    First to further strengthening the management of urban and rural planning, improve the planning, management, legal, scientific and standardized management of urban and rural planning, guarantee the implementation of urban and rural planning, according to the People's Republic of China town and country planning Act and other laws and regulations and the overall planning of Guiyang City and related technical specifications, combined with the city's actual, these measures are formulated.

    Second partition within the urban planning area planning, regulatory detailed planning and detailed construction plans, preparation of the professional planning, landscape planning, urban design, architectural layout and design, and a variety of technical management of construction project planning, should comply with these measures.

    Qingzhen city, kaiyang County, Xifeng xiuwen, and references to these measures.

    Urban construction planning management criterion separately.

    Article in city planning area of the city in urban planning and implementation planning and management should be used independent coordinate system in 1956 and huanghai sea system in Guiyang City.

    Fourth technical management urban planning should be guided by the following principles:

    (A) the ecological first, people-oriented, urban and rural areas and promoting comprehensive, coordinated and sustainable development of economic, social and ecological environment;

    (B) according to local conditions, reasonable layout, to respect and comply with the nature, construction of "integration of landscape city" urban characteristics;

    (C) rational land use, intensive development, improvement of the ecological environment, and promote energy conservation and comprehensive utilization of resources;

    (D) construction of the integrated urban infrastructure and service functions, promoting coordinated regional development.

    Chapter II municipal landscape control

    Fifth city planning, construction and management, focus on the main axis of the landscape and the main node, the iconic building, main entrance of the rural-urban fringe, urban planning and design, highlight the squares, green spaces, rivers and other public open spaces of functions and features, and urban design on the following areas:

    (A) both sides of the main roads of the city, River, railway station, airport, city square around as well as passenger transport hub, main entrances of the city and other important nodes;

    (B) cultural relics protection units, historical and cultural blocks, protection of ancient and famous trees range, major tourist spots;

    (C) cross-region location node;

    (D) other areas of the city people's Government.

    Sixth article color should be combined with the city's urban construction project orientation, cultural and geographical and cultural characteristics, lightness, saturation of the color, harmony with the surrounding environment should be fully considered, in accordance with the relevant provisions of the Guiyang City color planning; lighting shall conform to the Center in Guiyang City nightscape lighting relevant provisions of the plan.

    Construction projects shall make full use of modern environmental technology, using good decorative effect, low carbon, in line with standard materials.

    Article construction, reconstruction of buildings and structures shall conform to the height limits on buildings in the planning conditions require.

    Layouts by groups of tall buildings, should be combined with the terrain and surrounding environment, form a variety of city skylines, has significant impacts on urban skylines, its height and volume should be subject to special demonstration.

    Eighth along the city's main roads on both sides of the building, should focus on building the integrity and continuity of the interface.

    Along the river banks on both sides of the construction, the permeability of the ecological landscape corridors should be maintained.

    City Park, and wetlands surrounding the theme park construction, shall conform to the design requirements, should not affect the Park.

    Chapter of urban construction land Nineth urban construction land according to the urban land classification and land planning and construction standards (GB50137-2011) for classification.

    Well-built range of construction land according to the approved detailed plans of implementation.

    Tenth planning and design criteria should include the following:

    (A) the planning of land use and the compatibility of land use control requirements;

    (B) planning area include: clear and total area, land area, municipal roads and other not included in the calculation of the area;

    (C) the floor area ratio;

    (D) the building density;

    (E) Building Height Restriction;

    (F) ratio of green space;

    (G) parking space;

    (VIII) municipal facilities requirements;

    (IX) public services and public safety facilities required;

    (J) the urban design requirements;

    (11) meets other cities such as sunshine, fire-building requirements.

    11th controlled detailed planning is not clear building blocks of building floor area ratio in accordance with the following provisions:

    (A) non-residential land shall not have living functions;

    (B) residential land use compatibility with other properties, the residential floor area shall not be greater than above ground area of 80%;

    (C) compatible residential land for public facilities, public facilities construction area shall not be less than the above ground area of 50%.

    12th article construction with to area is less than 5000 square meters of live with to and live with to compatible other with to, or is less than 3000 square meters of non-live with to, or with to shape not rules, and and City Road not connected, reasons and not has separate construction conditions of with to shall not separate construction, should according to conducive to city planning overall implementation of principles, and around with to integration using.

    Sporadic land which cannot be integrated, encourages urban green spaces, public spaces and public construction projects, banned for commercial projects.

    The fourth chapter building capacity control 13th in city planning area, renovation for building volume rate, building density indicators shall be determined in accordance with approved regulatory detailed planning.

    Preparation of controlled detailed planning, plot ratio and building density in accordance with the building density and volume control indicator form (hereinafter "Annex") shall apply.

    14th schedule a is not explicitly control indicator in the Executive Office, education and culture, health, sports, scientific research institutions, industrial plants, storage, military facilities, and residential public services, community support facilities, such as the building density and volume rate indicator, in accordance with the relevant provisions.

    15th floor space calculations according to the standard measurement for construction area (GB/T50353-2005) of the Executive, the State does not require calculations in accordance with the provisions of rule execution. 16th section land has different building, classification should be designated building land, building density and floor area ratio calculated respectively. Commercial offices or commercial and residential building, the building density in accordance with the schedule of implementation of indicators for public buildings.

    Commercial floor space or Office floor space of the building area of 10% is not, or only for commercial or Office at the bottom of comprehensive residential, volume of housing indicators in the implementation schedule.

    17th building adjacent to an urban road construction, road elevation elevation ± 0.00 to the city starting; buildings adjacent to two or more of city road construction, by the Department of town and country planning based on urban roads and urban landscape needs, determine the starting point of elevation ± 0.00.

    Using terrain elevation difference of construction projects, fire engines can be reached directly into the roof and the building entrance, the semi-underground part is parking not included in building density, but the construction project area shall not be greater than the construction of a building with an area of 60%. 18th use of underground space should be in line with the overall planning, principles of moderate development, giving priority to meet public safety needs, and dovetailed with the surrounding the underground construction of the project. Civil air defense projects, and emergency facilities in accordance with the relevant provisions.

