Advanced Search

Chongqing Municipal People's Government To Amend The Decision Of The Technical Regulations For Urban Planning Management

Original Language Title: 重庆市人民政府关于修改《重庆市城市规划管理技术规定》的决定

Subscribe to a Global-Regulation Premium Membership Today!

Key Benefits:

Subscribe Now for only USD$40 per month.
(February 8, 2006, Chongqing Municipal People's Government for the 67th General session on February 27, 2006, Chongqing Municipal People's Government promulgated as of April 1, 2006, 193th), Chongqing Municipal People's Government decided to make the following changes in technical regulations for urban planning and management: the 11th amendment as "building volume rate refers to the ratio of above ground area and building area.     Building volume rate calculation formula: where: FAR-building volume rate s-s ____ construction above ground area 1 area 2 notes: 1. calculation of the floor area in accordance with the standard measurement for construction area (GB/T50353-2005).     2. above ground area refers to the total land area after discounting the basement area of the building area (refers to the construction land within underground building, outdoor flooring design elevation of buildings around and completely buried part, the parts of the construction area of the basement area). 3. the use of underground space should be strictly in accordance with national and relevant regulations and technical standards to strengthen management in Chongqing.     "This decision shall enter into force on April 1, 2006.       The technical regulations for urban planning management under this decision be revised and republished.     Appendix: technical regulations for urban planning management (revised 2006) Chapter I General provisions article to strengthen urban planning and management, ensure the implementation of urban planning, according to the People's Republic of China urban planning law, the urban planning regulations, the Chongqing Municipal master plans and related laws, rules, regulations and norms, these provisions are formulated.     Article in the formulation and implementation of urban planning in the administrative area of the city, engaged in activities related to the urban planning construction and management, must comply with this provision.     Article III the preparation of detailed plans (including controlled detailed planning and detailed construction plans, the same below) shall comply with the provisions of, and, according to procedures approved by the right authority, and that can be implemented.     Second chapter construction with to fourth article this city construction with to, by its main uses and function partition of principles, reference city with to classification and planning construction with to standard (GBJ137 – 90) classification following: (a) live with to (r); (ii) public facilities with to (c); (three) industrial with to (m); (four) warehouse with to (w); (five) foreign traffic with to (t); (six) Road square with to (s); (seven) municipal public facilities with to (u);     (VIII), green (G) and (I) special land (d).     Article fifth nature of the various types of construction land according to the approved detailed plans of implementation, its compatibility tables shall comply with the provisions the provisions of the building content of various types of land suitable to build a table.     Sixth chapter plot control in addition to public facilities and urban infrastructure facilities, construction sites in the transformation of the old city area of 1000 square meters, a new area of 2000 square meters, not a separate construction.     Seventh building with an area of less than 20,000 square meters of construction projects, building bulk rate table II and the density of buildings according to the provisions of the building volume rate, building density index form (hereinafter referred to as the ' II) control.     Eighth section greater than or equal to 20,000 square meters of building area, or particularly important construction project of building land, you must first prepare a detailed planning and urban design, the building volume rate and building density, determined by the approved detailed planning and urban design.     Nineth not included in table II of the research institutes, colleges, schools, sports facilities and health, cultural arts, childcare facilities building volume rate and density control, you should do the provisions relating to professional design and specification, but must not be greater than the control index for residential buildings in table II. Tenth land red line drawings of the figure is the site of the construction project submissions. Construction land red line must be drawn on an 1:500 situation map, must draw on planning, land line, demolition range line, road, construction of the red line red line and green line, municipal facilities, water systems, cultural relics protection and coordinates-qualified.     Must indicate on the azimuth of the run-ins or location.     Building land lines, planning the range line, demolition range line must be closed, its calculation to square meters.     Article 11th building volume rate above ground area and the ratio of building area.     