In other cases it is necessary
interrupt ventilation must be discussed with the District Mining Authority
.

(3) Mine works, apart from abandoned mines and excavated spaces
must be ventilated either průchodním air current or separate ventilation
if this ordinance does not allow any other way.

§ 82

Relations with neighboring mines

(1) The workings of the merging gassy mines must be to isolate
wind systems built dikes objects ^ 24a). In case that the perineal
objects are equipped Barrier doors must be constructed in such
number and distance from each other that at least one is always closed. On
neplynujících mines is sufficient to insulate ventilation structure-24b).

(2) Contact the wind power system down without insulation is only possible with the consent
District Mining Authority under the terms set by the proposal
racing down a demonstration of the necessary measures to ensure the safety and
operation, especially for disposal coal dust explosion establishment
cap, limiting the concentration of methane, ensuring stability
ventilation and rapid closure of the větrního
connections.

(3) If several mines into one větrního system are racing
down or their designated staff to promptly discuss the changes and
events that may affect ventilation, especially on the composition of mine
air, and emergencies and accidents that threaten neighboring mine or
requiring synergies associated mines. Planned changes must be
discussed in advance. These hearings must be made
record.

(4) Create a new connection větrního down or change its involvement in Větřní
system down is considered a substantial change in ventilation.

(5) When connecting several mines into one větrního system without insulation
determine the organization professionally qualified person ^ 24c) responsible for coordinating the activities of the leading ventilation
individual associated mines.
Section Two


Mining winds and wind path

§ 83
The composition of mine air


(1) in mine workings, where the stay or can stay
personnel mine air must contain at least 20 volume% oxygen concentration
and the following gaseous pollutants ^ 16) must not exceed the following values ​​
:
carbon monoxide (CO) 0.003%
carbon dioxide (CO2) of 1.0%,

nitrogen oxides (nitrous gases) (NO + NO2) 0.00076%
hydrogen sulphide (H2S) 0.00072%.

(2) work in the mine air with a concentration of carbon monoxide in

0.013% is possible provided that the average concentration of carbon monoxide
per eight-hour workday or a shorter
exceed the value specified in paragraph 1 and for the duration of the work will be continuously
measured concentration of carbon monoxide in the mine air .

(3) Racing mine may temporarily authorize a reduced concentration of oxygen
up to 19% and increased concentration of carbon dioxide
up to 1.5%, but at the same time is obliged to enact measures to eliminate this
state.

(4) The concentration of methane in the mine air workings, where
reside or resided workers must not be greater than 1%.
Only in places that are beyond the effective range větrního current is allowed
local methane concentration to 2%, but it must be done
necessary measures to remedy this situation.

(5) If possible, using readily available technical measures
reduce the methane concentration to the limits set out in paragraph 4, may give
racing down the necessary time with the written consent of increasing concentrations of methane
|| |
A) up to 1.5% of all wind currents including workplaces, except
longwall mining with úpadním leadership Winds (§ 95 para. 3) and the total
výdušného větrního current

B) up to 2% in průchodním upcast air current for the last
department up to the total výdušnému větrnímu current.
This increased concentration of methane can not afford, if the connecting corridor upcast air stream
led downhill. Written consent may issue a maximum of six months.

Elevated concentrations of methane caused by a lack of ventilation paths cross
can race down only afford to work to eliminate
this state.

(6) The written consent referred to in paragraph 5 is racing down
must indicate the period for which this issue, and simultaneously determine

A) technical measures to reduce the methane concentration and prevent
methane layers

B) the manner and frequency of checks to the concentration of methane, mine
sampling air in the harshest places, at least once every 14 days and kept
downhill upcast air current also measure the speed of mine
winds at least once every 14 days ,

C) monitoring the concentration of methane in the mine air
continuous methane analyzers signaling. In mine workings with
electrical equipment must be such analyzers registration and
equipped for automatic switching off electrical equipment when exceeding specified limits
. Location of sampling probes or sensors analyzer determines the organization

D) charged with monitoring equipment at least once each working day
associated with the control of the concentration of methane in the mine air and accuracy
continuous data analyzers methane, coal dust and destruction
state explosion barriers, fire fighting equipment
for divorce winds. This control should not be entrusted inning technicians.

§ 84

Volumetric flow mine air

Volume flow mine air in mine workings, where
reside or resided workers must be such as to ensure compliance with the requirements of this ordinance
.

§ 85

Current velocity

(1) The current velocity must be at least

A) 0.15 ms-1 excavated in vertical mine workings,

B) 0.2 ms-1 at the mouth of chambers

C) 0.5 m.sec-1 if the concentration of methane in the mine air is greater than
0.5%

D) 0.3 ms-1 in other workplaces, except workplaces listed in §
95 para. 3rd

Current velocity in gassy mines must be such that
prevent the formation of methane layers if their formation is prevented
otherwise.

(2) current velocity shall not be greater than

) 4 ms-1 in early development and preparatory workings workings of a
stopes,

B) 10 ms-1 in other mine workings with walking or regular
transport people

C) 15 ms-1 in other mines without walking a regular transport
people.

(3) In the mines, if not allow any transportation or walking
people, not current velocity is limited.
Section Three


Main and auxiliary fans

§ 86


Home fans
(1) plynujícím below must be the main fan is placed on the surface
at the mouth of the main výdušného mining work at other mines near the capital
výdušného the mine.


(2) Main upcast pit mine work plynujícího
must be equipped with at least two equally powerful main fans, one of which is
backup. Neplynujícím on the bottom and on such plynujícím below, in which the
possible that other upcast pit in time took windy area fan
pledged for the disorder, just one major fan
backup drive backup and transfer driving force.

(3) The fan must be equipped with devices to measure the pressure drop
(depression) signaling sudden changes in dispatching.
Sampling probe must be positioned to sense the pressure drop across the mine ventilation
area.

(4) The fan must have two supply lines electricity
carried out under a special regulation. ^ 27)

(5) Before the main fan to permanent operation or when
substantial change its parameters must be verified
its operating characteristics. Operating characteristics must also be verified
least once every seven years.

(6) The operation of the main fan without a machinist is allowed, provided it meets the requirements of §
fan 219. Operational security system must have
energy source independent of the fan drive.

(7) Channel main fan must have a closing device and must be
accessible from the surface.

§ 87

Maintenance of the main fans and their accessories

(1) the operation of the main fan is obliged to inspect the designated
worker at least once a day.

(2) Backup main fan is obliged to inspect and check
designated officer at least once a month.

(3) The fan and its accessories must be thoroughly
checked at least once a year and, if necessary, cleaned and conserved
; u jam with a skip profiting, however, at least a half
year.

(4) during the repair of the main fan and the main backup
fan is racing down or person in charge shall determine
necessary precautions.

§ 88

Measures in stopping the main fan and fault ventilation

(1) Stop the main fan or change the way it works
is permitted only on the written order of a designated official.

(2) When you stop the main fan or when a severe failure in the ventilation
must follow the emergency plan.

(3) After resetting the main fan or removal
serious disturbances in ventilation can be occupied workplaces and
electric current is turned on only after verifying that the ventilation complies with the requirements of this ordinance
.

§ 89


Canceled
§ 90

Makeshift fans

(1) auxiliary fan can be used for that part of the mine where the
you can not otherwise meet the requirements of § 83, 84 and 85. The deployment výpomocného
fan and the conditions of its operation will decide the race down to || | basis for calculating ventilation, and only to the extent necessary. When
stop výpomocného fan must follow the emergency plan
.

(2) Inclusion výpomocného fan in mine ventilation network, his removal from the
and change its technical parameters is considered a substantial change
ventilation.
Section Four


Distributing mine air

§ 91

Leadership mine air

(1) downcast winds must be routed to the appropriate floor or deepest
place and from there the shortest way to the mine ventilation porubům and dobývkám.

(2) upcast winds must be kept horizontally or ascending. The downhill
management of these winds is permitted under the condition that the speed větrního
flow will exceed 0.6 ms-1 and will meet the requirements of § 182 paragraph. 1
point. b).

§ 92

Wind ways

(1) as wind paths can be used to viable mines and
mine ventilation holes with a diameter of 0,3 m or chimneys without lezního
department of transport equipment or if not used for the transport of spoil.

(2) When disposing of workings ovětrávaných průchodním air current
can be used for ventilation and impassable mines. In a written statement
organization is required to determine

A) the location and frequency of indications of gaseous pollutants sampling and mining
air for analysis,

B) equipment crew portable device for measuring the concentrations of gaseous pollutants
,

C) the daily control of ventilation, mine ventilation pathless path

D) temporal restrictions on its validity.


(3) Cross sections of ventilation paths must be such as to allow
observe the speed limits and required volumetric flow rate of the mine air
terms of compliance with the specified composition of mine air.
Light cross paths with the exception of ventilation and longwall stopes and prorážek, chimneys, bridges
of ventilation and wind holes shall not be less than 4 m2.
Internal cross-section of ventilation pathways associated wind currents of two or more separate
Department of ventilation must not be below II. hazard class less than 8 m2.

(4) Excavation, which regularly transported, when calculating a net section
mine ventilation paths must cross section of the mine work subtract
cross conveyor equipment, or even cross-section of the stored material.

(5) of viable paths of ventilation must be possible to transport materials.

§ 93

Individual
Wind department
(1) Mining winds must be distributed via so as to establish a separate
mine ventilation department, and it has been for preparatory workings.

(2) Individual Wind departments and related downcast and upcast wind currents
may be mutually interconnected, just for essential purposes.

(3) below II. Class of hazard may be at podpatrovém
mining in each separate department Větřní one coalface or dobývka. The mine
works connecting downcast and upcast winds within such větrního
department must be built in places designated plan for opening, preparation and extraction dikes
objects.

(4) Beginning and end of a separate ventilation section shall be given in
plan for opening, preparation and extraction, marked in Větřní scheme and
identified in mines.

§ 94

Insulation wind currents

(1) wind currents must be isolated in mines forming
unwanted connections (shorts)

A) between the main vtažnými and výdušnými air current,

B) Větřní between separate departments

C) Větřní between individual departments and related vtažným or výdušným
air current,

D) between the United vtažnými and výdušnými air current,

E) inside a separate ventilation section.

Wind currents must be insulated Barrier objects
Větřní objects or other appropriate means, and in such numbers, and design
distances in order not to hamper ventilation. These requirements must also meet
insulating objects of ventilation holes interconnection traffic, possibly
bins.

(2) If several main mine workings výdušných must each
windy area on the side of the upcast insulated against others. On plynujícím
below must be výbuchuvzdorná isolation.

(3) below II. hazard classes must build the sites referred to in paragraph 1
point. a) to d) perineal objects. In other cases
sufficient ventilation structure.

(4) In the event of extraordinary importance of dam doors must ensure their proper functioning
suitable device. These cases will determine the organization.
Function check of the dam doors must be secured signaling
extending into the control room or place a permanent service. Exceptionally
function of a suitable device, possibly signaling to ensure constant patrol.

§ 95

Ventilation and longwall stopes

(1) Poruby and dobývky must be ventilated průchodním air current, except those
longwall stopes and in which mining method is a method of ventilation
required.

(2) Ventilation must be adjusted so that the mine winds flowed along
quarried pillars and gassy mines horizontally or ascending
except as provided in paragraph 3. A local leadership úpadním
winds through the fault or the wavy store determines the organization
necessary precautions.

(3) The downhill management of mining coal face of winds is possible if the concentration of methane in the mine
atmosphere at the coalface not exceed 1% and the rate větrního
current stope is less than 1 ms-1.

§ 96

Wind and dikes door

(1) The Wind and dikes doors must be self-closing.
Not remain unnecessarily opened. As soon as the need for them, they must be planted
or secured in an open position. Where to open the door
endangering proper ventilation must be built at least two in a mutual
distance that some of them were always closed.

(2) In mine workings with regular transportation machinery must be perineal

Door remotely controllable.

(3) Barrier object with a passage for the conveyor can be used only in exceptional cases
consent racing down. When consent
determined racing down measures to ensure the safety and operation at
maintenance of the facility and disposal of coal dust in its surroundings and
way his control.

§ 97
Wind curtains


Instead of air doors can be used 2 wind curtains, but only when
where a leak impede distribution of mine air and where they can not be
built or properly maintained air door.

§ 98
Wind bridges


(1) The Wind bridges can be used only if it is not possible to solve
lead mine air otherwise. Wind bridges must be tight and made of non-combustible material
.

(2) Wind bridges, which are kept mine winds
several separate departments of ventilation must be built plynujícím down
výbuchuvzdorně. At the bottom II. Class risk must be all wind
bridges built výbuchuvzdorně.
Section Five

Auxiliary ventilation


§ 99

Ways ventilation neproražených workings

(1) Neproražené mine work must be ventilated separate ventilation ^ 28)
whenever it is determined to ensure the composition of mine air or when
distance from the face průchodního větrního flow amounted to plynujícím
below 5 meters, neplynujícím to below 10 m.

(2) One lutnovým pulling permitted to ventilate more than 2 neproražená
mines, the mine II. class of hazard may be bored only one
of them.

(3) below II. Class of hazard may be an uphill corridor that is not
penetrated to the upper floor, coined another mine work only for the purpose of achieving
větrního connection and always just one department.

(4) upcast winds that flows from neproražených workings
new floor must be plynujícím down discharged directly into the overall výdušného
větrního stream or stream větrního separate ventilation section, which are ventilated
other workplaces where coins or conquered. Unless
meet this requirement is technically possible, it is allowed on written order
racing down the upcast winds bring to the workplace upper floor;
If necessary degas the workings of the new floor must be working in the separate
Větřní department stopped and workers
recalled.

(5) Neproražená mine works neplynujícím down, which can not be
technological reasons (using tunnel boring platforms, etc.).
Establish a separate ventilation is possible with the agreement of the racing mine or his authorized
worker ventilate the compressed air.

§ 100

Approaching plynujícím horizons and stařinám

(1) When opening plynujícího term must be mine work, which
closer to 10 meters away to such a term coined
with predrilled safety předstihujícími forefield least 5 meters.
On these sites must be constant monitoring of the concentration of methane, carbon dioxide possibly
continual analyzers.

(2) Once you start to mine work to stařinám a distance of less than 10 meters
organization is required in the production process to determine the measures to protect against sudden
gassing.

§ 101
Separate ventilation


(1) separate ventilation should not be at any point průchodního větrního
current consumed more than 70% volume flow mine air.

(2) Type separate ventilation, placement of fans and silencers
Bringing Luten průchodního větrního to stream their lengthening or shortening
, stringing, joining and sealing and method of disposal
exhaust dust must be given in the technological process.

(3) To be used other than metal ventilating pipes must be of a material that does not support
spread of fire.

(4) Supple unreinforced ventilating pipes should not be used on the suction side
fan lutnovém strength.

(5) Separate ventilation must be continuous except for interruptions for a period
necessary to verify the presence of gases (§ 79 para. 2) and for the maintenance
fan and its supply network.

(6) After the interruption or failure of a separate ventilation makes the organization
appropriate security measures to ensure the safety and operation.


(7) Separate ventilation may be after an interruption or failure restored after
finding that this could happen without the danger that could cause
discharged mine winds. The workplace can be cast and
electric current is turned on only after verifying that the ventilation complies with the requirements of this ordinance
.

(8) Further conditions for development, operation and control
separate ventilation in gassy mines by special legislation. ^ 28a)

§ 102


Canceled Title six


Mine Ventilation outlets

§ 103

Ventilation mining businesses, chambers and warehouses

(1) depot (tie), mine locomotives, plant machinery with diesel engines
, establishment, stationary refrigeration equipment, electrical
stations, warehouses explosives-20) and the storage of flammable liquids and solid lubricants
, including emergency storage of flammable liquids and solid lubricants,
must be ventilated continuously.

(2) Other mining establishments, chambers and warehouses to 5 meters in
plynujícím bottom and 15 meters below the neplynujícím not be
průchodním ventilated air current or separate ventilation, if
ovětrávání ensured their diffusion. In these areas is not permitted
local methane concentration according to § 83 paragraph. 4th

(3) in the chamber for charging the battery may be hydrogen concentration in the mine air
greater than 0.5% and must be secured at
twelve-air changes per hour. If the chamber is ventilated
separate ventilation fan should be located outside the chamber and the charging operation
rectifier unit functionally coupled to fan operation.

(4) In storage of flammable liquids and solid lubricants, including standby
storage of flammable liquids and solid lubricants, and in the establishment where the
handled these substances or gases must be provided at least quadruple
air changes per hour and the concentration of gases in the mine
air shall not exceed 25% of the lower explosive limit.

(5) In the premises with a stationary cooling equipment must be secured
volume flow mine air at least 3 m3.s-1 per 100 kg
refrigerant compressor unit with the highest load. If upcast winds from the establishment
discharged directly into the overall výdušného větrního current
tenfold sufficient air changes per hour.

(6) chamber with an oil transformer or electrical equipment with
oil filling and storage of flammable liquids and solid lubricants, including
standby storage of flammable liquids and solid lubricants must be
ventilation to upcast winds of them have already been used to ovětrávání
workplaces where coins or conquered.

(7) Electrical stations and storage of flammable liquids and solid lubricants, including
standby storage of flammable liquids and solid lubricants must not be
ovětrávány air current, which is allowed for the increased concentration of methane
according to § 83 Sec. 5 point. b). In these areas is not permitted
local methane concentration according to § 83 paragraph. 4th

§ 104
Ventilation niches


Niche to a length of 3 meters with transient cooling equipment or
electrical equipment and other niches within 5 meters in plynujícím
down and up to 10 meters in length neplynujícím below may not be ventilated
průchodním air current or separate ventilation if their
ovětrávání ensure diffusion. In an alcove with unsteady
cooling equipment or electrical equipment is not allowed
local concentrations of methane according to § 83 paragraph. 4th
Section Seven


Ventilation temporarily vacant and abandoned mines

§ 105

Temporarily unoccupied mines

(1) temporarily unoccupied separately ventilated mines must continue
ventilated.

(2) temporarily unoccupied mines unless they are viewed
supervisory authorities must be marked with a cross terephthalate or withheld on
plynujícím down within a distance of five meters and neplynujícím down
no more than 10 meters from průchodního větrního current. In doing so, at plynujícím
below must be complied with at least the following measures:

A) mining work available for more than one shift must be marked terephthalate
cross

B) mining work available for more than 3 shifts weekdays must be withheld
whole profile such that it enters
was not possible without damaging or removing inhibitions were maintained while
ventilation.

§ 106

Abandoned mines


(1) abandoned mine must be closed as soon as possible, except
excavated area, where it is reliably prevented delay mine air through
old grass and along which we must continue to maintain the corridor.

(2) below II. Class of danger and at other mines where
risk of accumulation of explosive mixtures must be abandoned mines
výbuchuvzdorně closed, except neproražených temporarily abandoned mine
works, which are unrelated to Starin and in whom no option | || initiate explosion. These mines is permitted for a maximum of six months
a tightly closed, in places výbuchuvzdorných future dams.

(3) The gassy mines II. Class dangers sampled
mine air from the space behind the dam, performs their technical analyzes
oxygen, methane and carbon monoxide and dioxide and measure the pressure of air
behind the dam at least once every three months, behind the air enclosures ^ 20a)
least once a month. On the other mines determine the frequency of sampling and measurement of air
air pressure behind the dam and Větřní mine closures racing.

(4) Paragraph 3 shall apply to the dam, behind which is demonstrably
filled enclosed space and dikes enclosing mining
hall at the chamber conquest. The fact that a closed space behind the dam is filled
, is recorded in the book of the dam (§ 188).

(5) Status and tightness of dams and wind seal is checked at least once
14 days. Inspections are also measurements of concentrations of oxygen, methane and carbon dioxide
monoxide and before them.

(6) The results of inspections of dams and wind shut off and the test results
air and air pressure measuring them are entered in a dike.

Section eighth

Check ventilation and apparatus for measuring concentrations of gases and gaseous pollutants


§ 107

Map ventilation and wind diagram

(1) for the mine to be developed and completed map ventilation ^ 15) and
mine ventilation scheme.

(2) On the map ventilation must also be marked down mines adjacent
up to 100 meters away from the common border with details of their
ovětrávání and way possible closure, seizure or destruction.

(3) wind diagram must show

A) the method of interconnection of wind currents in ventilation network,

B) a separate mine ventilation department and designation of nodal points

C) the position of a longwall stopes,

D) flow directions and volume flows of mine air,

E) the location and types of facilities for the distribution and control of mine air
including dams,

F) the location of the main and assistants to fans stating their performance
and pressure.

(4) wind scheme must be replenished so as to reflect the actual state
ventilation.

§ 108

Guided trips of ventilation and ventilation equipment

(1) Main downcast and upcast mines must be inspected at least once every six
year.

(2) wind paths within a separate ventilation section
must be inspected every working day, including individual mine ventilation department
least once a week.

(3) Process inspections or inspections of ventilation holes and chimneys, which are not equipped
Leźnie department or transport facilities, determine
organization.

(4) During inspections of ventilation routes must be simultaneously controlled and
equipment for distribution and control of mine air.

§ 109

Checking the composition of mine air

(1) The concentration of methane in the mine air plynujícího mine must be checked


A) in the occupied workplaces, in places where they are staying and
workers in výdušných winds of longwall stopes and workplaces
during inspections carried out pursuant to this Decree,

B) at a windy road with traffic locomotives with diesel or electric motor
, in the inning, in which it is transported; Places checks
designate organizations in the transport order,

C) in areas with electrical equipment and around 20 meters, but
towards the cave only if it is safely possible.
Check must be made before the electrical equipment while it is running at intervals determined
organizations before restarting if
interruption lasted more than 3 hours.

(2) In workplaces with danger of outburst rocks, coal and gases

Workplaces enabled enhanced methane concentrations according to § 83 paragraph. 5
and separately ventilated workplaces plynujícího mine are obliged
concentrations of methane or carbon dioxide also check
leaders or appointed staff at the beginning of the shift and
intervals designated organizations.

(3) neplynujícím down the organization must determine the intervals and places where
must be tested by the possible presence of methane.

(4) possible occurrence of gaseous pollutants (§ 83), especially oxides
monoxide and carbon dioxide in the mine air must be tested in places and
intervals to be determined by the organization, but always there arises
suspicion of their occurrence.

(5) The results of workplace inspections shall be communicated to the foreman.

(6) If it is exceeded specified concentrations of methane or
carbon dioxide or carbon monoxide in concentrations greater than 0.001%
must be the cause of an increased incidence and
Appropriate security measures.

§ 109a

Gas analyzers methane and carbon monoxide

(1) Constant monitoring of methane concentration methane
continual analyzers must be carried out in gassy mines

A) in a separately ventilated Excavation of electrical equipment where the
coins or conquers, with the exception of separately ventilated corridors longwall mining at
darkroom,

B) to work with moving machinery driven by an electric drive, which is ventilated
průchodním air current, and which can not be excluded
increase in methane concentration above 1%

C) in the upcast air current separate ventilation section and wind
areas

D) in the upcast air current from the site where it has been authorized
increased methane concentration (§ 83)

E) in gassy mines II. class of danger in the upcast air current from each
coalface

F) when operating overhead traction locomotive transport in the environment without
risk of methane explosion (BNM) where in contact with mine works
classified in environments with increased risk of methane explosion (SNM)

G) other places designated racing down.

(2) Electrical equipment for gassy mines II. Class dangers
that under § 242 paragraph. 1 shall remain in operation, and must be turned off
must be in areas referred to in paragraph 1 off automatically.
This provision does not apply to cases referred to in paragraph 1. C).

(3) Constant monitoring of the carbon monoxide concentration
continuous analyzers shall be carried out in coal mines

A) upcast flow of each separate ventilation section and upcast
current windy area,

B) in the seams prone to spontaneous combustion in the downcast air current
separate ventilation section and upcast air current stope and
separately ventilated mining work, which is punched or conquers, except
longwall corridors separately ventilated workings,

C) in the downcast pit, where the danger of carbon monoxide from entering surface
resources to mine

D) other places designated racing down.

(4) The distribution of individual sensors, gas analyzers shall be in
operational documents and marked in the map of the emergency plan. ^ 81)

(5) The operating documentation must be provided for cases
threshold is exceeded continuous analyzers and disorders
measuring devices.

(6) The concentration of methane and carbon monoxide detected
continual analyzers must be routed to one place and records
concentrations must be kept for at least 1 year.

§ 110

Measurement and sampling of the mine air

(1) Volumetric flow rate, temperature and relative humidity of mine air must be measured in
plynujícím down at least once a month, in neplynujícím down
least once every three months

A) the main výdušných mines windy area,

B) in výdušných workings of ventilation separate department

C) in výdušných mine workings near the coal extraction and stopes,

D) in the mined separately ventilated mines,

E) in mine workings with the operation of electric locomotives.

In these places must also be sampled mine air and
performed their technical analyzes on oxygen, methane and carbon monoxide and dioxide
.


(2) current velocity Longwall, stopes and driven separately ventilated
workings must be measured in plynujícím down
least once a month, in neplynujícím down at least once every three months.

(3) The sample mine air for the technical analysis methane must be removed
once a month even for electrical equipment. In the group
electrical devices from a distance more than 50 meters apart in the same
air current is sufficient sampling at the electrical device in which it can be assumed
highest concentration of methane in the mine air.

(4) In areas where blasting is carried out must be within the time limits specified
organizations sampled mine air
to determine the concentration of nitrous gases and carbon monoxide. Sampling
mine air must be randomly checked for length and
waiting period after the blast.

(5) in the chamber to charge the battery in storage of flammable liquids and solid lubricants and
at the facility, where handling these substances must be sampled
mine air to detect hydrogen concentrations, possibly
other gases, at least once every three months, at a time when you can
assume their highest concentrations.

(6) Analysis mine air samples to check its gaseous components
other than those listed in paragraph 1. a) and b), and the places in which it is allowed
increased concentration of methane according to § 83 paragraph. 5 may be replaced
measuring instruments and aids allowed under special
regulation. ^ 29)

(7) Measurement of radioactive contaminants in the mine air is performed by
special regulations. ^ 16)

(8) The results of the measurement and analysis of mine air downwards II.
hazard class must be submitted to the District Mining Authority until the end of the month
following the measurement and analysis.

(9) Sampling mine air is carried out according to CSN 83 0050th
To overcome the negative pressure in the sampling for wind lock and dams, and when
remote sampling mine air can be used only ejector or suction
pump; before the sampling is to be carried out exhausting air from
sampling tube and sample, at least fivefold in value
internal volume of tubing and sample.

(10) The sampling of the mine air enclosure
records the mine air pressure in an enclosed space.

§ 111
Barometric Pressure Measurement


(1) On the surface, the mine must be measured barometric pressure.
Measured data must be recorded and the records kept for at least six months.

(2) About falling barometric pressure must be informed workers
before going down into the pit. A sudden or significant drop in barometric pressure
must be informed of all technicians and leaders at the mine in
during the shift.

(3) The organization shall identify the necessary precautions for
cases of sudden increase in the incidence of methane and gaseous pollutants at
drop in barometric pressure.

§ 112

To buildup of methane and gaseous pollutants and detects Fukač


(1) If it is found that the composition of the atmosphere in the mine workings, where
reside or resided workers does not match § 83 must be
workers from these workings brought out into the wind and the vtažných
mining works must be marked entry ban. To remove this
status must be determined in the contingency plan.

(2) Re-occupation of workplaces and turn on any electrical equipment
permitted after checking that ventilation, especially mine air composition,
meets the requirements of this Decree.

(3) Any finding Fukač must be immediately reported to the organization that
required to identify measures to prevent its adverse effects.

§ 113
Wind balance sheet


(1) The Wind balance sheet must be prepared for each mine at least once a year and always
a substantial change ventilation.

(2) The balance sheet of the Wind is a report containing

A) a description větrního system with the characteristics of mine ventilation network and distribution
mine air, information about major vtažných and výdušných workings
principal and assistants to fans (including unloading operating point)
windy area and their division into separate departments of ventilation,
amounts of mine air in different branches of mine ventilation network, a description

Separate department of ventilation (work stations, interconnection,
isolation.)

B) a total balance of mine ventilation supplemented by calculating the equivalent holes and
data on the suction surface

C) a description of ventilation losses and faults in calculating the coefficients use of mine
winds (total and Faces and dobývky)

D) assessment of the current state of ventilation with regard to layout and depression
resistance in ventilation network segments and evaluation of ventilation paths
excessive pressure loss, stability analysis, diagonal links and overall
divorce mining winds | ||
E) appreciation of gas and climatic conditions,

F) assessing separate ventilation

G) drained a description of the system and related equipment, the amount of exhaust gas
(in whole or in sections), degassing efficiency and its
evaluation

H) assess the condition of ventilating the mine in terms of outlook and requirements of this ordinance
or special regulations ^ 16)

I) measures to eliminate the shortcomings of the current state of ventilation due to the outlook
mine ventilation with deadlines and persons responsible.

(3) Wind balance sheet must contain the following attachments:

A) map ventilation

B) wind diagram

C) depressing image mine

D) a table of indicators ventilation workplaces

E) Basic data sheet Wind,

F) technical data and assistants to the main fan.

(4) Wind balance sheet must be within 2 months after the measurement is made
District Mining Authority.

§ 114

Leader ventilation

(1) For each mine must be designed ventilation chief and his deputy.

(2) Deputy Head ventilation must be a mining engineer with
least two years of professional experience in the ventilation of mines or mining engineer with a complete
secondary vocational education to at least six years of professional experience in
mine ventilation.

§ 115

Conditions for using instruments to measure the concentration of methane and gaseous pollutants


(1) device to measure the concentration of methane and gaseous pollutants must be
indicate the type and registration number.

(2) An employee dedicated to the measurement apparatus must be trained in its use and
examined. Examination must be repeated every two years.

(3) The instrument may be issued or transferred only workers who have been appointed by him
measure.

(4) The device must be tested prior to dispensing.
Worker is obliged to pick up the instrument personally verify its function. Faulty devices are
not pretend to be, or should be returned immediately. Workers are obliged
assigned devices to protect against damage and may not
open.