    Construction, reconstruction of buildings and structures shall be in accordance with the relevant provisions set aside for underground public utilities development.

    The fifth chapter architectural space

    Article 19th building space must comply with the sunshine, fire, health and safety, engineering, architectural specifications and relevant provisions of laws and regulations on cultural relics protection.

    20th sunshine standards for construction projects shall be executed in accordance with the following provisions:

    (A) Sun shine requirement for housing, hospitals, schools, nurseries, kindergartens, retirement homes, dormitories and other construction projects, sunlight analysis should be carried out and to meet the country's Sunshine standards specifications.

    (B) construction projects around Sun shine requirement for buildings or unfinished buildings, sunlight analysis should be carried out, and to meet the requirements of the following specifications:

    1. code for design of residential building (GB50096-1999);

    2. the planning and design of urban residential area code (GB50180-2002);

    3. the General principles of the civil architecture design (GB_50352-2005);

    4. other relevant provisions.

    Fundamental analysis parameters: analysis by sunshine technology parameter table of.

    21st nursery and kindergarten classrooms, living rooms should reach the winter solstice sunlight standard full window is not less than 3 hours of sunshine, site should meet the one-second of the activities area of its activities outside the scope of the standard building Sun shadow line requirements, standard classrooms in primary schools should reach the winter solstice full window sunlight standard of not less than 2 hours of sunshine. 22nd construction project of the transformation of the old city district of constructional detailed planning and monomer solutions, new sunshine standards may reduce, as appropriate, but should not be lower than the standard big chill days 1 hours of sunshine.

    Construction scale of the transformation of the old city area to develop a total construction area of 150,000 square metre construction project, sunlight analysis does not meet the type 5% of the total number of households should be controlled in the following.

    23rd senior and high-rise residential buildings in the following spacing in addition meet the requirements of national standard of sunshine standards, should also meet the following requirements:

    (A) residential sunshine distance: North-South parallel arrangement of houses, building height and building positive spacing ratio of 1:1.1, the minimum distance shall be not less than 13 m.

    (B) housing front space reduction shall, in accordance with standards established by sunshine sunshine distance coefficients of different direction control, or in accordance with the provisions of the different azimuth spacing reduction coefficient table conversion.

    (Three) gable and gable of spacing shall not is less than 7 meters; mutual vertical layout of residential, Gable face longitudinal wall surface, Gable surface depth should control in 12 meters following, minimum spacing shall not is less than 10 meters; except breathable high window, Gable surface shall not open window, and shall not pick balcony, Pro gable Bay shall not double side set balcony; depth is greater than is equal to 12 meters of gable or gable open window of, should according to open window surface sunshine spacing concession.

    (D) not parallel nor perpendicular arrangement of housing in accordance with the following provisions:

    1. two residential window facing the open window of the angle is less than or equal to 15 °, in accordance with the window open the window of space requirements, the narrowest spacing shall not be less than 1:1, the minimum distance shall be not less than 13 m;

    2. two residential window open the window surface greater than 15 ° less than the angle of 45 °, the narrowest spacing shall be not less than 13 m;

    3. two residential Windows faced with Windows that open face angle equal to or greater than 45 ° is less than 60 °, the narrowest spacing shall be not less than 13 m;

    4. two residential Windows faced with Windows that open face angle equal to or greater than 60 ° is less than 90 °, in accordance with the gable facing the open window spacing control, shall be not less than 10 metres at its narrowest spacing.

    (E) residential layout South, East or South East, South West slopes high up to 30 ° when using terrain elevation difference of specific size, space reduction, after the reduction of space shall be not less than 13 m; North to within 30 ° slope, depending on the specific size of topographic height difference, in equal proportion to increase spacing.

    24th senior and less senior level residential, Gable Windows that allows you to set a high permeability, window size cannot be greater than 0.6 x0.6 m, high Windows from the floor under the ground shall not be less than 1.6 meters.

    25th article top and the ratio of the spacing between the high-rise apartments in 1:1; middle-level and senior apartments and neighboring residential space, in accordance with the provisions of article 23rd.

    26th in high-rise buildings and high-rise, high-rise, space in a multi-storey and low-rise residential buildings should meet the following requirements:

    (A) in high-rise buildings arranged in parallel with high-rise and high-rise residential buildings in the following space:

    1. North-South layout, building frontage is less than 40 m tall building and North of the space shall be not less than 30 metres of residential buildings, building width greater than or equal to 40 m tall buildings and residential buildings North of space shall be not less than 40 m;

    2. North-South layout, building frontage is less than 40 m high-rise building and space shall be not less than 24 metres of residential buildings on the South side, building width greater than or equal to 40 meters of high-rise building and space shall be not less than 30 metres of residential buildings on the South side;

    3. the layout, building frontage is less than 40 m tall building and West side space in residential building shall be not less than 24 metres, building width greater than or equal to 40 meters of high-rise building and space shall be not less than 30 metres of residential buildings on both sides.

    (B) the tall building with vertical arrangement of high rise and high-rise residential buildings in the following space:

    1. North-South layout, North side of the gable side of high-rise building and its space in residential building shall be not less than 24 meters, Gables residential buildings on the South side of high-rise building space shall be not less than 20 metres;

    2. things to decorate, Gables residential buildings in East and west sides of high-rise building space shall be not less than 20 metres;

    3. the high-rise construction gable width greater than 15 meters or Windows that open (except breathable high window), spacing according to the parallel arrangement of building control.

    (C) the tall buildings and high-and high-rise residential buildings is not parallel nor perpendicular layout the spacing:

    1. when the two buildings at the angle of 45 degrees or less, the minimum spacing according to the parallel arrangement of control;

    2. when the angle between the two buildings is greater than 45 degrees to 90 degrees or less, the minimum spacing according to the vertical layout control.

    (D) top gable of the building and high-distance between walls of high-rise residential building shall be not less than 13 m.

    27th 24 meters above the common architecture and architectural space between 24 meters of public buildings, shall comply with the following provisions:

    (A) 24 m above public buildings arranged in parallel spacing between:

    1. North-South layout, building frontage is less than 40 m of public buildings and public buildings in South and North sides of space shall be not less than 24 meters, building width greater than or equal to 40 meters of public buildings and public buildings in South and North sides of space shall be not less than 30 m;

    2. the layout, building frontage is less than 40 m public architecture and public space shall be not less than 20 metres on both sides, building width greater than or equal to 40 meters of public buildings and public buildings shall be provided on both sides of less than 24 metres.

