(December 29, 2003 Guiyang Government Executive Conference considered through on February 18, 2004 Guiyang Government makes 128th, announced since on April 1, 2004 up purposes) first chapter General first article for further strengthening city planning management, improve planning management work level, makes city planning management legal of, and scientific, and standardized, according to People's Republic of China city planning method, and Guiyang City Planning Management Ordinance and the about regulations, and specification, combined this city of reality, These provisions are formulated. II preparation of the district plan, detailed planning (including controlled detailed planning and detailed construction planning), the professional planning, urban design, landscape planning and architectural floor plan design must comply with these provisions. Plans should be adopted independent coordinate system in Guiyang City in 1956 and huanghai sea systems. Third, urban planning and construction in the area, the project planning and implementation, according to the regulations. Town House (including the building of urban residents and rural housing) separately. This provision is not clear, according to relevant laws, regulations, guidelines. Qingzhen city, the fourth article, kaiyang, xiuwen, Xifeng County, reference to these provisions. Chapter of urban construction land use classification and appropriate ranges fifth land for urban construction should be built according to the urban land classification and land planning and construction standards (GBJ137-90) for classification. Sixth, well-built range of construction land according to the approved detailed plans of implementation. Urban zoning plan within the planning area, the controlled detailed planning and detailed construction plans have not been overwritten, overall planning of land use in Guiyang City, all kinds of building land and built range schedule a range of all kinds of construction land and built form (hereafter referred to as schedule a). Chapter III building capacity control indicator and in urban planning in the article seventh new construction, expansion and renovation of building volume rate of construction projects, building density, should be determined according to the approved plan. Detailed planning has been produced according to Schedule II of the building density and volume control indicator tables (hereinafter Schedule II) provisions, approved by the Administrative Department for urban planning. Schedule II is not explicitly control indicator in the eighth administrative, cultural, education, health, sports, scientific research institutions, industrial plants, warehouses, military facilities, as well as for residential public services, community support facilities, such as the building density and volume rate indicator, in accordance with the relevant regulations and guidelines. Nineth construction land in 20,000 square meters (20,000 square meters) or longer, detailed construction plans in accordance with the planning and design of urban residential area code (GB50180-93) building capacity control targets set by the Executive. In 20,000 square metres of building land, of constructional detailed planning of Schedule II implementation. Tenth multi-storey civil buildings construction land is less than 1000 square meters, high-rise residential construction is less than 2000 square meters, the top is less than 3000 square meters of public buildings construction land, not building alone. 11th commercial road in the center of construction projects, the ground can be used to provide the community with square, sunken Plaza, public car park, roof terraces, walkways, green space and other public open spaces, meet planning requirements and the relevant provisions of the premise, can increase capacity rate, increased floor area increases the area controlled by Schedule III the provision of open spaces form control. Approval to increase the floor area may not exceed the gross floor area of 25%, and shall not be modified to make it as open space, no additional buildings. 12th construction land in the construction of a different nature, shall be classified and designated building land, building density and floor area ratio calculated respectively. Is a commercial or residential building, building density in Schedule II implementation of indicators for public buildings, the building volume rate subject to a different area in the nature of conversion of synthesis. Business area or Office area of the area of 10% was not, or only for commercial or Office at the bottom of comprehensive residential, residential area, the building volume rate schedule II housing indicators in implementation. 13th available terrain elevation difference of construction land, fire engines can be reached directly into the roof and the building entrance, the building density not greater than 60%. Fourth chapter building article 14th building spacing must comply with fire safety, health, environmental protection, landscaping, security, engineering, architectural design specifications and the provisions of laws and regulations on cultural relics protection. The 15th residential space should be based on meeting sunshine requirements considering lighting, ventilation, fire prevention, disaster prevention, pipeline laying, vision and health requirements. High-rise residential space as follows: (a) the sunshine distance North-South parallel arrangement of residential housing, building height and building positive spacing ratio of l to 1:1.1, (ii) housing front space reduction, shall