(5) When you turn the device the worker is obliged to report defects or damage
device with an explanation of how the damage occurred.

(6) The dispensing apparatus must be registered.

(7) The number of serviceable equipment must be at least 10% greater than
the number of staff required to check the concentration of methane and gaseous
pollutants in mine air in the most occupied inning.
Part of the second


Ventilation neplynujících non-coal mines
Section One



General Provisions
§ 116

Downshift

(1) Neplynující those mines where methane concentrations below the
no ovětrávaném mine workings where 0.1% and even after stopping ventilation for 24 hours
methane concentration reaches 1%, and the concentration of other gases || | 25% of the lower explosive limit. Fumes mine fires for inclusion
mine involved.

(2) The inclusion of the mine for the extraction of the reserve deposit and the mine, in which
are carried out exploration work, decide on the basis of measurements under paragraph 1
District Mining Authority, which currently controls the deadlines
measurement.

(3) possible occurrence of methane or gas must be tested in places and
intervals to be determined by the organization, but always where suspicion arises
their occurrence.

(4) Any findings that could affect the classification of the mine or its part
into the category of gassy mines, the organization must promptly notify
District Mining Authority. In the presence of gases other than methane
The Regional Mining Office determines that the provisions of the first part of the organization must comply
. For finding is considered as the expected occurrence of gas.

§ 117

Wind joints down to the surface


(1) Mine must have at least one main downcast and upcast one main
mining work.

(2) One of the main mine ventilation mine work can have mine

A) when otvírce down until the main junction and the main vtažného
výdušného the mine; This applies likewise when otvírce new floor

B) when performing only exploration or construction work, and not just on one floor
,

C) in providing or winding down (floor).

Ventilation these mines (floors) should be addressed in the project.

(3) upcast pit must be deepened in a timely manner so that their
bottom floor was just one floor higher than the initial floor of the same
windy area. Also downcast shaft must be deepened in time to
without serious reasons nedobývalo below the deepest vtažným floor.

(4) The provisions of paragraph 3 is satisfied even when the desired level is reached
floor pit blind (Sibik).

(5) Paragraphs 3 and 4 shall apply mutatis mutandis to the other main downcast and upcast
mines than the pit.

(6) If there is no other way ensured that the icing on the main downcast
Excavation will not threaten the safety and operation shall be downcast
winds heated to at least +2 degrees Celsius.
Open fire must not be used for direct heating vtažných winds.

§ 118

Ways ventilation

(1) Mine, except as provided in § 119 para. 2 must have a separate
mine ventilation system.

(2) mine must be ventilated artificially, and at a time when they are in a mine people
continuously. After stopping ventilation under § 125 must be timely ventilation
started before the preliminary inspection or before
occupying workplaces, unless preliminary examinations should take place.

(3) Mine works, apart from abandoned mines and excavated spaces
must be ventilated either průchodním air current or separate ventilation
if this ordinance does not allow any other way.

(4) Underground structures can be ventilated by natural ventilation
only in exceptional cases where a natural draft mine air
reliably ensure compliance with this decree.

§ 119

Relations with neighboring mines

(1) The workings of the merging neplynující mines must be built
close the dam or at least two air door opening in the opposite direction
.

(2) Involvement of several mines within the same organization to one větrního
system is possible with the consent of the District Mining Authority. Involvement down
different organizations into one větrního system is possible only with the consent
District Mining Authority.

(3) When a joint Větřní of several mines are appointed staff
bound to each other without delay communicate the changes and events that may affect
ventilation, especially the composition of mine air adjacent downward.
Planned changes must be discussed in advance.
Section Two


Mining winds and wind path

§ 120
The composition of mine air


(1) in mine workings, where the stay or can stay
personnel mine air must contain at least 20 volume% oxygen concentration
and the following gaseous pollutants ^ 16) must not exceed the following values ​​
:
carbon monoxide (CO) 0.003%
carbon dioxide (CO2) of 1.0%,

nitrogen oxides (nitrous gases) (NO + NO2) 0.00076%
hydrogen sulphide (H2S) 0.00072%.

(2) Work in the mine air with a concentration of carbon monoxide in
0.013% is possible provided that the average concentration of carbon monoxide
per eight-hour workday or a shorter
exceed the value specified in paragraph 1 and, after the entire work will be regularly
, the concentrations of carbon monoxide in the mine air
at intervals determined by the Head of the liquidation of the accident.

(3) Racing mine or the authorized officer may temporarily authorize
reduced oxygen concentration to 19% and increased concentration of carbon dioxide
up to 1.5%, but at the same time is bound to order
measures to eliminate this condition.

§ 121

Volumetric flow mine air

Volume flow mine air in mine workings, where
reside or resided workers must be such as to ensure compliance with the requirements of this ordinance
.

§ 122

Current velocity

(1) The current velocity must be at least


A) 0.15 ms-1 excavated in vertical mine workings,

B) 0.3 ms-1 in other workplaces.

(2) current velocity shall not be greater than

) 4 ms-1 in early development and preparatory workings workings of a
stopes,

B) 10 ms-1 in other mine workings with walking or regular
transport people

C) 15 ms-1 in other mines without walking a regular transport
people.

(3) In the mines, if not allow any transportation or walking
people, not current velocity is limited.
Section Three


Main and auxiliary fans

§ 123


Home fans
(1) The fan must be placed at the main větrního mine
work.

(2) The fan must have a backup drive and transfer the driving forces
if not installed backup main fan. For fans of the same type
organization may have only one backup drive and transfer the driving forces
if it ensures their timely transfer and involvement on the ground
potential needs.

(3) The fan must be equipped with devices to measure the pressure drop
.

(4) Before the main fan to permanent operation or when
substantial change its parameters must be verified
its operating characteristics.

(5) The operation of the main fan without a machinist is allowed, provided it meets the requirements of §
fan 219. Operational security system must have
energy source independent of the fan drive.

(6) Channel main fan must have a closing device and must be
accessible from the surface.

§ 124

Maintenance of the main fans and their accessories

(1) the operation of the main fan is obliged to inspect the designated
worker at least once a day.

(2) Backup main fan is obliged to inspect and check
designated officer at least once a month.

(3) The fan and its accessories must be thoroughly
checked at least once a year and, if necessary, cleaned and conserved
; u jam with a skip profiting, however, at least a half
year.

(4) for the repair of the main fan, or even a backup
fan organization is required to determine the necessary safety measures.

§ 125

Measures in stopping the main fan and fault ventilation

(1) Stop the main fan or change the way it works
is permitted only on the written order of a designated official.

(2) When you stop the main fan or when a severe failure in the ventilation
must follow the emergency plan.

(3) After resetting the main fan or removal
serious disturbances in the ventilation can be a workplace filled only after verifying that the ventilation
meets the requirements of this Decree.

§ 126


Canceled
§ 127


Auxiliary fan
(1) auxiliary fan can be used for that part of the mine where the
you can not otherwise meet the requirements of § 120, 121 and 122. The deployment
výpomocného fan and the conditions of its operation decides to race down
by calculating ventilation, and only to the extent necessary. When
stop výpomocného fan must follow the emergency plan
.

(2) Inclusion výpomocného fan in mine ventilation network, his removal from the
and change its technical parameters are considered to alter
ventilation.
Section Four


Distributing mine air

§ 128

Leadership mine air

Downcast winds must be routed to the appropriate floor or
deepest point and from there the shortest way to the mine ventilation porubům and dobývkám.

§ 129

Wind ways

(1) as wind paths can be used to viable mines and
mine ventilation holes with a diameter of 0,3 m or chimneys without lezního
department of transport equipment or if not used for the transport of spoil.
Caverns and other areas impassable mines can be used as
mine ventilation paths for výdušných winds if it does not reduce the volumetric flow
vtažných winds needed for ventilation.

(2) Cross-roads of ventilation shall be such as to allow
observe the speed limits and required volumetric flow rate of the mine air
terms of compliance with the specified composition of mine air.

(3) In a mine, which regularly transported when calculating

Light cross section of mine ventilation paths must cross section of the mine work subtract
cross conveyor equipment, or even cross-section of the stored material.

(4) In the viable paths of ventilation must be possible to transport materials.

§ 130

Individual
Wind department
(1) The Wind Individual departments and related downcast and upcast wind currents
may be mutually interconnected, just for essential purposes.

(2) Beginning and end of a separate ventilation section shall be given in
plan for opening, preparation and mining and indicated in Větřní scheme.

§ 131

Insulation wind currents

All unwanted connections (shorts) in the ventilation network must be isolated.

§ 132

Ventilation and longwall stopes

Poruby and dobývky must be ventilated průchodním air current, except those
longwall stopes and in which mining method is a method of ventilation
required.

§ 133

The Wind door

Wind doors must be self-closing.
Not remain unnecessarily opened. As soon as the need for them, they must be planted or
secured open. Where the door is opened endangering proper ventilation
must be built at least two of such mutual distance that
some of them they were always closed.

§ 134
Wind curtains


Instead of air doors can be used 2 wind curtains, but only when
where a leak impede distribution of mine air and where they can not be
built or properly maintained air door.

§ 135
Wind bridges


Wind bridges can be used only if it is not possible to resolve the leadership
mine air otherwise. Wind bridges must be tight and made of non-combustible material
.
Section Five

Auxiliary ventilation


§ 136

Ways ventilation neproražených workings

(1) Neproražené mine work must be ventilated separate ventilation ^ 28)
whenever it is determined to ensure the composition of mine air or when
distance from the face průchodního větrního stream reached 15 meters.

(2) Neproražená mines in which it is not possible for technological reasons
(using tunnel boring rigs, during the excavation of small-profile mining
works for chamber blasting etc.) To establish a separate ventilation, it is possible to
consent racing pit or a designated employee ventilate
compressed air.

(3) Secondary ventilation with dams, wind curtains or
Luten is permitted only temporarily as an emergency measure.

§ 137
Separate ventilation


(1) separate ventilation should not be at any point průchodního větrního
current consumed more than 70% volume flow mine air.

(2) Type separate ventilation, placement of fans and silencers
Bringing Luten průchodního větrního to stream their lengthening or shortening
, stringing, joining and sealing and method of disposal
exhaust dust must be given in the technological process.

(3) To be used other than metal ventilating pipes must be of a material that does not support
spread of fire.

(4) Sealing air pipe strength must meet the particular prescription. ^ 28)

(5) Separate ventilation must be continuous;
may temporarily be suspended on condition that the relevant mining work will be promptly identified
entry ban that will separate ventilation before or after inspection
cast work started on time and that the organization
implement appropriate safety measures to protect workers who could be at risk
gaseous pollutants from the mine ovětrávaného. Similarly, it is necessary
proceed in case of failure of a separate ventilation.

§ 138
Fans separate ventilation


The first fan separately ventilated mining work must be controlled from
průchodního větrního current.
Title six


Mine Ventilation outlets

§ 139

Ventilation mining businesses, chambers and warehouses

(1) depot (tie), mine locomotives, plant machinery with diesel engines
, establishment, stationary refrigeration equipment, electrical
stations, warehouses explosives-20) and the storage of flammable liquids and solid lubricants must
be ventilated continuously.

(2) in the chamber for charging the battery may be hydrogen concentration in the mine air
greater than 0.5% and must be ensured at least

Twelve-air changes per hour. If the chamber is ventilated
separate ventilation fan should be located outside the chamber and the charging operation
rectifier unit functionally coupled to fan operation.

(3) In storage of flammable liquids and solid lubricants and in the premises where the
handled these substances or gases must be provided at least quadruple
air changes per hour, and the concentration of gases in the mine air
may not exceed 25% of the lower explosive limit.

(4) In the premises with a stationary cooling equipment must be secured
volume flow mine air for at least 3 ms-1 per 100 kg
refrigerant compressor unit with the highest load. If upcast winds from the establishment
discharged directly into the overall výdušného větrního current
tenfold sufficient air changes per hour.

(5) chamber with an oil transformer or electrical equipment with
oil filling and storage of flammable liquids and solid lubricants must be
ventilation to upcast winds of them have already been used to ovětrávání
workplaces where is embossed or conquered.

(6) Other mining establishments, chambers and warehouses to a length of 15 m may not be ventilated
průchodním air current or separate ventilation, if
ovětrávání ensured their diffusion.

§ 140
Ventilation niches


Niche to a length of 3 meters with unsteady
refrigeration and other niches within 10 meters may not be ventilated průchodním
air current or separate ventilation, if their ovětrávání
ensure diffusion.
Section Seven


Ventilation temporarily vacant and abandoned mines

§ 141

Temporarily unoccupied mines

(1) temporarily unoccupied separately ventilated mines must continue
ventilated, except in cases specified in § 137.

(2) temporarily unoccupied mines unless they are viewed
supervisory authorities must be marked with a cross terephthalate or withheld
at a distance of 10 meters from průchodního větrního current.

§ 142
Abandoned mines


Abandoned mine must be tightly closed as soon as possible, except
excavated areas that are used as wind path.
Dikes must be recorded (§ 188) and controlled by the deadlines specified organizations.

Section eighth

Check ventilation and apparatus for measuring concentrations of gases and gaseous pollutants


§ 143

Map ventilation and wind diagram

(1) for the mine to be developed and completed map ventilation ^ 15) and
mine ventilation scheme.

(2) On the map ventilation must also be marked down mines adjacent
up to 100 meters away from the common border with details of their
ovětrávání and way possible closure, seizure or destruction.

(3) wind diagram must show

A) the method of interconnection of wind currents in ventilation network,

B) a separate mine ventilation department and designation of nodal points

C) the position of a longwall stopes,

D) flow directions and volume flows of mine air,

E) the location and types of facilities for the distribution and control of mine air
including dams,

F) the location of the main and assistants to fans stating their performance
and pressure.

(4) wind scheme must be replenished so as to reflect the actual state
ventilation.

§ 144

Guided trips of ventilation and ventilation equipment

(1) Main downcast and upcast mines must be inspected at least once every six
year.

(2) wind paths within a separate ventilation section
must be inspected every working day, including individual mine ventilation department
least once a week.

(3) Process inspections or inspections of ventilation holes and chimneys, which are not equipped
Leźnie department or transport facilities, determine
organization.

(4) During inspections of ventilation routes must be simultaneously controlled and
equipment for distribution and control of mine air.

§ 145

Checking the composition of mine air

(1) possible occurrence of gaseous pollutants (§ 120), especially oxides
monoxide and carbon dioxide in the mine air must be tested in places and
intervals to be determined by the organization, but always there arises
suspicion of their occurrence.

(2) The results of workplace inspections shall be communicated to the foreman.

§ 146


Measurement and sampling of the mine air

(1) Volumetric flow rate, temperature and relative humidity of mine air
must be measured at least once every three months

A) the main výdušných mines windy area,

B) in výdušných mine workings near the coal extraction and stopes,

C) mined separately ventilated mines,

D) in mine workings with the operation of diesel and electric locomotives
.

In these places must also be sampled mine air and
performed their technical analyzes on oxygen and carbon monoxide and dioxide
.

(2) current velocity Longwall, stopes and driven separately ventilated
workings must be measured at least once every three months.

(3) In areas where blasting work, and in places with traffic
diesel engines must be within the time designated organizations collected
mine air samples to determine the concentration of nitrous gases and carbon monoxide
. Mine air sampling must be randomly checked
the length specified waiting period after the blast.

(4) in the chamber for charging the batteries must be collected sample
mine atmosphere to detect concentrations of hydrogen, or other gases
least once every three months, at a time when we can assume their highest
concentration.

(5) Analysis mine air samples to check its gaseous components
other than those listed in paragraph 1. a) they can be replaced by measuring
Apparatus permitted under special regulation. ^ 29)

(6) Measurement of radioactive contaminants in the mine air is performed by
special regulations. ^ 16)

(7) Sampling mine air is performed using the Czech
technical standards. ^ 29a) To overcome the vacuum seal for wind and when
remote sampling mine air can only be used ejector pump suction
or suction balloon; prior to sampling should be carried
exhausting air from the sampling tube and sample, at least in
twice the internal volume of the tube and sample.

(8) The sampling of the mine air enclosure
records the mine air pressure in an enclosed space.

§ 147
Barometric Pressure Measurement


(1) On the surface, the mine output increased risk of gaseous pollutants from Starin
must be measured barometric pressure. The measured data must be recorded and
records kept for at least six months.

(2) About falling barometric pressure must be informed workers
before going down into the pit. A sudden or significant drop in barometric pressure
must be informed of all technicians and leaders at the mine in
during the shift.

(3) The organization shall identify the necessary precautions for
cases of sudden increase in the incidence of gaseous pollutants in
drop in barometric pressure.

§ 148

To buildup of gases and gaseous pollutants

(1) If it is found that the composition of the atmosphere in the mine workings, where
reside or resided workers does not match § 120 must be
workers from these workings brought out into the wind and the vtažných
mining works must be marked entry ban. To remove this
status must be determined in the contingency plan.

(2) Re-occupation of workplaces is permissible after checking that the ventilation
especially mine air composition, meets the requirements of this Order.

§ 149
Wind balance sheet


(1) The Wind balance sheet must be prepared for each mine at least once every three years
always a substantial change ventilation.

(2) The balance sheet of the Wind is a report containing

A) a description větrního system with the characteristics of mine ventilation network and distribution
mine air, information about major vtažných and výdušných workings
principal and assistants to fans (including unloading operating point)
windy area and their division into separate departments of ventilation,
amounts of mine air in different branches of mine ventilation network, a description of ventilation
separate departments (work stations, interconnection,
isolation.)

B) a total balance of mine ventilation supplemented by calculating the equivalent holes and
data on the suction surface

C) a description of ventilation losses and faults in calculating the coefficients use of mine
winds (total and Faces and dobývky)


D) assessment of the current state of ventilation with regard to layout and depression
resistance in ventilation network segments and evaluation of ventilation paths
excessive pressure loss, stability analysis, diagonal links and overall
divorce mining winds | ||
E) appreciation of gas and climatic conditions,

F) assessing separate ventilation

G) assess the condition of ventilating the mine in terms of outlook and requirements of this ordinance
or special regulations ^ 16)

H) measures to remedy the shortcomings of the current state of ventilation due to the outlook
mine ventilation, stating the deadline and responsible persons.

(3) Wind balance sheet must contain the following attachments:

A) map ventilation

B) wind diagram

C) depressing image mine

D) a table of indicators ventilation workplaces

E) Basic data sheet Wind,

F) technical data and assistants to the main fan.

(4) Wind balance sheet must be within 2 months after the measurement is made
District Mining Authority.

§ 150

Leader ventilation

At each mine must be designed ventilation chief and his deputy.

§ 151

Conditions for using instruments to measure the concentration of methane and gaseous pollutants


(1) device to measure the concentration of methane and gaseous pollutants must be
indicate the type and registration number.

(2) An employee dedicated to the measurement apparatus must be trained in its use and
examined. Examination must be repeated every two years.

(3) The instrument may be issued or transferred only workers who have been appointed by him
measure.

(4) The device must be tested prior to dispensing.
Worker is obliged to pick up the instrument personally verify its function. Faulty devices are
not pretend to be, or should be returned immediately. Workers are obliged
assigned devices to protect against damage and may not
open.

(5) When you turn the device the worker is obliged to report defects or damage
device with an explanation of how the damage occurred.

(6) The dispensing apparatus must be registered.

(7) The number of serviceable equipment must be at least 10% greater than
the number of staff required to check the concentration of methane and gaseous
pollutants in mine air in the most occupied inning.
PART FIVE


Protection against mines coal dust explosion
Part first



General Provisions
§ 152

Downshift

Coal mines are mines with potentially explosive coal dust. For
coal dust in terms of protection against the explosion of mines deemed
coal dust having a grain size up to 1 millimeter.

§ 153

Measures to prevent and coal dust penetration

(1) The mine must use appropriate and available technical means and
measures to minimize the formation of coal dust and its
penetration into other mine workings.

(2) the pit in which the skip device for transporting coal, may not be used as basic
.

(3) As used in mines, except for wells, reservoirs, coal extraction
stopes must be regularly removed coal dust, even though
lost for his ability to stir up moisture. Deadlines for removing coal dust
organization determines the intensity of dust formation.

(4) The mines used to walking and transport must be routinely removed
fallen coal.
Part of the second

Disposal of coal dust


§ 154

Dusting inert dust

(1) the use of mines, except for pits, chimneys, wells, reservoirs, coal extraction
stopes must be around the perimeter and along
inert dusting powder, if not used in any other manner permitted disposal.
^ 30)

(2) Dusting must be such that the content of flammable substances in the mixture
coal dust inert and does not exceed 20%. In mines where the air current
allowed elevated methane concentrations over 1% must
dusting so that the content of flammable substances in a mixture of inert and coal dust
exceed 15%. Dusting must be restored immediately if
powder mixture according to the analysis of the sample mixture containing a larger proportion of flammable substances
than specified or finding that the poprášených locations
settled visible continuous layer of coal dust.

(3) If dusting workings can not keep the content of flammable substances

Mixed in values ​​referred to in paragraph 2 shall be coal dust
effectively disposed of in another way. If you can not not so much to achieve effective
coal dust disposal, must be appropriate technical means
prevent its penetration into other mine workings. These areas should be
from other workings isolated protivýbuchovými closures.

(4) The designated sites, which are still a large contact area so wet that
dust settled on them not to stir up and place without coal dust may not be
dusting.

(5) Employees are obliged to use a dusting
anti-dust respirators. Dusting no one should be physically threatened.

§ 155
Check dusting


(1) A mixture of inert and coal dust in mines
must be regularly tested for flammable materials so that it can be restored in time
dusting. Locations and dates for sampling dust mixtures
organization determines the intensity of deposition of coal dust.
This is to take into account also the location of the electrical equipment and the fact that the samples were not affected
water used in spraying etc. Samples must be taken at least


A) in a long Excavation near longwall or dobývky in section 50
meters upcast side of one sample per month and in the stretch from 50 to 200 meters
upcast side of one sample per two months, || |
B) at a location with greater dust source (at the transfer point, container etc.).
In section to 50 m downstream of the mine air, one sample per month,

C) in other long mining works, other than those listed in § 154
paragraph. 4, every 300 meters, one sample per 3 months. If a long mining
work less than 300 meters must also be taken in it, one sample per
3 months

D) in the places listed in subparagraphs a) to c), for which approval is issued
racing down the increase in methane concentration according to § 83 paragraph. 5
one sample every 14 days.

(2) Sampling inert dust or a mixture of inert and coal dust
and their analysis must be carried out under a special regulation. ^ 31)

§ 156
Stocks inert dust


(1) The organization shall have a supply of inert dust
intended for dusting and dust explosion closures at least one
week.

(2) an inert powder to be deposited on the surface in a dry sealed
spaces. The mine must be stored in suitable dry areas in the vicinity of
use. Place and amount of stored inert dust
designate organizations.

§ 157

Features inert dust

(1) A dusting of mines and for construction of explosion
cap can be used limestone dust, which must be
free silica in the amount of over 3% and other fibroplastické
or toxic substances and that retain even below rozviřitelnost and
ability to keep for a longer time in suspension.

(2) Other inert powders can be used only with the consent of the Czech Mining Office
.

(3) organization shall be provided for each consignment check whether supplied
inert dusts conforming to the approved species. Each consignment is obliged to request certification
manufacturer of quality dust.

§ 158

Wetting water and other ways of disposing of coal dust

(1) Neutralization coal dust wetting water, if necessary with the addition of a wetting agent
permitted where this method, particularly in terms
hygrothermal conditions, is effective.
For the disposal of coal dust by wetting only used water from the mine fire
tap water. ^ 32)

(2) Settled coal dust must be wetted perimeter and along the entire length
used workings, except pits, funnels, wells, reservoirs,
longwall and stopes, and to the extent that it can not cause its
turbulence. The organization shall identify periods of wetting of coal dust in the various
mines.

(3) When wetting must take care not to wet with electrical equipment.
Suitable measures must be provided to prevent electric shock
.

(4) Disposal of coal dust, calcium chloride is permitted only in dry
mines. When spread on electrical equipment must be protected by covering
.

(5) Other ways of disposing of coal dust
authorizes the Czech Mining Office.

§ 159

Method, control and responsibility for disposal of coal dust


(1) The manner of disposal of coal dust decides to race down.

(2) During inspections of workplaces, supervisory authorities and other technicians
also obliged to monitor the disposal of coal dust.

(3) organization shall identify personnel responsible for disposal of coal dust
and allocate responsibility among leaders and workers destined for disposal
coal dust.

(4) Workers must be defined sections of the mine workings so that
disposal of coal dust can perform a specific degree.
A third part


Protection against the transmission of the explosion of coal dust

§ 160
Types of explosion barriers


To protect against the transmission of coal dust explosion in a mine explosion puts
closures dust or water. Species used
explosion barriers designate organizations.

§ 161


Canceled
§ 162


Canceled
§ 163

Deployment explosion barriers

(1) explosion barriers must be built to protect

A) major vtažných and výdušných workings opening out on the surface Sibik
coal and containers, including their accessories (hinting, walkways,
filling stations. Etc) against other mining works, unless they are protected
Barrier door. Closures must be placed at a distance of 50
up to 200 meters from the property, which protects

B) a separate ventilation section at the downcast and upcast side.
Closures must be placed inside a separate ventilation section so as not
distance greater than 50 meters from the beginning and from the end. If you can not
explosion caps placed inside a separate ventilation section,
must be specified distance placed on all access roads to
him

C) links between separate departments Větřní if these connections are not equipped
Barrier door

D) mined otvírkového, preparatory or surround the mine.
Other barriers must be built in mined separately ventilated mining
work.

(2) Within a separate ventilation section, which is open stope
dobývka or bored or mine work must be explosion closures
built along the entire length of workings, which are kept downcast and upcast
winds these workplaces. In longwall or may not be dobývce explosion
closures built.

(3) explosion barriers must be built in mine workings in
which transports coal, even when they are in a mine
built dikes door [paragraph 1 point. a) and c)].

(4) neplynujícím below may not be isolated otvírkového mine
works exclusively mined in stone, built explosion closures.

(5) explosion closures may not be built in the neplynujících
coal and lignite mines in which it is shown that coal and lignite dust
no explosion hazard. Explosion verification must be performed each time
nafárání new seams and repeated changes in such
seam quality and local conditions that could adversely affect
Dust explosion, but at least every three years.

(6) explosion closures are placed in horizontal and inclined
mines.

§ 164

Distance for the location of explosion barriers

(1) Explosion-centered closures are built, if possible in direct
section of the mine of the same section. If the mine work expands
Explosion enclosure must not be placed closer than 20 meters from the place
extension.

(2) The distance between the edge of explosion barriers centered,
built according to the requirements of § 163 paragraph. 1 point. c) and d) and § 163 paragraph.
2 and 3, shall not be greater than 200 meters.

(3) Last dam explosion closures centered
must be placed at a distance of 50-200 meters from the face mined the mine stope
or mouth or dobývky, except as provided in paragraph 8.

(4) If the explosion lockup concentrated and isolated
object Cross branch, fork or curve, which changes the direction of
more than 90 degrees, the distance from the explosion closures
Cross branch, fork or bend the smallest, but most
50 meters.

(5) The last group of troughs or bags explosion split
closures must be mined from the mine face far more than 100 meters from

Mouth longwall or dobývky than 50 meters.

(6) If between two groups of troughs or bags explosion
closures cross sectional, branch, fork or curve, which varies
direction of more than 90 degrees may be in justified cases the distance || | between these groups of troughs or bags larger than 30 m.
Number of troughs or bags must be increased so as to comply with the condition
least 1 liter of water per 1 cubic meter volume of the mine
between groups of troughs or bags.

(7) When conquering the chamber, and soutirage zátinkování is for dobývku
considered mining (mining) basis, or at a diagonal led
broad front group bases. The length of the base or bases
including their connecting corridors shall be not more than 300 meters.
Explosion closures on the access corridors should be no more than 50
meters from crosses of these corridors with mining base.
Mintage longwall corridors within the meaning of the provisions considered part
conquest.

(8) If the distance between two work digging or mining
the common corridor is more than 50 meters between them must be placed
group of troughs or bags, the minimum quantity of 320 liters of water. This group
troughs must be replaced explosion roadblock once
distance between the workplace is more than 150 meters.

§ 165

Records, inspection and maintenance of explosion barriers

(1) explosion barriers must be numbered and marked on the map
ventilation. They must be guided by the evidence
technical data required in paragraphs 2 and 3

(2) Explosion-centered enclosure must be placarded on
which indicates the number of closures, the section of the mine work in square meters
, the total amount of inert dust or water in an enclosure,
number of dams and troughs or bags, the date of the last periodic inspection and signature
controlling. The table must be placed at the edge
closures.

(3) Explosion divided enclosure must be identified on
which indicates the number of closures, the section of the mine work in square meters
, the number of troughs or bags, or the amount of water in one group of troughs or
bags, the date of the last periodic inspection and signature
controlling. Sheets are placed on both ends of the closures. In the event that divided
seal merges into another mine, they must be marked
new tables. This also applies when changing cross mine according
which varies the amount of water in a group of troughs or bags.

(4) explosion barriers must be maintained in good condition. In aquatic
cap must be allowed replenishment of the
mine fire water supply. When filling water explosion barriers apply mutatis mutandis §
158, paragraph. 3rd

(5) During inspections of workplaces, supervisory authorities and other technicians
also required to check the status of explosion barriers, with water seal
especially for water. In addition, the organization must determine
person responsible for the periodic inspection of explosion barriers and deadlines
carrying out these checks, but they must not be longer than a month.
PART SIX

Fire protection

Part first


General provisions on fire protection

§ 166

Basic provisions for fire protection

The fire protection organization is required to fulfill the obligations specified in this Decree
and special regulations. ^ 35)

§ 167

Places with increased fire risk

(1) All places underground, as well as building pits, shafts and inclined slopes,
degassing stations, the main building and hoist tower fans for the purposes of this Decree
considered places with increased fire hazard.
The gassy coal mines and for those places considered too
premises within 20 meters from the main fan and the diffuser from the mine
opens out onto the surface.