Building volume rate calculation formula: where: FAR-building volume rate s-ground construction area for building area of 1 s-2 notes: 1. calculation of the floor area in accordance with the standard measurement for construction area (GB/T50353-2005). 2. above ground area refers to the total land area after discounting the basement area of the building area. (Refers to the construction land within underground building, outdoor flooring design elevation of buildings around and completely buried part, the parts of the construction area of the basement area.     ) 3. utilization of underground space should be in strict accordance with national and relevant regulations and technical standards to strengthen management in Chongqing.     12th building density refers to all buildings on the block a total projection area ratio of building area (expressed as a percentage).            Construction density calculation formula: where: d-the building density; s-building area; 2 s-architectural projection area.     3 architectural projection calculation of total area: Besides awnings, eaves, parts of buildings outside the framework of horizontal projected area are included in the construction total projection area.     13th article is located in City Green protection ban built district edge, or city road side of plots, in its demolition range or land range within for Park, and green belt, public green provides has with to of, city planning administrative competent sector can according to its contribution size and may, in prepared detailed planning or issued design conditions Shi, on building volume rate, and building density, and green rate, index be corresponding adjustment. 14th in the building within the projection area, along the urban road and square set, provide the public with open all day long, free and convenient direct access to, and the actual area of not less than 150 square metres square, green spaces and other spaces, be regarded as public open space.     Functional requirements of buildings and open spaces, not as a public open space.     For social public provides public open space, can corresponding increased area: (a) approved building volume rate is less than at 2 o'clock, each provides 1 square meters open space, allows increased area 1.2 square meters; (ii) approved building volume rate is greater than is equal to 2 and is less than at 4 o'clock, each provides 1 square meters open space, allows increased area 1.5 square meters; (three) approved building volume rate is greater than is equal to at 4 o'clock, each provides 1 square meters open space, allows increased area 2 square meters.     Increased floor space totals may not exceed the approved total floor area (building area multiplied by the approved building volume rate) 5%.            15th article in the transformation of the old city, which can bear the relocation area, basic building volume rate can be increased according to the following formula: where: FAR-basic volume; 1 increased FAR-far; 2 s-building area; 2 s-units area.     4 basic building volume rate increase shall not be greater than 1.0.     16th measurement for each design stage area are calculated according to the relevant area of the State rules.     Construction design stage in favor of programme area increase shall not exceed 1%. 17th new construction, renovation or expansion of the building must be provided parking spaces.     The number of parking spaces determined by the area, at least set 1 parking space per 300 square meters of residential buildings, at least set 1 parking space per 200 square meters of public buildings; among them, the parking space shall be not less than 10% of total parking spaces on the ground.     Fourth chapter building spacing 18th new construction, renovation or expansion of building space, must comply with the provisions of the articles of this chapter. 19th article adjacent residential building, main lighting surface relative parallel layout Shi of spacing: (a) 8 layer and the 8 layer following, or calculation height is less than or is equal to 24 meters, residential main lighting surface Zhijian of distance: old city transformation district not is less than average height of 0.8 times times, new district not is less than average height of 1 time times; (ii) 9 layer and the 9 layer above, or calculation height is greater than 24 meters, and width not is greater than 40 meters (containing 40 meters) of residential main lighting surface Zhijian of distance: old city transformation district not is less than 24 meters,     New area of not less than 28 meters; (c) 9 and 9 storeys or height greater than 24 m, width greater than 40 meters distance between residential daylighting mainly, according to this article (a), of the regulations, calculating the height of more than 100 metres from the building executed in the calculated height of 100 meters. 