be determined according to the sunshine standards sunshine distance coefficients of different direction control or reduction factor four different orientations of the spacing in the Schedule table of conversion. (Three) mutual vertical layout of residential, Gable face longitudinal wall surface, Gable shall not open window pick balcony, depth should be control in 12 meters following, minimum spacing shall not less than 10 meters, Pro gable Bay shall not double side set balcony; depth is greater than 12 meters of gable or gable open window of, should according to open window surface sunshine spacing concession, balcony set shall not is greater than building width of two-thirds. (D) neither parallel nor perpendicular arrangement of apartment 1, when two residential wall window facing vertical wall of Windows that open face angle is less than or equal to 15 °, by opening the window open the window of space requirements, the narrowest spacing shall not be less than 1:1. 2, when two residential vertical wall of Windows facing the vertical wall window surface greater than 15 ° less than the angle of 45 °, the narrowest spacing shall be not less than 15 m. 3, when two residential wall to open the angle of the vertical wall of the window open the window is equal to or greater than 45 ° is less than 60 °, the narrowest spacing shall be not less than 13 m. 4, when two residential wall to open the angle of the vertical wall of the window open the window is equal to or greater than 60 ° is less than 90 °, gable wall window spacing control, shall be not less than 10 metres at its narrowest spacing. (E) domestic arrangement South, East or South East, South West slopes high up to 30 ° when using terrain elevation difference of specific size, space reduction, after the reduction of space shall be not less than 13 m; North to within 30 ° slope, depending on the specific size of topographic height difference, increased spacing. 16th senior housing in gable and gable distance shall be not less than 7 metres, Gable may not open the window, and choose the balcony. Gable and gable spacing greater than or equal to 10 metres, Gable Windows that allow ventilation in high, do not pick the balcony. Spacing between the high-rise apartments in the 17th 1:1; high-rise apartment and the adjacent residential space in accordance with the relevant provisions of the present article 15th. 18th 24 m between the following public buildings and high-rise residential space according to the provisions of the 15th, 16th, 17th of regulation. 19th article senior building and in the senior following residential of spacing must meet following provides: (a) North-South to layout, width is less than is equal to 40 meters of senior building and North residential of spacing by senior building height of 0.4 times times control, and minimum spacing shall not is less than 30 meters; width is greater than 40 meters of senior building and North residential of spacing by senior building height of 0.5 times times control, and minimum spacing shall not is less than 30 meters. (B) the width of 40 m or less high-rise buildings and 0.35 times times the residential space on the South side by high-rise building height control, and the minimum distance shall be not less than 20 metres; width greater than 40 m tall buildings and houses on the South side of 0.4 times times the spacing according to the tall building height control, and the minimum distance shall be not less than 24 meters. (C) the building headed for East-West, high-rise buildings and houses on the West side of 0.4 times times the spacing according to the tall building height controls, high-rise buildings and residential space in high-rise buildings East of 0.35 times times the height of the control, and the minimum distance shall be not less than 24 meters. (D) top-short side or Gable, point architectural surface and upper House Gables of the following spacing must not be less than 13 meters. (E) high-rise building annex and the adjacent residential space according to the provisions of article 15th. 20th two high-rise architecture and street layout of continuous high-point of Windows that open space between, North-South parallel arrangement, not less than 0.45 times times the height of buildings on the South side, and not less than 24 metres; things arranged in parallel, East side of not less than 0.4 times times the height and not less than 20 metres. 21st retaining walls, slope protection and construction of minimum spacing requirements. (A) under the influence of geological hazard-free, should meet the housing need of sunshine, ventilation, protection, fire. (B) the height greater than 2 m less than 6 metres of retaining wall and upper edge of the slope and building the net distance shall be not less than 5 metres, lower margins and building the net distance shall not be less than 3 meters. (C) a height greater than 6 metres of retaining walls should be back, back width of not less than 1.5 m. 22nd light tank of high-rise residential buildings, the aspect ratio is not less than 1:2.5, Groove width min shall not be less than 2.7 m; high-rise residential lighting in tanks, aspect ratio of not less than 1:2, Groove width min shall not be less than 2.4 metres; Senior House patio plane axis dimensions not less than 3.3 m X3.3 meters. 23rd nursery and kindergarten classrooms and living rooms of their block distance of the building must meet the winter solstice full window sunlight standard of not less than three hours of sunshine, nursery and kindergarten activities must meet the one-second of the activities area in building Sun shadow line beyond the requirements of the standard; in primary school buildings should meet the winter solstice sunlight standard of not less than two hours. 