(2) In locations with increased fire danger is forbidden to smoke and to wear
for smoking and any objects which may cause a fire
. The organization is obliged to monitor compliance with this ban
. For surface objects referred to in paragraph 1 shall be marked with the ban
tables.

(3) places with increased fire risk must be periodically removed
unnecessary flammable substances.
Part of the second



Precautions against mine fires

§ 168

The use of open flames in areas with increased fire risk

(1) The use of open fires in areas with increased fire risk
permitted only where strictly necessary and only where
risk of fire or explosion danger, on the written order of the organization.
Pattern written order issued central authority having jurisdiction over the organization
belongs.

(2) The written statement referred to in paragraph 1 shall be determined by workplace
place, type and scope of work and equipment with which it will
work, and the time of their use and precautions, mainly | || removal of flammable substances or to prevent sparking, check
air composition, emergency fire-fighting equipment and conducting inspections at vulnerable points
at work and after its completion. It must be specifically designed
worker performing constant supervision, worker
serving designated facilities and staff supervising the workplace and its surroundings in
work breaks and after work with open flames.
Issued orders must be filed.

(3) Before working with an open flame is a staff member designated to perform
constant supervision shall check the fulfillment of security
measures identified in the warrant for the use of open fires.

(4) below may be used only kit for welding and flame cutting
oxygen hose equipped with a fuse-35a) located at a distance of 1 m
farthest from the handle of the torch, if not a similar safety device fitted directly
torch handle.

(5) stopping work is required to supervise the workplace and its surroundings
least one dedicated and knowledgeable staff. After finishing work, the worker must
this tour of the site and its surroundings
convince yourself that nowhere is no danger of fire. Tours
workplace and its surroundings after work with open flame is required
designated officer to perform for at least 8 hours,
continuously or at intervals of no longer than one hour. Way, or even
inspection intervals determined by the degree of hazard racing down
or by designated personnel. Until the last re-inspection should place
use of open fires remain for extinguishing agents.
The results of inspections must be recorded in a written statement or reported to
control room or other designated location.

(6) The use of open fire might be permitted only in places where
under normal conditions of ventilation of methane concentration when working with an open flame
not exceed 0.5%.

(7) For underground facility specially built for the use of open flames
organization may issue a standing order to open fire.
Establishments must be equipped according to special regulations ^ 10) but always
must meet the requirement of non-flammable reinforcement and continuous control
concentration of carbon monoxide in the upcast air current from
facility to gassy mines and methane concentration in vtažných
winds fed to the plant. Upcast air stream from this
establishment must not be used to ovětrávání coalface dobývky not mined
mine work.

§ 169

Material means of fire protection

(1) below may be distributed only extinguishing systems and fire
device ^ 29) which do not endanger the health and safety of workers.

(2) Benefits for fire protection (fire alarm, fire
equipment, fire extinguishers, etc.) Must remain alert and
least once every six months reviewed. They must not be used for other purposes than to
fire fighting and practicing this activity. Used
funds must be immediately ready for reuse or
replaced. Mine fire water can be used for supplying
technological water and for the protection of coal mine explosion
dust.

(3) Fire-fighting equipment and fire extinguishers must be protected against freezing
.

§ 170

Deployment and emergency fire-fighting equipment

(1) establishments or entering into them, each stationary
machinery equipment in addition to air powered and in other places with
risk of fire must be placed
suitable extinguishing agents. In places průchodním ventilated air current must be

Extinguishers placed on the side of the downcast.

(2) In mines with belt conveyors must be
extinguishing agents stationed every 50 meters. When used sand or stone dust,
must be in portable containers in an amount less than 30 kg at one
station.

(3) At one of the stations can be stored only one kind
fire extinguishers. If you have to use more types of fire extinguishers must be stored separately
at least 5 meters apart.

(4) Fire extinguisher must be sealed and have the type designation
with an instruction manual and an audit trail.

§ 171

Fire warehouses

(1) on the surface of the mine, where the mining activity is carried out, must be
storage needed supplies of fire-fighting equipment, including fire equipment, etc.
. Surface warehouse fire ^ 36) for the use of these funds
underground.

(2) For storing needed supplies fire-fighting equipment, including fire arms, etc.
. Must be in the mine, which is done mining, underground fire
warehouses. Their location, design, equipment and method of storage will determine
racing down.

§ 172

Mine fire water

(1) coal mine must be established by mine fire water
special regulation. ^ 32) Mining fire water must be spelled out in all
used mines and explosives depots, with the exception of pits and stacks
without lezního department, boreholes, workings, stopes and other outlets.

(2) In other mines with mining activities should be ensured
abstraction of water in quantities of 400 L · min-1 during the hydraulic pressure of the flow behind
0.25 MPa in nárazištích separate floors at the mouth of jam , galleries and
inclined slopes, warehouses and explosives at places designated organizations around
agreement with Ranger Mines rescue station.

(3) Mine fire water must be constantly under repair in addition to the necessary
water pressure.

(4) Mining fire water must be readily connectable to a discharge pipe
main pumping station.

§ 173

Inspections and repairs mine fire water

(1) In each shift must be checked whether the mine fire
water supply is under pressure.

(2) State mining pipeline fire water hydrants including
is obliged to check the designated officer at least once a month.

(3) Volume flow of water and hydraulic overpressure for water flow must be
measured at least once every six months. Measurements must be carried out in each separate
Větřní department and the associated air current, in the most unfavorable place
mine fire water supply in terms
hydraulic resistance.

(4) During the repair Mining fire water is the one who has to carry out repair
obliged to report the beginning, anticipated duration and termination
work to the control room or other designated location.
Message must be recorded.

§ 174
Fire tank


(1) Mining coal mine fire water must be connected to the fire
tank with a constant supply of water. In other mines may be mine fire
water supply connected to another source of water, which yields its secure
fixed amount of water. The water supply including any minimum
tributary or operational replenishment must be such that water abstraction
at yields considered emergency plan was possible for at least 8 hours
. Appropriate technical solution must be allowed to water abstraction even when
frozen surface reservoirs or streams.

(2) tank fire must be to ensure a constant and necessary
abundant source of water.

§ 175

Fire ensure the opening of workings

(1) Reinforcement and gear shafts, tunnels and inclined slopes opening out on the surface must be
except průvodnic inflammable. A similar requirement applies to wells and chimneys
if the initial mine works, and for blind holes and Sibik.

(2) Reinforcement and equipment nárazišť and other outlets into the workings
initial workings must be a distance of at least 10 meters from the point of penetration
inflammable.

(3) Reinforcement and equipment opening of mines and their nárazišť must be
least annually cleaned of flammable substances.

(4) Usti initial workings if they are not closed tight of the ceiling must be fitted easily
friendly steel fire hatches or doors
of nonflammable material. This requirement also applies to

Emergency passages and channels warming. Other openings in these mining
works (for pipes, cables, etc.) Shall be non-sealed.
Control elements of the shutoff valves or valves on pipes must be positioned below
fire hatches or other closure for the opening
workings. On plynujícím below must be fire hatches in such
depth to their conclusion there in case of an explosion violation
mouth of the pit; in addition it must be ensured and the opportunity to increase their resistance
explosion. The provisions of this paragraph shall not apply to
underground work.

(5) Fire hatches and doors must be kept in such condition that
be quickly and tightly.

(6) Fire hatches and doors shall check the designated officer
least once every six months. In doing so, it is also required to verify
time required for their conclusion.

(7) Blind pit Sibik must vyúsťovat branching into mine workings so
to these mines could be build as needed and 2
closing the dam eventually pass. The distance between the tangential mining
work and the main gallery or other mining work at the site of the dam closing
must be at least 8 meters.

§ 176

Fire tanks ensure coal mine

(1) Reinforcement tanks and equipment in coal mine must be non-flammable.

(2) On the gridiron and the discharge opening of the container must be turning
mine fire water to the hydrant.

§ 177

Fire securing objects on estuaries initial workings

(1) Buildings pits, shafts and inclined slopes, buildings and mining main fans
towers must be of non-combustible material and must be protected against the effects of lightning
.

(2) Objects referred to in paragraph 1 shall be non-isolated from all
adjacent buildings, which are non-flammable material.

(3) In buildings, pits, shafts and inclined slopes or in their immediate vicinity
not be stored flammable materials. For storage
does not store such quantities of these materials, which will be during the next shift
transported underground.

(4) Warehouses combustible materials should not be closer than 60 meters from the mouth of the mine vtažného
.

(5) Oil rig must be at least once a year, deprived of deposition and lubricants
settled combustible dust.

(6) Mining fire water must also be connected to the engine hoist
machines located in the mining tower. This part of the mine fire water
not be permanently under pressure if the water supply to ensure connectivity
sufficiently powerful pumps in the emergency room or fire
tank.

§ 178

Safe passage to vtažných workings opening out onto the surface

(1) In the event that the downcast mine work ends on the surface will be closed
fire hatches or doors must be established emergency passage of this
the mine to the surface, unless another mine work, which would could fulfill this function
.

(2) Emergency must pass into the mine opens out onto the surface vyúsťovat
so that it is accessible from under the covers fire or fire
door. On the surface must vyúsťovat into separate buildings of non-combustible material
or at least 8 meters from the buildings of nonflammable material or
least 12 meters from other buildings.

(3) Safe passage must be non-flammable reinforcement and ensure
safe passage of workers and the necessary ventilation to the mine.
Necessary amount mine air will determine the organization.

(4) Where the emergency passage for supplying heated air into the mine workings
opening out on the surface must be taken to prevent
to excessive temperatures on workers and their burns
heating device .

(5) Safe passage is obliged to check the designated officer
least once every six months.

§ 179

Closure device of the suction port of the main fan

(1) Closing device suction port of the main fan
must be maintained in such a condition that could be quickly and tightly.

(2) Shut-off device is required to check appointed officer
least once every six months.

§ 180
Smoke doors


(1) At the main vtažného the mine opens out onto the surface, where besides
průvodnic flammable reinforced or fitted, must be all mine
works that open out into it, built as smoke doors located

Close to this mining work.

(2) Smoke doors must be given after the conclusion easily opened from both sides.
Within easy reach of smoke doors shall be no obstacle that would hinder their
rapid conclusion.

(3) Close smoke doors must contain a sufficient amount
immediately usable non-combustible material to seal them.

(4) Smoke doors and sealing material is required to check the designated
worker at least once every six months.

§ 181

Requirements fireproof reinforcement

(1) If it is determined using non-flammable reinforcement must be made of non-flammable material
all support elements, in addition to braces and inserts
supple tvárnicové reinforcement.

(2) Vacant space for reinforcements in areas where it is intended
incombustible reinforcement, must be filled with non-combustible material or
coal that is not susceptible to spontaneous combustion or coal in packaging
restricting access of air. Coal can not fill empty spaces for reinforcements
initial workings.

(3) Wooden insert floppy tvárnicové supports must be soaked so that they are not
highly flammable and must build
reinforcement to form a continuous strip. The gaps between adjacent pads must be at least 0.3 meters
.

§ 182

Places Flame reinforcement

(1) In addition to the workings listed in § 168 paragraph. 6, § 175, 176, 178 and § 224, paragraph
. 10 must be fireproof reinforcement reinforced mines

A) coal mine in the entire length if they are routed downcast
winds downhill, in a brown coal and lignite mine workings longer just 75 meters

B) coal mine in the entire length if they are routed upcast
winds downhill and have coal transported by belt conveyors in lignite and lignite
just below the mine workings extended 75 meters

C) 50 meters from the place where the air stream unites or divides
into two or more separate department of ventilation,

D) 10 meters from the preparatory fire barriers on both sides, except
preparatory fire barriers on the working face at the base of the chamber
conquest

E) 5 meters from the edge of the drive or return roller of the belt and
scraper conveyor, which remain in place without transferring more than two months
except drives longwall mining base when the chamber.

(2) Mine works with the transport belt conveyors, except mine workings
referred to in paragraph 1. b) must have

A) non-flammable reinforcement or

B) of flame retardant reinforcements made fire safe zone
75 meters long and spaced at most 200 meters, the first zone must be at the beginning of this
mine work, or

C) racing pit designed such measures to prevent the spread of fire burning
reinforcement in these mines.

(3) underground facility, storage of flammable liquids and solid lubricants, including emergency
storage of flammable liquids and solid lubricants and all
access to them within 10 meters must have non-flammable reinforcement.

(4) Non-flammable reinforcement may be in the pipeline (mining) bases (
§ 164 par. 7), and in the mines and in underground premises that
is possible according to § 44 para. 3 without leave reinforcement.

§ 183
Conveyors


(1) Transporters must be placed and operated so as not to cause friction
fire.

(2) Substructure conveyor belt must be of non-combustible material
.

(3) Used conveyors must be examined in each half inning,
after stopping the conveyor belt at the end of the shift and after transport
in the inning. During the tour must be verified that there is no risk of fire
. Result of the inspection, specifying viewed
conveyors must be reported to the control room or other designated location.

(4) Belt conveyors, which are equipped with devices for signaling
elevated temperatures drive and return stations and discharging must be stopped after
conveyor at the end of the shift and after the shift in traffic for 2 hours
guarded.

(5) Sandhills belt conveyors must be made of non-combustible material
. Transitions over conveyors must be made so that
not cause a fire by friction.

§ 184

Gas storage of flammable liquids and solid lubricants and handling

(1) In the basement can be stored in addition to diesel ^ 37) only

Flammable liquid and solid lubricant with a flashpoint of more than 55 degrees Celsius
.

(2) Manipulate gases, flammable liquids and solid lubricants can only
appointed staff who have been instructed in the proper and safe handling
scheduled substances.

(3) gases, flammable liquids and solid lubricants can be transported and kept in place
consumption only in packaging that meets the requirements
special regulations ^ 37) and only in the total amount corresponding to the consumption of one
shifts. Metal pressure vessels for transport of gas must not
left unattended, if not an appropriate way to prevent their misuse.

(4) spills or pumping flammable liquids can only
locations and under conditions determined by the organization. In doing so, they must comply with the safety, hygiene and fire
requirements.

(5) tanks and containers of flammable liquids and solid lubricants must, except
pouring, decanting or subscribe weight permanently closed, and even if they are empty
. Corks facing up. When transporting tanks must be
packaging and properly fastened and a distance of 20 m from the transport route is not
carry out work with an open flame.

(6) Flammable liquid should not be exhausted from the closed container
pressure of compressed air or gas, or pour from the transport container into the tank
without using a funnel.

(7) Places with accidentally spilled or leaked flammable liquid or
contaminated lubricants must be cleaned up immediately.
For spilled flammable liquids must be at designated locations promptly supply
absorbent material.

(8) The cleaning agent must be closed to non-flammable
impermeable containers at least once a week taken out from underground.

(9) Mine cars and trucks, which are transported containers with gases or flammable liquids
must be identified and included in the kit
always at its end; into transport containers or podstavník must be stuffed
manually.

(10) If the transportation of flammable liquids in mine or place of storage or consumption
provided by pipeline, the organization is required for this mode of transport
issue operating documents to address, inter alia
fire protection and protection against leakage of flammable liquids.

(11) and dispatches gases, flammable liquids and solid lubricants must be in warehouse
registered.

(12) Tray flammable liquids, which is a part or accessory
stationary machinery must be protected against falling rocks
or other mechanical damage. Must have an emergency sump, which is able to accommodate the largest
used refill container increased by 15%.

(13) Inspection and cleaning the inside of tanks flammable substance can
performed to verify that the concentration of flammable gas is under 50%
lower limit of explosiveness and ensures that this concentration will not
during work exceeded. When the work is necessary to use breathing apparatus
.

(14) Repair of tanks or equipment in which could result in ignition or explosion
flammable gases can not be carried out underground.

§ 184a

Requirements stores of gases, flammable liquids and solid lubricants

(1) Stock flammable liquids and solid lubricants can be constructed only by
project. The floor must be impermeable and chemically resistant
of stored media, sloped to the emergency reservoir, whose volume corresponds
volume of the largest tank, or the entire volume of interconnected tanks and
covered by a grate.

(2) Under drain valves of tanks to be trough or other restraint devices
.

(3) Lighting warehouse can only be ensured by fixed lights in explosion-proof design
clearly marked switch located on the front stock
downcast side.

(4) Wind power ovětrávající set can not be used to ovětrávání
workplaces where coins or conquered.

(5) transport and handling can only be used tanks and containers of tight,
solid and non-combustible material marked a significant sign of the kind
degree of flammability and the amount of liquid or solid lubricant.
May be used only to indicate the nature of the substance.

(6) Any kind of used liquid and solid lubricant is stored in containers
separately in compliance with the handling gap of at least 0.6 m.

(7) tanks, containers, racks and other warehouse equipment must be
combustible material and grounded against the adverse effects of electric

Energy; It does not apply to track undercarriages placed on the tracks.

(8) Vents on the premises of warehouses are provided with lockable flaps
tightly controlled automatically or from the outside.
Fire protection is provided by at least four pieces
vzduchopěnových or similar hand-held fire extinguishers, 150 kg of sand or extinguishing powder
placed in a crate and a shovel.

(9) In the warehouse, or on the front door to it is necessary to place


A) a list of persons authorized to handle substances in the warehouse

B) Operating Rules warehouse

C) warning signs to ban entry of unauthorized persons and the prohibition
work with open fire,

D) the registers and dispatches substances stored,

E) a sufficient number of vessels carrying flammable liquids.

§ 184b

Standby storage of flammable liquids and solid lubricants

(1) Standby storage of flammable liquids and solid lubricants establishing a project approved by
racing down. Taking standby warehouse
allows racing down.

(2) In a separate Větřní department could be established only one
emergency storage of flammable liquids and solid lubricants. Entry into
standby storage of flammable liquids and solid lubricants may be just a
průchodního větrního current. For stand-stock
flammable liquids and solid lubricants in unaffected upcast air current to be carried
constant monitoring of the carbon monoxide concentration continuously
analyzer.

(3) Fire Protection standby storage of flammable liquids and solid lubricants provides
least two vzduchopěnovými or similar hand-held fire extinguishers and
least 50 kg of sand or extinguishing powder
placed in a crate with a shovel. Extinguishing means are positioned at the entrance to the warehouse
. In standby storage of flammable liquids and solid lubricants
must also be at least 20 kg absorbent material intended for remediation of releases
stored materials.

(4) In the standby storage of flammable liquids and solid lubricants may be
retain a maximum of 800 liters of flammable liquids and 175 kg of solid lubricants.

(5) For the storage of flammable liquids used closed cell
tank is lockable to prevent misuse. For mobile tank is regarded
container with double jacket, or barrel embedded in the metal container to store
or modified mining vehicle; free volume metal container and mining
car must be at least 15% greater than the volume of flammable liquids stored
.

(6) In the standby storage of flammable liquids and solid lubricants and
10 meters away from him shall be placed electrical equipment and associated cables
, with the exception of telecommunications cables, communication
equipment and lighting and their controls.

(7) For continuous analyzer under paragraph 2 shall also apply the requirements of § 109a paragraph
. 4, 5 and 6. For the storage of flammable liquids in standby
storage of flammable liquids and solid lubricants also apply the requirements of § 184a || | paragraph. 2, 5 and 7; for handling flammable liquids and solid lubricants
also apply the provisions of § 184 paragraph. 2-8 and § 184a paragraph. 9th

§ 185

Plastics and hydraulic circuits

(1) Plastics, conveyor belting, including belts
shall not increase the risk of fire and to encourage its spread.
Before use, it must be approved by fire from a technical perspective.

(2) Hydraulic circuits must be tight. Their design must be
such that the potential of leakage could occur and spread
fire or explosion. If the hydraulic circuit used
flammable liquid, the organization must identify measures to ensure fire safety and security
workers.

§ 186


Canceled
§ 187
Auto-ignition


(1) Coal seams are divided into seams prone to spontaneous combustion and coal seams without
susceptibility to spontaneous combustion. Prior to the commencement of mining must be verified
prone to spontaneous combustion of the coal seam. According to the results of the verification ranks
District Mining Authority seam in the respective category.

(2) below with the appearance of seams prone to spontaneous combustion must be created conditions for rendering
mine air with nitrogen.

(3) organization ensures consistency and management of spontaneous combustion prevention
mines issuing guidelines (working rules), which provides in particular
principles for drawing up a project for prevention of spontaneous combustion management

Workings in seams prone to spontaneous combustion, the method of determining the extent
risk of spontaneous combustion of coal in the seam and necessary measures.

(4) Project to prevent spontaneous combustion of coal and its changes are approved racing
mine. The measures set out therein are part of the technological process
for conducting mining works.

(5) When conducting mining works in seams prone to spontaneous combustion must be


A) prevent delays in the mine air spaces through caverns, old grass and
pillar between mine works by immediately sealing the cave, especially in the initial breakthrough
place during the conquest of longwall in longwall corridors in
following the procedure and coalface at the final location coalface, and also with regard to
spatial and temporal leadership workings,

B) promptly concluded mined areas and completed longwall mining
work that leads to them,

C) establish and implement measures to reduce the gradients of ventilation, on the basis of an analysis
compressed image windy area,

D) determined by the smallest daily progress longwall with respect to the anticipated
incubation time and the remedies for stopping or slowing the progression
coalface

E) create conditions to limit heat accumulation

F) immediately filled the space behind the reinforcement of mines,

G) prevention of endogenous fires
appropriate technical means, in particular by injection, proplavováním Starin, building flood
cuffs or inerting,

H) those chosen mining method and in longwall and such reinforcement that
loss of coal in the cave are minimized. The mapping documentation
operated longwall must indicate the place and the thickness of the layer of coal
materials left in Zavala.

(6) for the early detection of spontaneous combustion process of the organization at the appropriate locations
identifies and evaluates the evolution of carbon monoxide.

(7) The seam is prone to spontaneous combustion, it is possible to conquer the field only when
conquering a full elementary school, or if the overburden to five times
seam thickness is unclean or smelt nevyrubaná seam. At the contact
mined area with vtažným and výdušným mining work to establish
of filling strips or ribs prevent delay mine air vyrubanými
spaces. ".

§ 188

Notebooks

(1) In the book dikes must be recorded preparatory fire dams, dikes
objects and wind caps. Evidence must contain the information
location, type and thickness of dams and embedded devices (pipes | || covers etc.).

(2) the book of mine fires must be recorded data mining
fires and the manner of their disposal and attached a copy of the relevant parts
basic mine maps, profiles, cross sections etc. .



third part Coping mine fires

§ 189

policy fighting mine fires

(1) immediately after finding the mine fire workers must be removed from the endangered
workings mine fire or fumes.
Here, it must consider the risk of tipping the mine air and possible explosion.
If there is danger of explosion, must be removed all staff | || might be at risk of explosion, and that of all the coal mines in the range
least separate ventilation section. Do endangered
workings must be designed to prevent unauthorized access. The entry of workers into these
workings may be authorized once the danger has passed.

(2) Together with the fulfillment of the obligations under paragraph 1 shall be promptly
begun preparations to control the mine fire. In control must
proceed so that the fire was extinguished as soon as possible.

(3) If possible, it must be mine fires fought by direct intervention.

(4) Inaccessible fire in the mine cave-in is possible to climb even
effective damping provided that there is no apparent danger of explosion or dangerous levels of penetration
fire products to the workplace. For
damping is considered especially enlarging the cave as quickly as possible and
continuous process coalface, inerting is mined area or
establishment of the mined area suitable fill.

(5) to control the mine fire surround closing must proceed
time, unless it can be overcome by direct action or unless
effectively damped.

(6) Where dampened inaccessible mine fire must be determined by way
guarding the stope and preparatory measures for a rapid conclusion of endangered

Space (preparatory fire dams, gouges, quantity and place of storage
material needed etc.).

(7) During the fight mine fire by direct action or to its effective
damping must be made simultaneously measure the spatial closure
fire.

(8) In all fighting mine fires even when working on
prevent the adverse effects of mine fires must be regularly checked
composition of mine air in areas critical to assessing
risk of explosion and ensure protection of life and health
workers. Interval and ways to control the composition of the mine air will determine
leading the liquidation of the accident, unless stipulated otherwise. When
checks must be detected concentration of oxygen, oxides
monoxide and carbon dioxide, methane, hydrogen and optionally higher hydrocarbons.
Composition of mine air checks must be carried out as quickly as possible and the outcome
immediately communicated to the crisis manager. On
gassy coal mines and explosiveness to be mine air
investigated explosimeters composition analysis or evaluation of mining
air detected by chromatography.

§ 190

Spatial closing the mine fire

(1) Method surround closing the mine fire
must conform to local conditions and ensuring the fastest and safest climbing.

(2) Mining fire must be spatially closed in accordance with the regulations intervention
^ 38) issued by the Mines Rescue Station chief.

(3) Principles of spatial closure of the mine fires must be taken into account in
emergency plan.

(4) If a fire at a mine is currently concluding the downcast and upcast
party výbuchuvzdorně Fire residues must be plynujícím a coal mine
Fire residues simultaneously with the closing inerted and rescue workers must be protected against possible
or flash explosion (protišlehovými suits
fog nozzles, etc.).

(5) dikes enclosing Fire residues must be tight and must be built on
all approaches to the scene of the fire. Instead of the dam must be designed so that
possibly damaged or leaking dike could be replaced by a new and
to be able to establish a pass to enter the enclosure.

(6) Fire residues in which the risk of accumulation of explosive gases must be closed definitively
výbuchuvzdornými dikes. After an interruption of ventilation
off is leading the liquidation of the accident is obliged to consider the possible dangers
explosion and determine the period for which must be removed
mine rescuers and other workers from the risk of explosion sites, at least to the extent relevant
separate ventilation section.

(7) For the dam Fire residues must be ensured sampling
air mass from space as close as possible to the source of the fire, the air pressure measurement
behind the dam and, if possible temperature measurements in locations as close as possible
the source of the fire.

(8) Dykes Fire residues must be numbered. The same number must be
indicated in the corresponding maps and other records.

§ 191
Check dams


(1) The dikes, which is closed Fire residues must be checked.
Leader liquidation of the accident is required to determine the deadline control dams.

(2) The head of the liquidation of the accident is also obliged to specify locations and deadlines
method for sampling air mass from the closed Fire residues and requirements
technical analysis of samples of air mass.

(3) checks of dams under paragraph 1 shall be conducted until the
is a technical analysis of samples from air mass Fire residues shown that
mine fire is extinguished. Further inspection of the dikes must be carried
designated personnel at least once every 14 days.

(4) The dikes must be safe access and not before them
no stored material.

§ 192

Work around the closed Fire residues

(1) Work in the vicinity of the closed Fire residues may be carried out only
does not jeopardize the tightness of the closure.

(2) Leadership workings beneath the scene of the fire neuhašeným mine fire, burning heap
(hopper) or coal seam in the quarry is permitted if
if there is no danger that in mine workings could fall through burning | || material or penetrate fire fumes.
Part of the fourth

Making the scene of the fire closed


§ 193


Plan disclosure closed Fire residues

(1) safe work procedures in making the closed Fire residues
organization is required to develop a plan that must be approved
Ranger Mine Rescue Station. Commencement of these works allows
District Mining Authority. ^ 39)

(2) The plan must address in particular the way ovětrávání Fire residues in terms
risk of fire and mine rehabilitation influence participation accessed
workings on overall mine ventilation or windy area and determine
necessary security measures with respect to the effects
mine air discharged from accessible in Fire residues.

§ 194

Making closed Fire residues

(1) Make the mines closed due to mine fire
possible only if it is established that the fire was extinguished and there is no apparent danger
renewal.

(2) upcast winds accessible in Fire residues must be discharged into
total výdušného větrního flow so they do not pass occupied
workplace.

(3) Upon recovery průchodního ventilation or a separate ventilation
disclosure of the scene of the fire must be in výdušných winds from these workings
determined at intervals designated organizations
concentration of oxygen, carbon monoxide and dioxide, methane,
hydrogen and optionally higher hydrocarbons. Where signs of renewal mine fire must be
Fire residues again closed.

(4) The disclosure Fire residues is not mine rescuers
entry into confined mine works mainly for the purpose of exploration, sampling
air mass for the technical analysis and temperature measurement.

(5) Completion of the work on the disclosure of Fire residues must be reported
District Mining Authority.
PART SEVEN


Mine drainage
Part first


Protection against water inflows and breakout

§ 195

Distribution under threat in terms of inflows and water inrushes

(1) Mines in terms of threats to sudden large inflows of water inrushes
bahnin and water, or water with gases or zvodněnými rocks (hereinafter
"inrushes waters") is divided into two categories:

A) mines without the break water

B) mines with danger breakout waters.

(2) Mine potentially breakout water is mine, in which were found
aquifer rock or rocks prone to create voids or
which it was ascertained old mines that can not reliably be drained, or
mine, in which the morphology of the surface is a prerequisite to the formation
dangerous flood wave threatening underground mine (at excessive rainfall
etc.). Potentially breakout mine water is also mine, which already
water breakout occurred or which is located in the same or similar conditions as
neighboring mine, in which the water breakout occurred.

(3) Mine or part of the category of potentially breakout waters classified
District Mining Authority. When conditions change, the district mining office at the request of the organization
inclusion canceled.

(4) Any finding that could have an impact on the inclusion of mine or his part to category
down potentially breakout waters, the organization is required to immediately notify
District Mining Authority.

§ 196

Verification hydrogeological and gas situation

(1) To ensure the safety and operation before inrushes water must be
before the opening lines of workings relevant part of the territory to the necessary extent
explored.

(2) exploration work must be verified hydrogeological and gas
ratios. When finding zvodněných or plynonosných horizons must be as completely as possible
verified their physical-mechanical and hydraulic parameters
monitored and chemistry of water and gases to the extent necessary for the design
appropriate security measures and determine an effective method of early
dewatering or degassing. The results of exploration work must
provide the necessary data for classification down under § 195 paragraph. 1st

(3) The drilling of more than 150 meters drilled to verify zvodněných or
plynonosných horizons must be measured their deviation from the projected
axis.

(4) Exploratory work must be documented and evaluated in terms
obtain the most complete data on hydrogeological and gas
ratios. It must be documented in detail and method of disposal
exploration workings and drill holes.

