Hangzhou Elevator Safety Monitor Method

Original Language Title: 杭州市电梯安全监察办法

Subscribe to a Global-Regulation Premium Membership Today!

Key Benefits:

Subscribe Now for only USD$20 per month, or Get a Day Pass for only USD$4.99.
Hangzhou elevator safety monitor method

    (December 17, 2010, Hangzhou City people's Government, the 58th Executive meeting by Hangzhou municipal people's Government order No. 263, January 10, 2011, published since March 1, 2011) Chapter I General provisions

    First to secure the lift monitor, prevent and reduce accidents, protect people's lives and property safety, in accordance with the People's Republic of China product quality law, the regulations on safety supervision over special equipment, regulations on the safety management of special equipment, Zhejiang Province, and other laws and regulations, combined with the city's actual, these measures are formulated.

    Second elevator in the administrative area of the city in the production (including manufacture, installation, alteration, maintenance, the same below), sale, use, maintenance, inspection and testing, and related supervisory activities shall abide by these measures.

    Elevator in these measures refers to drive, box that runs along rigid guides or cascade that runs along a fixed route (time), parallel to the lifting or transporting people, goods electrical and mechanical equipment, including manned (goods) elevators, escalators, moving walkways, and so on. Article in Hangzhou City of quality and technical supervision Department is responsible for the city's elevator safety supervision work.

    Xiaoshan, Yuhang district and the County (or city) of quality and technical supervision Department responsible for the administration of safety supervision work.

    Construction, public security, industry and commerce, housing, production safety supervision and Administration Department shall perform their respective statutory duties, work safety supervision and management of the elevator.

    Article fourth of the elevator using units shall conduct safety knowledge and publicity of relevant laws and regulations, promote safe and civilized by ladder, enhance passengers safety awareness, improving the ability to protect themselves.

    Fifth Government encourages elevator production, and use energy-saving elevator technology research, development and promotion to promote elevator innovation and application of energy saving technology.

    Provide premium subsidies to encourage Government to take elevator to use units to Elevator Safety liability insurance in order to safeguard the legitimate rights and interests of passengers, reducing the security risks of elevator use.

    Chapter two elevator manufacturing and sales

    Sixth of elevator production units shall obtain the relevant administrative permission, may engage in the appropriate elevator manufacturing, installation, renovation and maintenance.

    Elevator manufacturing units to other units or individuals shall not lend, lease, transfer elevator manufacturing, installation, renovation and maintenance of qualification certificates.

    Seventh elevator manufacturing units should be used to provide the following technical services:

    (A) the necessary technical assistance;

    (B) the loss of elevator spare parts;

    (C) emergency rescue and other specialized skills training.

    Article eighth banned the sale of elevators and related products listed below:

    (A) is not accompanied by a security design specification requirements documents, product quality inspection certificates, installation and maintenance instructions of use, supervision and inspection of certificates and other documents;

    (B) use old parts and assembling;

    (C) countries has been officially eliminated and scrap;

    (D) parts with impurities, shoddy, with old new;

    (E) other laws and regulations banning the sale of elevators and related products.

    The Nineth elevator installation, alteration, major repair and construction units should be carried out prior to the construction of the proposed elevator installation, renovation and major repairs in writing inform the city of quality and technical supervision departments or their delegate construction of local quality and technical supervision Department.

    Elevator installation, reconstruction, major repairs of process shall be subject to special equipment safety supervision and management departments approved inspection bodies for supervision and inspection in accordance with the requirements of security technical specifications without the supervision and inspection of elevator shall not be used; qualified through inspection, shall issue safety inspection certificate.

    Tenth article on elevator installation, alteration, maintenance workers should obtain a unified special operations personnel format certificate, and certificate of employment records are complete. 11th elevator replacement should be from manufacturing entity or its delegate, agreed with the unit.

    Original manufacturing unit has been written off or elevator replacement units unable to obtain the consent of indigenous manufacturing units, commissioned, Elevator units should delegate has no less than the original qualification unit elevator manufacturing units transform.