24th 100 meters above the space of high-rise buildings and other non-residential buildings, special terrain, lots of architectural space as transportation, fire, lighting, ventilation, under specified conditions of the urban landscape, the Department of City Planning Administration in accordance with the relevant provisions. Fifth chapter building concessions from the 25th buildings along city roads, highway, railway, River and drainage lines, civil air defense facilities, heritage, power reserve and land border construction, shall comply with the provisions of the relevant laws, regulations, norms and the provisions of this chapter. 26th buildings to build, building spacing requirements shall be governed by the provisions of the fourth chapter of half the spacing of adjacent buildings and request concessions. Gable used to open the window border layout, should be 5 meters and meet the spacing requirements and adjacent buildings down. 27th along city road construction, reconstruction of buildings, Setback distances according to schedule five of the sections building red line control table of concession road. 28th plan width of 25 meters above the range of construction of urban road intersections, concession road distances stated in the section of the red line back down again on the basis of 5 meters. The 29th along the red line width is less than 20 meters of the planned road, on both sides of the building in accordance with the code for planning design of urban residential area (GB50180-93) of the concession, while the request of spacing with adjacent buildings. Article 30th in building large theaters, shopping malls, amusement parks, sports stadiums, exhibition halls and other public buildings, main entrance and exit back road from the red line in the direction of not less than 15 m, and parking, (Editor's Note: this word is formed by multisubunit proteir and back), flow distribution needs. 31st in addition to urban pipeline interfaces on the outside, sewage pipes, walls of the building, structure, Foundation, underground buildings, steps, balcony, canopy, water wells, septic tanks and ancillary facilities into the planned way. 32nd underground border concessions for construction should be built more than 3 meters. Underground buildings city roads should be built after the ground requires concessions of urban roads. Article 33rd in the urban planning region road or highway building concessions on both sides, must comply with urban planning regulations and the regulations of the traffic management Department; outside the urban planning area of towns and villages on both sides of a road or highway construction, concessions distance should conform to the regulations of the traffic management Department, and suitable for isolation as defined by the protection requirements. Article 34th along the mainline road and drainage construction of buildings and structures, according to the Bank of the blue line, trunk sewer protection beyond 2 metres back down. River, and drainage route protection range provides following: (a) nanming river sides protection range by following requirements control: 1, and huaxi reservoir dam to Temple paragraph by planning of river blue line sides 50 meters control; 2, and temple to water mouth Temple bridge paragraph by planning of river blue line sides 20 meters control; 3, and water mouth Temple bridge to Wudang bridge paragraph by River Center line sides 60 meters control. (B) city Xihe River, the River through the city, car, Chen Lianghe, MA di rivers such as the river banks 7 metres of either side of the blue line by planning controls. (C) in yuliang River 50 metres of either side of the blue line by planning controls. (D) the drainage route planning and control of lateral section of not less than 3 m. (E) other rivers in the area of urban planning, drainage lines on both sides of the scope of protection, the Department of City Planning Administration in accordance with flood prevention, urban landscape elements specifically identified. 35th article in railway sides new, and alterations buildings concession distance should meet following provides: (a) in railway route and planning railway route sides construction of, except directly for railway service facilities yiwai, away from side unit track center line of distance not is less than 20 meters; in railway extension, and lines sides construction of, away from side unit track center line of distance not is less than 15 meters; in railway sides built wall of, away from side unit track center line of distance not is less than 5 meters, wall of height not is greater than 2.5 meters. ± 0.00 railway above ground, compromise distance calculated according to the origin under the protection of buildings. (B) construction of high-rise buildings along railway lines, tall structures (towers, chimneys, etc), dangerous goods at the warehouse and yard, setback, in conjunction with the railway management departments before they can determine. 36th civil air defense facilities, construction of buildings and structures in the vicinity, retreat from Guiyang City, according to the relevant provisions of the civil air defense project construction management approach implementation. 