§ 197


Protection against a sudden inflow of surface water

(1) Ústí workings to the surface wellhead and the surface must be ensured
against sudden intrusion of surface water into the mine workings.

(2) Surface streams, reservoirs and permanent discharges of waters near the outcrop
deposits in the range of mining or the relevant catchment areas must be
monitored, checked and plotted in the mining site as a possible source
dangerous inflow. The results of inspections must be recorded in the book
drainage.

(3) under the surface flows or water tanks must be determined
protective pillar, unless ensure work safety and operation in another way.
Mine works there may exceptionally be conducted with the consent of racing down
or a designated employee provided that these mines
interfere with surface streams or bodies of water and do not endanger the safety and
operation.

§ 198

Orientation safety and protective Celik Celik

(1) For the protection of water inrushes zvodněných or plynonosných
horizons or flooded workings must be determined orientation
safety or protective Celik Celik. Celik must have such power,
properties and the spatial position of the terms of that likelihood
ensure the safety and operation.

(2) Approximate security Celik down for insufficiently explored
saturation or plynonosné horizons and the flooded mine
works whose position is not exactly known. The landmark security
Celik, mining is prohibited.

(3) Protective Celik determined for well-researched saturation or
plynonosné horizons and famous flooded mines. The protective
Celik's lead mine workings prohibited.

§ 199

Precautions for mines

(1) For safe keeping of mine works in zvodněných or plynonosných
horizons and their surroundings, close to the tectonic faults and caverns,
flooded mine workings, surface flows and water reservoirs, wells filled with water or
hydraulically connected to zvodněnými or
plynonosnými horizons and similar sources of danger has to be made
necessary precautions.

(2) Safety measures pursuant to paragraph 1, including emergency exits must be on the bottom
potentially breakout water solution of projects approved
racing down. The project must address the method and procedure, including drainage
mine water pumping and determine the criteria for assessing drained or
degassed area and determine safety measures for the approximation
flooded mine works, zvodněným horizons vodotečím reservoirs and water | || if it can not be drained.

(3) To protect against inrushes water from boreholes must be determined
security zone. For the management of mining works in the safety zone must be determined
necessary precautions.

(4) Safety measures under paragraphs 2 and 3 shall be included in
processes.

§ 200

Approximation to sites dangerous waters inrushes

(1) If it is found during drilling or other means source or place
potentially breakout waters, further work is needed to stop until verifying that
identified safety measures correspond to the detected ratios and provide
safety and traffic.

(2) Once you start to work to the point of danger breakout water on
distance determined technological process must lead to further
workings meant constant supervision.

(3) If there is Excavation symptoms breakout waters
work must be halted mine work as possible and ensure workers
from this and other mine workings in danger, immediately recalled.

(4) of the mine hazard breakout of water must be provided appropriate
signaling device, which workers will be in danger of mine
alerted to the break waters and its symptoms.
Functions of this equipment must be checked at least once a month.

§ 201

RECOVERY workings after the breakout of water

(1) RECOVERY workings after the breakout of water draw up the organization process
zmáhacích work, which approves racing mine or his nominee
worker.

(2) In clearing out workings filled with rocks after a breakout
water can be initiated only when it is secured by drainage, ventilation and rescue route
source breakout enough water drained or are

Taken necessary precautions against further breakout waters.

(3) Opening zmáhacích work permitted by the Regional Mining Office. ^ 39)

§ 202

Protiprůvalové dikes and other objects

(1) The layout and design of dams protiprůvalových ^ 40) and other objects
to prevent breakout of water determines the project.

(2) Protiprůvalová dam must withstand the expected pressure water
aquifer rock or gas.

(3) Protiprůvalové dam and other facilities to protect against water breakout
shall be maintained in good condition and are inspected at least once a month
. In closed dikes must be measured seepage dams and
surrounding rock and the water pressure behind the dam. The results of inspections must be recorded in the book
drainage.

§ 203


Security holes
(1) The borehole must be performed and when leaving disposed so as to prevent unwanted connections
zvodněných or plynonosných horizons and
prevent breakout of water or gas outburst in mine workings.

(2) borehole, from which we can expect breakout of water must be safely secured
estuary and equipment for the immediate closure of the wellhead. Wellhead
must be secured against external damage.

(3) In case of danger inflow of water or gas leakage from the hole in the bottom
must ensure water drainage, possibly gas from the well and prevented
accumulation of water or gases in a mine. After fulfilling the purpose of the well bore is
be discarded.

§ 204


Mine Flooding
Flooding mine or part thereof permitted by the Regional Mining Office. ^ 41)
Part of the second


Mine water pumping

§ 205
Pumping equipment


(1) which mine can not pay mine water by gravity shall have
continuously operable pumping equipment consisting of a main or
temporary or auxiliary pumping stations, pipelines and respective
valves and žumpovních corridors.

(2) Calculation of performance and capacity pumping equipment must be based on
hydrogeological conditions. For mine in operation must be based on the average daily inflow
mine water for at least 5 years. For mine
with large fluctuations tributaries must be used
average daily inflow of worst-term.

(3) Pumping equipment must be designed and operated so as to avoid
risk of personal service due to mine water, even
pollutants contained therein.

(4) Drain and discharge of mine water to the surface pressure isolated
system of underground drainage wells and pipelines independent of the main
pumping station must conform to a specific project approved
organizations.

§ 206

The main pumping station

(1) Mine without the break waters must have a main pumping station
with such power that the average daily flow of mine water
was exhausted after 16 hours. Furthermore, it must be alert
least fifty percent deposit in performance, but at least one standby pump
about the performance of the largest pump used.

(2) Mine potentially breakout of water must have a standby power
main pumping station approved racing mine, and must be complied with at least
requirements of paragraph 1

(3) The pumping station can be arranged as lifting
with other parts of the station on the higher floors or levels.
Equipment and pumping power of the pumping station must meet the requirements
main pumping station.

(4) In justified cases it can be established more main mine
stations.

(5) Supply of electricity to the main pumping station must be
secured by two supply lines, each of which must provide
operation of all pumps, including backup. ^ 27)

(6) Pumps, their motors and electrical distribution equipment must be positioned so
to the expected maximum water level ^ 42) will not render the service.

(7) The pump must be on the discharge side shut-off valve, which
be disconnected from the discharge pipe.

(8) When dredging and deepening of pits, while otvírce new floors or
in securing or disposing of mine (pit) can have mine instead of the main pumping station
temporary pumping station. Conditions for its establishment and operation
equipment must be addressed in the project.

§ 207

Auxiliary pumping station


(1) auxiliary pumping station must have a performance that ensures
pumping mine water from the relevant parts of the mine.

(2) pumps and motors, the § 206 paragraph. 6th

§ 208

Automatic operation of the main pumping station

Automatic operation of the main pumping station is permitted if its
equipment meets the requirements of § 219 and if

A) pumps are equipped with an automatic start and stop
within specified limits water level,

B) in the case of pump failure will automatically priming a pump running
backup,

C) the operation of pumps, disorders and states of emergency on the pumping devices are intended manner
signaled to the control room or other designated location

D) operating time of pumps is automatically tracked.

§ 209

Žumpovní corridor

(1) Žumpovní hall main pumping station must be built so that
it can be cleaned during normal mine water inflow
without compromising the safety and operation. Do žumpovních corridors must be set up
access so workers could break out in a timely retreat to the waters
safety of all its parts.

(2) In the break down without water must utility volume žumpovních
corridors of the main pumping station inflow equal to the average of 32 hours.
In justified cases the racing mine permit a reduction in the volume of household
žumpovních corridors up to 50%.

(3) breakout below the hazardous waters shall utility volume žumpovních
corridors of the main pumping station determined by the degree of the break water
shall not be less than the average inflow for 32 hours.
Utility volume žumpovních corridors major pumping stations and the pumping of racing
approves mine.

(4) Mine water must be drawn so that there is always at least half the volume
utility corridors žumpovních main pumping station empty.
In the event that the catchment area is divided into 2 halves must be
maximum permitted rate of its full visible manner indicated.

(5) Before reaching the žumpovních corridors of the main pumping station must be
sump with its cleaning service station and
permanent mine water inflow.

(6) Volume žumpovních corridors of auxiliary and temporary pumping stations determine
organization.

§ 210

The discharge pipe main pumping station

(1) The discharge pipe main pumping station must be at least 2, and each of them
dimensioned to allow your average daily inflow
mine water for longer than 12 hours.

(2) The discharge pipe must be adjusted so that each of them gave
connect all pumps.

(3) The discharge pipe must be protected against freezing.

§ 211

Operation and maintenance of pumping equipment

(1) Operation and maintenance of pumping equipment, including the scope and frequency of inspections determined
Operating Rules, which must contain

A) connection diagram of each pump discharge piping including
controls

B) electrical wiring diagram pumping station and connection
substation,

C) electrical wiring diagram for each pump and signaling scheme
service station,

D) lubricating plan

E) instructions for operation and maintenance of pumping equipment, especially
procedure for putting pumps in operation and when they stopped, and the scope and deadlines
maintenance,

F) at a gas station with automatic operation description auto
control and description of manual control pump operation,

G) the obligations of gas station attendants in case of an accident
pumping station and when you need to increase the water supply to the mine fire
tap

H) any additional requirements that require operation and maintenance of pumping equipment
.

Operating Rules will be posted at the gas station.

(2) The operating time for each pump must be kept. In
gas station with automatic operation must be kept daily records in
period significantly increased inflows of mine water, or sufficient records
month.

(3) Equipment filling station is obliged to inspect the designated officer
least once a day.

(4) Pumping equipment must be inspected once a year. In doing so, it must be verified particularly
performance petrol stations and individual pumps, state

Discharge piping, including its security and condition of deposits in žumpovních
corridors. The results of inspections must be recorded in the book of drainage.
A third part


Measurements, records and documentation

§ 212

Monitoring hydrogeological and gas situation

(1) The organization is obliged to monitor, document and evaluate
hydrogeological conditions and gas deposits.

(2) The organization is also required to identify and track
hydrogeological and gas situation along the border of the mining area and to draw maps
especially flooded surface and underground mine workings neighboring mines including
wells and tectonic faults, if could threaten the safety and operation
.

(3) The findings, which could impair the safety or operation of a neighboring mine
organization is required to immediately report
responsible person of the neighboring mine.

§ 213

Flow rate measurements and analyzes of mine water

(1) Total tributaries and sub-tributaries individual mine water must be
measured at least once every six months. One of the measurements must be made at time
largest annual inflows. The results must be recorded
indicating where measurement and resource inflows,
evaluated and compared with an average daily inflow and quantity of depleted mine water.

(2) Out of tributaries and sub-tributaries of major mining water and
water in the pit with the hoisting device shall be annually
sampled and subjected to chemical or even radiometrickému analysis.

(3) dewatering and degassing wells must be measured inflow and pressure
water or gas within the specified deadlines.

(4) The results of the measurements and analyzes referred to in paragraphs 1 to 3 shall be recorded in the book
drainage.

§ 214

Documentation management

(1) The organization is obliged to introduce the basic mining map also places
breakout water resources risk according to § 199 paragraph. 1, a place where there
risk of seepage of surface water Celik, protective pillars and || | all objects to prevent breakout of water.

(2) Drilling, also crashed, which were reached saturation or
plynonosné horizons and that it could not be isolated from
bearings or workings, must be in the mine site greatly
indicated.

(3) all surface and underground mining works including wells, in which the
after their departure could cause water to accumulate and which were
decided that they will be flooded, must be guided by detailed documentation.

(4) The book must be drainage scheme

A) pipes with all fittings,

B) connecting pumps with an indication of their technical parameters

C) wiring of pumps and pumping stations,

D) žumpovních corridors and tailing pits indicating their utility
volume.

(5) At the bottom of the hazardous waters breakout book must be in drainage
list workings destined to be flooded in the event breakout
waters with those of their utility volume.

§ 215
Mining hydrogeologist


Organization determined to mine potentially breakout of mine water hydrogeology
with appropriate qualifications.
PART EIGHT


Electric and Machinery
Part first

Common provisions


§ 216
Basic provisions


The organization is obliged to issue instructions for operation and maintenance of the equipment that
contain requirements for ensuring the safety and operation.
Instructions for operation and maintenance needs by type of equipment include

A) the obligations of the operator before operating the equipment in the inning

B) the obligations of the operator during operation,

C) the scope, deadline and maintenance,

D) method of securing the device in its operation, moving,
down operations and repair and against accidental actuation,

E) the method of communicating and giving labels,

F) positioning and securing the device after operation,

G) prohibited acts and activities

H) the manner and extent of the recordings on the operation and maintenance of the equipment.

User Manual issued by the manufacturer of the equipment that meets these requirements
organization may declare guidelines.

§ 217


Documentation facility
(1) Prior to installation must be made available to a project, possibly
drawings equipment.

(2) Documentation must deal with ensuring safe operation and

Maintenance.

(3) The device can be made only such changes which will not deteriorate
safety and operation. Changes must be approved by the designated
employee and recorded in the documentation.

(4) The documentation of electrical equipment must also be determined
environment and facilities with regard to risk of electric shock and
terms of coverage and location of electrical equipment. ^ 44) Documentation
electrical equipment for hazardous areas of methane or coal dust
(§ 232 and 233) is required to assess and leading ventilation.

(5) for all equipment to be carried must be
documentation stating their weight and parts that have to be lifted
lifting equipment, must be determined by binding scheme.

§ 218

Requirements for equipment and its parts

(1) The device must have the necessary stability, meet the anticipated
loads and stresses its design and the operating conditions.
Equipment in which action may force an unwanted movement must be securely anchored
. Permitted is just such a construction equipment
allow its safe anchorage.

(2) Equipment or parts that can move spontaneously after discontinuation
driving forces (liberalization, by folding, rolling off, etc.)
Must be secured against unwanted movement.

(3) Equipment must its design allow safe operation, cleaning,
maintenance, assembly and disassembly. Parts of the device, requiring frequent access
workers (drivers, lubricators, adjusters, etc.) Shall be readily accessible
.

(4) Equipment not its design and operation of a fire or explosion
methane gas ^ 45) or dusts. The device must not occur
undesirable accumulation of flammable liquids.

(5) from internal combustion engines can be used only in the underground diesel engine.
It must not be used to drive a stable device.

(6) Measuring instruments to monitor operational data necessary for traffic safety
(manometers, ammeters, etc.) Have significantly marked
leave the measured value.

(7) The equipment must be secured against overflow or underflow
intended operational values ​​or positions when this should result
threat to safety or operation.

(8) There must be no possibility of unwanted during commissioning and startup of its
multiple locations.

(9) Parts of equipment or material or equipment being processed
conveyed if their movement, stored energy, temperature, shape
or otherwise threaten the safety or operations must be secured
suitable protective devices. If this is not possible, it must be dangerous
parts and places consistently and strongly marked.

(10) Openings equipment, especially tanks, ^ 46) crushers, mixers, tanks and hoppers
where there is a risk of falling or forfeiture of persons must be
covered, fenced or otherwise secured.

(11) Equipment technological lines must be set to turn off the station
operator; when it should automatically stop all equipment lines
against the flow of material.

§ 219

Automatically or remotely controlled machinery

(1) automatically or remotely controlled machinery-46a)
can operate only provided that it ensures its automatic
stopping when

A) is not complied with specified operating value

B) a fault in the power supply to the machinery, or

C) a fault in the automatic or remote-controlled machinery or equipment
its operational surveillance system.

(2) automatically or remotely controlled machinery to equip and
manual control. For manual control with automatic or remote control
is deactivated. In place of a remote controlled machinery
ensuring blocking preventing unwanted introduction of machinery
device into operation. If he can change control settings arise
endangering state security work and operation that prevents such a change
appropriate means, which are usually an access code or lock
switch.

§ 220
Protective devices


(1) Protective devices must prevent access of persons to dangerous
space.

(2) Protective equipment not preclude lubrication, inspection, adjustment or correction of equipment
.


(3) protective equipment must perform its function even during power supply interruption
.

(4) Holes guard must have a size selected with regard to
safe distance from the source of danger. ^ 47)

(5) The guard must its design allow machine operation without
its removal.

§ 221

Drivers and indicators

(1) Equipment shall be the main driver for disconnecting from the power
energy.

(2) Equipment powered by two or more motors with separate
start controls must be equipped with at least one actuator, which
can stop the entire device.

(3) Mobile machine used in underground equipped with rechargeable batteries
must be readily accessible disconnecting the battery.

(4) driver must exclude the possibility of its implementation spontaneous
turned on or off. Must not allow simultaneous connection of unwanted features and must have identification
positions or functions and devices it controls.
For controlling the supply of compressed air to the conveyor drive may be used
valve.

(5) controller designed for use in emergency situations must be easily and quickly accessible
from the operator, strongly marked and well
visible. Actuators whose operation must not be interrupted for safety reasons
must be marked in a uniform manner.

(6) The actuator must be protected or located so as to avoid unwanted
control devices falling rocks or other objects.

(7) communications emergency should be made so that their
signals were significantly distinguished from operating signals and operating noise.

§ 222
Pipeline


(1) Pipelines must be securely mounted, suspended or otherwise
secured against loosening or falling.

(2) If the suspension of more pipes must each hook
separately and independently of the other.

(3) Pipelines must be marked according to the purpose or type of flowing substance.
To mark pipelines sufficient color stripes with a width of 20 cm at distances
30 m to

A) mine fire water dark red (cinnabar red)

B) for compressed air line and the blue light (blue light)

C) drained by pipeline yellow (yellow chrome middle)

D) pipeline distributing nitrogen greens (green Májová).

The label must also be at each tap and fittings of these pipes.
Method of marking other pipe determines the organization.

(4) Channels for pipelines must be nonflammable. If not through, must be
covered with removable covers.

§ 223

Parts of equipment under the floor and on the platforms

(1) For operation and maintenance of equipment or parts stored under the floor
must be left enough space to safely open, ventilated and where appropriate
lit and drained.

(2) Platforms for operation and maintenance of the device must be fixed safely
accessible by stairs or ladders and railings provided under § 291
paragraph. 9 and 10. In justified cases it may be removable railings.
Platform floor must not be slippery.

§ 224

Premises and equipment operator station

(1) The establishment and at the operator's facility must be operational
documentation.

(2) Operator stable equipment must be designed so that
operator can safely manage and control. For
device must be left open for the operation of a minimum width of 0.8 meters; u
electrical equipment above 1 kV underground must be a minimum width of 1 meter
, on the surface by a special regulation. ^ 49) The dimensions
must be followed up at least 1.8 meters underground, on the surface at least 2.1 m
.

(3) underground premises longer than 30 meters must have exits at both ends
.

(4) The floor must not be slippery and must be of such strength, possibly by
necessary, temporarily reinforced to withstand the maximum anticipated load,
even when the necessary work on the respective devices (maintenance, mounting
etc.).

(5) In the underground premises and the premises of the permanent service at the surface must be
telecommunications equipment connected to the control room or other designated place
.

(6) when the device is switched off or without supervision, must be
doors to the premises locked. In the presence of personnel on the premises

Must be at least one door unlocked. The doors must open outwards and be
flammable. Organization determines which business must be equipped
equipment to check people entering.

(7) Unauthorized entry into the premises is prohibited. Table
this ban must be placed on the outside of the front door.

(8) The establishment can only be imposed on the supplies needed for
operation.

(9) For the shutdown, maintenance and repair of three or more locomotives on the floor must be established
depot (draw). ^ 50) The depot must be under the tracks
least one mounting hole. Above the pit is placed
lifting device corresponding to the maximum expected load. For hanging
locomotives to establish the assembly spaces.

(10) If the depot is part of a workshop or storage of flammable liquids and solid lubricants or
depot for locomotives with an air motor
filling stations to be separated by a fireproof partition wall.

(11) for the maintenance of trackless mining machinery, ^ 51)
mobile earthmoving and construction machinery, motor vehicles and motor trucks underground
must be set up parking spaces. The parking space must be located in the main
downcast Excavation and reinforcement must be non-flammable.
Parked machine must be protected against water. On the parking spot can be shut
only one machine, around which must be left open
a width of 2 m and a height of at least 1 meter higher than the highest portion
. If they are to be carried out underground repairs must be established
garage, which must be located, building design and equipment
conditions set for the depot (Tie). ^ 50)

(12) Habitat permanent service of the equipment must be protected from adverse weather conditions
.

§ 225


Plant operator
(1) Individual operators can be charged with a worker who

A) meets the requirements of § 15

B) has reached the age of 18, unless the operator of the device is not
set a higher age limit

C) is professionally qualified, ^ 45) ^ 46) ^ 52) ^ 53)

D) was acquainted with the operational documentation

E) passed an examination before a commission set racing down. ^ 82)
term exams and the venue must be communicated to the competent District Mining Office
before the date.

(2) to operate simple electrical devices up to 1 kV can be
commissioned officer qualified in at least seznámeného worker, ^ 52)
operating other electrical equipment with skilled worker's informed at least
. ^ 52)

(3) separate mining operation or a stamping machines and mining equipment
bezkolejového may be entrusted to the worker at least one year experience
operate these machines. Training according to § 15 must be at least 200
hours.

(4) driver mining locomotives must be before the test according to § 15
recommended for this function based on psychological aptitude tests and have at least three months
practice in the mode of transport to be tested.
Training according to § 15 shall be at least 200 hours. The provisions of this paragraph shall not apply to drivers
locomotives on the track 900 and 1,435 millimeters. ^ 54)

(5) The operator must be regularly checked by operating
documentation and regulations to ensure safety and operation. If the deadlines are not set exams
special regulation or the technical standard is determined
organization.

§ 226
Obligations of the user


(1) Before operating the device in a relay operator must
check its status by operating documentation.
Device can only be activated when the proper function of protective and safety equipment
.

(2) Before operating the device, the operator must make sure that nobody is
dangerously close to the device. If this is not possible,
obliged to give advance warning sign endangered places in the manner intended
operational documentation.

(3) The operator is obliged to ensure the removal of defects found on
device. Where the defect or damage that could endanger
safety or operation, the device must not be put into operation. Where
a malfunction during operation, the device must be stopped immediately and ensure
against accidental actuation. If the operator is unable to remedy the defect,
reports that the foreman or another designated employee.


(4) During operation, the operator must monitor the operation of the device and where
it is prescribed for data logging.

(5) If the operational documentation provided otherwise, the operator must at
leave from his station facilities and secured against unauthorized intervention
and accidental actuation.

§ 227

Putting into operation

(1) This device may be put into operation in harsh environments and conditions
for which it is intended, and after the prescribed inspections, tests and
revisions.

(2) Prior to commissioning underground organization is required to report
District Mining Authority to use a new type of mining equipment selected
29) and also new types

A) mining and tunneling machine and pluhovacího device

B) mechanical support,

C) mining belt and scraper conveyor,

D) mine locomotives, motor vehicles and motor trolley

E) mine winch

F) natural and construction machinery

G) drilling rig off rigs for drilling and geophysical work ^ 55)

H) loading machine except bezkolejového mining machinery, ^ 29)

I) mine explosion-proof electric equipment and plynujícím
coal mine.

§ 228


Equipment Operation
(1) To operate the device, in addition to automatic control equipment must be designed
operation.

(2) The operation can be cleaned and lubricated only those pieces of equipment that do not
risk of injury, not only from the place where the worker is not compromised
operation of the device.

(3) Fuel must not be replenished with the engine running, if operating
documentation specifies otherwise.

(4) Equipment must be a manual tool change or other elements
stopped and secured against actuation when the device or its
clamping parts are designed for safe manual tool change
in motion.

(5) arise if during operation pollutants must be effectively
disposed.

§ 229

Machines with diesel engines in underground

(1) When work is interrupted machines with diesel engines for more than 15 minutes
must be the engine stopped and closed off diesel.

(2) For operating machines with diesel engines must be at least once a month
analyzed exhaust gases to determine the concentration
carbon monoxide and nitrogen oxides.
Concentration must be determined after the engine has warmed up to operating temperature, while
idling speed and at rated load.

(3) The machine must be decommissioned if the exhaust gases is
more than 0.1% carbon monoxide, or 0.075% of nitrogen oxides. Do
operation may be included after the error, and after reducing the concentration of carbon monoxide
below 0.08% and the concentration of nitrogen oxides
below 0.075%.

(4) The machine can be operated only with a lockable
injection pump.

(5) The machine must be equipped with fire-fighting equipment with stable distribution and
hand extinguishers.

(6) Maintenance is required in addition to the obligations specified in § 226
watch as smoke machines. When the smoke deterioration is obliged to report the fault.
When leaking diesel or oil is required to stop the machine, to close
supply of diesel and failure to report. Similarly, the operator is obliged to proceed in
nausea.

(7) Upon detection of fire, the operator must stop the engine, put into action
firefighting equipment and to proceed under § 18th

§ 230

Maintenance, assembly and disassembly facility

(1) Maintenance of equipment must be carried out in the scope and deadlines specified
operational documentation. Their results must be kept.

(2) The organization shall decide whether to work safety or traffic
it is necessary to develop a workflow for assembling or disassembling the device.

(3) The organization is obliged to equip workers performing maintenance
measuring devices, tools and other aids necessary for
ensure the safety and operation.

(4) If required by the nature of the maintenance work must be OFF
and secured to prevent accidental actuation. After completion of these works
must be certified correct operation.

(5) Inspection of mobile machines used in underground
must be carried out at least once every 14 days. Examination shall be conducted by staff at all

Accessible parts of the machine (without disassembling). During the tour must be
tried various machine functions.
Part of the second

Electrical equipment

Section One


Requirements for the installation of electrical equipment

§ 231
Basic provisions


(1) Electrical equipment must conform to its design environment and
spaces, ^ 44) in which they operate, especially in terms
risk of electrical shock and explosion of methane, coal dust or other
forming agents explosive mixture with air.

(2) should not be used underground provisional electrical equipment. ^ 56)

(3) Distribution of electricity to be drawn into the surveillance
schema and map the distribution of electric energy. ^ 7)

(4) At least twice to independent electric power supply of each
provide the necessary power, it is necessary to equip underground mine

A) a hoisting device for transporting people from depths exceeding 300 m, or

B) gassy II. hazard class or

C) classified as hazardous breakout mine waters.

(5) All cables and protective conductors, with the exception of the earth
management (§ 231b paragraph. 2) must be copper. Protective conductors that are mechanically protected
unless stipulated otherwise, must have a section
least 6 mm2.

§ 231a

Electrical network in the bottom

(1) for power distribution in the mine can be used only
electrical network protection with automatic disconnection from source, on condition that:

A) at low voltage, all live parts isolated from earth and all inanimate parts
indirectly connected with the ground-56a) (network IT) and simultaneously
monitored network device to the insulation monitor (hereinafter "
insulation watchman state ")

B) at high voltage

First the source node is connected to ground via an impedance and limiting all
inanimate parts are directly connected to earth manner appropriate to protect
grounding with fast switching off-56b) [IT network (r)], or

Second All live parts are separated from the ground, and all inanimate parts are
indirectly connected to earth manner appropriate protective earth-56c)
(network IT).

(2) electrical grid under paragraph 1. a) with a power greater than 1 kVA
for lignite mines with a power greater than 3 kV, can be operated only
assuming that the insulation resistance drops below the network 15 O / V
provides indication of this condition and in gassy mines addition
ensure automatic shutdown of the network.

(3) electrical grid under paragraph 1. a) with a power less than 1 kVA
for lignite mines with a power of less than 3 kV, can be operated only
assuming

A) it is operated as a network in accordance with paragraph 2

B) for wiring cables are used with armor, metallic or semiconducting shield
shielding and protection against short circuit is designed so that
disconnected from the power circuit in time to 0.1 seconds when | || short circuit in an electrical circuit, or

C) network meets the requirements for non-flammable electrical circuit.

(4) Electrical network pursuant to paragraph 1. b) in gassy mines II.
Hazard classes must be operated so that

A) ground current at a single line ground fault network which supplies
moving machines in excavation and Ruban not exceed 7 A

B) the value of the permissible contact voltage does not exceed 50 V and

C) decrease the insulation resistance of the network was signaled into place a permanent
service,

D) power switch, the cable outlet is powered
electrical equipment located on the premises of SNM, was equipped with blocking
turn on the pin at the insulation resistance at the outlet of less than 50
ohm / V.

Checking insulation resistance network is governed by the rules of operation.
Measured insulation resistance values ​​are recorded.

§ 231b

Grounding system in the bottom

(1) To ensure safety against electric shock,
undesirable effects of electrostatic charge and stray currents must be established
mine grounding system, which includes the main ground connection.

(2) The grounding line must be composed of copper wire or copper
shielded cable with a cross section of 50 mm2 or galvanized steel
conductor having at least 95 mm2; if a galvanized steel wire used
tape must be at least a thickness of 3 mm. The grounding

Line must be connected to at least two artificial earth electrodes.
Cross-section of the main ground lead must not be weakened.

(3) The main earthing cables are conductively connect all parts of inanimate
electrical equipment requiring protection and grounding conductive objects
longitudinally or led Excavation (pipes, rails, etc.).
Protective conductor of the electrical equipment above 1 kV must have a section at least 16 mm2
, with the exception of devices attached a tow cable, which connects
ground conductor trailing cable.

(4) The grounding resistance and contact resistance grounding system must meet the requirements
method used for protection. Execution Main
ground lead and piecing strojených Earthling must allow
their examinations. Resistance grounding system expressed in O
not be greater than the proportion of 50 to the sum of the lengths of all cables for voltages above 1 kV,
expressed in km, which are connected to the same power source, and simultaneously
not exceed 15 O . the ground conductor is on the surface
connected to the ground line substations, from which is powered mine.
Main grounding wire is performed according to technical standards relating to
this provision.

(5) resistance grounding system at the point of connection of inanimate parts
not be greater than 15 O in low voltage.

(6) Check the status of the main ground lead
be performed at least once a year and every mine tremor in mines affected
concussion; It does not apply to the main grounding wire in the joint lining.

(7) Connections on the main ground lines must be protected against corrosion.
Joints between galvanized steel or galvanized steel rope
strap and a copper conductor must be protected so that between them arose
galvanic cell or protected by a protective coating to prevent moisture
to join.