    (B) 24 m above public buildings with 24 meters of public buildings arranged in parallel spaced minimum of 20 meters.

    (C) 24 m the following public buildings arranged in parallel spacing between a minimum value of 13 meters.

    The spacing of the layout in other forms of public buildings, in accordance with the provisions of fire prevention space control.

    28th 150-metre high-rise building with 150 meters of space in residential buildings, shall comply with the following provisions:

    (A) 150 m high-rise building with 150 meters of residential buildings arranged in parallel spacing:

    1. North-South layout, high-rise buildings and residential buildings in the North space shall be not less than 40 m;

    2. North-South layout, high-rise buildings and space shall be not less than 33 metres of residential buildings on the South side;

    3. things to decorate, high-rise buildings and space shall be not less than 30 metres of residential buildings on both sides.

    (B) 150 m high-rise building with 150 meters of residential buildings in the following vertical spacing:

    1. North-South layout, Gable surface North of the super high-rise building space of not less than 30 m of residential buildings, high-rise building Gables residential buildings on the South side is no less than 24 metres;

    2. things to decorate, Gable surface residential building in East and west sides in extra tall building space of not less than 24 metres;

    3. super high-rise building gable width greater than 15 meters or Windows that open (except breathable high window), spacing according to the parallel arrangement of building control.

    (C) 150 m high-rise building with 150 meters of residential buildings are not parallel nor perpendicular arrangement of space:

    1. when the two buildings at the angle of 45 degrees or less, the minimum spacing according to the parallel arrangement of control;

    2. when the angle between the two buildings is greater than 45 degrees to 90 degrees or less, the minimum spacing according to the vertical layout control.

    (D) 150 m high-rise building Gables with 150 meters distance between walls of residential building shall be not less than 20 metres.

    29th Street 150 m super high-rise building with 150 meters below the space of public buildings, shall comply with the following provisions:

    (A) 150 m super high-rise building with 150 meters of high-rise, high-rise public buildings arranged in parallel spacing:

    1. North-South layout, super high-rise public building and the South and North sides of high-rise, high-rise public buildings spaced not less than 33 metres;

    2. things to decorate, super high-rise public building west side high-rise, high-rise public building space shall be not less than 30 m;

    (B) the super high-rise public building and the multi-storey and low-rise public buildings arranged in parallel spaced minimum of 24 meters.

    30th Street 150 m and 150 m high-rise building space, by the competent authorities according to the circumstances of urban and rural planning.

    31st floor of irregular, with the elevation profile width of width instead of extension cords to form and calculate the width for architectural space, in accordance with this Regulation determines the minimum spacing, respectively.

    Article 32nd main lighting of the building and to partly repeal a building does not have Windows or two buildings lighting up at the Windows part are determined according to the main lighting relative spacing.

    Article 33rd two does not have Windows for residential buildings part of splicing, splice shall be not less than 3 metres in length.

    Calculation of height of 18 meters, and along city roads, squares or parks layout of residential buildings, need to splice, splicing after the building width should not exceed 80 meters.

    Residential building in height of 18 m to 50 m, between a height of 18 m to 50 m live construction and calculation of height of 18 m between the residential buildings, need to splice, splicing after the building width should not exceed 70 metres.

    Calculate the height of 50 meters or more residential buildings and other residential building shall not be spliced in principle, absolutely necessary to splice, splicing after the building width should not exceed 70 metres, and not along the primary and secondary roads, squares or parks, urban layout.

    Building height is greater than or equal to 100 meters is less than 150 m super high-rise residential buildings in principle shall not be spliced, absolutely necessary to splice must be experts.

    Article 34th retaining walls, slope, Fort Sill and the minimum spacing of the building shall implement the following:

    (A) under the influence of geological hazard-free, should meet the sunshine, ventilation and protection in residential buildings, fire protection needs;

    (B) the height greater than 2 m less than 6 metres of retaining wall and upper edge of the slope and building the net distance shall be not less than 5 metres, lower margins and building the net distance shall be not less than 3 metres;

    (C) the height greater than or equal to 6 metres of retaining walls should be back, back width of not less than 1.5 m; (D) building and the Fort sill height greater than 1 m when, building exterior border Fort and Fort Sill bottom distance shall not be less than 0.4 times times the height of the threshold, and shall not be less than 3 meters.

    Fort Sill back to Taiwan, can be divided into first-order calculation.

    35th light tank of the super high-rise residential and high-rise residential, aspect ratio of not less than 1:2.5, Groove width min shall not be less than 2.7 m; and the multistory light tank, aspect ratio of not less than 1:2, Groove width min shall not be less than 2.4 metres; senior and less senior level residential patio plane axis dimensions shall not be less than 3.3 X3.3 m.

    The sixth chapter building concessions from

    36th buildings along city roads and highways, railways, urban rail, River, trunk sewer, civil air defense facilities, heritage, power reserves and other land border construction, shall comply with the relevant laws, regulations, norms and the distance the concessions as provided herein. 37th used to build buildings, ways should be in accordance with the standards prescribed by the fifth chapter building space of one-second and in accordance with the adjacent buildings or space requires concessions that have been granted construction.

    When building Windows that open borders layout, shall meet the spacing requirements and adjacent buildings give way, minimum yield a distance of 6.5 meters, the gable surface using boundary does not open the window layout, shall meet the spacing requirements and adjacent buildings give way, minimum yield a distance of 5 meters.

    38th buildings used to build not only meet this way outside the 37th article, around the building as sun shine requirement for buildings or buildings that are not built, architectural sunlight analysis should be carried out with sunshine requirements and meet the requirements of national standard of sunshine standards.

    39th along city road construction, reconstruction of buildings, Setback distance in accordance with the road building concessions on City Road red control indicator form (hereinafter "Schedule IV") shall apply.