37th in cultural relics protection units, cultural relics protection and construction control of heritage conservation zone under construction shall be in conformity with the relevant provisions of regulations on the protection of cultural relics in Guiyang. Article 38th on the airport and related infrastructure construction communications, microwave, its level of collision avoidance distance according to the technical specifications relating to the implementation. The sixth chapter 39th building height control of height of buildings must comply with the sunshine, space, fire protection requirements. 40th building height should comply with the controlled detailed planning, and should be subject to urban landscape planning, urban design, urban planning needs to control the height of the nodes. No height control zones, control building height calculated according to the following formula: where: H--along the way wide building height B--planning b--planning way back the building from the 41st seven and above residential or household entrance floors from the outdoor design height of over 16 meters above ground residential, you must set the elevator. Any of the following circumstances, in accordance with the following provisions: (a) the underlying as store or other premises of multi-storey residential whose entrance floors away from the exterior design of the building you must set the elevator to ground more than 16 meters high. (B) bottom of overhead storage space or multistory whose entrance floors away from the exterior design of the building you must set the elevator to ground more than 16 meters high. (C) the thermocline where the top two levels of a dwelling, the duplex part regardless of the layer. The top household floor from the entrance floor of the exterior design of the building height of not more than 16 meters, no lift. (D) residential middle-tier there is through outside entrances and ground fire channel, the layer can be calculated from the middle tier, total number of nine storeys. 42nd at the airports, weather, radio, telecommunications, microwave communications, satellite earth stations, military facilities and other areas where clearance requirements new, expanded when building, structure, and its height must be in conformity with the relevant provisions. 43rd in cultural relics protection and construction control areas outside the core area and scenic construction, reconstruction of buildings, Guiyang City, its height should be consistent with the cultural relics protection regulations, and the management of scenic spot, Guizhou province, and related provisions. Seventh chapter 44th city pipeline of municipal public facilities should be based on different pipeline characteristics and settings requires a combination of layout, piping between the horizontal and vertical spacing and pipeline and the minimum horizontal spacing between buildings and structures in accordance with the code for urban engineering pipeline comprehensive planning (GB50289-98) control. 45th along city road planning and construction of the underground pipeline to be parallel with the center line of the road, its depth shall be determined in accordance with safety requirements for elevation and pipeline road, sidewalk construction trench within its precast trench cover plates shall not be exposed to ensure pedestrians. Of way width exceeding 30 metres from the main roads, pipelines can be a two-sided wiring. 46th engineering pipeline laying is completed, must be final survey, reported to the competent administrative Department of planning. The 47th new construction, renovation of urban roads shall be in accordance with the code for design of urban road (CJJ37-90) and the following provisions: (a) urban road design and construction shall conform to the planning of way width and vertical elevation. (B) the road longitudinal slope below 5%. Special section of maximum longitudinal slope shall not exceed 9%, design speed and should be based on a variety of grade and slope length. Minimum longitudinal slope should be greater than or equal to 0.5%, difficulty, can be greater than or equal to 0.3%. (C) urban road longitudinal slope shall not be plugged directly into the intersection, there should be transition zone security requirements, within the scope of urban roads intersection longitudinal slope shall not exceed 3%. (Iv) cross-street pedestrian overpasses and buildings, structure clearances shall not be less than 4.5 metres, pedestrian overpass bridge deck width shall not be less than stairway wide; underpass clearances shall not be less than 2.5 m; railway across the pedestrian bridge clearance, buildings and structures shall be not less than 6.5 meters. (V) construction of urban elevated road and light rail road, the Highway passes the sound barrier facilities should, some noise-sensitive buildings area. (F) road, the pavement along the height shall not be less than 0.2 m. (VII) construction, reconstruction should be set according to the specifications of urban road blind, such as barrier-free facilities to the disabled. (VIII) special topography, location of city road construction, the Department of City Planning Administration in accordance with the relevant provisions. The 48th new, rebuild city bridges according to design specifications and subject to the following provisions: (a) the construction, reconstruction bridge way wide of the net width should not be less than planned. (B) bridge design should consider the pipeline through, flammable, combustible piping should not be using traffic bridges across the river. (C) the Division should be consistent with the road cross section cross section of the bridge. 