(8) Inanimate of electrical devices up to 1 kV must be connected to the main
copper grounding wire grounding conductor, which is part
cable. For cable lines with protective conductor must not be used as
power lead.

(9) Equipotential bonding dead parts of electrical equipment and their connection to the main earthing
management is performed according to technical standards-56d)
relating to this provision.

(10) For media device, where it is necessary to protect against inanimate parts
dangerous contact voltage is carried earthing protection either directly on
protective earthing system protective copper conductor having
least 4 mm2 via one pair of wires in the cable. For
protective conductor can also be used cloak and armor cable.
Communication and telecommunication devices without a direct conductive connection to the power circuit can protect
separate grounding resistance of which does not exceed 75 O.

§ 231c

Location of electrical equipment above 1 kV

(1) Electrical equipment should be installed so as to allow
sufficient heat dissipation from it and secure access to him and to
prevent mechanical damage in excess of creating danger.
Electrical equipment above 1 kV, with the exception of cables including fittings and
electrical equipment for consumption of electricity and electrical equipment
suspended from the monorail or the reinforcement of mining
work or firmly attached to other technological devices
is placed in a chamber or recess in the extended profile of the mine work.

(2) Electrical installations above 1 kV and above the belt or scraper conveyor
is positioned so that the transported material transported and electrical equipment
a clearance of at least 0.4 m. In this electrical equipment with
apply § 301 paragraph. 1 point. b).

(3) Clearance for the operation and maintenance repositionable
electrical equipment above 1 kV shall be determined in accordance with § 224 paragraph. 2. If
into this space extends clearance profile of transport equipment, must be simultaneously
with mining transport operation, and maintenance of electrical equipment
. When determining the passage profile monorail is also taken into account
normal fluctuations of the vehicle (§ 292 par. 6). After completion of the shipment must
vehicles or cargo to interfere with the free space for operation and maintenance
repositionable electrical equipment.

(4) Electrical installations above 1 kV in the areas of longwall excavation and placed
so that its distance from the face or contact points between the longwall or dobývky

With vtažným or výdušným mining work in the direction of the longwall mining
or was at least 20 meters.

§ 231D

Switching equipment above 1 kV in areas assigned to the 2nd or 3rd degree
risk of rock bursts

(1) can be operated only with the power switch control circuit that can be controlled from
places designated racing down.

(2) The power switch is above 1 kV must be protected to ensure
its automatic shutdown when exceeding the set values ​​
disturbance variables. Protection against short-circuit currents must provide automatic disconnection
leadership in interphase short circuit. Protection must allow
setup and control tripping characteristics so as to ensure protection
selectivity.

§ 232

Classification of areas of gassy mines in terms of the danger of explosion of methane


(1) The underground gassy mines with regard to the risk of explosion
methane and requirements for the operation of electrical equipment are divided into

A) premises without any risk of methane explosion ( "the premises BNM")

B) areas with potentially explosive methane (hereinafter referred to as "space SNM").

(2) The premises are classified BNM underground spaces ventilated vtažnými
winds that have not been used in places where coins or conquers, and
which is not directly related to vyrubanými premises or nevětranými and not closed
mine workings, which are at their inclusion and
during their operation designed such organizations volumetric flow mine
winds, the concentration of methane in the mine air will not exceed 0.25% and at
ventilation failure or stopped the period determined by
emergency plan is in them precluded accumulation of explosive mixtures of methane
air.

(3) The premises specified in paragraph 2 space SNM.

(4) In accordance with paragraphs 2 and 3 are classified as surface area of ​​deep
mines, which are located electrical equipment and where there could be a risk of explosion
gases, particularly space above ohlubní upcast pit
space around the main fan diffuser at a distance of 30 m
.

§ 233

Classification of areas of coal mines in terms of the danger of explosion of coal dust


(1) The underground coal mines in terms of the risk of explosion
coal dust and requirements for the operation of electrical devices to divide


A) non-hazardous coal dust explosion (hereafter "space
BNP")

B) areas with potentially explosive coal dust (hereafter "space
SNP").

(2) The premises are classified BNP underground spaces in which they occur
coal rubble, creates a continuous layer of coal dust and coal dust
is removed regularly.

(3) The premises specified in paragraph 2 space SNP.

(4) In accordance with paragraphs 2 and 3 are classified as surface area of ​​deep
mines, which are located and where electrical devices could
there is danger of explosion of coal dust.

§ 234

Power stations and distribution facilities

(1) Electrical stations ^ 60) must be located and designed so that it
under the conditions laid down for the inclusion of space prevent illegal
buildup of methane and ensure that electrical equipment in it was not exposed
adverse influences, in particular moisture and dust and
risk of mechanical damage. Reinforcement electrical stations must
safely withstand expected pressures mountain.

(2) unmatched power station-57) underground
may not meet the requirements of § 224 paragraph. 6 and 7.

(3) in a closed electrical stations may enter only workers
determining the operating or maintaining electrical equipment
who meet eligibility requirements under a special regulation. ^ 52)

(4) electric station must be single-line diagram of power distribution.

(5) electrical station and from electrical switchboard can not be
material stored and maintained there must be space for the operation and maintenance
.

(6) Vents in the chambers of the major mining substations must be fitted tightly
lockable flaps positioned in front
walls or the steel door and must be covered with wire mesh or grid with
dimensions of 15 x 15 mesh mm.

(7) The space at the entrance to the mine substations and transformers must still be
free.

(8) If there are spaces in which electrical equipment is located
when wet or in environments with high humidity, it is classified into spaces

Especially dangerous in terms of protecting non-living parts of electrical equipment
against electric shock. Increased protection
can be done only by using an RCD or ground fault protection
state connected to the shutdown when exceeding the limits set by the manufacturer.

§ 235

Cables and cable lines

(1) cables used in underground must have an outer wrapper of materials that do not support
spread of fire.

(2) cable distribution above 1 kV can be mined in mines and workings of
used only cables with metal shielding or cables with metal shielding
lived in other mines can be used with cables || | metal armor. Metal armor and metal cable shield connects with
grounding system at both ends of the cable and at the locations specified
operational documentation copper grounding conductor, whose cross-section is at least
6 mm2 phase conductors at up to 50 mm2, 10 mm2 with a cross
phase conductors up to 95 mm2 and 16 mm2 phase conductors of 95 mm2
. Metal shield vein connects with the grounding system according to § 240b paragraph
. second

(3) The SNM spaces and spaces SNP may be in the network with security guards
insulation condition used only cables with metal armor, metal
shielded metal shield lived or semiconducting shield.

(4) cables, with the exception of cables stored in the cable ducts, cables
firmly attached, cable on spools and cables for mobile equipment
or machines must be resiliently suspended in the upper half of the mine to
cable hinges pitch hinges more than 3 m. the organization shall
way to save, gripping and hanging cable lines in service
documentation.

(5) Storing, mounting and hanging cable lines must meet the following conditions
:

A) communication cables must be in mine workings draping
separately from the power cables; Cruising these cables is permitted only adequately
case. Power cables and communication must not touch each other,

B) cables must store, combine and connect so that the voltage
due to the weight of the cable and fittings is not transferred to the wire;
fittings must be individually suspended,

C) rigid mounting wiring is permitted only in mine
works with reinforcement and unyielding in mine workings minted in solid
rocks that do not require reinforcement,

D) wiring must be positioned so that it is accessible
inspections; This guidance does not apply to boreholes and passages for the cable.

(6) vertical mine workings (§ 294 par. 1), with the exception of drillings and
chimneys must be firmly fixed cable lines on the cable bracket
built independently of the gear mining work. Distance consoles may be the most
6 m. In the part between cable handles may be burdened
keeping only its own weight. Cable clamping fixture must be such that
cable is damaged.

(7) Requirements for fastening cables under paragraphs 5 and 6 do not apply to cable
lightened the tension hanging on a rope supporting and self-supporting
cables. These cables must be fixed at least every 6 so that
their weight not transmitted to the conductor or to terminal wires.

(8) in the borehole must be cable, except for self-supporting cables, suspended on a carrying cable
least every 6 so that its weight is not transmitted to neither
terminal to the cable conductor. Between the two handles may be burdened cable
only its own weight. The supporting rope including the anchor must be four times the initial
safety due to the thrust exerted
weight of the suspended cable, and may be anchored to the reinforcement of the borehole.
Cable in the borehole may be associated.

(9) The well designed for the cable must be lagged. Construction of the wellhead and
cable clamps must not damage the cable during its storage and in its
continuous operation.

(10) Cable lines must meet the following conditions:

A) trailing cable for powering the stamping and mining equipment above 1 kV
must be stored in storage cable; shift cable to the coalface and storage of cord
at the coalface must be addressed in the operational documentation

B) cable for powering the electric machine in the face mined the mine
must have sufficient reserves in order to avoid transferring tensile stress at
cable wires when moving the machine,

C) coupling and socket connections can only be used on moving

And portable cable lines, connecting the two parts must be in the open state
protected by a cover against mechanical damage and pollution
,

D) management must be carried out in accordance with the technical standards stipulating
requirements for dimensioning and protection of electrical wiring,

E) the smallest allowable cross- section is lived in cable power lines
1.5 mm2, in the media, telecommunications and control cables is the smallest allowable
core diameter of 0.8 mm; It does not apply to non-flammable circuits

F) mobile connections, if not reeling can be loaded only
according to the conditions specified by the manufacturer

G) unused cables must be short-circuited on both ends of insulated
or otherwise securely closed.

§ 236

Cables mobile devices

(1) for the trailing portion to the movable supply line devices must be used
trailing cable. For lines above 1 kV to movable devices must be used
trailing cable with metallic or semiconducting shield and lived
common metal shield.

(2) on the trailing parts of the tow cable can not be used nor quick
other coupling fittings.

(3) The tow cable must be secured against pulling out of the outlet.
Veins trailing cable outlet must not be under tension or torsion.

(4) If the trailing cable gland on the mobile device transmits
tension cable must be fitted with an interlocking device that shuts
mobile device when exceeding the allowable tension in the cable.

(5) Moving the machine can be operated only if it is ensured
its automatic disconnection from source when not being met
requirements for protection against dangerous contact with dead parts. ^ 60a)

(6) The method of storing the trailing cable, control storage and handling
trailing cable determines the operational documentation.

§ 237

Control and safety circuits

(1) The control circuits automatically or remotely controlled programmatically
equipment must be powered from an independent source.

(2) Control circuitry is performed as an isolated or pole
connected to the protective earth. ^ 61) If executed as
pole connected to the protective conductor must be coils of contactors, relays and solenoids
always connected to one pole on the reverse (grounded) conductor.
All contacts must be connected to an ungrounded branch, which must be protected against short circuit
.

(3) control and safety circuits of technological equipment for conducting
mining works, transportation and disposal must be made so that when
control circuit interruption or short circuit on him or power loss has stopped
device. These requirements may be met by those
control and safety circuits, where there can be danger to personnel or equipment
.

(4) When stenciled and interconnect protective conductor must not be used
phase voltage as voltage control, except when the correct
function control circuits ensured even in the ground connection.

(5) For installations which when exceeded the predetermined position may be
threat to safety or operation must be

A) limit switch defining a predetermined position involved in the power circuit, or


B) two limit switches in the control circuit; in such a case must be
a limit switch connected to the control circuit of the drive and
second circuit operating coil switches, or

C) for facilities controlled by the program processor two end positions
data in the software.

(6) If the device is equipped with an electric lock
ensuring the safety of persons, has in its operation may stop device.
In this case, the device can be put into operation again only his
conscious disengaging.

§ 238

Floating pumping station

(1) Floating pumping station must be anchored to the movement
not supply cable mechanically stressed.

(2) AC cord stored in water or the water may be associated
connecting fittings.

(3) The controls must be placed at the power supply on the shore.

(4) Floating pumping station must be grounded earth point on the shore.

§ 239
Trolley traction


Trolley traction may be on coal and gassy mines
used only in areas BNM and BNP. Using the overhead traction at these mines and

Operating conditions approves Czech Mining Office.

§ 240

Safety signs and equipment

(1) For the power station must be a security table "use water or foam
device", with the power station equipment above 1 kV must be
table "High Voltage - dangerous!".

(2) For the distribution equipment above 1 kV located outside a closed
electrical station, except for the cable must be safety signs
"High Voltage - life dangerous to touch the electrical equipment!"
and "use water or foam device". For other distribution equipment
if they are placed in a conductive environment (in wet areas with conductive flooring
etc.), And where could there be a risk of accidental contact with live parts
, the table must be "Warning - life
dangerous to touch electrical equipment ".

(3) In the closed electric station shall be posted instructions
first aid at electric shock.

(4) In a closed electrical station, besides secondary and advanced
substations, ^ 60) must be

A) dielectric carpet,

B) dielectric gloves in a case

C) voltage tester,

D) shorting kit,

E) rescue insulating hook

F) the security table under a special regulation. ^ 62)

§ 240a


Canceled
§ 240b

Using cables with shielding layer

(1) for the supply of the moving equipment or machinery trailing cable can be used SNM
areas with a low voltage cable with a semiconductive shield
or cable with metal shielding and lived voltages above 1 kV cable with a
a metal screen or metal screen veins, excluding non-flammable cable
circuits. Portable electrical equipment or machinery must be so equipped
if they are to be moved under tension.

(2) semiconductive layer and the metal shield of the cable cores must be connected
protective relay or both ends of the cable electrically connected to the grounding
leadership. The outer metal shield must be connected to the grounding line.

§ 240c

Shutting high voltage distribution earth fault

Cabling a voltage of 1 kV substation supplying
outpost located in the premises of the SNM must be equipped to ensure
disconnect terminal with ground faults.
Section Two


Operation of electrical equipment

§ 241

Worker to control the installation, operation and maintenance of electrical equipment

(1) Organization determined for each run mine with electrical equipment
management for installation, operation and maintenance of electrical equipment person who has
addition to qualification requirements under a special legal regulation
^ 52a) for gassy mine university education in
master's degree program in technical sciences and technologies
focusing on electrical engineering.

(2) If a staff member designated pursuant to paragraph 1 can not directly manage the installation, operation and maintenance
electrical equipment, the organization is required to determine
another worker qualifications under a special regulation ^ 52) for direct management of these
activities.

§ 242

Special conditions of electric equipment

(1) Whenever the concentration of methane in the mine air space BNM
0.25%, may appear in this space remain in operation only electrical equipment
referred to in paragraph 2 and the devices on which it so decides Head
liquidation of the accident. Other electrical equipment in this area must be
off.

(2) in the space SNM may only be used in categories M1 and M2
^ 52a). In the space of SNM, for which approval is issued racing down the
increase in methane concentration according to § 83 paragraph. 5 point. b) may be used only
device M1.

(3) Whenever the concentration of methane in the mine air space SNM
1.5% may appear in this space remain in operation only electrical equipment
M1 and the devices on which it so decides leadership disposal
accident. Other electrical equipment in this area must be turned off.

(4) in the space SNP may only use the device category M1 or M2
whose surface temperature does not exceed 150 C. The stack of coal and
space with him directly related to the distance of 30 m may | || use only equipment category M1.

(5) In the cases referred to in paragraphs 1 and 3 must be taken promptly

Measures to ensure the safety and operation.
These measures must be part of the emergency plan. Head of the liquidation of the accident determined
conditions for the temporary operation of electrical equipment, which according
paragraphs 1 and 3 should be disabled, and possibly turn them on progress.

(6) in the space of SNM and SNP must power electric circuits on
workplaces that are not occupied for more than three hours, off and
secured against unintentional activation, in addition to power devices, which are necessary
to ensure the safety and operation.

(7) After turning off electrical equipment of unknown causes must be before
recloser discovered the reason for shutdown and possible defect is corrected.

(8) After finishing work, the mobile device must be in cases
designated operational documentation supply wiring disconnected from
voltage or be safety and traffic provided otherwise.

§ 243

Work on electrical equipment

(1) Work on electrical equipment energized ^ 63) in addition to the media
device can be carried out only rarely. For installations over 1 kV for
work energized regarded as validation circuit condition.

(2) Before starting work on the electrical system must be energized in
radius of at least 1 meter removed and, if this is not possible, disposed
combustible dust.

(3) When working on live electrical equipment that is not intrinsically safe
must be in space SNM following conditions:

A) prior to the opening of explosion protection must be checked
mine air composition according to § 109 para. 1 point. C);
detected methane concentration must be logged

B) the concentration of methane in the area SNM must not exceed 1% and shall be
after the work period metanoměrem monitored and recorded,

C) coal dust must be within a radius of 5 meters removed and if that is not possible,
must be disposed of; This condition must be maintained even in areas of the SNP.

(4) In the basement is on electrical equipment above 1 kV voltage
permitted only authentication circuit condition and phasing of transformers and lines, and
only in major mining substations, for gassy mines but only || | main substations classified as space BNM. On and off
unsecured electrical equipment is allowed to operate only under the conditions laid down
special regulation. ^ 63) Other electrical work
equipment above 1 kV voltage is prohibited.

(5) Work on electrical equipment under voltage may only be carried
appointed staff with qualifications at least for independent activity. ^ 52)
^ 63)

(6) Other requirements to ensure the safety of electrical work
device establishes a special regulation. ^ 63)

§ 244

Maintenance of electrical equipment

(1) Maintenance of electrical equipment must be carried out in accordance with § 230 and
special regulations. ^ 64)

(2) Method, deadline inspections, maintenance and inspection of electrical equipment determines
organizations operating documentation.

(3) During inspections must be checked

A) electrical equipment and cabling are not damaged or improperly
used

B) to protect against electric shock (watchdog function
insulation condition, protective ground covers, etc.)

C) is around electrical equipment maintained clean and tidy, held
space and are in good condition, protective equipment and fire
devices.

(4) When reviewing the catenary underground must be measurement and calculation
detected voltage drop, which must not exceed the rated load at
20% of the open circuit voltage.

(5) The gassy mines II. Class risk must be
overcurrent protection for voltage up to 1 kV

A) are tested before being put into operation and then at least once every six years
,

B) functional verification before they are put into operation and
least once every two years and after every relocation.

(6) The overcurrent protection for equipment above 1 kV must be tested and functionally
verified before they are put into operation and thereafter at least once every three years
.

(7) The relay protections and automatikách must be carried

A) primary tests on electrical installations of high and very high voltage


First when the electrical equipment into operation,

Second instead of every third secondary test,


B) secondary test

First electrical installations of the main transformer stations
high and very high voltage once a year,

Second other electric equipment of high and very high voltage
once every two years,

Third electrical equipment up to 1 kV in the range of checks and verify proper function
once every three years.

(8) Thermal protection is tested in all articles. Article locking
overload is tested by turning off protection characteristics while
from the nominal current of the appliance. Article protecting against short circuit,
if he is equipped with protection, will be tested at the lowest current at which
is said by the manufacturer to act article. Electronic protection
tested according to the manufacturer's instructions.

(9) To test the relay and automation
organization is required to draw up the operating documentation.

(10) For the electrical switching equipment above 1 kV operating
documentation referred to in paragraph 2 shall determine the manner and deadlines for inspections at least to this extent:

) Visual inspection at least once per shift, driven
mines and coal faces and at least once a week with other switching devices
above 1 kV

B) verify the condition of the insulation built-in test equipment for power
switches above 1 kV mined in mines and workings of each
before turning the power switch off and after any current protection
short circuit or ground fault and at least one two months for other
circuit breakers above 1 kV

C) verify the condition of the insulation built-in test equipment for power contactors
above 1 kV mined in mines and workings of each shutdown
action current protection circuit and after each treatment, the relay switch on
blocking off cable reduced
insulating state, and at least once every two months for other power contactors above 1 kV

D) functional testing of current protections for switching equipment above 1 kV, and it
test button or software command mined annually in
mines and workings, verification backstop on after
equipment overcurrent protection or verification interlock circuit that prevents operation of the terminal
reduced insulating state at least once a year at the facility
mined in mines and workings of a
least once every three years for other switching equipment above 1 kV

E) opening the switching equipment above 1 kV and inspection after every shutdown
short circuit current protection, then once a year at facilities in mined
mines and coal faces and at least once every three years for other switching devices
above 1 kV.. "

§ 245

insulation checks

(1) insulation monitoring the state must be in those electrical networks where it provides special regulation
. ^ 67)

(2) monitor the insulation on electrical networks in the underground should not be
decommissioned. If it is not connected to the mains off guarded
when insulation condition must indicate this fall
into the control room or other places with permanent service.

(3) the grid can be turned off after insulation monitoring
put under strain after the error.

(4) electrical network, which is a drop module or ground connection
insulation monitoring only signaled must be at
an earth fault immediately begin work on determining the cause and place
ground connection. For the duration of ground connection must be ensured
safety and traffic
appropriate safety measures.

(5) Insulating electrical construction must be monitored by measuring
device's built-in ground fault protection
least once a day; It does not apply to networks with power up to 1 kVA, for lignite mines within 3
kVA.

(6) Accuracy ground fault protection functions including signaling or
off when insulation condition below a specified threshold must be checked
worker with skills to work autonomously
least once a week.

(7) If the earth fault in electrical networks up to 1 kV while
part of the enhanced protection against hazardous contact voltage on
dead parts of electrical equipment or protection against short circuits must provide
switching network.

(8) After finding the place an earth fault in the mains above 1 kV
must be in areas SNM SNP or faulty electrical equipment immediately

Off. The device can be re-started until the problem is corrected.

(9) If used in underground RCD, checked their proper function
worker qualified for independent activity
least once a month.

(10) Electrical network may be operated at fault current
protectors.

(11) after turning off the power supply RCD
this can be re-energized after the error.
Section Three

Lighting


§ 246

Mining personal lamps

(1) In the underground, the surface work while handling explosives
and in areas with potentially explosive gas and dust may be used only
personal mine lamps ^ 29) assigned to the organization. These lamps must
desired intensity of at least 10 hours.

(2) Mining personal lamps must have the type designation and registration number
organization.

§ 247

Equipment workers personal lamp

(1) Workers who join the underground and are in accordance with § 4 para. 9
equipped private mining lamp, are required to have a lit lamp
even in places with permanent lighting.

(2) Workers on the surface who work in hazardous
explosion of gas or dust or attend to these places must be at
dark or poor visibility equipped with mine personal lamp.

(3) Other workers on the surface, carrying out other work
activity on unlit areas or performing its work
errands, to be used in dark or poor visibility
equipped with suitable electric lighting.

§ 248
Portable lights


Crews at workplaces that require inspection of the ceiling, walls or
slope greater than 5 meters must be allocated portable lamps.

§ 249

Issue and receipt of personal mine luminaires

(1) Mining personal light when dispensing must comply with the technical requirements
should be clean and locked. The battery must be recharged at
prescribed capacity.

(2) Allocated mining personal light worker is obliged to accept the dispensary
personally. When the takeover is required to test its function and
ascertain whether any obvious damage. When finding fault
is obliged to apply for a replacement lamps.

(3) Mining personal light worker is obliged after finishing work
cast himself in the dispensary. Detected faults or damage
luminaire is required when submitting the report to a designated employee.

§ 250

The number of personal mine lamps and their control

(1) The number of serviceable mine personal lamps must
lamp room or dispensary at least 5% higher than the number of workers
which they are assigned.

(2) Mining personal lamps intended for mine rescuers should be particularly
labeled and stored separately.

§ 251

Handling mining personal lamp

(1) The organization is obliged to instruct workers on how to treat mine
assigned a personal lamp and what consequences may arise
its damage, unauthorized opening or unauthorized use.

(2) The employee is obliged to mine personal lamp
protect them from damage and may not open or service.

(3) The employee responsible for the state mining lamps from his personal
acceptance into submission. Arbitrary exchange of personal mine luminaires
among workers is prohibited.

(4) Where a worker at the mine personal luminaire fault that
prevent its safe use, or if the damage is
obliged to report it to the supervisory authority and replace it with the spare.

§ 252
Establishing lampoven


(1) issuing and receiving personal mine luminaires
charging batteries and preparing and replenishing the electrolyte must be established
lamp house. When used in no more than 100 personal mine luminaires can be
lamp-place for these activities used room designed
organizations. These must be provided in accordance with § 253 paragraph. 2 to 5

(2) The organization shall identify the person responsible for the operation
lamp room.

§ 253


Lamp Room Amenities
(1) The lamp room should have at least the following rooms:

A) for the delivery and receipt of personal mine lamps and charging batteries

B) maintenance of personal mine luminaires

C) for lamp-workers.


(2) The rooms mentioned in paragraph 1. a) and b) must have hot and cold water
and easily washable walls and floor. The floor must be of
impermeable material resistant to the action of the electrolyte and a slope
to the drain point.

(3) All room lamp room must be thoroughly ventilated.
Ventilation room for charging batteries must be so effective that
concentration of hydrogen in the atmosphere is not more than 0.5%. The composition of the atmosphere is an organization
required to check at least once every three months analyzing the sample air
taken at the most inconvenient place and time.

(4) Working tables on which cleans and fills personal mine lamps
must have an upper plate coated with washable material resistant
effects of electrolytes.

(5) All the lamp-room and equipment must be maintained in a clean
, in particular, must be removed immediately spilled electrolyte.
Smoking and open fires are prohibited in the lamp.

(6) Room where we work with the electrolyte must be further equipped
neutralization solution to provide first aid in case of damage to skin and eyes
electrolyte.

(7) in the lamp must be accessible and highly visible site posted

A) lamp-operating rules and guidance on records issued and returned
personal mine luminaires

B) instructions for the use of personal mine luminaires

C) table commands and prohibitions under this ordinance,

D) guidance on safe working practices when working with electrolyte
about first aid.

Workers must be familiar with this documentation.

§ 254

Preparation, checking and refilling of electrolyte

(1) preparation, replenishment and control for battery
can only be performed by dedicated personnel, according to the manufacturer's instructions fixtures.

(2) To prepare the filling of electrolyte and batteries must be used
device which prevents splashing and spilling electrolyte.

(3) handling electrolyte organization is required to allocate
workers personal protective equipment, especially protective shield
apron and gloves.

§ 255
Charging batteries


(1) Charging batteries should be carried out according to manufacturer's instructions and
controlled measuring instruments.

(2) Mining personal lamps must be maintained so that the battery compartment
lamps or prevent dangerous accumulation of gases produced during charging
or degassing after charging.

§ 256

Lighting fixtures fixed

(1) Locations for which this decree establishes permanent lighting must be equipped with fixed
lights. Fixed lights must also be supplied without a permanent establishment
service.

(2) Status lights fixed lights must comply with technical parameters of light
^ 68) must be checked.

(3) Lamps must be positioned so that it is accessible for maintenance and cleaning
.

(4) The illumination measurement must be performed within the time limits specified by
operational relations department.

§ 257

Places with permanent lighting on the surface

(1) Permanent lighting during operation in dark or poor visibility must


A) permanent workplace and other places where they are staying workers

B) devices that still needs to be operated or who require constant
control

C) other designated places (transitions and crossing roadways, etc.).

(2) Lighting workspaces for mobile machines with electric drive
must ensure its own lighting equipment.

(3) Other mobile equipment (bulldozers, loaders, cranes, etc.).
Must be in dark or poor visibility illuminated so that handling
them and work on sites in their vicinity was safe.

(4) Electric station facility and a permanent service, where upon
failure Permanent lighting could be a risk of injury must be
equipped with emergency lighting. This lighting may not be as dark or poor visibility
lit, if provided its automatic switching on of
alternative source fail constant light.

§ 258

Places with permanent lighting in the underground

(1) Permanent lighting during operation must have

A) a ladle jam and inclined slopes,

B) platforms and their immediate surroundings,

C) the establishment is permanent service,


D) places on the track with mechanical transport, which are in the inning still
operated,

E) wall contol equipped mechanized reinforcements

F) other designated places.

(2) Engine heavy machinery and power stations with permanent service
must be equipped with emergency lighting. These lights may not illuminate
permanently, if provided its automatic switching on of emergency power failure during
permanent lighting.

§ 258a

Illumination mobile machines in underground

(1) Mobile machine, with the exception of the mining combine, and the machine is powered
air energy can be operated only if it is equipped with its own
lamp to illuminate the working area of ​​the machine.

(2) Mobile machine driven from power source located on this machine must be equipped
end red light and red reflectors.
If the machine is intended for driving distances greater than 50 meters in both directions
must be equipped with white and red lamp and red reflectors on both sides
machines; shovel loaders, may not meet this requirement
shovel on hand.

(3) Mobile machine with a design speed drive above 20 km h-1
must be equipped with the brake lights.
A third part

Machinery

Section One

Mining machinery


§ 259

Mining and tunneling machines

(1) miners, plow equipment and embossing machines must be equipped with a dust proof
equipment and gassy mines II.
hazard class device also reducing the possibility of ignition of methane from the cutting machine
body. Their operation without these devices is prohibited.

(2) shearers, which moves skidded along the scraper conveyor
dipping more than 9 degrees or invert skid after dipping
greater than 18 degrees, shall be secured by a separate locking device, which
prevent his driving. Other shearers must be secured
separate locking device in a bow over 3 degrees unless otherwise
way prevent them from driving. Shearer equipped with two
towing winches or separate brake may not be ensured
separate locking device. Shearer can move
skid after scraper conveyor, only if it is equipped
mechanism which prevents it from falling from the conveyor track.

(3) The chain or rope and gripping device for moving the mining
combine must have a triple safety tension elements for travel
other mining and tunneling machines twice the relative safety
greatest strength exerted towbar.

(4) Elements locking device must have at least six times
safety due to the gravity component needed to arrest the mining
combine. Winches, pulleys and engaging portion of the locking device
must be designed with respect to the nominal capacity of the traction element. Anchoring
locking device must match the rated load of the traction member.
Must have three anchor elements separately attached to the locking device.
In the event of failure of any element must be closed down.

(5) When using a locking device with continuous braking must
braking force permanently show a value greater than twice the gravity component
which could cause driving the mining combine.
Accepted braking track, however, may be the most 0.4 meters.