20th article adjacent residential building, main lighting surface vertical layout Shi, outside wall surface and demolition range line or with to border of distance, in not is less than chapter other the article provides spacing 0.5 times times of conditions Xia, its spacing for: (a) 8 layer and the 8 layer following, or calculation height is less than or is equal to 24 meters, residential main lighting surface and another a building residential gable Zhijian of distance: old city transformation district not is less than 8 meters, new district not is less than 12 meters; (ii) 9 layer and the 9 layer above, or calculation height is greater than 24 meters, and     Width not is greater than 40 meters (containing 40 meters) residential main lighting surface and another a building residential gable Zhijian of distance: old city transformation district not is less than 12 meters, new district not is less than 15 meters; (three) 9 layer and the 9 layer above, or calculation height is greater than 24 meters, and width is greater than 40 meters of residential main lighting surface and another a building residential gable Zhijian of distance: old city transformation district not is less than 15 meters, new district not is less than 18 meters; 21st article adjacent residential building, main lighting surface both not parallel, also not vertical layout Shi of spacing:     (A) when the angle is less than or equal to 60 degrees, at one point is determined by the 19th, (ii) angles greater than 60 degrees, at one point is determined by the 20th.     22nd article adjacent residential building, angle and angle relative layout Shi of spacing: (a) two building building are for 8 layer and the 8 layer following, or calculation height are is less than or is equal to 24 meters Shi: old city transformation district not is less than 8 meters, new district not is less than 12 meters; (ii) which of a building or two building building for 9 layer and the 9 layer above, or calculation height is greater than 24 meters Shi: old city transformation district not is less than 12 meters, new district not is less than 15 meters.     23rd the distance between adjacent Gables two blocks of residential buildings: the transformation of the old city area of not less than 6 metres, the new area is not less than 8 m. 24th two Gables residential buildings have no Windows, can be connected to the construction, but the connection must be in accordance with the regulations.     New residential buildings cannot be built with residential docking slot, but could be wrong.     The width of the two buildings after the connection, calculated according to the whole building.     25th adjacent residential ground floor elevation is inconsistent (in adjacent houses in another building where a roof elevation below the bottom elevation), the distance between the two, according to the 19th to 23rd of regulations.     26th rock residential daylighting and Fort sill height greater than 1 m when, distance between the bottom sill and Fort Sill, shall not be less than 0.4 times times Fort sill height, and shall not be less than 3 meters.     When the 27th when the floor is irregular, with the elevation profile width of width instead of extension cords to form and to calculate the width, as provided for in article 19th to 25th respectively determine the spacing requirements.     28th main lighting of the building and another building when part of the main lighting does not have Windows, or two buildings when part of the main lighting does not have Windows, are seen as the main lighting main lighting and surfaces.     29th balcony shall not be occupied building space.     30th the building back to Taiwan, according to the provisions of articles from 19th to 29th, depending on their different heights separately determine the spacing. 31st article other various building of spacing, should comply with following provides: (a) new, and expansion of school teaching floor, and kindergarten building, and hospital ward mutual Zhijian of distance, and and adjacent building, and Fort Kan Zhijian of spacing, except should meet corresponding of design specification, also should in 19th article to 30th article provides of based Shang increased 3 meters; (ii) new, and expansion of public building, and industrial building, and warehouse building and apartments type Office, and residential building mutual Zhijian of spacing, except should meet corresponding of design specification outside,     Provisions of article should also conform to the 19th to 30th, (iii) construction, expansion of public buildings, industrial building, warehouse construction spacing between each other, should conform to the functional requirements and design specifications.     32nd new construction, renovation or expansion of the building (structure) of the external walls of buildings and demolition range, or distance between the land border line shall be not less than the 19th, 21st to 31st article spacing of 0.5 times times border has a permanent building (structure) while article should also conform to the 19th to 31st all spacing requirements. 33rd Street Setback in the transformation of the old city planning road red line, average yield distances greater than 8 m, and larger than planned total road width 1/3, causing permanent with the rear spacing between buildings is low, its spacing can be appropriately narrowed.     Narrow intervals of not greater than the retreat from 1/2, and reduced distance shall not be less than 0.5 times of the 19th through the 31st article space.     Build rear building, location of the spacing should be required to stay away from the building.     