49th city planning new construction, old city reconstruction of the area, shall be indicators to be provided in the following area planning in environmental sanitation: (a) public toilets set 1, 6~10 square meters of residential/in thousands. 2, station, airport, Stadium (library) by distributing the stream 15~25 square meters, gas stations and farmers ' markets/people. 3, shopping, culture and entertainment center 10~20 meters/thousand people. 4, public toilet separated by distance or scope of services: distance between the main busy street public toilet for 300~500 metres, streets with high-density population should be less than 300 m, about 750~1000 metres distance between the normal Street public toilet, not reconstruction of old residential area of 100~150 meters, the new residential areas of 300~500 m. 5, 2500~3000 sets a public toilet, building area of 30~50 square meters. (B) solid waste collection points set 1, domestic waste collection service RADIUS less than 70.1-meter, with an area of not less than 40 square meters, the buildings surrounding the interval of not less than 5 m. 2 the set interval, waste cans: Street 25~50 meters; roads 50~80 m; road 80~100 m. 3, refuse collection points should be set up in both convenience and do not affect the appearance of a street location. (C) refuse transfer station, dump 1, the small station sets each 0.7~1 square kilometers, with an area of not less than 100 square meters, the buildings surrounding the interval of not less than 8 m. 2 sets each 10~15 square kilometers, medium and large transfer station, the land area is determined according to the rolling capacity, as described in Schedule VI of the medium and large garbage transfer station scale control table. 3, yard municipal solid waste should be set in suburban areas, to be selected location should pay attention to urban wind out of city water source protection areas and areas of geological hazards. Junk yard fences, roads, landscaping and management should be set using room should have environmental protection measures time not less than 10 years. (D) car wash in roads into the city, suburban settings, car wash and small car wash in the city, in accordance with the principles of unified planning, rational distribution, shall conform to the relevant provisions of the environmental protection and sanitation. 50th city parking lots (garages) should be performed with the following provisions: (a) public buildings, public facilities and one or two houses according to the Schedule table of seven indicators of the parking regulations. (B) parking lots (garages) should be based on the nearest location, land conservation, the principle of making use of terrain, suitable for underground or multi-storey parking garage. (C) motor vehicle parking entrance, the driving range of requirements, and the right of access lanes. (Four) parking out entrance should distance people line overpasses, and authentic and bridge, and tunnel ramp start line 50 meters beyond; 50 a spaces following of parking can set a access mouth, net width not is less than 7 meters; 50~300 a spaces of parking, should set two a out entrance, out entrance distance should is greater than 20 meters; is greater than 300 a spaces of parking, export and entrance separate set, two out entrance distance should is greater than 20 meters. (E) parking lots (garages) should be designed according to the Ministry of public security, Ministry of construction, [88] Gong (Gong Guan) no 90th rules of car design (trial) implementation. 51st service stations of urban public, should be 0.9~1.2 km radius of gas station services, general layout and architectural design of urban landscapes, traffic, fire department requirements. 52nd City City fire equipment, fire station set up, in accordance with the relevant standards. 53rd install outdoor advertising facilities shall conform to the following provisions: (a) should not be used suspended advertising. (B) outdoor advertising shall not block the city landscape, urban greening, landmarks, transport facilities, Memorial building, party and Government organs, cultural relics and historic sites and urban comedy, should not affect the adjacent buildings, lighting, ventilation, traffic, fire. (C) not isolation from the Center railings and the road vehicle turn depending on range setting. (D) install outdoor advertising facilities, Guiyang in conformity with the relevant provisions of the conditions. 54th in the urban planning area of urban roads, squares, parks and other public places to construct the city sculpture must comply with urban planning and coordination with the urban landscape, the environment. Urban green 55th in the eighth chapter of urban road greening rate shall comply with the following provisions: (a) landscape road greening rate shall not be less than 40%; red line width is greater than 50 meters of road greening rate shall not be less than 30%; red line width of 40~50 meters of road greening rate shall not be less than 25%; red line width of less than 40 metres of road greening rate shall not be less than 20%. Road layout, planting trees of green belt width shall not be less than 1.5 m; on trunk road green belt width not less than 2.5 metres; trees green belt width shall not be less than 1.5 m. Rebuilding roads in the old city, where appropriate, reduced, but not below the green rate, half of the indicators mentioned above. (B) the island green of the Centre shall maintain the permeability of the intersection between road sight. (C) the public square should be planted around tall trees. Concentrated into green spaces should not be less than the total square area of 25%. (D) in station, dock, airport terminal square planting local species should be chosen. Concentrated into green spaces should not be less than the total square area of 10%. (E) parking lot plant height under the shade tree branches should be consistent with the provisions of parking space clear height: 2.5 m for small cars, midsize car for the 3.5 m, truck is 4.5 meters. (Vi) green belt when overhead lines must be set above the street trees and green belts, guarantee overhead line is not less than 9 metres of trees to grow. Overhead trees should be selected that are configured under an open canopy or trimming trees. (G) the trees green and with no pipelining, the minimum horizontal distance from trees and other facilities shall comply with Schedule VIII of the trees and other provisions of the minimum horizontal distance from the control table. 