    Elevator replacement unit without consent of the original manufactured units commissioned, transformation of Elevator, elevator after the renovation is complete, lift retrofit units should be carried out in accordance with the requirements of security technical specifications for lifts check and debug, replacement of the product nameplate for the elevator, and marked on the data plate, the quality of the product certificate the name, modification date, and elevator manufacturing quality information such as license number of the unit.

    Elevator replacement unit shall, after transformation of elevator quality and safe operation responsible for quality problems involved.

    12th construction should lift the safety management of the construction project shall perform the following duties:

    (A) the delegate unit designed for use with the appropriate qualification structure of the elevator, Elevator hoistway, pit, machine room, rail brackets embedded design shall comply with the installation, use the special requirements to avoid safety hazard;

    (B) ensure the selection and installation of elevators, and standby power supply requirements and architectural structure, adapted to requirements;

    (C) building 15th construction provided these measures shall be chosen by the made in the tender documents for construction elevator configuration technical conditions for safe operation of elevator monitoring system;

    (D) the employer and use inconsistent, the construction unit to unit transfer elevator shall comply with the requirements of security technical specifications, and at the transfer of complete set of security technology archives, warning signs and safety inspection certificate.

    Chapter elevator 13th lift of ownership units using artificial lift.

    Other units elevator elevator owners delegate, entrusted with the units within the scope agreed upon by both parties assume the role of elevator users.

    14th elevator in or put into use in the 30th before going live, use the unit should be registered with the city of quality and technical supervision departments.

    Scrap, stop using elevators or dismantle, transfer elevator, Elevator units should be in the city of quality and technical supervision Department within the prescribed time limit for the corresponding stop, log off, change procedures.

    15th article in whole or in part using Government funds for construction projects and the following new public elevator, you should configure the elevator safety monitor and control system with image acquisition capabilities, and with the elevator day-to-day maintenance elevator safety operation monitoring center network:

    (A) schools, kindergartens, child care centres;

    (B) medical institutions;

    (C) squares, parks, bridges, footbridges, pedestrian tunnels, airports, railway stations, ferry terminals, bus (electric) station (station), rail transport, public car park;

    (Iv) store (field), supermarkets, hotels, trading markets, dining, entertainment;

    (E) Stadium (Museum), galleries, theaters, concert halls, museums, archives, libraries (House), an art gallery, Museum and other places of art, culture, science and education;

    (F) municipal provision of other public places.

    New residential elevator and the addition of elevators in existing residential buildings, you should configure the operation parameter acquisition of elevator safety operation monitoring system, and with the elevator day-to-day maintenance elevator safety operation monitoring center network encourages new residential elevator and elevator use of existing housing units run the image capture device.

    16th elevator unit meets the requirements of security technical specifications should be used lift, to the unit responsible for the safe operation of the lift, and perform the following security management responsibilities:

    (A) set the elevator safety authorities or full-time safety Manager;

    (B) establish and strictly enforce the safety operation management system, establish a complete elevator safety technology files;

    (C) ensure the elevator can effectively answer the SOS emergency alarm devices;

    (D) in the elevator or entrances and posted in a clear position to use safety precautions, warning signs and safety inspection certificate;

    (E) development of elevator faults emergency response measures and rescue plans, and regular drills;

    (Vi) found that elevator accidents, suspension lift, and to report to the local quality and technical supervision Department;

    (G) the passengers being trapped failure to take prompt measures to comfort and rescue trapped passengers.

    17th elevator unit shall entrust an administrative license according to law of elevator installation, alteration, maintenance, or elevator manufacturing units for routine maintenance, and sign a maintenance contract.

    18th regular safety inspection in the elevator cycle for one year.

    Elevator use of units shall, on the expiry of the elevator safety inspection in the 30th before applying to the elevator inspection bodies periodic inspection.