The fifth chapter buildings should concede the 34th Street building way back down on the basis of the following criteria: way back not less than 1.5 m; secondary road back not less than 3 m; p main road back not less than 5 m.     Special building way back the distance according to the following standards: high-rise building height greater than 60 metres, give way to the main building: the way back not less than 3 metres; secondary road back not less than 5 m; p main road back not less than 7 m.     New theaters, amusement parks, sports stadiums, exhibition halls, shopping, star hotels, large crowds, traffic distribution architecture, its main entrance facing urban roads, back roads planned red line distance, the Department of city planning administration according to the requirements of urban planning, but not less than 8 m. 35th Street parallel to the main and secondary road layout of panel buildings (including high-rise building annex), its height (starting from the sidewalk elevation) must not be greater than planning road centerlines along the width between the outside the building twice.     Above the width of the part should be building along the corresponding scaling back. Street parallel to the road layout of panel buildings (including high-rise building annex), its height (starting from the sidewalk elevation) in the new area shall not be greater than planning road centerlines between and along the exterior width twice times in the transformation of the old city area shall not be greater than road centerline and between buildings along the width of 2.5 times.     Above the width of the part should be building along the corresponding scaling back.     Frontage roads parallel arrangement of high-rise buildings, the window surface distance from the center line of the road, in the reconstruction of old city area shall not be less than 12 metres, in the new area shall not be less than 14 metres.     36th at 16 m and 16 meters above the buildings of city road intersection corner back road planned red line distance, in addition to the provisions outside of the 34th, 35th, and also have to make more concessions.     The 37th new construction, renovation or expansion of the building (structure) the sidelines are public green spaces, playgrounds, schools, kindergartens, hospitals, and the distance to the edge of the wall, in the fourth chapter of architectural space should be increased on the basis of the relevant provisions of 3 meters.     38th article other than urban infrastructure construction, reconstruction, expansion of the building (structure), along the road layout, its underground (structure) are not allowed to go beyond the building line.     The 39th new construction, renovation or expansion of the building (structure) of underground parts of buildings and the distance to the red line, must meet the safety requirements, and shall not be less than 3 meters. 40th article Street building wall outside facilities of set, should meet following provides: (a) outsourcing column, and vestibule, and stepping, and flower bed, and lighting well, and window, and sewage processing facilities,, shall not beyond building red; (ii) lane variable slope line, and engineering internal tube network, shall not beyond road red; (three) rain canopy, and pick eaves, and balcony, and signs external wall facilities, dang its lower away from outdoor ground clearance height is less than 3 meters Shi, shall not beyond building red; Dang clearance height is greater than, and is equal to 3 meters Shi, can beyond building red,     But they shall not go beyond the way. Chapter Sixth green control 41st all construction within the Green lands area occupies an area of (the green rate), shall comply with the regulations of the urban landscape of Chongqing and other indicators of the relevant provisions.     Among them, the green rate not lower than 25%, transformation of the old city district, new urban green space rate is not less than 30%.     42nd concentrated green space within building land, concentrated green space construction land shall not be less than the total area of 10%.     43rd construction land according to plan a saving of natural water bodies, according to the design to control water level line up should set aside no less than 5 m wide green belt.     44th section roof, platform green building (structures) subsidiary of greening, not included in the ratio of green space.     Article 45th urban green space within the prohibited area, no construction project regardless of the Green, but of pipelines and ancillary facilities, except with permission.     Green space within the control area, only in low-rise buildings, green space rate shall not be less than 60%, the building density no higher than 20%. Seventh chapter special with the 46th special land referred to in this chapter, refers to the land-use planning and management with special requirements.     Construction carried out in these areas must meet the requirements of their protective plan.     47th air Hong Kong, weather stations, radio and TV transmitters and radio communications (including communications) and monitoring facilities around the building, rebuilding, expansion of building (structure), and its height shall comply with the provisions relating to clearance protection control. 