(6) During the operation of mining and tunneling machines are not workers
linger dangerously close to the cutting machine body or in the area
potentially dangerous amplitude traction element.
When running these machines must first be heard automatically warning sign
significantly distinct from the operating signals and operating noise, and only after
least 5 but not more than 15 seconds may be to start the machine.

(7) The operation of mining shearer must pull the locking element
device is still tense and secured against accidental amplitude.

(8) During the operation of the mining combine with local control in steep seams
saved the operator is obliged to reside in a designated area where
not compromised shearer or falling rocks and from which
can safely monitor and controlled shearer. This space will determine
technological progress.

(9) When operating mining equipment with remote control operation
is obliged to remain in the place from which it can safely monitor and

Operate mining equipment. This site will determine the technological process.

(10) In addition to the obligations specified in § 226, the operator must inspect
tension elements, retaining their equipment and mooring in each half inning.

(11) Trailer features continuous miners and detention facilities
is obliged to check appointed officer in particular with regard to the set
safety at least once every two weeks.

§ 260
Mechanized reinforcement


(1) Mechanized reinforcement must provide protection against falling rocks and
safe passage under the joists sections, as well as access to the crew serving
controls reinforcement, mining machinery as well as other
device. This passage must be mined at a thickness of 1.5 meters
minimum width of 0.7 mA minimum height of 0.5 m in thickness over 1.5 m
minimum width of 0.6 meters.

(2) Levers hydraulic controls section of powered roof supports must be
off time control set to the zero position. Section mechanized
reinforcement can be controlled only from the secure area, from
common control block or blocks placed on sections
adjoining section that moves.

(3) Section mechanized support in steep seams must be equipped with a device that prevents
transverse and longitudinal movement of the joist. As
connecting element may not be used rope.

(4) Mechanized reinforcements for steep seams must be equipped with a through-hole
protection of the ceiling, the distance must not be greater than 10 m.

(5) For longwall faces equipped with mechanized supports must be at least one
serviceable alternative source of pressurized fluid or two separate
operable pump hydraulic unit.

(6) Mechanized reinforcement to contol the danger of rock bursts
must be equipped with a passive security workspace before
effects rockburst.

(7) powered roof supports used to provide space
mined longwall face with a thickness greater than 2.5 m must be equipped with pillared
restraints to be used against racking pillar.

§ 261

Trackless mining machinery

(1) Mining trackless machine must be equipped with two independent
braking systems, of which at least one is independent of engine operation.
Both brake systems must be independent of each control device and
must be operable from the driver's cab.

(2) Mining trackless machine must be equipped with two chock
against driving.

(3) The operation of mining machines bezkolejového
workers must reside in the range of loading or other working body of the machine.

(4) Trailer bezkolejového mining machine must have its own braking system
. Trailer for the transport of persons must be inrush braking system.
Section Two


Machines excavating

§ 262

Excavators and loaders

(1) The driver is obliged to observe the cut when digging and working platform and
monitor if there are no signs of any landslide masses.

(2) The determination of landslide danger, the driver must stop digging,
leave the machine in a safe place, warn vulnerable workers and the situation
report.

(3) Manipulate shovel over cab vehicle
is prohibited.

(4) The bucket can be cleaned only when the engine is switched off the machine and place
is no risk of landslide materials. Shovel when it must be asked and
have a closed valve. The driver is required after cleaning bucket
check whether a worker cleaning a shovel at a safe distance
.

(5) Suspension load and handling must be performed according to the manufacturer
machines.

(6) The operation of excavators and loaders that nobody is within reach
working body of the machine. Driver's assistant (oiler) can only stay
in places and under conditions determined by the driver or operational documentation. Of
designated place may leave only with the consent of the driver.
Beginning and end of their work must always tell the driver.

(7) Machines must be equipped with two chock against driving.

§ 263

Use earthmoving and construction machinery underground

The basement can be excavating machines are used only if they meet the requirements of this ordinance
.
Section Three


Machinery and equipment for mining transportation

§ 264


Machinery and equipment for vertical transportation underground and dipping Transport Workers rope


(1) Mining machinery and transport equipment for vertical transportation in the underground
must also comply with the requirements of a special regulation. ^ 21)

(2) Requirements on the door or fuel stations, cables, connecting devices
harnesses, sheave, driving track and signaling equipment for transport workers
rope on slanting roads designate organizations.

§ 265


Winches
(1) or winch drive for transport on slanting
traffic routes must have a retarder.

(2) The controller (switch) must be installed between the vehicle and transported
winch or motor station.

(3) The winch and the drive station must have a protective cover to prevent
limbs pulled in between the rope and the rope and drum or disc.

§ 266

Ropes and connecting devices for transport of materials

(1) Cable and connecting equipment used for the transport of materials must exhibit

A) trawl winches and looting at least four times the initial
safety due to the greatest tension winch

B) at least six times hoisting winches initial safety due
the greatest tension winch

C) in the case of fuel stations in the transportation endless rope
least six times the initial safety due to the biggest thrust of the power station
magnified by the bias of the rope.

(2) The rope must be postponed if it is by external signs clear that
its capacity significantly reduced, especially

A) if the wire outer layer weakened by more than half of its
average

B) increases markedly when the number of broken wires

C) When the total nominal cross visible broken wires on
ten times the height of the coil springs in any part of the rope
values ​​more than 20% of the total cross section of the supporting ropes,

D) in damage to the rope (loop knot embossed liner, etc.)
Which can not be removed (by shortening the rope, etc.).

(3) The coupling is not spontaneously detach and be connected to the cable harness
.

§ 267

Rope wheels and pulleys

Free hanging rope and pulley wheel must be secured against
derailment and 2 independent of each mooring.

§ 268

Gondola lift underground

(1) Documentation gondola cableway prepared in accordance with § 217 determines

A) deployment support rollers and their anchoring

B) drive type and location,

C) the execution of return and curved stations

D) diameter and type of rope

E) safety and signaling equipment.

(2) Lock the seat carrier or container and tow rope must
allowing slippage during transport.

(3) If the tow rope at the same time supporting, must have a seat or carrier
container carrier arrester to prevent driving over the support rope.

(4) Drive gondola station must have the automatic brake
which stops its movement even in the most unfavorable load.

(5) in the area where the cableway operator must roll if
located less than two meters above the tunnel floor, secured against accidental contact.
At the point of attack of the rope onto the pulley or pulley must guard and
necessary homing device.

(6) overhead cable reel on the serving station
must be secured so that it does not fall even in case of damage to the bearings or pivot.

(7) Recoil pulley tensioning device must be in extreme positions
prevented from getting out of its leadership.

§ 269

Mine rail and monorail locomotives

(1) Mine railway locomotive and shackles must have at least two independent
brake systems, of which at least one must be independent of the operating
engine.

(2) Suspended locomotive must have a speed limiter, which gives the
work safety brake when exceeding the speed limit.

(3) The effectiveness of the safety brake suspension locomotives must be such that
stopping distance not more than 15 meters and the delay was not more than 9.81
ms-second

(4) The efficiency of the service brake mining railway locomotive must be such that
to stopping distance not when transporting materials longer than 40 meters and at
transport people longer than 20 meters.

§ 270

Lifting carts monorail and their connecting rods

(1) Connecting rod must have at least four-fold safety relative to

Largest static load in cross tensile stress and buckling.
Eye and site links the eye to the carrier truck or a connecting rod must have at least six times
safety.

(2) Connecting rod for transporting persons must have an adjustable length, color
must be distinguished from the connecting rod for transporting materials and
not be used when transporting materials.

(3) The connection between the truck or suspended locomotive
must be secured against involuntary disconnection.

§ 271

Braking carriages monorail

(1) Construction truck braking must ensure its automatic braking
when exceeding the speed limit in both directions.
Truck brake shall be operable manually.

(2) Efficiency braking must be such that the stopping distance not exceeding 11 m
a delay in the carriage of persons shall not be greater than 9.81 ms-second

§ 272

Device documentation monorail

Device documentation monorail prepared in accordance with § 217 determines

A) the location of the track Excavation with respect to compliance with the stipulated
spaces and passageways

B) the type and placement of the hinge bearing tracks and the way to fix them in
Excavation,

C) security tracks against lateral and longitudinal displacement

D) deployment stops moving,

E) the type and location of the windlass or fuel station,

F) the method and type of label placement and signaling and intercom
equipment.

§ 273
Mining trucks


(1) Clutch or other connection devices mine vehicle for transporting materials
must have at least six times and safety for the transport of persons least
tenfold safety due to the largest static load
strength.

(2) The coupling device must not spontaneously disconnect.
Transporting passengers must use solid rods secured against involuntary disconnection.

(3) wagon with end walls, which can be used as well as manual transport
must have on both faces protected handle.

(4) Deformed or worn coupling device must be replaced.

(5) during machine transport must not be pushed cistern wagon or opened.

§ 274

Motor vehicles and motor trucks

The basement can be used in motor vehicles and motor trucks
only if they meet the requirements of this ordinance.

§ 275

Mine belt conveyors

(1) Conveyor belt underground use must be of a material that does not
spread of fire.

(2) Prior to the launch of the discharge conveyor belt, drive and return roller
must wipers, side covers and guards against drawing the limbs.

(3) joint conveyor belt must be adjusted so as not to endanger
workers and limiting debris to fall through.

(4) Suspension Suspension conveyor lines must have at least quadrupled
safety due to the largest static load.

(5) Automatically operated rig mining belt conveyors must
except § 219 also meet the following requirements:

A) before putting the conveyor into operation must be given a label denominated
least 5 seconds, which is audible throughout the length of the conveyor,

B) stopping the conveyor must be possible from any point along the conveyor
; locking cable must be accessible from design
conveyor and must be marked

C) it must be ensured automatic stop of the conveyor fail,
particularly at break and the belt slippage, overflow přesypných sites and
overheating electric motor

D) shall be signaled to a dangerous temperature drive and return stations.

(6) Mining conveyor belt for transporting persons must meet the following additional requirements
:

A) conveyor belt must have a minimum width of 0.8 m for the transport speed to 2.1 m
. s-1 and at least 1.2 m for the transport speed greater;
speed transmission shall not exceed 2.5 meters. s-1,

B) at the bow more than 6 degrees must have a conveyor drive brake
prevent accidental movement of the conveyor belt

C) conveyor belt must be at least ten-fold safety relative to
greatest tension in the belt

D) hanger for hanging conveyor lines must have at least six times
safety due to the largest static load

E) conveyor which has the facilities for transporting people across the dune, the

Be located at least 10 meters from the dune equipped with locking
roadblock that stops the conveyor when approaching people in closures. When
shuttles must be closures before and after transfer point.
Between the transport belt and the lower edge of the locking caps gap may be the most
0.2 meters

F) along the conveyor must be within reach of moving people blocking cable,

G) for passenger transport on the mining belt conveyer may be
downstream conveyors in operation, they are not designed for transporting people.

(7) The conveyor must be adjusted to avoid falls off
transported material and undesirable friction. In places where traffic
branch is higher than 1.4 meters above the floor or a mine tunnel floor must have
lateral protection.

(8) Sandhills and filling stations must be constructed so that the bulk height
minimized. Dunes drag conveyors must be adjusted to rubble
not bulldoze under the conveyor. Places creates dust must be fitted with a dust proof
device, which must be in operation during transport
muck.

(9) If there is a danger of tearing down the conveyor belt winds must be at
conveyor construction integrated roll bars or other suitable device
.

(10) In the stretching of the conveyor belt must have a rope and rope Joints
rope least double the safety with respect to the largest thrust
hitch.

§ 275a

Mine conveyors

(1) the signaling device must be equipped with conveyors that are not from the place
control overlooked. The label must read
least 5 seconds before the conveyor control point for propulsion,
return and tensioning conveyor station, near the dune
and other dangerous places. Accidental triggering of the conveyor must be prevented by blocking
.

(2) Stop the conveyor must be possible from any point along the conveyor
.
Section Four


Energy and other equipment

§ 276

Compressors for compressed air production

(1) The organization shall identify the engineer responsible for the condition and management
compressor operation.

(2) The conditions for the location and operation of the compressor in the underground organization determines
project and operational documentation.

(3) between the compressor and the air receiver or compressed air distribution system must be
shut-off valve.

(4) between the shut-off valve and piston or screw compressor must be
safety valve and turbo compressor or rotary compressor
check valve and relief valve.

(5) Turbocharger must have a device that alerts the operator
illegal raising the temperature of compressed air for engine and oil temperatures
and drop in oil pressure. To monitor the temperature of the compressed air
must be at suitable locations thermometers.

(6) In the multi-stage reciprocating compressor must be on the discharge side of each
grade pressure gauge and relief valve.

(7) The safety valve must be set so that after opening could occur
exceeded permissible operating pressure at rated power
compressor by more than 10%. The relief valve operator is obliged to control the compressor
nadlehčením at least once a week,
technician responsible for the condition and operation management of compressors
pressure at least once per year using the control manometer.

(8) on the discharge side of the compressor must be a barometer and thermometer.

(9) The intake air compressor must be filtered. The filters must be
non-combustible material.

(10) Highest temperature of the compressed air measured at the discharge area of ​​compressor
flange must not exceed 180 degrees Celsius. For compressors with
input up to 75 kW, the organization may authorize an increase in temperature to 220 degrees Celsius
.

(11) Water used for cooling the compressor, the intercooler and aftercooler
not contain flammable and toxic materials or mechanical
dirt. If the content of substances that cause water hardness must be
water is chemically treated. The maximum allowable temperature chemically modified
water is 40 degrees Celsius.

(12) cooling water flow from the compressor must be checked.

(13) The operator is obliged to discharge condensed water and oil
intercooler, separators, chillers and air tank in
deadlines specified operational documentation.

(14) In the compressor output above 1000 m3.h-1 must be monitored pressure

Each stage, temperature of the exit of compressed air, pressure oil
cooling water inlet and outlet and the operating data of the drive
device. The measured data must be recorded at least 2 hours
unless they are measured and recorded automatically. For other
compressors determine operational documentation of the type of monitored data, deadlines
survey and the manner of their records. The monitored data may not be
recorded if the compressor meets the requirements of § 219.

(15) The compressor, which meets the requirements of § 219, the designated officer
obliged to check the function of automation and operational security
system within the time and in the manner specified operational documentation.

(16) Individual parts of the compressor and its accessories can be
removed only if there is no overpressure.

§ 277

Separators, chillers, air tanks and connecting pipes

(1) The volumetric compressor or a group of related volumes
compressors must be built condensed water separator and oil
air tank, or even chillers. Separator, air tank and aftercooler
must be at the lowest point of the drain.

(2) and separator aftercooler must be at least cleaned once a year.
Tank and the respective connecting pipes should be cleaned at least once every 3 years
.

(3) If there is a positive displacement compressor pipes and vents
diameter greater than 200 mm, it must be inspected at least once per year;
Thickness sediments over 2 mm pipes must be cleaned.

§ 278
Compressed air distribution


(1) If the temperature of the compressed air before entering the mine more than 60 degrees Celsius
organization is required to determine the measures to protect workers against burns
.

(2) Seal conduit between the compressor and the tank and where the temperature
compressed air is greater than 60 degrees Celsius, must be of non-combustible material
. Perturbed seals must be immediately replaced.

(3) At the lowest points of the main air duct and, if necessary, even
branch to consumers must be built traps, from which it must be
condensed water and oil discharged. Separators must also
individual branches of the main duct at the pit.

(4) hose and its connections with the piping and equipment must conform
maximum allowable working overpressure and must be placed so that
not create sharp bends. Before connecting to the machine hoses
purged with compressed air.

(5) Hoses for supplying compressed air to the movable machine
must be secured against pulling out of the joint.

(6) Work on Compressed-air Lines under pressure is forbidden. When working on
Compressed-air Lines must be relevant shut-off valves
secured against accidental opening.

(7) Purge If the compressed air pipes, hoses, adapters or
other components must proceed so that nobody is endangered.

(8) The compressed air distribution map ^ 7) must be marked
length and pipe diameter and spacing of pressure vessels and valves.
The compressor must be compressed air distribution scheme between the compressor and
vessel.

§ 279

Air and gas engines

Air and gas engines must be secured against the build up of foreign
bodies into the engine from exceeding the rated speed.

§ 280

Compressors for natural gas and manifolds

For natural gas compressors and manifolds shall apply mutatis mutandis §
276-278, with the manifold gasket must be of non-combustible material
and compressors must be fitted

A) automatics, to prevent exceeding the maximum working pressure
pressure side and lower operating pressure on the inlet side underneath
specified limits,

B) covers of fireproof material

C) automatic extinguishers.

§ 281

Boilers and accessories

(1) boilers to gas and liquid fuels must be secured so that there
for automatic interruption of fuel supply to the burner while being changed
operating pressure of the fuel and combustion air.

(2) boiler with induced draft gas heating, liquid fuel or coal
powder must be equipped with a safety device that the illicit
change in fuel supply or interruption flue gas automatically stops the fuel supply
to the burners.


(3) boiler burner for burning gas or liquid fuel must be equipped with a safety device
a boiler with a burner for combustion of coal powder
device for securing stable combustion.

(4) firebox door and viewing window into the firebox behind
boiler operation is secured against opening due to pressure in the combustion chamber
.

(5) Supply of water supply must be made so as not to cause rapid cooling of the walls
pressure unit.

(6) boiler with mechanical grid or powder heater must be equipped with a dust-free ash remover which assures
device.

(7) Ash removing equipment can be repaired only when the device is off
operation and only under constant supervision.

(8) Inspection at the dust-removing door must not be opened unless the cap is closed
svodkách.

(9) boiler located outside the boiler room must be protected against manipulation by unauthorized persons
.

§ 282


Steam Boiler
(1) Steam boiler must be equipped

A) at least one gauge indicating the maximum allowable
overpressure, water loop and a three-way valve or a valve

B) at least one straight watermark indicating the lowest allowable
water level in the boiler (once-through boiler outside)

C) pressure relief device

D) fill and drain valve,

E) power devices

F) the bleeder valve.

(2) The facilities referred to in paragraph 1. b) and d) may not be equipped
boilers for gaseous and liquid fuels, which have lasting liquid refill
hermetically sealed in the boiler body.

§ 283
Fluid boilers


(1) Liquid boiler must be equipped

A) open expansion tank or other safety device

B) fill and drain valve,

C) for boilers with a rated power of 50 kW and a pressure gauge and a thermometer.

(2) The boiler must be equipped with a device that automatically eliminates
exceeding the maximum permissible fluid temperature; boiler with manual stoking
be used for that purpose, equipped with alarms or have
permanent attendance.

(3) Bleed and expansion tank overflow pipe may terminate
to the outside.

§ 284

Work inside the boiler

(1) Prior to the entry of workers into the boiler boiler must be safely disconnected from neighboring
boilers and sampling line; other pipelines leading into the boiler
must be closed and secured.

(2) Inspection and work in the boiler or furnace must be conducted under constant supervision
worker outside the boiler. Before closing the lids, doors, etc.
Before putting into operation is necessary to ensure that the boiler or furnace
None.

(3) Before entering the pressure unit boiler or furnace must be
examined whether these spaces are well-ventilated and emptied, and that the danger
furnace slag or ash fall deposits, possibly
masonry.

(4) of the boiler equipment, in which the work must be placed
security table.

§ 285
Boiler


(1) In the boiler room must be operational procedure and diagram of the power and steam
pipe or conduit to supply fuel with marked
length and diameter of the pipes.

(2) The boiler room must be a sufficient supply of air for combustion and ventilation
.

(3) On the door to the boiler room must be the security table.

(4) Boiler with a footprint greater than 150 square meters
must have two escape routes, one of which shall lead directly into space.

(5) Popelná must be equipped with a supply of water to the ash and cinder
výsypkám and the seals on the cinder and ash dumps with
safe operation and must be adequately ventilated.

§ 286

Piping hot water and steam

(1) pipes for hot water and steam § 222 applies with the following additions:

A) the pipe must be stored and maintained so that it could adapt
temperature changes

B) must be avoided by people burning pipeline.

(2) Work on the pipeline, in which hot water or steam, is prohibited.
While working on pipes must be appropriate shut-off valves
secured against accidental opening.

(3) When used, the vapor pressure lower than that in the boiler must be installed into conduit
pressure reducing valve and into the delivery duct with the lower pressure

Safety valve which corresponds to the maximum allowable pressure in this
part of the pipeline. Method and deadlines for reducing inspections and safety valve
determine operational documentation.

(4) Where appropriate, the steam pipes must be installed separator
water.

§ 287

Refrigeration equipment mine air

(1) The organization shall identify the engineer responsible for the condition and management
operation of the cooling device of mine air.

(2) Documentation refrigeration equipment prepared in accordance with § 217
also determines the location of the cooling unit with respect to the management of workings, mine ventilation
and connection to energy and water resources.

(3) cooling equipment in the underground can be used only non-toxic, non-flammable and non-explosive
refrigerant.

(4) Exhaust pipe safety valve must be tight, protected from freezing and exhausted
into space so that workers are not threatened by the blast
refrigerant.

(5) Cooling equipment mine air must be made and maintained
to prevent leakage of coolant. The operating rules of the cooling equipment must be designed
deadline and checks the safety valve and refrigeration equipment
potential leakage of coolant.

(6) Store refrigerant in the underground is prohibited.

(7) For refrigeration equipment must be first aid kit, two pairs of rubber gloves and two
tight goggles. Operating Procedure shall determine their use.

(8) Cooling equipment is obliged to inspect the designated officer
least once a day and check the designated technician at least once a week.

§ 288

Unsteady cooling device of mine air

(1) Automatic operation of cooling equipment is permitted if the device
meets the requirements of § 219 and if

A) Automatic turn off device when exceeding the set values ​​

First refrigeration compressor discharge pressure,

Second suction pressure of the refrigerant compressor

Third pressure oil to lubricate the compressor

Fourth chilled water temperature at the evaporator outlet for indirect way
cooling

B) cooling equipment is equipped with a thermostatic expansion valve,

C) signaling operation is led into the control room or place a permanent
service.

(2) on the cooling equipment must be marked with the type of refrigerant used.

§ 289

Stationary refrigeration equipment mine air

(1) Stationary refrigeration equipment mine air with an indirect manner
cooling must be placed in a facility that is not used for any other purpose
.

(2) Exhaust pipe safety valve must be routed into
průchodního větrního current. Intensity průchodního větrního
current must be such that the largest amount of coolant discharged
relief valve did not decrease the concentration of oxygen in the mine air below 19%.

(3) Excessive refrigerant leak or accident must be allowed off
refrigeration equipment from the site in vtažných winds offsite and
relevant electrical station.

(4) At the entrance to the establishment of refrigeration equipment must be marked with the type of refrigerant used
.

§ 290

Drills and hammers

When using a drill and hammer drill is prohibited

A) guiding hand drill or a drill rod,

B) using electric drive to rotate the drill that got stuck in the borehole,

C) drilling with a blow drill cuttings and had no disposal of dust

D) anti-dust disconnect device.
PART NINE


Walking, transport and storage
Part first


Paths for walking and transportation

§ 291

Paths for walking

(1) Paths for walking paths are in the mine workings and the locations on the surface
which are designed for walking.

(2) Paths for walking must be free of obstacles, drained and maintained
to walk them to be safe. Paths dipping greater than 30 degrees
must be fitted with handholds and footholds, or stairs. For travel in
mine workings with an inclination greater than 45 degrees also specific
prescription. ^ 21)

(3) If there are paths for walking underground
simultaneously transport routes must be defined on these trips walking time workers.

(4) Walk by other routes than routes for walking or transport pathways
beyond the period specified in paragraph 3 may only supervisory authorities and other technicians
(§ 7 para. 5) and the workers who have to get
from the supervisory authority command. On road transport, may stay longer than

Necessary. Before meeting with a moving vehicle they are required to timely
retreat to passing traffic on the road (§ 292), or in another safe place
.

(5) The period set aside for walking in paragraph 3 must be on the road traveling
mechanical transportation stopped.

(6) joiners workings, which may not be used for walking, must be labeled
bans or be prevented from entering into them otherwise
way.

(7) between vehicles are allowed to pass through only when standing between them and the
direction of possible movement distance of at least two meters.

(8) Paths for the exit of workers from the risk of mine accidents
(escape routes) must be marked with an indication of the direction and retreat, where
requires emergency plan is putting distance.

(9) Paths for walking at a height greater than 1.5 meters and travels along
dangerous pits must have a free side railings.
Railings must be solid and well-grounded. Top handle must be secured in
height of 1.1 meters. Unless the fence railing used with a full wall
(sheet, wire, sheeting with gaps most 0.2 meters, etc.)
Should be about half the height attached additional longitudinal rod.

(10) If the path to walk crosses over another road or a place where you can stay
workers must have a protective rail at floor height of 0.1 meters
least, if not objects falling from it prevented otherwise.

(11) Holes and depressions on the road to walking must be covered or
secured so they do not fall persons or objects.

§ 292

Dimensions paths for walking, transitions and passages on roads

(1) Paths for walking must have a section with a height of at least 1.8
underground subway, on the surface at least 2.1 meters and a width of 0.75 meters. There, where
due to the effect of mountain pressure does not meet this requirement,
must immediately proceed to recover the designated section.

(2) If the underground while walking haul rope must be
gait of a separate department with a cross section of a minimum height of 1.8 meters and a width of at least 1
meter, which must be separated from transport routes so
to avoid danger to personnel or cargo vehicles.

(3) Passages between the stationary machine must have a section with a height of underground
least 1.8 meters, on the surface at least 2.1 meters and a width of 0.6 meters
.

(4) passages on roads equipped with rail lines
must have a height of at least 1.7 meters underground, on the surface at least 2.1 meters minimum width


A) 0.6 meters on at least one side of the transport route

B) 1 m in the platforms along the entire length of the train on one side of the track,

C) 0.6 meters per nárazištích marshalling yards and adjacent on both sides
tracks.

The provisions of this paragraph shall not apply to the passages on roads
equipped with rail tracks on the track 900 and 1,435 millimeters.

(5) passages required in Subsection 4. a) does not need to be built,

A) if a train running on time signaled steady
signaling device on the track, so that individuals can in time to move away into an alcove or other
mining work. Niches must be built on the side of the mine and
must have a minimum height of 1.8 meters, a minimum width of 1 m and the smallest
depth of 0.8 meters; the distance between the recesses must not be greater than 50 meters
or

B) when it is on these lines obviate any walk in time when
thereon or when transporting them standing vehicle or

C) when vícekolejových lines to ensure that all the tracks are not currently
was filled with cars.

(6) for passage on roads equipped with suspension
tracks, paragraphs 4 and 5, the dimensions of the passages must be respected even when
usual fluctuations vehicles transported. Normal fluctuations of the vertical plane
counts 10 degrees, but at least 0.1 meters.

(7) passes over the conveyors in underground stopes and working faces apart,
must be made the transition bridges a minimum width of 0.6 meters.
Transition bridges shall be equipped with handrails and height above them must be at least 1.2 meters
. For conveyors to the width of the drive means 800
millimeters may be transient bridges interrupted when the overhead
minimum height of 1.6 meters and are equipped with handrails.

(8) crossing over conveyors positioned on the surface must be made
under a special regulation. ^ 69)


(9) Places scale sections paths for walking, must be clearly labeled.
^ 70)

§ 293

Bridges, ramps, walkways, scaffolding and ladders for walking

(1) Bridges, ramps, walkways, and scaffolds for walking must have a solid and level
floor and must be technically solved at the most anticipated load.

(2) Bridges, ramps, walkways and scaffolding must be checked at
specified deadlines.

(3) The ladder must be secured against slipping or transporting.
Upper outlet opening or platform shall extend at least 1.1 meters or
must be fixed to this height handrails. Over the rungs must be free space
least 0.18 meters.

(4) Using the overhanging ladder or ladder gangway
is prohibited.

(5) Ladders shall not be used for taking out or endure loads of
weighing more than 20 kg.

(6) At the same ladder must not act or descend simultaneously
2 or more workers.

(7) If necessary ladder set up must be both parts securely connected. In
juncture may not be inclined ladder or distance between rungs
changed.

§ 294
Transport routes


(1) Transport routes are routes in mines and those places on the surface
which are intended for the transport of persons, machines or materials. For the horizontal transport route
consider dipping into 35 mm.m -1. With more inclined to 45 degrees
including transport routes are dipping. Transport routes
dipping greater than 45 degrees (pits, chimneys, shafts, etc.) Are considered
vertical. ^ 21)

(2) Traffic routes must be maintained and labeled with ^ 70) so as to match the operating conditions
and transport them was always safe.

(3) Sections of traffic routes, which serve as a platform must be adjusted
invert or platform.

(4) Traffic routes, which cross or converge
must be equipped with safety devices and must be addressed such measures to
avoid a collision. Security Devices must be designed
so that even when failure to ensure the safety and operation.

(5) narrow gauge railway crossing on the surface of the mine with communication
road traffic vehicles must be marked with traffic signs. ^ 83)

(6) passes through if the transport route over another road or workplace
must be ensured that nobody is endangered means of transport
falling objects or materials.

(7) On roads with uninterrupted service, through which it must pass
must be established crossings (bridges, underpasses, etc.).

(8) Traffic routes, which are not used to walking during transport,
must be on areas access to designated entry ban or
must be prevented from entering into them in another way.

(9) On the roads to transport the rope during transport should not impede
workers, if this route does not satisfy § 292 paragraph.
Second

§ 295

Transportation routes with rail lines

(1) The introduction of mechanical transport must be a railway track ^ 71)
znivelována. Within a further readjustment shall be determined by the state
transport routes.

(2) End of rail tracks must be secured against driving vehicles.
Rail lines designed for machine transport must be marked or labeled, tables
.

(3) Language switch during mechanical transport must be equal and be in extreme positions secured
weight heat exchanger, spring or other
way. Remote-controlled crossover must have optical control position.
Turnout may be placed on crossing the railway track.

(4) The correct position of the fifth and přesuven must be lockable.
Lines on the machine must not be used transportation platforms, turntable or traverser.

(5) In places where the mine cars pushed into the arc of a track
shunting or other device, and which could derail must be
inner side of the curved track equipped with a guide rail.