    40th along the red line width is less than 20 meters of the planned road, on both sides of the building in accordance with the code for planning design of urban residential area (GB50180-2002) of the concession, and should ensure that spacing requirement and the adjacent buildings. 41st along the range of existing or planned overpass construction, reconstruction of buildings, buildings and construction projecting part back along the road side of the actual projection of the City line Road overpass range red line distance shall not be less than 30 m.

    Overpass in accordance with overpasses and deceleration lane on ramp departure points, including ramp outermost projection line.

    42nd along existing range or planning on both sides of the viaduct construction, reconstruction of buildings, environmental protection and sunlight requirements should be met, buildings and construction projecting parts along the road side are actually the projection line back areas of the viaduct from the red line, in accordance with the provisions of Schedule IV.

    43rd intersection design of urban road intersections in accordance with standard designs, ranging from road planning of urban road intersections red line computed from the connection point for a curved segment, calculated according to the road grade, imported lane line segment of length 50 m to 80 m, exit lane line from 30 m to 60 m in length.

    44th new large-scale theaters, shopping malls, amusement parks, sports stadiums, exhibition halls and other public buildings, main entrance and exit directions back to the municipal road less than 15 meters distance from the red line, and parking, (Editor's Note: the word "back", as words, along with the structure of) cars, flow distribution needs. 45th on the pipeline interfaces in addition to cities outside, sewage pipes, walls of buildings, structures, time, balcony, canopy not into programming way.

    Water wells, septic tanks and ancillary facilities of underground urban way back not less than 5 m.

    Article 46th both sides of the road or highway construction concessions shall comply with the following requirements:

    (A) Highway, 30 meters on each side;

    (B) road, 20 meters on each side;

    (C) a secondary Highway, 15 meters on each side;

    (D) category IV road, 10 metres on each side.

    Outside the urban planning area of town, village near both sides of the road or highway construction concessions, reference to the provisions of the preceding paragraph.

    Highway planning and isolation within the red line construction, reconstruction of buildings, afforestation, approved by the law, digging ditches, laying pipelines, erecting pole lines, open the service lane. 47th along the mainline road and drainage construction of buildings or structures, shall, according to the Bank of the blue line and drain line outside the scope of protection of 2 metres back down.

    Rivers, drainage line protection, control standards shall be in accordance with the following plan:

    (A) on both sides of the nanming river protection control standards:

    1. the huaxi reservoir to the longwangmiao section of the dam, River 50 metres on either side of the blue line control;

    2. the Dragon King temple to Shui Hau Temple bridge, River 20 meters on either side of the blue line control;

    3. nozzle to Wudang Temple bridge bridge, 60 metres on either side of the centre line of control.

    (B) River, the River through the city, the car he, Chen Lianghe, MA di River and other rivers, river banks 7 metres on either side of the blue line control.

    (C) yuliang, banks control 50 meters on each side of the blue line.

    (D) the small river, river banks control 50 meters on each side of the blue line.

    (E) the trunk sewer in order to control lateral section of not less than 3 metres.

    (Vi) other main protection of rivers, drainage, urban and Rural Planning Department determined in accordance with factors such as flood control and urban landscape.

    48th railway construction, reconstruction of buildings on both sides concede, the distance shall be in conformity with the following provisions: (A) except directly for railway service facilities yiwai, in city planning district range within high-speed rail sides construction of, away from side unit track center line not is less than 40 meters, in Center City yiwai high-speed rail sides construction of, away from side unit track center line not is less than 50 meters; in railway route sides construction of, away from side unit track center line of distance not is less than 20 meters; in railway extension, and lines sides construction of, away from side unit track center line of distance not is less than 15 meters; in railway sides built wall of,

    Stocks track one-second is less than the distance from the centerline of the above, the height of the wall not more than 2.5 metres;

    (B) the railway line when the tread on the ground, building concessions distance calculated according to the slope edge under;

    (C) along the railway to build high-rise buildings and towers, chimneys, tall buildings, dangerous goods stores and yard compromise distance, by the Department of town and country planning determined by the railways Department.

    49th civil air defense facilities, construction of buildings and structures in the vicinity, its compromise distance in accordance with the measures for the construction and management of civil air defense works in Guiyang City and related provisions.

    50th in cultural relics protection units, cultural relics protection and construction control of heritage conservation zone under construction, should be consistent with cultural relics protection laws and regulations and other related regulations.

    51st on the airport, communications, microwave and other related infrastructure to the level of avoidance distance in accordance with the relevant technical standards.

    The seventh chapter building height control

    The 52nd building height shall comply with the controlled detailed planning, and should be subject to urban landscape planning, urban design, urban planning needs to control the height of the node, and meets sunlight, space, fire protection and other aspects of regulation.

    53rd House of one of the following circumstances, you should set up elevators:

    (A) seven-layer and above residential or household entrance floor from ground level outdoor design exceeds 16 m;

    (B) the underlying business, overhead storage space multi-storey residential or other property whose entrance floor surface from the exterior design of the building height of over 16 meters.

    Residential, one of the following circumstances, in accordance with the following provisions:

    (A) the thermocline where the top two levels of a dwelling, the duplex part regardless of the layer, its top tenants floor from the entrance of the exterior design of the building height of not more than 16 meters, no lift;

    (B) residential middle-tier there is through outside entrances and ground fire channel, the layer can be calculated from the middle tier, top tenant floor from the entrance of the building exterior design ground height of not more than 16 meters, no lift, but no more than nine.

    54th at the airports, weather, radio, telecommunications, microwave communications, satellite earth stations, military installations and other clearance requirement areas, renovation of buildings and structures, and its height shall comply with the relevant provisions.

    55th on heritage protection and construction control areas outside the core area and scenic construction, reconstruction of buildings, its height should be consistent with cultural relics protection laws and regulations, and the scenic spot, Guizhou province requirements and other relevant provisions of the Ordinance.