48th overall urban planning, Chongqing should be in accordance with the relevant provisions of, to protect the city skylines.     Construction, reconstruction and expansion of city skylines and also building (structure), its height and volume must be subjected to rigorous scientific and expert review.     49th urban traditional blocks should be protected, its streets and homes fit for demolition, but should maintain the traditional pattern of streets and architectural style, should be focused on the protection of ancient buildings with heritage value.     Protection of historical and cultural relics protection areas, historical sites and influential and modern buildings should be in accordance with the law on cultural relics protection and the relevant provisions of the urban master plan for protection.     50th at all levels, and there are provisions on the protection of cultural relics protection units around the building, building, rebuilding, expansion of building (structure), its architectural form, height and distance, shall conform to the protection plan, or other relevant regulations.     Geological hazards in the 51st was prohibited in the district, in addition to the treatment of dangerous rock masses, greening and essential municipal projects, other construction activities is strictly prohibited. Wary of the area of geological disasters, we will strictly control construction activities.     Where applications for siting in the caution area, must be preceded by risk assessment of geological disaster of construction land, and reviewed by the relevant departments identified. 52nd all construction activities, deep excavation of high cutting slope should be avoided.     Needed, construction of deep excavation of high cutting slope projects should be strictly in accordance with the urban planning administrative departments and municipal construction Administrative Department of the relevant provisions. 53rd original topography shall prevail, ten year flood level of river flood diversion work.     In the main building built in flood diversion work is prohibited (structures), construction of the necessary engineering structures must be demonstrated. Ten-year flood levels above and below the 20-year flood level for restricted use zone. Within the restricted zone, no building effects of flood water building (structures).     Construction of flood control standards according to national standards (GB50201-94) implemented.     Eighth chapter municipal and 54th in the highway on both sides of the pipeline building, rebuilding, expansion of construction works, building the red line 50 metres distance from the outer edge of the shoulder of the road, between shoulder and a building for the road protection zone.     If width of old city reconstruction project with necessary adjustments should be demonstrated by the municipal urban planning administrative departments, and its width shall not be less than 36 metres.     Shelter belt in farming, afforestation, greening, digging ponds through handle construction project planning permit (or a temporary permit), also set up road, laying of pipelines, roads, parking lots, municipal facilities and public toilets and refuse collection points as well as the engineering facilities of highway. 55th article along railway sides new, and alterations, and expansion construction should meet following provides: (a) except railway management required of few built (frame) built colonization,, in railway route sides of built (frame) built real, its outside line and most outside side rail of distance not is less than 20 meters, railway extension, and lines sides not is less than 15 meters; (ii) in railway route sides built senior building, and tall structures (as towers, and chimney,), and may endanger railway transport security of built (frame) built real, and dangerous goods warehouse and plant,     Dang its construction with to into distance most outside side tracks 30 meters within, and track of distance must by argument Hou determine; (three) railway sides 20 meters within built wall, its height shall not is greater than 3 meters, and most outside side rail of distance shall not is less than 10 meters; (four) involved railway crossing, and bridge, and tunnel, and his sections of design, must meet railway management of about provides.     56th building, rebuilding, expansion construction on both sides of the River, and may seize the main flood section.     The main river of the city major, major tributaries and water surface should be strictly protected. (A) except built road, and bridge can across outside, ban seal cover; (ii) in river sides and water around, should by provides left out sewage interception pipeline and green with of location, and for people line or car of road with to and public green; (three) new, and alterations, and expansion construction, its building sideline from main flood diversion work edge of distance shall not is less than 20 meters, its flood control design also should meet corresponding flood control standard of requirements; (four) in according to water administrative competent sector recognized of flood control standard Canal of Hou of river sides new, and alterations , Expansion of the building works, the building edges and Canal wall distance shall not be less than 20 meters.     