(6) Paragraphs 3-5 do not apply to rail tracks on the track 900 and 1,435 millimeters
. ^ 72)

§ 296
Location
rail tracks and the operator compartment

(1) Among the widest parts of the passing vehicles on parallel rail lines
must be a gap of at least 0.2 meters.

(2) The gap between the reinforcement kits, buildings, equipment or stored
objects and outline largest vehicles including cargo must be at least
0.25 meters.

(3) On roads with rail tracks, where all lines

Tend to be filled with mine cars and where the mine cars connected, or disconnected
hand, must each have a railway track on one side of the operator compartment
to a height of 1.7 meters underground at least on the surface at least 2.1 meters
a minimum width of 0.6 meters.

(4) of a track gauge of 1435 mm and 900 must be placed
under special regulations. ^ 72)

§ 297

Dipping Security Infrastructure with rail lines in transport rope

(1) On slanting road transport with rail tracks in the transportation lifeline
podstavníkem excluding transportation, must be moveable barriers under the gridiron,
on foot and in places connecting and disconnecting cars to the rope. The drifting
inclined slope determines the distance from the face movable barriers
technological progress.

(2) under the gridiron barrier must be placed as far away from the gridiron, when
closed curtain may be dipping rail track running all
simultaneously transported by trucks. Location of other gates will determine traffic rules.

(3) barrier under the gridiron must be operable only from the operator
windlass or fuel station. The operator must have an unobstructed view of the place
connecting and disconnecting cars. If the views of this site is not possible
must be between the place of connecting and disconnecting cars and service station
ensure appropriate way of understanding. Other barriers dominate
appointed staff.

(4) At the base must be established to operate a shelter from which it is possible to give
label.

(5) On slanting road transport with rail tracks in the transportation lifeline
excluding transportation podstavníkem must use the self-acting
catching device. This requirement may be waived if the rope and
all connecting devices have at least ten times the initial
safety due to the greatest tension winch or fuel station.
The detention center must ensure their execution trapped car
against overturning or derailment.

(6) When transporting the incline greater than 15 degrees cars must be equipped with a safety device
against overturning.

(7) with a ladle podstavníkovou transport must be equipped with protective
device, which prevents the insertion of cars on road transport dipping
before the podstavník parked and secured against movement. On
podstavníku be locking device for mining vehicles.

(8) Transports If dovrchního digging the mine through a pulley
determine how to ensure safety and operation of technological progress.

§ 298

Traffic journey monorail

(1) The monorail can be equipped with only the transport routes, where
capacity reinforcement and its stability, or other attachment bearing hinges
tracks is adequate with regard to the means of transport and loading
transported materials.

(2) Turnout turntable and monorail must be firmly connected
adjoining sections of line and hung on hinges separate reinforcement.
Parts Manually operated slide switches and turntable must be in extreme positions secured against
change position and must conclude impassable branch lines.
Switches and turntable must prevent rolling off the vehicle and must be optically controlled
of control place.

(3) At the end of the track monorail must end stop.

(4) Turnouts monorail tracks must be operable from the operator
(driver's cabin, the cabin crew habitat vrátkaře etc.).

§ 299

Location
monorail tracks
(1) On roads with monorail must be observed gaps
under § 296 paragraph. 1 and 2 and at the usual fluctuations vehicle (§ 292 paragraph.
6).

(2) The gap between the lower edge of the vehicle and the tunnel floor must be at least 0.1 meters
.

(3) When crossing over other transport facilities must be
gap between the lower edge of the vehicle and the most protruding portions of the conveying device at least


A) 0.1 meters if the transport equipment during operation monorail
not running,

B) 0.6 meters if the transport equipment during operation monorail
is running.

(4) In handling areas, including loading and unloading stations
must be full-length, on at least one side of the space
operate a minimum height of 1.8 meters and a width of at least 1 meter.

§ 300

Movable stop monorail track

(1) On track monorail, excluding transportation endless rope must stop moving



A) under the gridiron and in places connecting and disconnecting cables,

B) loading, unloading and reloading stations and places
coupling and uncoupling of vehicles

C) of the department during the excavation of inclined slope away for
technological process mined the mine.

The places referred to in point b) the organization
horizontal line sections identify other means to ensure vehicles against driving.

(2) Moving stops must be constructed and located so that the operator could
from his station to manage and control setting breakpoints. When
transport hanging locomotive must stop moving and controllable
hanging from the locomotive.

(3) movable stop under the gridiron at the beginning of slanting lines
must be positioned so that when the stop could be closed on slanting tracks
running all at once transported vehicles.

(4) movable stop under the gridiron must be operable from the station
winch operator or fuel station or a suspended locomotive.
If you can not control settings from the operator stops the winch
or fuel stations must be designed to control worker from a safe place
. In this case, it must be ensured reliable communication
this employee runs a winch or fuel station.

(5) On the lines monorail transport endless rope must be placed
stops moving, so to avoid dangerous driving
vehicles.

§ 301

Transport routes with conveyors

(1) On roads with underground conveyors must be

A) gap between the conveyor structure and the reinforcement on the side walk
least 0.8 meters, on the other hand at least 0.2 meters,

B) space above the upper branch of the conveyor belt at least 0.6 meters, while
passenger transport at least 0.8 meters,

C) the gap between the lower strand of the conveyor belt or rotating parts
tunnel floor and at least 0.2 meters,

D) the height of the transport branch of the belt above the tunnel floor or floor in passenger transportation
less than 1.4 meters.

(2) The gap between structures parallel conveyors in underground
must be at least 0.8 meters.

(3) The gap between the most protruding part of the vehicle or rail transport and
hanging conveyor structure must be at least 0.2 meters.

(4) The provisions of paragraph 1 point. a) and b) applies to transport routes with
scraper conveyor trough or kits, which for more than three months
translated.

(5) Conveyors for roads on the surface must be placed
special regulation. ^ 69)

§ 302

Transport route for trackless mining machinery, construction machinery, motor vehicles and motor

trucks
(1) The gap between the reinforcement kits, buildings, equipment or stored
objects and outline bezkolejového mining machinery, construction machinery,
motor vehicle, motor truck cargo or cargo must be at least 0.6
Metres. If no driver or person being transported protected
construction machines, the gap must be maintained by these people.

(2) Measures to ensure the safety of people before couvajícími machine determines
traffic rules.

(3) Dump sites must be protected from overrunning machines into the unloading
(stop, a raised edge being poured, etc.). The area around the discharging place
must be sloped to výsypnému place. The underground places must be constantly
illuminated on the surface only in dark or poor visibility.

§ 303

Transportation routes for transportation of gravity

(1) Chutes and gravity pipelines to be constructed, fitted and mutually
connected so as to prevent them from clogging fluctuations and conveyed
masses.

(2) Hole for feeding fuel into the chute, gravity piping and tank
must be equipped with a device capable of stopping the flow of fuel.
Drain hole slip, gravity piping and tank must have a reliable seal.

(3) The drive and return stations poppet calipers must have two wearing
independent anchoring against driving.

(4) If the drive station poppet caliper directly associated with first
trough must be movable part between the drive station and the first chute
covers the protective sheeting.

(5) between the brake and the crown pillar must be left lane wide
least 0.5 meters.

(6) Equipment for the transportation of gravity must be modified so that
not endanger workers falling materials.


(7) A service of the equipment for the transport of gravity shall be
lit and positioned so that the operator is not endangered conveyed
masses.

§ 304

Transportation routes for transportation gondola lift underground

(1) The transport route with a gondola lift has to be a gap

A) the reinforcement kits, buildings, equipment or stored objects
most salient parts transported container load or persons
least 0.6 meters, while the transverse pivot 10 degrees; a person must consider
width of at least 0.6 meters.

B) the lowest part of the shipped container or burden rests
foot tunnel floor seats and at least 0.2 meters.

(2) platforms shall be a space with a cross section of a minimum height of 1.8
meters, a width of one meter and a length of 3 meters.

(3) In areas crossing over other transport facilities must be respected
spaces under § 299. 3rd

(4) When the entire length of haul roads must be audible sound
label indicating the start of the movement. The range of persons carried must be
locking cable to stop shipments.

(5) When using the seat ingress and egress for equipment operation
allowed only in speed of 1.5 ms-1. When using detachable seats must be on the platform
distance label.

§ 305

Tours roadways

(1) Transport routes and their equipment are required to be inspected regularly
appointed staff. During inspections must also be verified functions
signaling and safety equipment. Deadlines, manner and extent of inspections
determine traffic rules.

(2) before transporting workers must be the state transport routes
platforms including inspected at least once a day.

(3) railway infrastructure and its equipment must be inspected prior to commencement of shipment
in the place where the incident occurred, and after such
work that could affect traffic safety.
Part of the second

Transport


§ 306


Right hand
(1) Manual transportation vehicles and mine carts monorail is allowed to
horizontal transport routes; on slanting roads is
right hand only allowed mining trucks at the bow to 50-mm.m
1 to 50 meters, with a larger bow, most mm.m 85-1, a distance of 20 to
Metres.

(2) ride on a mine car or truck monorail, walk in
traffic in front of them or let them go free is prohibited.

(3) Mine cars and trucks monorail can be transported only
individually. The distance between the individually transported mine cars or trucks
monorail outside the ladle and charging and discharging
station must be at least 20 meters.

(4) for wind and dam door in curves where visibility is not free, and at intersections
putter is obliged to drive slowly and in addition to calling himself
alert, unless other appropriate warning signs.

(5) Mining wagon or trolley monorail can only push.
During transport to the slope mining truck can only drag.

(6) Individual mine cars, trucks monorail or disconnected parts
kits may be forced away from each other only when they are at rest, and it just
lever or by grasping the side.

§ 307

Machine transportation

(1) The introduction of mechanical transport fuels approves the designated officer.
Introduction of passenger transport racing down approves or persons authorized by them.

(2) The organization shall determine the technique or techniques
responsible for the management of installation, operation and maintenance of various types of machinery
transport. These workers must have at least completed secondary vocational education
machine direction and at least two years experience.

(3) Paragraphs 1 and 2 and § 308-312, § 317 paragraph. 1 and § 320 does not apply to
transport to rail gauge railways 900 and 1435 mm. ^ 72)

§ 308


Traffic Regulations
(1) For machine transportation organization issues a transport order, which must determine

A) infrastructure, machinery and equipment,

B) marking transport routes (brand reduced before interest, switches,
intersections, dangerous places, etc.) And location of signaling devices

C) space for loading, unloading and reloading materials, sorting, and shut
reversing vehicles, etc.,

D) transport time and time allocated for walking,

E) leave the burden of individual transport equipment

F) speed limit transportation,


G) instructions for connecting and disconnecting vehicles and their
hedge against unwanted movement, or for loading, unloading and reloading
masses

H) the method and the use of labels, their meaning and method of communication
attendants,

I) safety and operating instructions (for concurrent transport, walking at
current transport for transporting tools and objects, transportation
conductor etc.)

J) measures when transporting explosives

A) measures during transport of specific loads and in accidents on transport
way

L) deadline, mode and extent of inspections of transport routes and their equipment,

M) the scope of inspections of the transport equipment before shipment.

(2) Traffic regulations for the transport of persons must next determine

A) routes for the transport of persons

B) deployment platforms

C) the time allocated for transporting people to work and back,

D) rules of behavior of people in transit,

E) the number of simultaneously passengers and speed of transport,

F) the responsibilities of crew and supervisors and labeling supervisors

G) the conditions for simultaneous transport of tools and objects.

(3) Traffic Regulations for special transportation must next determine

A) way of handling loads and loads of special way of ensuring
in a stable position, even during transport,

B) placing a special burden on the vehicle so that its
center of gravity as low as possible and as close to the middle of the vehicle,

C) with regard to the status and conditions Infrastructure maximum allowable number
vehicles in the kit at a special transport on the monorail
maximum authorized mass transport sets and the number and type of braking cars in
depending on traction the strength of the traction vehicle, the biggest bow hanging
track and permissible loading of reinforcement mine work,

D) binding, or attachment points, and for safely storing and tying
loads of special means of transport to the determination of gravity
transported parts or components,

E) the number of persons in the transportation and endangered places (§ 17 para. 2)

F) slings and the place and method of deposit, or hanging
of lifting beams and slings for when they are not used
conditions for their postponement (§ 266 paragraph. 2) and the conditions prohibiting
their use.

(4) Traffic Regulations for special transport by overland rail system must next determine

A) the method of positioning and anchoring ground railroad and its implementation, especially
with respect to changes of direction or bow mine work,

B) the maximum permissible specific load overland track and its individual
parts or components within the carrying capacity of the invert,

C) the provision of transport elements against accidental disconnection.

(5) Traffic Regulations for special shipping skid must next determine

A) how to connect the tow rope to the transport platform, or to
conveyed special burdens and the type and design of harnesses

B) Provision for transportation through the sudden change of direction in the vertical plane
Infrastructure and transportation in the curves.

(6) Traffic Regulations must be displayed on platforms at stations
operator in draws, by the garage and on parking places.

§ 309
Obligations of the driver


(1) The driver is required to operate the vehicle from his post.
From a moving vehicle must descend.

(2) The vehicle must remain on the transport route unattended unless
secured against putting into motion.

(3) The driver is required when driving track infrastructure. If there is a danger
must reduce speed or stop. If you see
workers or other vehicle is required to dim the light, giving
warning sign and adequately reduce speed. If the driver meets
workers who have no opportunity to retreat to safety, or if the traffic on the road
obstacle is obliged to stop in time. The ride may
continue until then if it can convince that another ride does not endanger anyone.

(4) In the basement is obliged to warn the driver before starting
journey before entering blind spots, wind dam door
other bottlenecks, and the entrance to the platforms and stations. Prior to these places
and handling marshalling yards, platform and loading, unloading and loading station
is obliged to adequately reduce speed.


(5) The driver must not leave the driving to another person, except persons who
Breaks in command of an organization. The driver can afford carpooling
worker only for those vehicles, which are designed to
manufacturer.

(6) When starting the driver is obliged to provide a vehicle set in motion
slowly and smoothly.

(7) If the conductor or a staff member designated to handle vehicles traveling alongside
sets, the driver is required to drive a maximum speed of his gait and
must follow him.

(8) The driver of a vehicle with electric drive is required before handling
trolley collector or before connecting or disconnecting the supply
cable, turn off the main switch of the vehicle.

(9) expressive locking elements and hinder a counter except
emergency braking is prohibited.

(10) The driver of the locomotive shall also be familiar with the records of the state
locomotives and transport routes. At the end of the shift is obliged to make a record of the condition
locomotives.

§ 310


Signaling equipment
(1) signaling devices must be configured transport machine once
operation of transport equipment can not reliably communicate with staff
involved in the transport. During transport conveyors must be signaling each
facility is constructed, if conveyors longer than 15 meters and their
operation may be at risk workers.

(2) signaling device shall be provided and positioned so that
reliable and its control was not associated with danger.
Must also be ensured readability of labels for multiple modes of transport on the one
transport route.

(3) For the double driving station must Sound label vary significantly.

(4) U-signaling devices must be placed in the table with the meaning intended
label. The label "once" can only be used as a sign to stop
.

(5) Maintenance of transport equipment is required prior to shipment in
inning to make sure the proper function alerting device.

(6) before transporting cable operator must put a label on
place where it is transported, and wait on the return label.

(7) Transport way with transport rope must be equipped with such a device
warning signal to any destination of transport routes could be put
label to stop traffic. After the entire length of haul roads must be
audible acoustic signal indicating the start of the movement.

(8) The label must be clearly audible and platforms from which
are given.

(9), the operator can put the device into operation soon after 5 seconds and
within 30 seconds of receiving the label.

(10) Manual label is given on the surface for good visibility
developed a red flag, in other cases the lamp with a white or yellow light
. The significance of small label is shown in Annex no. 1, which is
part of this Decree.

§ 310a

Traffic signals and demonstrate

(1) To secure the transport route to transport locomotive must
locations designated by this decree established label or show.

(2) The shape, description and color of a traffic signal is carried by
Annex no. 2, dimensions and finish of each label including the shape and placement of symbols
according to Annex no. 3, which are part of this Decree.

(3) Touch showcase (eg. Hanging chains or straps) to establish there
where environmental conditions and prevent good visibility or detectability
label or at the entrance to the constricted sections
transport routes. Touch up the show at least two pairs of distant
apart 2-3 mo width equal to the width of the locomotive, wagon for transportation of persons, etc.
.

(4) The label "Warning" is placed

A) where the train braking on the approach to the terminal station, hinting and other
handling spaces

B) before the running of the train marshalling cars and hopper loading dock
device

C) where the transport route operates, with regard to the length
braking distance trainsets.

(5) Label "Reduced cross" or "narrowing of the"
must be placed where it is not complied with cross traffic routes, particularly prior Barrier
door or wind or directly on them and places chute | || device.

(6) The label indicating the intersection of lines, points, curves, and boarding

Outlet station must be placed before traffic sites designated
traffic regulations. Organization provides that switches and turns must be
with regard to safety and traffic flow identified.

(7) Label "Be the warning signals" must be located where the
performs work on the transport route in the distance specified traffic regulations.

(8) The label "No entry" concludes routes or stretch
for any mode of transport. In conjunction with the table with text
can also restrict traffic on the transport route to the designated (defined)
way traffic.

(9) The label "Námezník" is placed on marshalling yards, rail transport cars, the
transfer stations and on tracks intended for parking of wagons.

(10) Label "Canceling previous label" defines the end of the commands and prohibitions
warnings given labeled, Nos. 1 and 5 of Annex No. 2.

(11) Labels for trolley transport equipment is placed on the overhead lines
.

§ 311

Joining and separating vehicles

(1) Manually connecting and disconnecting can only be stationary vehicles
hanging rail and transport, and only after consultation with the employee, who would
could be set in motion. Manual disconnection for the movement of vehicles is permitted
only if a suitable device eliminated the need for tilting
worker between the vehicle and the possibility of rollover worker.
In no case shall workers entering the mine cars or
among them lean.

(2) Coupling and uncoupling trailers nekolejových surface
must be carried out under a special regulation. ^ 73)

§ 312
Transport people


(1) The organization is obliged at the beginning and end of every shift to ensure the machine
transporting employees to work and back, if the length of a continuous stretch
Infrastructure greater than 1.5 kilometers or dipping cant transport
paths greater than 50 meters and if in a given sector for more than 2 months
carry at least 24 employees in one inning. For this
transportation organization is required to define the period in which it is at the same
transport route and transport routes to follow
prohibited any other transportation.

(2) When the entire length of haul roads must be possible exit from the vehicle
resource.

(3) The supervision during transport workers must be designated supervisor, who
performs its function in the entry and exit of workers.
Supervisor functions can be associated only with the function conductor.

(4) In addition to time allocated to transport workers to the workplace and back
person may be transported only under the conditions specified in the transport order.

(5) before transporting persons, the driver is obliged to ensure that the traffic on the road
No faults were detected, or whether the defects found
already been removed.

(6) For each kit must be determined crew.
Crew started to set and the last to a place from which it can control signaling, possibly
braking device.

(7) Boarding of the train and out of it is permitted only on platforms
after the stop of the vehicle.

(8) When driving, a person must not lean out of the vehicle or any objects sticking
. In the vehicle they are required to take such a position
that no part of their body does not exceed the outline of the vehicle.

(9) The conditions for the transport of persons inclined rope on roads,
and the manner and time limit controls transport routes and equipment will determine
racing pit or persons authorized by them.

§ 313

Transport of materials and objects

(1) materials and articles shall be stored on the vehicle so that when
loading, reloading, transporting or unloading their
prevent unwanted movement.

(2) Inlaid materials and articles shall be stored so as to not interfere in transit
sectional transport route and at the same time
no danger of tipping, collapsing or falling.

(3) In the manual loading and unloading the vehicle must be secured against unwanted movement
. At the vehicle is in motion is prohibited by hand and dispose of it
interpret any materials or objects other than bulk materials.

(4) can be manually is hinged only stationary vehicles
secured against displacement and overturning.

(5) increases to a vehicle or part thereof during tipping is prohibited.

(6) Folding and Hopper vehicle must be arranged so that, when

Transportation could spontaneously pop up or empty and tipping
overturn. Tipping and emptying vehicles must be so
masses to not endanger anyone.

(7) when moving or transporting radioactive sealed sources can be
present only persons whose activity is associated with these services.
Radioactive sources can only be carried
means for transporting persons, except for transport on conveyor belts.
Transportation of radioactive sources must be carried out as a priority.

§ 314

Special transportation

(1) The organization will issue a special load handling also working
instructions. The operational documentation must contain clear and transparent
drawings showing how to save or suspension and transported
securing the load special in a stable position.

(2) Special service must be performed by workers with at least two years experience in the mining
transport.

(3) Traffic Regulations and working instructions must be based on the conclusions of the assessment
device for conveying the load of special features and infrastructure, particularly in terms of carrying capacity
hinge monorail, or load the substrate transport paths used
to transport, static forces of surcharge under § 314a paragraph
. 5, the bow of the transport route, the weight and dimensions of the load, stability
burden with respect to its position and the position of its center of gravity when transporting and
assessment needed loading area of ​​the vehicle and a method
fixing load, and to the extent to prevent
unwanted movement, tilting or tipping load.

(4) In the Infrastructure segment, where it is carried out special transport, and in the immediate vicinity of the place
handling special burden must be carried
any action, nor are there no persons should be disinterested
special transport.

(5) Special transport is considered work associated with an increased danger
.. "

§ 314a

Requirements for special transportation

(1) Before commencement of special transportation worker inspects designed
device designed for special transportation, that is not damaged or visibly worn
above the allowed limit and whether it conforms to the accompanying documentation
manufacturer, traffic regulations and work instructions, and check the traffic flow
Infrastructure and given the kind of special traffic control also
:

a) of rail tracks, particularly the joints and horizontal and vertical arcs
targeting the transverse flatness and the turnout
|| | b) monorail and reinforcement of mine works in terms of their status and
stability

c) the quality and strength of the tunnel bottom transport route considering the weight
transported loads and their means of transportation, while the state verifies
ground tracks, especially the connection of individual sections, stability, anchoring
flatness and track and identify measures as necessary to eliminate hazards
resulting from a sudden change of direction in the vertical and horizontal plane

D) the quality and strength of the tunnel bottom transport route considering the weight
transported loads and their means of transportation skid and verify the status
Infrastructure Excavation.

(2) Transportation and handling during special traffic and at the same
repeated cases only the first shipping and handling, will monitor
staff member designated pursuant to § 307 paragraph. 2, which will also evaluate the safety and efficacy
technical and operational measures in all acts
special transport and depending on the outcome tighten measures provided
traffic regulations and working instructions. It shall inform the worker
designated pursuant to § 307 paragraph. 1st

(3) During a special transport may only be used for, or in accordance with paragraph 2
specified transport and slings.

(4) The special transport by rail track must be at an axial load of 60 kN
use lines of Category I-71).

(5) When transporting loads of abnormal weights on the monorail must be used
two or more carriers or trucks must be used lifter
beam to static force transmitted curtain hanging track on the reinforcement of the mine did not exceed
40 kN, does not determine if operational documentation
lower value.

(6) Lifting beams and slings used in transport must
bear the load. Their use must be monitored and recorded.
The accounting records shall also record the results of their review and

Function tests carried out at intervals specified by the manufacturer, and if not
set, then at intervals determined racing down.

(7) For special transport by land track locomotives and tractors:

A) they must be equipped with a locking device to prevent accidental driving
set independent of the engine is running or otherwise secured against unwanted
driving kit

B) they must be fitted with an interlocking or other signaling device
permanently exhibiting at least twice
safety in relation to the particular gravity component kits

(8) For special transport skid is necessary

A) for transport to transport the platform after special
leadership to develop a project that takes into account the suitability of the geological conditions and suitability
the invert, both for construction as well as maintenance of specific guidance as to reduce the possibility
the occurrence of sudden changes in the direction of leadership in the vertical plane
which could cause a loss of traffic management platforms

B) using winches with a fluent start.

§ 314b

Requirements harnesses, slings and locking elements in special transport


(1) For special transport must be attached a tow rope to the harness so
to exclude its eccentricity, shoulder harness was as long
and ensure the safety of each shoulder harness at least according to §
266 paragraph. 1st

(2) The transport platform during transport skid must allow the use of slings
funds. Transport platform during transport skid over special lines
must be provided with effective guidance over the conveying path so that
stable and preventing its unwanted rotation or overturning
or loss of guidance.

(3) Chain-time must be manufactured so that the stress on the individual chain links
corresponds at most their construction
sizing to length ratio of the binding chain to pitch fixing chain
the special burden was in the ratio of 1, 2: 1 or greater, and that the chain
articles were not yet subjected to other loads than that determined
their manufacturer. After each use, the chain-time when traffic
special burden must be visually inspected each
links in the chain; in case of detection of excessive wear or damage
relevant part of the chain excluded from further use.

§ 315

Work and removal of accidents on the roads

(1) Departments and the scene of the accident on road transport must be for the duration of labor or the removal
accident marked the manner specified in the transport
order. The designation must be located to allow safe
stop approaching vehicles, at all approaches to the workplace or
scene of the accident.

(2) When working on railway overhead lines must be operational documents
intended as measures for protection against electric shock
.

(3) Work on the slanting transport route will not be performed if the vehicle
(loads) has been reliably secured against driving or removed from
dipping routes. For reliable is not only to ensure
rope winch rope or fuel station.

§ 316

Lifting the derailed cars

(1) The derailment of the vehicle can be lifted only by means of a nakolejováno
identified in the transport order.

(2) The derailment of a vehicle must be secured against driving.
Must also be prevented from approaching another vehicle derailment of a vehicle.

§ 317

Transport velocity

(1) speed transport railcars locomotives must be determined by technical conditions
locomotives and rail tracks state.
Doing so it must be complied with the requirements of § 269 para. 4 or § 320 paragraph. 9th

(2) speed when transporting hanging locomotives must not exceed 12 kph
-1.

(3) The speed of the transport rope not exceed

A) 1 ms-1 when transporting endless rope, when used to connect car
rope locks

B) 2 ms-1 in the other cases of transport underground.

(4) speed transport with other transport machinery obey traffic regulations
[§ 308 para. 1 point. F)].

§ 318

Conditions for transport rope

(1) The rope must be conducted so as to avoid excessive friction (o
track infrastructure, reinforcement and equipment of the mine, etc.) And when connecting
vehicles or at random slack could capture
another vehicle or endanger personnel.


(2) below the gridiron barrier can be opened only when they are mining
wagons connected to the lanyard to dipping transport route, the rope is tensioned and balanced
return label from place to which is transported.

(3) Other barriers can be opened only shortly before transiting
mine vehicles.

(4) Barriers can be opened only at the time of transit.

(5) If the transport route for dipping or around the workplace
which could be affected by mining Mile for cars or trucks
suspended or ejected tracks the shipped material may only be transported
only when the workers at these sites reside
safe place (in the alcove side corridor, etc.).

(6) Paragraphs 2, 3 and 4 applies to stop moving.

§ 319

Operation of winches and drive and return stations for transport rope

(1) winches and drive and return stations for transport
rope must be located or protected so that they could roll transported
vehicle, the load or counterweight.

(2) The winch or motor station must be securely anchored
manner specified operating documentation, with the safety anchorage
must be at least 1.2 times relative to the nominal strength of the rope.

(3) Coiled rope must not be manipulated by hand.

(4) When used with two-drum winch to transport is one of the ropes must be
second rope secured to the drum so that they were never threatened.

(5) drum winch during transport must remain at least 3 coils of rope.

(6) Operator scraper winch must be protected against the rope swing
at a possible break from driving and scraper spoon.

§ 320

Transportation locomotives

(1) Transportation locomotives is permitted to bow, which is intended
technical conditions of the locomotive.

(2) on the front wall of the locomotives must be lit with a spotlight
white light and the last vehicle of the train or on the rear wall
locomotive when driving alone, red light; if set locomotive
pushed shall be at the rear of the locomotive and the red light on the front wall
first vehicle luminaire with white light. If it is pressed before
set crew may not be the first vehicle lamp.
When shifting to the marshalling of light may not be changed. Instead of red lights
can use another way to mark the end kit approved by state testing.

(3) Wagons long loads must be transported immediately behind the locomotive
.

(4) When transporting materials can be set only in the locomotive pushed
necessary and when moving, not only when in the kit
not transported long loads. Cargo vehicle drivers
not obstruct vision.

(5) For the carriage of persons must be set always drawn. In justified cases during transportation
suspension locomotive of an organization can allow
pushing vehicles, but the traffic order must be determined as at the
that ensure work safety and operation.

(6) Dragging mine vehicles on a side rail track is only permissible in
marshalling yards. With this shipment that nobody is between the locomotive and towed
mining trucks. The conductor or a staff member designated to handle
must go away before the kit. The campaign
mine vehicles can only be used for fasteners.

(7) current transportation locomotives with another machine
transportation must be addressed in the traffic order measures to ensure the safety and
operation.

(8) The combination of vehicles to transport workers must be involved
other vehicles except for vehicles transporting tools; That may be
placed only at the end of the set.

(9) of rail lines, which ensure visibility
distance of 80 meters, it racing down or persons authorized by permit
braking distance set in transport fuel to 60 meters when transporting people
up to 30 meters. These lines shall be marked with the appropriate label.

(10) Naskakovat and jump off while driving from railway locomotive can only
crew and only the necessary operational reasons, and at reduced speeds
at walking speed only in safe places.
Engine driver is obliged to follow the conductor.

§ 321

Shuttle monorail

(1) Before transportation on slanting tracks monorail to be transported separately
each vehicle or vehicles in each kit

Connected braking to prevent the truck driving the vehicle or combination.
Bow when changing tracks when transporting the rope must be a braking truck
connected on both ends of the kit.

(2) Shipments Suspended locomotive on slanting tracks monorail
must be attached to the end of the set braking to prevent the truck driving
vehicles carried locomotive. When driving the locomotive itself, whose
braking system is fitted with a speed limiter with brake trolley
need not apply.

(3) braking carriage must be phased out during transport function.