    The eighth chapter of municipal public facilities

    First public facilities

    56th sanitation facilities shall be in accordance with the following index settings:

    (A) public toilets

    1. press 5/km set in old town residential district, the new District 3-4/km set by each area of 30-60 square meters, set distance of 500-800 metres;

    2. the station, airport, Stadium (Museum), petrol stations and farmers ' markets and other crowded areas according to the 11-seat/km set, each floor area of 50-120 square meters, spacing was 300 m; 3. shopping centers, entertainment centers and other commercial financial district 11 seat/km set, each floor area of 50-120 square meters, spacing was 300 m;
    4. flow press 4/km set in sparse areas, each area of 50-120 square meters, spacing was 500 meters;

    5. trunk roads, secondary roads, pave the way for a fast set 1 500-800 metres along the road, each floor area of 50-120 square meters;

    6. the slip road, the pavement along the expressway by 800-1000 meters 1, each floor area of 50-120 square meters;

    7. the public toilets in the green belt along the River at 500 meters 1, each floor area of 50-120 square meters.

    (B) solid waste collection point set

    1. domestic waste collection service radius should not be more than 70 metres, with an area of not less than 40 square meters, building around the interval of not less than 5 m;

    2. waste bin set interval: Street 50-100 meters; trunk road, secondary road, Des Voeux Road Expressway 100-200 m; 200-400 meters of slip roads, sidewalks expressways;

    3. location of the refuse collection point should be set in both convenience and do not affect the non-street appearance city appearance;

    4. refuse collection points in the green belt along the River in accordance with the 300-500 settings in one place.

    (C) waste transfer stations, landfill

    1. set a small station by 2-3 square kilometers, with an area of not less than 800 square meters, building around the interval of not less than 8 m;

    2. waste transportation distance of more than 20 kilometers, should be set up for large and medium sized transfer station;

    3. refuse transfer station area shall be determined in accordance with rolling traffic, and shall be controlled in accordance with the scale of the large waste transfer station index table (schedule v) provisions; 4. refuse transfer stations should be beautiful in appearance, and should coordinate with the surrounding environment, operational closure, volume reduction, compression should be, the device should seek to advance.

    Dust, noise, odor, drainage and other indicators shall comply with the relevant environmental protection standards;

    5. refuse transfer stations to be set up waste weighing systems, weighing the garbage trucks came and large transfer stations should set up monitoring systems; 6. waste treatment facilities should be set in accordance with the current national laws and regulations, planning and standards requirements, facilities should be set up in urban areas with convenient traffic.

    Sanitary landfill, incineration, composting, recycling, shall, in accordance with their respective conditions, and should adhere to the local conditions, technically feasible and reliable equipment, appropriate scale, comprehensive treatment and utilization of principle, reasonable choose one of them or a combination.

    (D) car wash

    Roads into the city, and suburban settings wash and small car wash in the city shall be in accordance with the principles of unified planning, rational distribution, and in accordance with the relevant provisions of the environmental protection and sanitation.

    57th public service facilities construction shall conform to the provisions of the public service facility with index control table of indicators, and to comply with the following requirements:

    (A) the General layout of planning and building it should be made clear in the programme projects supporting the construction of public facilities, land and building area of municipal facilities, maps indicating the location and facilities listed and list of facilities planning, architectural design should conform to national norms, public service facilities should not be located in the basement with no natural light and ventilation;

    (B) construction project public service facilities in the building or high-rise towers first floor set overhead, but the floor area shall not exceed the total gross floor area of 30% overhead;

    (C) phased construction project the construction scale of the required size and corresponding population size should be the same supporting public service facilities, municipal facilities; (Four) construction project should according to City Road and buildings no obstacles design specification (JGJ50-2001), and elderly architectural design specification (JGJ122-99), and railway passenger station architectural design specification (GB 50226-2007), and disabled integrated service facilities no obstacles standard, and city public toilet design standard (CJJ 14-87), specification supporting construction no obstacles facilities, in Figure pieces in the marked set location,

    Barrier-free design and the words special.

    Article 58th urban residents in newly built or rebuilt buildings, residential areas, should post office letter box, letter box, newspaper mail room as resident buildings, residential facilities, and design units should be included in the design.

    Section II traffic facilities

    The 59th new construction, renovation of urban roads shall comply with the code for design of urban roads (CJJ37-90) requirements, and comply with the following requirements:

    (A) the urban road design and construction shall conform to the planning of way width and vertical elevation;

    (B) the road longitudinal slope below 5%, minimum longitudinal slope should be controlled between 0.3%-0.5%; special section of maximum longitudinal slope shall not exceed 9% and slope length depending on the design of slope and speed control;

    (C) urban road longitudinal slope shall not be plugged directly into the intersection should be equipped with secure transition zone, urban road longitudinal slope shall not exceed 3% within the intersection;

    (Iv) cross-street pedestrian overpasses and buildings, structure clearances shall not be less than 4.5 metres, pedestrian overpass bridge deck width shall not be less than the ladder width and underpass clearances shall not be less than 2.5 metres, cross the railway footbridge headroom, buildings and structures shall be not less than 6.5 meters;

    (E) urban elevated road and light rail line, highway through existing noise-sensitive buildings cluster, you should set up the sound barrier facilities;

    (F) road, the pavement along the height shall not be less than 0.2 m;

    (VII) new, renovation of urban roads shall be in accordance with specifications set blind, such as barrier-free facilities to the disabled;

    (VIII) special topography, location of city road construction, urban planning departments in accordance with the relevant provisions.

    60th new, rebuild city bridges according to the code for design of urban bridge (CJJ11-2011) regulations, and comply with the following requirements:

    (A) the construction, reconstruction planning way bridge clear width not less than wide;

    (B) bridge design should take into account the pipeline through, flammable, combustible piping should not be using traffic bridges across the river;

    (C) the Division should be consistent with the road cross section cross section of the bridge.

    The 61st constructed bus terminal station, hub station shall comply with the following requirements: (A) the bus station area at the end computed in accordance with bus lines introduced, a 1000 square meter each bus route.

    Bus line number determined according to the scale of development project construction, bus lines over three public transport interchanges;

    (B) the bus stops at the end of the first three conditions should be met: radius of buses in and out of traffic requirements, community service requirements, without disturbing the residential living environment;

    (C) residential area planning and construction standards: the size of the resident population reached 10000-16000 or 30000-50000 people, or in a residential district of the city road network ends or the edge of the city, and other needed setting up bus terminal station, as the case may be;

    (D) the culture of large shopping malls, supermarkets, sports facilities, exhibition halls and other large public venues should plan and have bus stations under construction, land area depending on the project size, but shall not be less than 2000 square meters; (E) Hub: development of projects relating to rail transfer points, planning, controlling and supporting public transit transfer hub.