    Elevator safety inspection by qualified elevator maintenance unit of change within the validity period, use the unit should be within 15th of the maintenance contract, daily maintenance contract to perform periodic inspection of inspection agencies to replace the safety inspection certificate. Article 19th of the elevator unit shall assign full-time safety Manager or specialist storage, use the elevator keys.

    Elevator key storage, users, and shall obtain the corresponding special operations personnel qualification.

    Drivers to lift, the hospital provides patients with private elevator and directly employed in tourism and passenger lift speeds greater than 2.5 m/s, should be made by the appropriate special operations personnel qualification for elevator driver. 20th no units in the elevator the elevator for excessive decoration.

    Exceed the rated load 8% changes in the weight of the elevator car, belonging to major maintenance, Elevator maintenance permit qualification shall entrust made unit.

    21st passenger elevator shall comply with the lift requirements for using security considerations, obey the command staff concerned, civilization by ladder, protecting its own security, without prejudice to others.

    22nd an elevator in any of the following circumstances, elevator use can apply to inspection bodies for technology assessment, as a basis for an elevator renovation, major repairs:

    (A) over 15 years of age;

    (B) the failure rate is high, affecting the normal use;

    (C) the excessive energy consumption.

    Lift the 15th article in these measures, their use for more than 15 years, using units shall apply to the inspection and testing technical assessment, and a technology assessment every five years.

    The fourth chapter elevator day-to-day maintenance

    23rd elevator day-to-day maintenance unit prior to the day-to-day maintenance elevator, the elevator should be required for the security, reliability, and maintenance personnel, technology, equipment and spare parts supply for confirmation, ensure that elevator day-to-day maintenance maintenance contract have the ability to support the safe operation of the lift.

    Elevator day-to-day maintenance unit maintenance the provisions of article 15th elevator, Elevator Safety Monitor centers should be established, and emergency handling Center networking and special equipment.

    24th elevator day-to-day maintenance units should be based on the maintenance of the technical condition of the lift, put the following contents into daily maintenance contracts:

    (A) the daily maintenance of the nature, contents, implementation of construction standards and requirements;

    (B) routine maintenance dates and frequency of elevator day-to-day maintenance;

    (C) assist units in preparing emergency response responsibilities;

    (D) the malfunction and emergency rescue response time.

    25th elevator day-to-day maintenance units should be in accordance with the safety specifications and lift installation and maintenance instructions, develop and perform routine maintenance schedule.

    Elevator day-to-day maintenance unit found in the day-to-day maintenance elevator did not meet safety specifications and is a security risk, it shall inform in writing the use of units; there are major security risks, which should include written reports to local quality and technical supervision departments. Elevator day-to-day maintenance units shall establish routine maintenance records for each lift.

    Routine maintenance records should be kept for at least four years. 26th elevator day-to-day maintenance units should be at least every six months, in accordance with the instructions on maintenance of elevators conducted its own tests, and make a written record.

    Self testing shall be carried out by the unit of elevator inspectors.

    27th elevator day-to-day maintenance units shall establish a 24-hour duty system, established duty calls, and maintenance of elevator car prominently identified within the organization name and emergency rescue calls.

    Except for force majeure, Elevator day-to-day maintenance units after receiving fault reports of passengers trapped elevator is located in the downtown area, should be carried out within 30 minutes to arrive at the scene and rescue in other areas, should be carried out in less than an hour to arrive at the scene and rescued.

    Elevator day-to-day maintenance while rescue units, trapped faults should be reported to the local quality and technical supervision Department.

    Article 28th of the elevator day-to-day maintenance elevator failures should be established emergency measures and rescue plans, for the maintenance of different types of elevators, conducted emergency drills at least once a year and made written records.

    29th article outside this city elevator day-to-day maintenance of industrial and commercial registration unit within the administrative area of the city on elevator day-to-day maintenance operations shall be submitted to the city's quality and technical supervision Department filing procedures, and the specific measures formulated by the city of quality and technical supervision departments. 30th of quality and technical supervision Department annual assessment against elevator day-to-day maintenance units.

    To fail to pass the annual examination unit, should be reprimanded and ordered rectification; on the rectification of substandard units, can suggest authority revoked the corresponding qualification.