There are lots of special provisions, those provisions; (v) the piping shall not be laid forward in the Honghe road on the main line, horizontally crossed the River, and shall not impede the river flood.     57th existing urban land use in the planning of urban road outside the red line, in the plan until the roads, land for construction of related construction projects shall not exceed the planned way, and concession buildings should also be in accordance with the relevant provisions of the existing city road.     Article 58th in planning, construction on the Yangtze River and jialing River Bridge must be determined according to the approved feasibility study report of the bridge's security control area and control requirements, planning control.     Construction of the bridge, each must be bridgehead building not less than 30000 square meters of public green space.     For existing bridges, safety management area should be required to protect its land within the security zone, with the exception of the bridge maintenance required facilities, no new building (structures).     59th planning urban primary and secondary roads, parking should be arranged for the use of public transport vehicles in Hong Kong. Parking space in Hong Kong should be on the same side as the 500 metres to 800 metres.     Hong Kong harbor-parking line shall be not less than 25 m in length, of a width of not less than 9 metres; dash parking line in Hong Kong should not less than 15 m in length, of a width of not less than 3.5 metres.     60th new construction, alteration, extension has a great demand for passenger traffic, the large public buildings, should be set in the context of its land dedicated minibus waiting buses road, each waiting bus width should not be less than 3 meters, each lanes length should not be less than 30 m. Over 61st planned 4 lane urban road intersections in import and export, bi-directional broadening should be set. Stretching the length of the curb radius endpoint for the 50-80 meters.     Spreading width should not be less than 3.5 meters.     Construction land in the 62nd when the roads and urban roads converge, the grade change point must be located in the building of roads within the red line. 63rd in the city to meet the needs of public transport on the roads when erecting pedestrian bridge, flyover should be 3.5 to 4.5 meters wide, and headroom under bridges shall not be less than 4.8 m.     Under the bridge and stairway, and are not allowed to set the operation of facilities and other facilities not connected with pedestrian traffic.     64th design of urban roads, must adhere to the relevant provisions in the provision of barrier-free facilities.     65th new construction, renovation or expansion of the building (structure) Foundation and the existing water supply, drainage, gas pipes (Gou) road-distance shall be not less than 3.0 metres, with power cables or pipelines already in place, communication cable or the pipeline distance should not be less than 1.5 m.     66th in a 220,000-volt and below voltage near overhead power lines, building, rebuilding, expansion of the building (structure) of the works, and should be required to set aside the distance between overhead power lines.     In meet about legal provides and the technology specification of conditions Xia, built (frame) built real of outside line, from has has overhead power line side wire of minimum level distance: (a) 1000 v to 10,000 v of not is less than 5 meters; (ii) 35,000 v to 110,000 v of not is less than 10 meters; (three) 154,000 v to 220,000 v of not is less than 15 meters; in city planning district within of building intensive district, built (frame) built colonization, sideline, and has has overhead power line roadside wire of level distance, can reduction to following numerical.     (A) 1000 v to 10,000 v of for 3 meters; (ii) 35,000 v to 110,000 v of for 4 meters; (three) 154,000 v to 220,000 v of for 5 meters; in voltage grade over 220,000 v of super high pressure overhead line sides, new, and expansion built (frame) built real engineering, and the overhead line of spacing, must by argument Hou determine. 67th new construction, renovation or expansion of overhead power lines, and the vertical distance between the existing buildings, shall comply with the relevant national legal requirements and design specifications. In city planning district, its wire in maximum calculation arc vertical conditions Xia, and status ground of vertical distance should according to city planning of requirements appropriate increased: (a) 1000 v to 10,000 v of not is less than 9 meters; (ii) 35,000 v to 110,000 v of not is less than 15 meters; (three) 154,000 v to 220,000 v of not is less than 18 meters; 68th article new, and alterations, and expansion construction engineering Shi, itself should configuration of subsidiary equipment with room and the facilities (as: power opening and closing by, and distribution room, communications, and Unicom, and wired TV, and     Transfer of audio and video information network of computer networks, natural gas pressure regulating or pressure regulator, water pumping stations, tanks, water tanks, water meter, refuse collection, sewage treatment tanks, etc), and may not go beyond the building line; combined fire, fire hydrants, outdoor fire ring, all kinds of checks, such as any excess of way. On the 69th in new City Road, distance from the curb of street trees, generally not less than 2.5 m. Various pipelines and roadside trees road greening and manpower arrangement.     