56th of residential area (a) newly-built residential areas, living quarters, housing cluster configuration in accordance with the norms of urban planning and design of green space (GB50180-93) requirements. (B) green space in residential area, next to the scale configurations include public green space, green, matching public-owned green space and green space. (C) the ratio of green space: new construction should not be less than 30%, redevelopment should not be less than 25%. (D) setting, the following provisions of the public green: green setting for a group shall meet not less than 1/3 of green areas in building Sun shadow line beyond the requirements of the standard, and easy to set up children's play facilities and adult recreation activities. (E) the index of public green space in residential areas should be based on the size of the resident population, respectively: not less than 0.5 square metres per person for a group, community (including groups) not less than 1 square metre per person, residential area (including communities and groups) not less than 1.5 square metres per person, and shall be arranged according to the planning and organizational structure types, flexible use. Transformation of old urban areas can be reduced, as appropriate, but shall not be lower than the target of 70%. 57th new industries and other green space the following control indicators of civil execution: (a) Administrative Office greening rate of not less than 35%. (B) financial and commercial green rate of not less than 20%. (C) cultural, recreational, hotel green rate of not less than 35%. (D) schools, research green rate of not less than 35%. (E) industrial corporate greening rate of not less than 30%, polluting industries and implement project green rate, according to the green rate. Article 58th plan of green land, no units or individuals shall not be allowed to change of land use, not illegally occupied. Nineth chapter supplementary articles article 59th of violations of the provisions of this Act, Guiyang City, in accordance with the relevant provisions of the Town Planning Ordinance penalized. 60th before the implementation of the provisions of constructional detailed planning and design was not approved, detailed construction planning programme has validated but does not report individual programme, detailed construction plan and architectural design has been approved but have not yet applied for the construction project planning permit (copy) project, according to the regulations. 61st these provisions come into force on April 1, 2004. Published on October 28, 1997 Guiyang municipal urban planning and management of the technical regulations in force be repealed simultaneously. Table: range of all kinds of construction land and built a table note: allow setting; x does not allow setting; 0 allows or does not allow to set, by the Guiyang City Planning Bureau determined according to the specific conditions and requirements. Schedule II: building density and volume control indicator table notes: 1, building density and volume control indicator in the table top. 2, 100 meters above the high-rise public building density and volume control indicator according to the requirements of urban landscape by the Urban Planning Department determined. 3, Center within the loop: from Jiefang road, Po Shan Road, street, Wun Sha Lu, ZAO Shan Lu, Beijing Road, enclosed city limits and along the outer ring road outside the red line depth 50 meters of building land. 4, outside the Centre ring road: means "center ring" other than the range and scope of jinyang town. Schedule III: provides open space area control list in schedule four different azimuth spacing reduction coefficient table notes: 1, direction South (0 °) azimuth between East and West. 2, l as standard insolation interval to the House just south of Guiyang. 3, the table only applies to no other sunshine between the parallel arrangement of block apartments. 4, insolation interval based on the South side, East of the building height calculation. Schedule Friday: road concession buildings on urban road line control table notes: 1. the figures in the table for the control of lower value. 2. the concession from the building, a building and building overhang along the road side of the real projective line. Schedule VI: large waste transfer station scale control of schedule VII: parking index table notes: 1 the table spaces to cars as standard units. 2, the first category refers to foreign-related hotels, hotels of the second category refers to domestic passengers. 3, a class office building refers to the Central and provincial authorities, trade organizations and foreign offices. B class office buildings to other organisations. 