    Public transit transfer hub can be set in the podium or the basement of a building, but the need to meet the requirements of public transit transfer hub technology, an area of public transit transfer hub and set standards depending on the circumstances.

    62nd city parking lots (garages) shall implement the following:

    (A) public buildings, public facilities and housing in accordance with the implementation provisions of the parking index table;

    (B) parking lots (garages) should be based on the nearest location, land conservation, using the principles of topography, underground or in multi-storey garages should be adopted;

    (C) motor vehicle parking entrance shall comply with the requirements of driving sight distance, turn right and access to the driveway; (Four) parking out entrance should distance people line overpasses, and authentic and bridge, and tunnel ramp start line 50 meters far; and City Road exists layer poor of underground parking library out entrance, in principle only set in project internal road Shang, does for conditions limit, by urban and rural planning competent sector organization argument Hou can in city support road opening, but should set not is less than 5 meters of ramp paragraph, and on road opening for widened Canal of; 50 a spaces following of parking can set a access mouth, net width not is less than 7 meters ; 50-100 a spaces of parking, should set two a out entrance, out entrance distance should is greater than 20 meters; 101-300 a spaces of parking, should set two a out entrance, out entrance distance should is greater than 20 meters, two a out entrance NET width not is less than 7 meters; 301-499 a spaces of parking, export and entrance separate set, two a out entrance distance should is greater than 20 meters, two a out entrance NET width not is less than 7 meters; is greater than or is equal to 500 a spaces of parking,

    Set three or more entrances;

    (E) the underground entrance to the garage access control system from the garage access road shall be not less than 10 m;

    (Vi) vehicle parking entrance opening on the municipal road, distance from the intersection of municipal road should meet the main road is not less than 80 meters, secondary road provision of not less than 70 m.

    63rd city public gas stations, gas stations and other facilities service RADIUS appropriate to 0.9-1.2 km, total planning, site selection, layout and design should be consistent with the urban landscape, transportation, fire protection, and other related regulations.

    64th following new project design reviews, traffic impact assessment report shall be compiled:

    (A) a loop within the city's main roads and secondary roads, urban expressways and trunk within the second ring road, within the third ring road urban Expressway;

    (B) the total floor area of more than 20,000 square meters within a ring;

    (C) the second ring houses a total construction area of more than 80,000 square meters, total construction area of more than 50,000 square meters large public buildings;

    (D) the second ring outside the House a total construction area of more than 150,000 square meters, total construction area of more than 100,000 square metres of large public buildings;

    (E) shall carry out a traffic impact assessment of other construction projects.

    Traffic impact evaluation, additional requirements for traffic engineering and transport infrastructure, such as road widening, additional pedestrian crossing the channel, traffic signs and markings, traffic signals, parking space configuration of the system, designed by project construction unit synchronized, synchronized building put into use and synchronization, synchronization check.

    65th under any of the following circumstances, you can set the stereo-pedestrian facilities:

    (A) the crosswalks downtown closed roads, expressway or vehicle lane width greater than 25 m, every 400-800 meters can be set;

    (B) the car traffic on the section of bi-directional equivalent up to 1200 km/h, or pedestrian crossing the street more than 5000 persons per hour;

    (C) some special needs and turning complicated, there is an obvious danger to pedestrians.

    66th in urban rail line passes through zones shall define control of rail transit corridors to protect the boundaries, and to comply with the following requirements:

    (A) the construction of urban rail transit corridor based on urban rail transit network planning, built and planned lines control line should be identified and incorporated into urban land-use control and protection planning issues;

    (B) rail traffic control boundaries based on engineering geological conditions, construction technology and engineering practical experience on the ground, determine the planning, control and protection line;

    (C) in planning, control and protection within the boundaries, shall be restricted to new types of large buildings and underground structures below the crossing the rail structures, reservation and protection measures need to be developed and coordinated with the rail transportation departments to ensure structural stability and operation safety of rail transit lines, and implementation of the project was carried out;

    (D) new rail traffic in the narrow roads in the built-up area of the city area, planning, control and protection within the boundaries, its construction should pay attention to the security implications of adjacent buildings, and take the necessary demolition or security measures;

    (E) the elevated and surface lines in the land expropriation scope of municipal road outside the red line bridge suitable projection surface of the structure as the standard, the roadbed is subject to natural berm about 1 m, and according to specific circumstances determined in consultation.

    Section III drainage facilities

    67th new development projects in accordance with the following provisions of article designing rainwater and sewage shunting and supporting construction of water recycling facilities: (A) construction project outside urban rain, the sewage diversion system, construction projects within the rain, sewage piping shall be seamless access services, respectively, dirty system, it should be made clear in the total figure had built the city rain, sewage pipes, pipe diameter, interface, check the hole location, coordinates, municipal pipe interface elevation, access higher in the project pipeline.

    Construction project internal pipes, septic tanks, sewage treatment facilities and other structures the retreat planning roads, red 3 m;

    (B) the total floor area of over 100,000 square metres of residential projects, or a total construction area of over 50,000 square meters of public buildings, hotels, commercial centers and other projects, as well as external no municipal sewage systems, or have built external sewage systems cannot accommodate projects of treatment capacity, construction projects should be supporting the construction of sewage treatment facilities and water reuse systems;

    (C) sewage treatment facilities, water recycling systems, septic tanks, rain water and sewage pipelines should be synchronized with the simultaneous design of construction projects and legal approval, simultaneous construction, acceptance, synchronization inputs used; sewage treatment facilities, water reuse system is completed, it should be submitted to the relevant authorities in accordance with law approval or for the record.

    Construction project construction of sewage treatment facilities, water reuse systems in accordance with "who cares who built the" principle of operation managed by the project development unit, subject to government control.