Grassland on the pavement and municipal engineering pipelines (line) composite layout.     Urban utility piping (water supply, sewage, electricity, gas, water, street lights and traffic) in bilateral arrangement of urban road and its arrangement see tuyi (schematic); single sided layout, its arrangement see figure II (schematic).    Roadway width of 4-lane when on shall be positioned on each side of the road drainage. New city roads should be building multiple pipelines (line) shared common tunnel. Under a variety of City Underground pipelines should be placed on the sidewalk.     When the pipe or manhole plane size is large, pipes along the interface with little or no interface, can also be arranged under the roadway.     70th article in city main, and times road in the laid pipeline, must according to city planning requirements of scale laid, except temporary construction pipeline and straight buried power, and communications cable outside, shall not less than, and is less than following number and the scale: power cable many Yu 6 article, audio and video cable many Yu 6 hole, gas pipeline diameter not is less than 100 mm, water pipeline diameter not is less than 200 mm, drainage pipeline diameter not is less than 400 mm.     71st underground pipeline lateral when they cross the roadway, the overburden thickness should satisfy the relevant technical specifications, and shall not be less than 0.75 m.     Curb along city roads laid low voltage power lines of the city public lighting system, its covering thickness of not less than 0.5 m.     Parallel to the center line of the road laid underground piping (line), its covering thickness shall meet the minimum technical regulations for overburden, and shall not be less than 1 m.     Installing pipeline trench under the sidewalks, decorative roof and sidewalk paving should be unified, the top level should be consistent with the sidewalk elevation.     Ancillary facilities such as manholes, hand holes, the top level should be consistent with the ground elevation. 72nd road in the city, if you need a new 110,000-volt voltage of high voltage power pole and above Road, must be demonstrated and approved by the relevant municipal departments for examination and approval.     On city streets, are not allowed to establish other new overhead line pole road.     New settings of power transformers, communication junction box, gas regulators (box) facilities such as the occupation of urban road pavement is not allowed.     Overhead wires and facilities on the existing sidewalks should be combined with road reconstruction, according to the requirements of this article gradually standardized.     Nineth chapter supplementary articles article 73rd dangerous reinforcement crisis project, does not apply to the technical regulations, the Department of City Planning Administration in accordance with the relevant provisions.     74th district outside of the urban planning area of this municipality (autonomous counties and municipalities) people's Government in accordance with the Ordinance and the regulations for urban planning management, work out the implementation details, after review by the city planning administrative departments, and submitted to the municipal people's Government Executive. 75th before the implementation of these provisions, in accordance with the relevant provisions of the urban planning regulations approved by the various stages of the programmes, preliminary design and construction plans are still valid.     Access to the site of the construction project submissions, design conditions, notice of requirement and the red line charts, but not yet audited programmes, inter alia, under the figure of the indicators requirements are still valid, but rest are prescribed in the regulations.     76th article of the relevant noun meaning of the glossary in the Appendix shall prevail.       77th these provisions come into force on August 1, 2002.     Appendix: Glossary 1. transformation of the old city zone in May 1989, the urban planning regulations before the coming into force of the, as an urban land-use and construction areas.     2. the new outside area refers to the transformation of the old city area, newly zoned urban land areas. 3. slab building, also known as type building.     A building out of plane profile basic rectangle, its long side and short side ratio greater than or equal to 2 buildings, and short side length is less than or equal to 16 m.     4. point architecture refers to the architectural plan outline the basic rectangle, the long side and the short side of the ratio is less than 2 buildings. 5. the short edge of the gable style architecture. Gable Windows that can be opened on the aisle, as well as the kitchen, bathroom, storage room and other secondary rooms window.     When opened with a bedroom, living room, Office, the main room window, as the main light.     