    Fifth chapter elevator inspection

    31st elevator inspection bodies shall perform the following duties:

    (A) ensure that its inspection staff have the qualifications prescribed by the State;

    (B) the inspection activities in accordance with regulations stipulated by the State;

    (C) use the unit to facilitate inspection and testing services for elevators, obligations relating to the confidentiality of trade secrets.

    32nd elevator inspection bodies periodic inspection of the elevator shall, upon receiving the unit within ten working days from the date of the application for inspection is complete and issue an inspection report and inspection by qualified elevator shall be issued in conjunction with safety inspection certificate. 33rd elevator unit for periodic inspection of the elevator disagrees with the results, from the date of receipt of elevator inspection report in writing to the elevator inspection agencies within the 15th contested.

    Elevator inspection agencies to lift and use written objection shall be received within 15th of the written replies to the elevator use. Elevator inspection overdue replies, or elevator elevator inspection agencies using the unit still has objections of the written replies, elevator use to date of elevator inspection agencies late reply, or elevator inspection agencies received a written reply within 15th of local quality and technical supervision Department to file an application for re-inspection.

    Accepts an application for re-inspection of quality and technology supervision departments shall be from the date of receiving the application for reinspection reinspection conclusions on the 30th.

    34th elevator inspection agencies in implementation of elevator inspection found safety hazards or accidents, shall notify the elevator use and daily maintenance unit to take timely action.

    Elevator inspection agencies to find elevator accident, shall notify in advance the elevator suspension lift, and reports to lift local quality and technical supervision departments. Article 35th of the elevator inspection agencies received a lift and use in accordance with this article 22nd following a skills assessment application made, the expert review team shall be composed of not less than three persons, in accordance with the relevant national standards to assess the use of elevators.

    After the assessments issued by the expert review teams, and elevator inspection agencies should review and receipt of the elevator using skills assessment application issued within three months from the date of the technical evaluation report of the results.

    By technology assessment finds take security or technology measures can makes elevator reached security run requirements of, Elevator test detection institutions should issued can continues to using of assessment results; by technology assessment finds take security or technology measures still cannot makes elevator reached security run requirements, or continues to using cost high, and not meet energy efficiency index requirements of, should issued suspended using, and stop using or be scrap of assessment results.

    The sixth chapter, supervision and inspection

    36th quality technical supervision departments should be on the way to 15th article building projects and public use of the elevator, as well as an important meeting or a major social activity site elevator used to implement key security monitoring.

    37th of quality and technical supervision departments should establish safety complaints reporting system, telephone, mail or e-mail addresses published, accepted to lift production, sales, use, maintenance, inspection, violations and complaints of elevator accident, and be dealt with in a timely manner.

    Article 38th of quality and technical supervision departments to elevator safety authorities, found the elevator unsafe shall be made to the elevator use and daily maintenance for unit safety instructions, ordered corrective action and eliminate security risks.

    39th quality technology supervision Department received the elevator inspection agencies in accordance with the article 34th after the second paragraph of the report, shall arrive at the scene within two hours, in conjunction with the elevator inspection agencies for processing, and to stop using the instruction as appropriate, cancel, suspend the use instructions or need further technical assessment decisions.

    40th of quality and technology supervision departments receive a lift after reports of the accident shall immediately proceeded to organize, verify accident situations, in accordance with the provisions of the regulations on safety supervision over special equipment immediately reported to the people's Governments at the corresponding level, and superior quality and technology supervision departments step by step report and, if necessary, you can also skip reporting accidents. 41st city of quality and technical supervision departments should regularly publicize safety and energy efficiency.

    Elevator Safety and energy efficiency should be announced include the following:

    (A) quality and safety of elevators;

    (B) the elevator failures and accidents, analysis of characteristics, causes, and countermeasures;

    (C) lift status of energy efficiency;

    (D) published details of other needs.