4, seating more than 4000 seat stadium and seating more than 15000 seat stadium for sports (field) Museum, the other for two sports (field) Museum, Stadium parking spaces below the Stadium parking. 5, a kind of cinema refers to the province, the Municipal Theater and other theaters for the second class. 6, a tourist place refers to the classical gardens, scenic. Class II touring places general urban park. 7, a residential home senior housing as well as foreigners, overseas Chinese, compatriots from Hong Kong and other residences. Two residential houses. 8 1/10 can be converted to trolley, bicycle indicators indicators. Schedule VIII: trees and other facilities Appendix a glossary the minimum horizontal distance from the control table 1, building volume rate: within a certain block, ratio of total floor area and building area. 2, building density: all buildings within a certain plot basal area percentage in construction area. 3, residence: layer 1-3 layer houses. 4, multistory: layer 4-6 layer houses. 5, senior housing: layers for 7-9-storey house. 6, high-rise residential building: layer is equal to or greater than the 10-story residence. 7, building construction: total height over 24 meters of public buildings less than 100 metres from the building. 8 super high-rise building: total height of more than 100 metres from the building. 9, building line: refers to the planning and construction of lines and size of the bounding box, as well as planning and architecture outside the box line and the adjacent City Road, next to control labeling of architectural space. 10, road line: refers to planning and road cross section of two control lines. 11, channel blue lines: two line of planning the river cross section. 12, the green line: green cross line of control. Appendix II rules 1, land area in urban planning administrative departments in delineating the land areas deductions planned red line of urban roads and rivers, drainage route planning, land for the construction of the blue line. Planned red line of the road and river, drainage route planning are not accounted for in the construction of the blue line to participate in building capacity index calculation. 2, the building area is calculated for each layer of the architecture is the projection area with overhanging balcony of the 1/2 area and 2.2 meters above the thermocline is projected area for the area. Basement, half of not more than 1.5 m above ground level basement, a free height below 2.2 metres semi basement, roof water tanks, the elevator control room, out of the roof of the staircase, column-free rain canopy, Colonnade, height 2.2 metres in suspending the aerial layer, height below 2.2 metres of mezzanine and equipment, the planning area at all. 3, the building volume rate and building densities (1) commercial and apartment building volume rate according to the different nature of the proportion of floor space, according to (ii) conversion of targets set by synthesis. Its density (table II) provides indicators of the implementation. (2) commercial/residential or office building, such as the commercial area or Office area of less than the total area of 10%, used for all residential area calculation of volume rate, its density is calculated according to the business or Office. (3) no podium ground floor for commercial or Office or apartment building, its plot ratio, density of buildings on a residential basis. 4, open space and calculation (1) in the scope of construction land, provide the public with effective use of the ground square, sunken Plaza, roof terraces, green areas, parking (garage) and other public use of indoor and outdoor space. (2) must be open space along the city roads, plazas, in either direction should be more than 8 meters in depth, usable floor area of not less than 150 square meters, and not greater than 5 metres in height difference on the ground, should set the corresponding flag of open space, has a direct access ramps or stairs to do open all the year round, not to mention changing the nature, and submitted to the relevant Department. (3) the calculation of the effective area of open space: according to the effective provision of social services area, increases the area by allowing the control coefficients in the table, increasing the floor area shall not exceed the approved gross floor area of 25%. 5, building height calculation (1) flat roof without parapet roof from outside is ground to the top of the cornice and parapet roof is to the top wall of her daughter. (2) the slope roof building, measured from the ground outside to the roof. Buildings, from outside is ground to the top of the sloping eaves. (3) stairways, elevators, water tank on the roof, chimneys, roof decoration of buildings as building height calculation, such as clearance or other control height requirements, the Department of City Planning Administration approval. 6, building space calculation pitch is the horizontal and vertical distance between the two buildings outside the walls. Calculated according to the fourth chapter of regulations. 7, the floor number of building a free, height over 2.2 meters count on the free surface of the first layer to the roof of a building. Height 2.2 metres hanging feet overhead, height below 2.2 metres of mezzanine and equipment and jumped on the top layer does not calculate the Number of floors. 8, range calculation of urban road intersections from the planned red line line computed from the connection point for a curved segment, calculated according to the road grade, imported lane Linear length of 50 m to 80 m, exit lane line from 30 m to 60 m in length.