(4) When transporting persons on slanting tracks monorail must be a place
crew to allow direct braking kit.

(5) If a lifting device is part of the carrier truck must be transported
burden secured in the raised position.

(6) When using a lifting device, which is a burden lifted or
triggered with carrier trucks and moving part of the monorail track,
be carrying trucks moving parts trails secured so that it
could go off during handling. The moving part of the track monorail
must be in the upper position secured. Carrier trucks on a fixed part of the track
monorail must be secured against rolling out of track.

(7) For other types of lifting equipment load must be always secured against rolling
lifting of their parts. The lifting part must be in the end positions
ensured.

§ 322


Transport conveyors
(1) conveyor can be filled again only so as not to fall out
transported materials.

(2) Together with the muck may not be transported wood or other material
. Transportation of wood or other material must be stopped before starting
communicated to all employees who would such shipments could be threatened.

(3) transported in wood or other material can be removed from the conveyor
just behind the rear end against the direction of transport.

(4) around the belt conveyors must be cleaned constantly challenged by
materials. In places where there is a risk of entanglement with moving parts
conveyor or dropping materials from a conveyor belt cleaning and running around
prohibited; but it may be performed by designated
mechanization means.

(5) When the conveyor is running, not in its structure one
delay.

(6) For the carriage of persons prohibited the transportation of materials and conveyor belt
must not be slippery.

(7) for passenger transport conveyor belts must be established
safe boarding and deboarding platform and adapted dunes.
Platform must be securely accessed and provided with railings according to § 291 paragraph. 9 and 10. If
boarding and alighting hinged bridge is not used, it must be on the platform
handle to ease embarking and disembarking. Directly from the platform must be able to stop the conveyor
.

(8) At the time of transportation of persons shall be mine work illuminated the entire length
transport.

(9) The proximity to the station or place to ride through the dunes must be going
person alerted label at a distance of 15-20 meters before the exit
station or transfer point.

(10) When a wind speed of 17 ms-1 must be running conveyor belt
stopped if the technical conditions of the conveyor determines otherwise.

§ 323
Transport scrapers


(1) Transportation scrapers is permitted to bow 40 degrees.

(2) The location for dumping must be in operation effective anti-dust
devices (suction, spraying, etc.).

§ 324
Transport gravity


(1) Magazines incurred stamping mines and chutes must be clean except
completely emptied.

(2) materials in the hopper and chute can be released only from the outside
safe place as intended.

(3) Working inside the tank must be carried out under constant surveillance.
Access reservoir above may only after verifying the safety of air
and stop filling and unloading. Transportation equipment leading into the tank
must be secured to prevent accidental actuation.
Worker inside the tank must be protected by two workers from the outside and must be strapped
protective harness with shock drop of energy to the locking cable.
Lifelines must still be tight. A worker inside the tank
must be kept stable connection.

(4) Gravity pipe in the pit should not be used for storage of materials.
A third part


Storage of fuel and materials

§ 325

Common provisions


(1) The location of landfills and warehouses in the protection zones must be addressed
under special regulations. ^ 74)

(2) Permanent storage area must be flat, drained, paved and marked with safety
tables to ban the entry of unauthorized persons.

(3) Storage space must have a height corresponding stored and used
mechanization; a space where workers have
move and work, must have a height of at least 1.8 meters underground and on the surface
least 2.1 meters.

(4) The method of storing materials production and width of traffic routes must conform
used machinery.

(5) During storage must be ensured safe supply, storage and removal
materials production.

(6) the storage material must be stored so that it is at all times ensured
storage stability.

(7) Employees who work in the areas of storage, must be familiar with the division
storage spaces for different types of fuels and materials
and conditions of safety and operation of storage.

§ 326

Storage of bulk materials

(1) Dump mineral extracted prone to spontaneous combustion
must be sufficiently distant from the mouth of the mine and vtažného from workplaces
permanent service, but at least 60 meters along the prevailing wind direction.
Location of landfills other minerals or soils must be dealt with
regard to the possibility of adversely affecting the surrounding workplaces
pollutants from the landfill.

(2) For the operation of the landfill mineral extracted or soil must be prepared
operational documentation to determine safety measures for
supply, storage, storage and removal of materials, securing and moving machinery at work
landfill and possible measures against spontaneous combustion.

(3) Loose material can be freely stored in a fully mechanized manner
to any height, if their removal will be mechanized.
When removing materials must be avoided creating overhangs. Once an
wall, withdrawal shall be adjusted so that the height of the wall does not exceed the allowable range 10.9
loading machine.

(4) In manual stacking and reclaiming bulk materials can be stored
only to a height of two meters.

(5) If the collecting loose material by hand or mechanical shovel must be taking
modified to avoid overhang and the height of the wall does not exceed 1.5 meters
.

(6) At the landfill solids with bottom removal workers must
linger dangerously close to the consumption point.

§ 327
Storage of materials


(1) Equipment landfills and warehouses, or supporting structures must be
made to allow storage, storage and removal
piece of material, liquids and packaging in accordance with the manufacturer's requirements or special regulations
. ^ 75)

(2) Design features that would be in storage at each other and just fallen on
have fastening elements, which would allow secure gripping, possibly
suspension (eye, handles etc.), Must be deposited on substrates;
timber and laminated substrates may be used.

(3) The particulate material of regular shapes can be manually stored into
height of 2 meters. Lumpy irregular shapes (stone
irregular shapes and the like.) Can be fixed manually straightened the border into
height of 1.5 meters.

(4) Rounded objects (cans, bottles, etc.) In securing stability
can be manually stacking up to 2 meters. Tubes and
logs must be secured against slipping.

(5) sacks of bulk material can be manually saved to a height of 1.5 meters
when saving a mechanized method to a height of three meters.
Edges of the piles must be secured auxiliary equipment (opera, wall, etc.)
Or bags deposited in safe custody and inclination, for which there can be no slipping
bags.

(6) Containers with liquids must be sealed and stored so that the filling
(drain) hole was always on top. Drums and similar containers can be stored upright
only in one layer. Horizontal position can be stacked in multiple layers
assuming that the individual layers are mutually stabilized
optionally will be stored in a structure ensuring their
stability.

(7) Open tanks must be secured against persons falling into them.

(8) Acids and other dangerous substances must be stored in containers with

Designation of the substance. Safe storage method determined by the organization
type of packaging.

(9) Clamping and disconnection in slings material handling
is done from the ground or secure platforms or floors so tying
been conducted in more than a working height of 1.5 meters.
Engagement and unbuckle slings surfaces of the equipment can only
case, avoiding spontaneous movement of the stored material.
Material Handling is possible only when the employee withdrew to a safe place
.

(10) for the storage and handling of explosives, flammable liquids,
poisons and other hazardous substances also specific regulations. ^ 20)
^ 76)

(11) Organizations can store radioactive sources only in areas approved
this purpose.
PART TEN


Transitional and Final Provisions

§ 328
Transitional provisions


(1) Mining works, buildings, waste dumps and equipment brought into use before
entry into force of this Decree may be used provided that they meet the requirements
generally binding legal regulations in force at the time of their entry into
usage. During the reconstruction or overhaul
must be mines, buildings and equipment brought into conformity with this decree
if when authorizing such work otherwise specified.

(2) The organization shall review its measures to ensure the safety and operation
issued before the effective date of this decree and adapt them
this decree within 6 months of its entry into force.

(3) The obligations set out in § 6 par. 4, § 8 par. 5 of the second sentence of § 189
paragraph. 8 and last sentence of § 224 paragraph. 5 must be met by 1 January 1991.


§ 328a


Mutual recognition clause
If the ordinance sets requirements beyond those set
relevant European Community, does not apply to those
requirements for products that have been produced or marketed in
a Member State of the European Union or Turkey or having
origins in any of the countries of the European free trade association, which is currently
party to the Agreement on the European Economic area, as
provided that such product complies

A) technical regulations which are producing or marketing, or
for the use of this product in any of these countries
binding

B) technical standards or codes of good practice, which are issued
national standards body or a body equivalent, built,
in accordance with the laws and requirements of the State that is a contracting party
European Economic Area ,

C) international technical standards legitimately used in some of these states
or

D) traditional or innovative production processes used in some of these countries
in accordance with its legislation, for which there
sufficiently detailed technical documentation to ensure that this product can be
for the intended use assessed, if necessary, on the basis
additional (but not identical) product testing, if these
technical regulations, technical standards, codes of practice or procedures guarantee peace
protect legitimate interest, corresponding to the degree of protection in the Czech | || Republic.

§ 329
Exceptions


(1) The provisions of this Decree may be waived for the period required
where the risk of delay in rescuing people or
deal with serious operational accident (crash) when they performed
minimum security measures.

(2) Except as provided in paragraph 1 may
organizations from the provisions of this Decree depart consent of the Czech Mining Office and
under conditions set by the proposal supported by the necessary racing down
alternative measures and the recommendation of the
organ of social control. Proposal shall be submitted through the district mining office,
and only in exceptional cases and under the assumption that it will ensure
safety and operation.

§ 330

Validity of decisions issued under the existing regulations

The decision of the State Mining Administration issued remain valid
regulations to ensure the safety and operation remain in force
unless the authority that issued it stipulates otherwise.

§ 331
Repealing provisions



Repealed:

First Proceeds of the Czech Mining Office dated 3 January 1971, ref. No. 1/71, which is issued
regulation on occupational safety and health and safety
organizations, they are subject to Law no. 41/1957 | || Coll., on the use of mineral resources (Mining Act) (Reg. 7/1971 the amount
Sb.).

Second Proceeds of the Czech Mining Office dated 13 March 1972, ref. No. 1487/1972,
authorizing replace in some cases taking prescribed
mine air samples and chemical analysis of indications.

Third Proceeds of the Czech Mining Office dated 12 May 1980 ref. No. 2700/1980
on occupational safety and health and safety at
organizations that are subject to state expert supervision of state
mining administration according to law Czech national Council no. 24/1972 Coll., on
organization and expansion of the surveillance state mining administration (reg. in the amount
26/1980 Sb.).

Fourth Proceeds of the Czech Mining Office no. 7/1981 of 29 June 1981, ref. No.
4045/1981, amending Decree of the Czech Mining Office dated January 3
1971 on occupational safety and health and
safety in organizations, they are subject to law no. 41/1957 Coll., on
utilization of mineral resources (Mining Act) (Reg. in the amount of 34/1981 Coll.).

Fifth Proceeds of the Czech Mining Office dated 17 June 1982 no. 5/1982 p. v.
Czechoslovakia, supplementing the income of the Czech Mining Office dated 3 January 1971
ref. no. 1/1971, issuing a prescription and safety
health and safety in organizations if
subject to Act no. 41/1957 Coll., on the use of mineral resources (the Mining Act
) (Reg. in the amount of 21/1982 Coll.).

6th Proceeds of the Czech Mining Office dated 20 January 1983 no. 5/1983 p. v.
Czechoslovakia amending Decree of the Czech Mining Office dated January 3, 1971
no. j. 1/1971, which issues regulations on health and safety at work and
safety organizations, if they are subject
Act. No. 41/1957 Coll., on the use of mineral resources (Mining Act).

7th Proceeds of the Czech Mining Office dated 20 January 1983 no. 6/1983 p. v.
Czechoslovakia on occupational safety and health and safety
for transport on suspension railways.

8th Proceeds of the Czech Mining Office dated 1 February 1985, ref. No. 84/1985,
amending and supplementing Decree of the Czech Mining Office dated 3 January 1971
ref. No. 1/1971, which issues regulation and safety
occupational health and safety in organizations where
subject to Act no. 41/1957 Coll., on the use of mineral resources (the Mining Act
) reg. in the amount of 7/1971 Coll . (Reg. in the amount of 19/1985 Coll.).

9th Proceeds of the Czech Mining Office no. 17/1985 amending Decree
Czech Mining Office dated 3 January 1971, ref. No. 1/1971 laying
issued regulations on occupational safety and health and safety
operation in organizations, they are subject to law no. 41/1957 Coll., on
utilization of mineral resources (Mining Act) (Reg. in the amount of 36/1985 Coll.).

10th Proceeds of the Czech Mining Office dated 22 January 1986, ref. No.
1060s / 1985 amending and supplementing Decree of the Czech Mining Office no.
J. 1/1971 on occupational safety and health and safety
operation in organizations, they are subject to Law no. 41/1957 Coll., On
utilization of mineral resources (Mining Act) (Reg. 4/1986 the amount of Sb .).

11th Proceeds of the Czech Mining Office dated 22 January 1986, ref. No.
1060s / 1/1985 amending and supplementing Decree of the Czech Mining Office no. 4/1980
p. v. Czechoslovakia on occupational safety and health and safety
organizations that are subject to state
professional supervision of state mining administration by the Czech National Council no.
24/1972 Coll., on organization and the extension of the surveillance state mining administration
(reg. in the amount of 4/1986 Coll.).

12th Proceeds of the Czech Mining Office dated 17 December 1986, ref. No.
1903/1986, amending and supplementing Decree of the Czech Mining Office
On 3 January 1971, ref. No. 1/1971, which issues
regulations on safety and occupational health and safety organizations, if
subject to Act no. 41/1957 Coll., on the use of mineral wealth
(Mining Act) (Reg. 7/1987 in the amount of Sb.).

13th Proceeds of the Czech Mining Office dated 9 March 1987, ref. No. 6385/1986,
supplementing the income of the Czech Mining Office dated January 3, 1971 no.

J. 1/1971 establishing the Community legislation on safety and health at work and
safety organizations, they are subject to the law no.
41/1957 Coll., On the use of mineral resources (Mining Act) (reg.
amount 11/1987 Coll.).

14th Proceeds of the Czech Mining Office dated 27 December 1987, ref. No.
6594/1987 supplementing the income of the Czech Mining Office of 3
January 1971, ref. No. 1/1971 on safety and health at
work and traffic safety organizations, they are subject to law no. 41/1957
Coll., on the use of mineral resources (Mining Act).

15th Regulation of the mining district office for the country Czech in Prague no. 720/1947
p. l., for the operation and lignite briquetting plants to produce
lignite dust.

16th Central Mining Authority Decree no. 263/1957 p. l., which
adapting certain provisions of the State Mining Administration.

§ 332
Efficiency


This decree comes into force on 1 July 1989.


Příl.1
Hand label




Příl.2

Traffic signals






Příl.3
Dimensions and editing labels



Selected provisions of amendments


Art. II of Act 282/2007 Coll.
Transitional provisions


First Accumulation of functions racing mine manager or employee
ventilation to control the installation, operation and maintenance of electrical equipment for more
down or with other functions in gassy mines and also features
geomechanics in mines with danger of rock bursts must be made
into compliance with this Decree within six months of its entry into force.

Second Gassy mines spaces included in terms of the danger of explosion
methane into effect hereof as spaces SNM is 0
deemed spaces BNM.

Third Gassy mines spaces included in terms of the danger of explosion
methane into effect hereof as spaces SNM 1, 2
SNM or SNM 3 are considered SNM spaces.

Fourth Coalmines spaces included in terms of the danger of explosion
coal dust into effect hereof as SNP 0
spaces are considered spaces BNP.

Fifth Coalmines spaces included in terms of the danger of explosion
coal dust into effect hereof as spaces SNP
1 or 2 SNPs are considered spaces SNP.

6th The requirements of § 231a paragraph. 4 must be met by 1 January
, 2012. It does not apply to mines with renowned declining industries and mines
with the expected completion of mining operations until 31 December 2013;
Assumption cessation of mining activities must be documented opinion
District Mining Authority.

7th § 231D requirements must be implemented no later than 31 December
, 2010. It does not apply to mines with renowned declining industries and mines
with the expected completion of mining operations until 31 December 2012;
Assumption cessation of mining activities must be documented opinion
District Mining Authority.

Art. III Decree no. 35/2010 Coll.
Transitional provisions


First The requirement in § 231a paragraph. 4 point. d) Decree no. 22/1989
Coll., on occupational safety and health and safety at
mining activities and the conquest of unrestricted minerals underground, as amended effective
effective date of Decree no. 35/2010 Coll., it is necessary to fulfill


A) new and refurbished circuit breakers listed first
into service after the effective date of this decree, to June 30, 2010,

B) for circuit breakers, re-installed after the effective date of this decree
, June 30, 2011,

C) for other circuit breakers until 30 June 2012.

Second The requirements set out in § 15 para. 3 of Decree no. 659/2004 Coll., On
occupational safety and health and safety in mines
danger of rock bursts, as amended, effective from the effective date of the Decree
C. 35/2010 Coll., To be filled by 31 December 2010.

1) § 2 Act No. 61/1988 Coll., On mining, explosives and
State Mining Administration, as amended by Act No. 425/1990 Coll. and the CNR Act No.
. 542/1991 Coll.

1) § 3. a) Act No. 61/1988 Coll., as amended
regulations.

1b) Council Directive 92/104 / EEC on the minimum requirements for improving
safety and health of workers in surface and underground mining industries
.


3) Eg. CSN 01 8012 Safety signs and tables, CSN 34 3510
safety signs and signs for electrical devices, ON 44 0090
Safety signs and tables for mines.

4) Act no. 120/1962 Coll., On the fight against alcoholism.

§ 135 paragraph. 2 point. b) and paragraph. 3 of the Labour Code.

Governmental Czech Socialist Republic no. 192/1988 Coll., On
poisons and some other substances harmful to health.

5) § 133 paragraph. 2 of the Labour Code.

5a) § 132a paragraph. 3 of Law no. 65/1965 Coll., The Labour Code, as amended
Act no. 155/2000 Coll.

6) Act no. 50/1976 Coll., On Territorial Planning and Building Code (Building Act
).

Decree of the Czech Mining Office no. 104/1988 Coll., On
rational use of reserved deposits, on permits and notification of mining operations
and reporting activities associated with mining.

7) Decree of the Czech Mining Office from 29 December 1987 no. 8/1987 on plans
fighting serious operational accidents in underground mines (reg. In the amount
4/1988 Coll.).

8) § 273 of the Labor Code.

9) Directive of the Ministry of Health of Czechoslovakia ref LP / 1-265-19.5.70 of
changes in assessing fitness to work (reg. In the amount
20/1970 Sb.).

10) CSN 05 0610 Welding. Safety requirements for welding
flame cutting.

CSN 05 0630 Safety requirements for arc welding.

CSN 05 0650 Safety regulations for arc welding.

10a) § 2. a) Decree no. 659/2004 Coll., on the protection
health and safety in mines with danger
shake mine.

10b) § 3 para. 2 of Decree no. 659/2004 Coll.

11) § 6 par. 4 of the Act No. 61/1988.

12) § 6 para. 5 of the Act No. 61/1988.

13) § 2. b) Decree no. 659/2004 Coll.

14) Decree of the Czech Mining Office no. 56/1982 Coll., Which determines
circuits covered by the Mining Authorities.

15) Decree of the Central Mining Office and Central Geological Office
of 31 January 1962 no. 1000/1962, by management and replenishment
geological documentation (reg. In the amount of 42/1962 Coll.).

Decree of the Czech Mining Office of November 6, 1986 no. 1/1987 p. v.
Czechoslovakia on mine surveying documentation in underground mines (reg. in the amount
27/1986 Coll.).

18) Methodical instruction no. 33/1974 Ministry of Health Bulletin
Czech Socialist Republic, principles of organization and providing first aid
.

19) Decree no. 104/1988 Coll.

20) Decree of the Czech Mining Office no. 72/1988 Coll., On explosives.

20a) § 2. b) Decree no. 4/1994 Coll.

21) Decree of the Czech Mining Office no. 12/1982 p. v. Czechoslovakia
safety and occupational health and safety for vertical transport and walking
organizations subject to supervision by the State Mining Authority (reg.
in Chapter 19/1983 Sb.), as amended by Decree of the Czech Mining Bureau of 7 July 1986
no. 16/1986 p. v. Czechoslovakia (reg. in the amount of 18/1986 Coll.).

22) Decree of the State Committee for Science and Technology and Investment Development No..
5/1987 Coll., On construction documentation.

24) ON 44 8252 Výbuchuvzdorné closing the dam.

24a) § 2. d) Decree no. 4/1994 Coll., laying down
requirements for the design and construction of buildings and equipment for the distribution and isolation of winds and closing
workings, as amended.

24b) § 2. a) Decree no. 4/1994 Coll.

24c) § 4. i) Decree no. 298/2005 Coll., on requirements for professional
competence in mining activities or activities carried out by mining
way and amending certain laws.

25) ON 44 8112 Barrier door. Security policies.

ON 44 6451 Mining výbuchuvzdorné dam. Objects dam door
gypsum panels.

26) ON 44 6310 Wind door.

27) ON 34 1611 Power Systems mining electrical networks and appliances.

28) ON 44 6008 Determination of the ventilation air duct leakage
moves.

ON 44 6009 Calculation separate ventilation long mining works.

28a) Decree no. 165/2002 Coll., On separate ventilation for mining
activity in gassy mines.

29) Decree of the Czech Mining Office no. 68/1988 Coll., On selected mining
devices.

29a) CSN 83 0050 Sampling of mine air.

30) CSN 44 6401 Disposal of deposited coal dust.


31) CSN 44 6405 Sampling and analysis of samples and inert dust mixtures
coal and inert dust.

32) ON 44 9104 Mine fire mains. General provisions.

35) Czech National Council Act no. 133/1985 Coll., On Fire Protection.

The Ministry of Interior of the Czech Socialist Republic no. 37/1986
Coll., Which implements certain provisions of the Czech National Council on
fire protection.

35a) EN 730 Gas welding equipment.
Equipment used in welding, cutting and allied processes. Safety device for
combustible gases and oxygen or compressed air. General specifications, requirements and testing
.

36) ON 44 6478 Race warehouse fire. The technical requirements.

37) Eg. ON 44 6670 Warehouses flammable liquid and solid lubricants underground
underground mines, ON 44 2608 Spatial mines.
Mine draws air and diesel locomotives, CSN 07 8305
metal pressure vessels for transporting gas. Technical rules.

38) Decree of the Czech Mining Office no. 67/1988 Coll., On mining rescue
service.

39) § 10 paragraph. 1 of Czech National Council no. 61/1988.

40) CSN 44 6410 Full water dam. General principles.

41) § 10 paragraph. 6 Czech National Council Act no. 61/1988.

42) ON 44 2252 Mining petrol station.

43) Eg. the directive of the Ministry of Health of the Czech Socialist Republic
- Chief Hygienist of the Czech Socialist Republic no. 40/1976
Collections sanitary regulations on hygiene requirements for stationary
machines and technical equipment (reg. in the amount of 20/1976 Coll.)
directive of the Ministry of health of the Czech Socialist Republic no. 65/1985
Collections sanitary regulations on hygiene requirements for mobile
machines (reg. in the amount of 7/1985 Coll.), CSN 33 2030 protection against dangerous
effects of static electricity, CSN 34 1382
Testing the electrostatic properties of materials and products from non-conductive materials.

44) CSN 33 0300 Electrical regulations.
Types of environment for electrical equipment.

CSN 33 0330 Coverage electrical equipment. Regulations and testing methods.

CSN 33 2310 Electrical regulations. Regulations for electrical equipment
in different environments.

CSN 33 2320 Electrical regulations. Regulations for electrical equipment
in areas with a danger of explosion of flammable gases and vapors.

CSN 33 2330 Regulations for electrical equipment in hazardous
explosion of combustible dust.

CSN 33 2340 Electrical equipment in hazardous fire or explosion
explosives.

CSN 34 1010 General requirements for protection against dangerous contact voltage
.

CSN 34 1410 Electrical equipment in the basement.

45) Decree of the Czech Occupational Safety Office and Czech Mining Office No.
. 18/1987 Coll., Laying down the requirements for protection against explosions
combustible gases and vapors.

46) Decree of the Czech Occupational Safety Office and Czech Mining Office No.
. 92/1985 Coll., On work safety in stable trays
bulk materials.

46a) § 1 par. 2 of the Government Regulation no. 170/1997 Coll., Laying down
technical requirements for machinery, as amended by Government Decree no. 283/2000 Coll
.

47) CSN 83 2041 Working protection. Guards production facilities.
General requirements.

49) CSN 33 3210 Electrical regulations. Distribution equipment. Common
provisions.

50) ON 44 2608 Spatial mines. Mining and draws air
diesel locomotives.

51) ON 44 5090 trackless mining machinery. The technical requirements.

52) Decree of the Czech Occupational Safety Office and Czech Mining Office No.
. 50/1978 Coll., On professional qualification in electrical engineering, as amended by Decree
Czech Office for Occupational Safety and Czech Mining Office no. 98/1982 Coll
.

52a) Decree no. 23/2003 Coll., Laying down
technical requirements for equipment and protective systems intended for use in potentially explosive atmospheres
.

EN 1127-2 Explosive atmospheres - prevention and explosion protection -
Part 2: Basic concepts and methodology for mining.

53) Decree of the Ministry of Construction no. 77/1965 Coll., On training
eligibility and registration of operators of construction machinery.

The Ministry of the Interior no. 87/1964 Coll., On driving licenses, as amended
.


CSN 26 8805 Diesel trucks. Operation, maintenance, repair.

54) of the Federal Ministry of Transport dated 16 November 1979
Ref. 16 349/79 on the rules of technical operation of sidings (reg. In the amount
27/1979 Sb.).

ON 44 3066 Training and Examination Regulations for personnel mine railways (D - A2).

55) Decree of the Czech Mining Office from July 23, 1981 no. 17/1981 OJ
Czechoslovakia on occupational safety and health and safety
for drilling and geophysical work and for the extraction, processing and underground storage of liquid
minerals and gases in natural rock structures
organizations subject to the supervision of the state mining
administration (Reg. in the amount of 33/1981 Coll.), as amended by Decree of the Czech Mining Office no. 18/1986 OJ
CSR (reg. In the amount of 18/1986 Coll.).

56) CSN 34 1090 Regulations for Temporary electrical equipment.

56a) Art. 312.2 CSN 33 2000-3 Electrical regulations - Electrical
- Part 3: Setting the basic characteristics.

Art. 413.1.5 CSN 33 2000-4-41 Electrical regulations -
Electrical Equipment - Part 4: Safety - Chapter 41: Protection against electric shock
.

56b) Article. 312.2 CSN 33 2000-3.

Art. 413. N6.3 CSN 33 2000-4-41.

56c) Article. 312. 2 CSN 33 2000-3.

Art. 413. N6.1 CSN 33 2000-4-41.

56d) For example, CSN 33 3201 Electrical installations over 1 kV AC.

57) CSN 34 1410.

58) CSN 33 2320.

60) CSN 33 3210.

CSN 33 3220 Electrical regulations. Common provisions for
electric stations.

ON 44 0420 Mining substation and transformer stations.

60a) CSN 33 2000-4-41.

61) CSN 33 2200 Electrical regulations.
Electrical equipment of machines.

62) CSN 34 3510.

63) CSN 34 3100 Safety regulations for the attendance and work on electrical equipment
.

64) Eg. CSN 34 3800 Revision of electrical equipment and conductors, CSN 34 3880 Revision
electric portable tools in operation.
Security measures, CSN 34 3881 Revision of portable electric tools
Class II. and III. working.

65) CSN 34 1610 Electrical power systems in industrial
premises.

67) CSN 34 1010.

CSN 34 1410.

68) CSN 36 0010 Light Metering. Generic standard.

CSN 36 0035 Daily illumination of buildings.

CSN 36 0050 Illumination underground mines.

CSN 36 0451 Artificial lighting of industrial areas.

69) CSN 26 0003 Transportation equipment. Design, construction and installation
.

70) ON 44 0092 Mining traffic signal.

71) CSN 44 5004 Narrow-gauge tracks in underground mines.

72) ON 44 3061 signaling pathway mining regulations (D-D1).

ON 44 3062 Traffic regulations for mine rail (D-D2).

73) Decree of the Czech Occupational Safety Office no. 88/1980 Coll., On
work safety and technical equipment during operation
road vehicles, as amended.

74) Eg. Law no. 79/1957 Coll., on the production, distribution and consumption of electricity
(Electricity Act), Act no. 135/1961 Coll., on
roads (Road Act), Act no. 51/1964 Coll., on Railways, as amended by Act no.
104/1974 Coll., Act no. 110/1964 Coll., on Telecommunications, law no.
138/1973 Coll., on waters (water Act) .

75) Eg. CSN 07 8304 Metal pressure vessels for transport of gas.
Operating rules, CSN 26 9030 Storage. The principles of safe handling, CSN 26 9101
pallets and pallet extensions. The principles of safe handling, ON 49 0650
Storage of lumber for natural drying, ON 49 0811
Safety regulations for logs and lumber stores.

76) Eg. Government Regulation No. Czechoslovakia. 192/1988 Coll., Decree no. 59/1972 Coll.
CSN 65 0201 Flammable liquids. Plants and warehouses, ON 44 6670

77) Section 1.7.4 of Annex no. 2 Government Regulation no. 24/2003 Coll., Which establishes technical requirements
machinery.

Item 1.0.6 of Annex. 2 Government Regulation no. 23/2003 Coll., Laying down
technical requirements for equipment and protective systems intended for use in
explosive environments.

79) § 2. a) Act no. 22/1997 Coll., on technical requirements for
products and amending and supplementing certain acts.

80) Act no. 22/1997 Coll.

80a) § 12 of Decree no. 165/2002 Coll.

81) § 30 of Decree of the Czech Mining Office no. 8/1987 of 29 December 1987 on plans
fighting serious operational accidents in underground mines
(reg. In the amount of 4/1988 Coll.).


82) § 6 of the Decree of the Czech Mining Office no. 340/1992 Coll., On requirements
qualification and competence and verifying professional competence
workers for mining activities and activities carried
mining methods and change some regulations issued by the Czech mining Office
to ensure occupational safety and health and safety
operation in mining activities and activities conducted by mining methods.

83) Decree of the Federal Ministry of the Interior no. 99/1989 Coll., On
rules of road traffic, as amended
regulations.

§ 7 paragraph. 1 of Law no. 13/1997 Coll., On the road.

§ 10 par. 2 Act no. 12/1997 Coll., On safety and flow of traffic on roads
.