    The seventh chapter legal liability

    42nd for acts in violation of these rules, People's Republic of China product quality law, the regulations on safety supervision over special equipment, regulations on the safety management of special equipment, Zhejiang Province, and other laws and regulations on penalties, in accordance with its provisions for punishment.

    43rd article violates this article eighth paragraph (b) provides that sales of used parts and assembling of elevators and related products, the local quality and technical supervision authorities shall order to stop the illegal sales, with more than 20000 to 50000 Yuan fine.

    44th elevator use in violation of this article approaches the 11th article, units retrofit elevator of a delegate does not have the appropriate qualifications, shall be ordered to immediately stop rebuilding by the quality and technology supervision departments, and elevator units and rehabilitation unit fined 2000 Yuan more than 20000 RMB fine.

    Elevator transformation units violation this approach 11th article second paragraph provides, in elevator transformation completed Hou not according to security technology specification of requirements on elevator for check and debugging, not replaced products nameplate, or not in products nameplate, and quality certificate Shang marked this units name, and transformation date, and this units elevator manufacturing qualification license pieces number, information of, by quality technology supervision sector ordered deadline corrected, late not corrected of, sentenced 2000 Yuan above 10000 Yuan following fine.

    Article 45th in violation of this article 12th paragraph (d) provides that no transfer of complete set of security technology to use files, warning labels or safety inspection certificate, by the quality and technology supervision departments a rectification, it fails to mend, fined a maximum of 2000 more than 10000 Yuan.

    Article 46th elevator use in violation of this article 14th paragraph, cessation of use, transfer elevator was not within the prescribed time for stop, change and rectification by the quality and technology supervision departments, it fails to mend, fined a maximum of 2000 more than 5000 Yuan. 47th article violation this approach 15th article first paragraph provides, all or part using financial sex funds of construction project and new of public using of elevator not configuration has image collection function of elevator security run monitoring system of; violation this approach 15th article second paragraph provides, new residential using of elevator and both residential additional of elevator not configuration has run parameter collection function of elevator security run monitoring system of, by quality technology supervision sector ordered units deadline configuration, sentenced warning,

    And be criticized.

    48th elevator use in violation of this article 16th (b), (c), (d), (e) provides that failure to perform appropriate security management responsibilities, rectification by the quality and technology supervision departments, it fails to mend and fined 2000 Yuan more than 20000 RMB fine.

    49th elevator use in violation of the third paragraph of article 18th, not within the time stipulated in the replacement of safety inspection certificate, rectification by the quality and technology supervision departments, it fails to mend, fined a maximum of 2000 more than 5000 Yuan.

    Elevator day-to-day maintenance units of the 50th article violates these measures article 23rd, 25th article, third paragraph, or in violation of these regulations the 26th, 27th, 28th, 29th article, by the quality and technology supervision departments shall be ordered to correct, and a fine of 2000 more than 1000 Yuan fine.

    Elevator day-to-day maintenance of the 51st article violates article 24th of this approach provides that provisions are not included in the daily maintenance contracts, rectification by the quality and technology supervision departments, and a fine of 2000 more than 5000 Yuan fine.

    52nd elevator inspection agencies to disobey the 32nd article, in accordance with the required deadline issued by the inspection report or safety inspection certificate issued by the, by the quality and technology supervision departments a rectification, it fails to mend, fined a maximum of 2000 more than 10000 Yuan.

    53rd elevator inspection agencies to disobey the 34th article found the elevator for security breaches or accidents that did not inform the elevator use and daily maintenance unit, or finds an elevator accident report failed to lift the local quality and technical supervision departments and rectification by the quality and technology supervision departments, and fined a maximum of 2000 more than 5000 Yuan.

    54th of quality and technical supervision Department staff in elevator safety supervision of dereliction of duty, abuse of power, favoritism, monitored by their units, the competent departments or agencies shall be given administrative sanctions.

    The eighth chapter supplementary articles

    55th household installation of elevators used in safety supervision and management and inspection, these procedures do not apply. 56th article of the rules take effect on March 1, 2011.

Related Laws