6. mainly daylighting is provided with a bedroom, lounge, Office Building exterior walls of the main room, such as Windows.     When exterior design slot tank opening with a bedroom, living room, Office, and other major room Windows, the exterior surface was also regarded as the main light. 7. housing height starting from the interior floor ± 0.00, to live and to be used until the top of the roof structure. When indoor floors is higher than the outdoor flooring 0.45 metres, calculating the height beyond the part into the housing. When the outdoor flooring range, and in lowest terms.     When the building is part of the order, order can be calculated.     8. the permanent building of the registered property construction and planning permit of construction engineering building construction has been made. 9. the annex closely connected with the high-rise buildings, low-rise buildings that make up a whole.     Podium heights greater than 24 meters, considered part of the high-rise building.     10. the low construction height is less than or equal to 10 m building, low-rise residential building to 1 to 3 floors.     11. multi-storey buildings taller than 10 meters, is less than or equal to 24 m building, multi-storey residential buildings for 4 to 8 floors.     12. the high-rise construction refers to a height greater than 24 m building, residential buildings of 9 above (with 9).     13. the apartment office building Unit space Division, an area greater than or equal to 150 square meters on average, with separate sanitation office building.     Cell-averaging less than 150 square metres in area, according to residential buildings.     14. Office building refers to non-modular space, press set for Office buildings for sanitation.     15. commercial construction to refer to the General Department store, shopping mall, operates various types of specialty retail and wholesale store, catering and other service buildings.     16. apartment (Office) refers to commercial and residential complex building (Office) mixed buildings.     17. in the main urban areas, roadway for 2-lane road and planning urban road of the width of 16 metres.     18. secondary road in the main city, refers to the roadway, for 3 or 4 lane and planned road width greater than 16 metres, less than or equal to 32 meters of urban roads.     19. the main street in the main city, referring to the roadway to 4 lanes and above and a width greater than 32 m city planning road road.     20. railway route refers to into Yu line, and Yu Guizhou line, and Grand Yu line, and Yu arms line, and Yu long-term, and was Yu line, and Yu blue line, and up million line, and four to range for North up Grand Yu line of beibei station, South to Yu Guizhou line of Luo Huang station, West reached Yu line of copper tank station, East Yu arms line of Tang Jiatuo station of Chongqing railway hub.     21. Hong Kong harbor-parking on roadways outside of the road, local formation of widening the road, and has a separation between primary and secondary roads and public transport stops.     22. dash parking on road roadway outside of Hong Kong, the local formation of widening the road, and main and secondary road between segregating public transport stop is not set.     23. the planning scope line planning range line refers to the Department of urban planning administration in accordance with the approved plan and relevant regulations, delineation of the specific construction projects planning closing line. 24. the construction construction land means planning line construction projects within the scope of use. Building area does not include road area of the city planning of roads within the red line. Building area is to calculate the approval of building volume rate, building density, ratio of green space and other technical and economic indices of basic parameters.     The calculation should be accurate to the square.     25. road planning border City Road site of the red line.     26. construction and urban roads on both sides of the red line to control Street building or structure on the frontage line, also known as the building line. 27. the main tributaries of the urban planning areas by urban planning administrative departments by reference to the relevant administrative authorities confirmed.       The downtown areas of Chongqing 12 group and North of the main rivers in the district are: River, Gai LAN XI, cuntan River, our river, Tong Jiaxi, peach Creek, River, jump kicking River, huaxi River, crabapple Creek, Zhu Xi (had become), Creek (jiuqu River), Liao Jiaxi, and Zhang Jiaxi (baiyanggou).   Table a: Note: well-built x √ not applicable 0 built by urban planning and Management Department according to the specific conditions and planning requirements.       The construction project was not included in the table, around the Department of City Planning Administration, based on environmental impacts and infrastructure conditions, specific approval. Table II: Notes: 1.       D ━━━ building density, FAR ━━━ the building volume rate.       2. outside is a planned urban area refers to the various urban planning areas outside the town.  Figure one: urban public pipe layout diagram (bilateral arrangements) (icon here see original) figure II: urban public pipe layout diagram (single sided layout) (icon here see original)