    Fourth power facilities

    68th high voltage corridor in accordance with the following arrangements:

    (A) involved in urban planning for high voltage corridor for 110,000-volt power line corridors and above, shall, in accordance with the overall urban planning, integrating urban high-voltage lines and corridors of the corridors, and cable channels;

    (B) the 500,000-volt overhead lines should be reserved corridor, at 110,000 and 220,000-volt lines in them, when conditions permit, should be reserved for the aerial corridors.

    Planning and construction of city centres and core area of 110,000 and 220,000-volt line cables should be used underground.

    69th overhead lines in accordance with the following layout:

    (A) overhead lines should be based on urban topography, geomorphic characteristics and requirements of urban road planning, along the mountain, River, green zones and erection of roads, route selection should take into account the urban planning construction land, to avoid crossing;

    (B) the new transmission line corridors along the planned high-voltage as possible focus on laying high voltage corridor planning development of key development areas, the present situation should be avoided as much as possible, public open space, environmentally sensitive areas or seriously affecting the landscape of the area.

    Urban corridor for overhead lines control indicators should be consistent with the urban transmission line corridor width control provisions of the index table.

    70th city roads set on electric power facilities shall comply with the following requirements:

    (A) subject to conditions agreed to by the relevant departments according to law and to demonstrate, is really necessary to set up 110,000 volts and above-grade power pole road shall not be erected other overhead lines pole road;

    (B) set the transfer box power transformers, communications, gas regulators (box) facilities shall not occupy urban road pavement.

    City sidewalks have been set on overhead wires and facilities, should be combined with urban road reconstruction gradually standardize burial.

    In the power lines within the scope of protection shall be constructed buildings and structures.

    71st voltage power line protection zones in accordance with the following provisions:

    (A) overhead protection shall comply with the overhead lines distance control indicators the scope of protection stipulated in the table;

    (B) underground power cable line protection zones, extending toward the lateral distance on each side should be not less than 0.75 m.

    Electromagnetic radiation above the exemption level construction projects, high-voltage power transmission and transformation facilities, radio towers, electromagnetic environment impact assessment should be carried out.

    Fifth section pipe network

    72nd city pipeline shall, depending on the pipeline feature and set up requires a combination of layout, all kinds of pipeline between the horizontal and vertical spacing and pipeline and the minimum horizontal spacing between buildings and structures, in accordance with the code for urban engineering pipeline comprehensive planning (GB50289-98) requirements. 73rd along city road planning and construction of the underground pipeline to be parallel with the center line of the road, its depth shall be determined in accordance with safety requirements for elevation and pipeline road, in the town's sidewalk construction trench within its precast trench cover plates shall not be exposed to ensure that pedestrians.

    Road width of 30 meters and above the red line of the main roads, pipelines can be a two-sided wiring.

    74th engineer after completion of pipeline laying should be taken as the final survey, urban and rural planning departments report.

    75th pipes on primary and secondary roads in the city, according to the requirements of urban planning and development should be to determine pipe size, leave room to avoid or reduce duplication of excavation roads.

    Sixth section, other facilities

    76th urban fire facilities, fire stations and other settings, in accordance with the relevant standards.

    77th comprehensive disaster planning shall, in accordance with the relevant requirements, clear fire stations, shelters, emergency public safety facilities, such as channel number, layout, size, RADIUS, scope of services, and so on.

    Prohibit changing the nature of emergency shelters with planning permission.

    78th install outdoor advertising facilities shall comply with the following provisions:

    (A) should not be used hanging advertising;

    (B) outdoor advertising shall not block the city landscape, urban greening, landmarks, transport facilities, Memorial building, party and Government organs, cultural relics, shall not affect the adjacent buildings, lighting, ventilation, traffic, fire;

    (C) not on Center segregation of the road railings and set within the turning range of the vehicle;

    (D) install outdoor advertising facilities, Guiyang in conformity with the relevant provisions of the conditions.

    79th in urban roads, squares, parks and other public places to construct the city sculpture, shall conform to the urban planning and coordination with the urban landscape, the environment.

    Nineth part of urban green space

    80th of urban road greening rate shall comply with the following rules: (A) landscape road greening rate shall not be less than 40%, the red line widths greater than 50 meters of road greening rate shall not be less than 30%, the red line width of 40-50 meters of road greening rate shall not be less than 25%, the red line width of less than 40 metres of road greening rate shall not be less than 20%; road layout,

    Planting trees of green belt width shall not be less than 1.5 meters, trunk road cars on the green belt of a width not less than 2.5 metres, street tree green belt width shall not be less than 1.5 m; old town rebuilding roads can reduce, as appropriate, but shall not be less than the above mentioned ratio of green space index of one-second;

    (B) planting tall trees around the public square should be concentrated into green spaces should not be less than the total square area of 25%;

    (C) in station, dock, airport terminal square tree species for afforestation with local characteristics should be established, focus on vast stretches of green space should not be less than the total square area of 10%;

    (D) the car park plant height under the shade tree branches shall comply with the provisions of parking space clear height: 2.5 m for small cars, midsize car for the 3.5 m, truck is 4.5 metres;

    (E) the trees green and with no pipelining, the minimum horizontal distance from trees and other facilities should be consistent with the trees and other facilities the minimum horizontal distance from the control provisions of the index table.

    81st residential area shall comply with the following provisions:

    (A) new residential, residential, green living group configuration in accordance with the code for planning design of urban residential area (GB50180-93) of the Executive;

    (B) green space in residential areas, in accordance with the appropriate scale configuration public green space, green space, supporting public-owned green space and green space;

    (C) the ratio of green space: new construction should not be less than 30%, redevelopment is not less than 25%;

    (D) the Group of public green space sets shall meet not less than 1/3 of green areas outside the standard architecture of Sun shadow line, and easy to set up children's play facilities and accommodate adult recreation activities;

    (E) the total indicators of public green space of residential areas should be based on the size of the resident population, respectively: not less than 0.5 square metres per person for a group, community (including groups) not less than 1 square metre per person, residential area (including communities and groups) not less than 1.5 square metres per person, and shall be arranged according to the planning and organizational structure types, flexible use.

    Transformation of old urban areas can be reduced, as appropriate, but should not be lower than the target of 70%.

    The 82nd new industries with green space in other buildings executed in the following control indicators:

    (A) Administrative Office greening rate of not less than 35%;

    (B) financial and commercial green rate of not less than 20%;

    (C) cultural, recreational, hotel green rate of not less than 35%;

    (D) schools, hospitals, nursing homes, government agencies and organizations, public cultural facilities, army green rate of not less than 35%;

    (E) industrial enterprise green rate not greater than 20%, polluting industrial project green rate according to the relevant regulations;

    (F) the logistics warehouse open space greening rate of not less than 20%;

    (VII) other construction projects green rate of not less than 25%.

    83rd no unit or individual without changing the plan of green space in nature. 84th building site urban road construction of entity part of the wall, you can build the flower bed, green hedge as a border buffer zone.

    Due to special reasons such as using absolutely necessary to the construction of the wall, it shall be reported to the town and country planning authorities, and shall comply with the following requirements:

    (A) the permeability of the wall, not exceeding 1.6 metres in height;

    (B) special requirements necessary to build enclosed fence, fence height shall not exceed 2.2 meters, and beautification of its finishes and looks.

    The tenth chapter supplementary articles

    85th on April 1, 2004, to the date of implementation of this approach has been the approval of constructional detailed planning of construction projects, in accordance with the approved detailed construction planning and programme implementation; prior to April 1, 2004, approved a construction plan also fails to go through the details of the construction project planning permit for construction project, as well as from the date of implementation of this approach to the new construction project, according to the implementation of these measures. 86th these measures come into force on January 1, 2013.

    Published on February 18, 2004, as of April 1, 2004 of the Guiyang municipal urban planning technical regulations repealed simultaneously.

    Annex 1: glossary

    , City planning area: from Yongle of Wudang district in the East, West of hongfeng Lake, qingzhen city, South of huaxi district qingyan, North to the long field, zazzo, xiuwen, include the city's six districts (Wudang district of nanming district, huaxi district, Baiyun district of Yunyan district,, and, and, and, and, and, Xiaohe district) and the hongfeng Lake, qingzhen city town, Bai Hua Hu Xiang xiuwen and long Chang Zhen, Zha Zuo Zhen, 3121 square kilometers of the total area.

    Two or one ring, and II ring, and three ring: a link refers to Baoshan road, and Liberation road, and Wun Sha Road date mountain, and Beijing road surrounding collection of city planning district range; II link refers to North II ring, and East II ring, and South II ring, and West II ring surrounding collection of city planning district range; three link refers to southwest around city high-speed, and Northeast around city high-speed, and South link around city high-speed surrounding collection of city planning district range.

    Three, shanty towns: refers to state-owned land and the surrounding houses scattered on land simple structure, dysfunction, and building density, per capita living space is less, building life long, supporting infrastructure, law and order and the fire hazard and environment "dirty, chaotic, and poor" towns and State-owned enterprises (including State-owned holding enterprises) population is concentrated into living areas.

    Four, village: is the city urban planning area within, has entered the urban planning area in the region, but household registration, land ownership, management and administration systems, production operations remain inhabited villages in the rural system.

    Five, and construction with to area: to urban and rural planning competent sector delineation of with to range deduction city road planning red with to and the River, and drainage route planning of blue line with to, and protection green, and Hill green, and Park Green, public green, and high pressure corridor, control with to Hou for construction with to, participation building capacity index calculation; above deduction of with to are cannot participation building capacity index calculation.

    VI floor area ratio: within a certain block, above ground area (except the semi-underground car parking lot and half underground equipment rooms) and the ratio of building area.

    Seven, building density: certain plots of land on the Mainland in the buildings (except the semi-underground car parking lot and half underground equipment rooms) of basal area percentage of construction area. Eight, the ratio of green space: within a certain block, green area of construction land area percentage.

    Public green areas, public facilities owned green space, green space and meet the afforestation soil depth of not less than 1.5 metres from the ground, semi underground construction and green space open to the public at the top; using terrain elevation difference of construction projects, fire engines can go directly to the roof and building roof afforestation soil depth of not less than 1.5 metres of green space, green area included green rate.

    Nine, the architectural space: refers to both horizontal and vertical distance between the outer wall of the building.

    Ten, building height: from outdoor ground elevation to roof level or parapet height of the top surface.

    Third, the lower House: layer 1-3 layer houses.

    12, multistory: layer 4-6 layer houses.

    13, senior housing: layers for 7-9-storey house.

    14, high-rise housing: layers of 10-storey and above level 10, building height is less than 100 metres from the House.

    XV, high-rise residential: residential building height is greater than or equal to 100 meters.

    16, public building: refers to public services or social housing construction, includes office buildings, commercial buildings, tourism building, science, medical buildings, communications, construction and transportation construction.

    17, high-rise building: building height over 24 meters is less than 100 meters of public buildings.

    18, super high-rise public building: building height is equal to or greater than 100 metres from the building.

    19, building line: refers to the planning and construction of lines and size of the bounding box, as well as planning and architecture outside the box line and the adjacent City Road, next to control labeling of architectural space.

    Red line 20, road: planning and road cross section of two control lines.

    21, River blue line: two line of planning the river cross section.

    22, and the green line: green space the line of control.

    23, overhead: in the building or high-rise towers first floor setting without any structure exterior-floor, elevated floors should be greater than or equal to 4.2 m, the owner of set free and convenient direct access to green spaces, recreational space, free all day for the owners, may not set up the nature of the business project.

    24, the underground power cable line protection zones: refers to an underground power cable lines extended out both sides formed by two parallel lines in the area. 25, structural (device) conversion layer: that building the floors of upper and lower plane to use different functions, the upper and lower floors in different structures (equipment) type, and through the floor structure (devices) conversion.

    Separate structures (devices) when converting layers, layers should be less than 2.2 metres high.

    26, Zhi: planning road width is greater than or equal to 12 m, 20 m or less, and not less than two-lane city road.

    27, cigan road: planning road width greater than 20 metres, less than or equal to 30 meters, and lane not less than 4-lane urban road.

    28, the main road: planning road width is greater than or equal to 32 m, 60 m or less, not less than 6-lane City Road and lane. 29, high-speed rail: new design speed of not less than 250 km/h, the old line modification design speed of not less than 200 km/h.

    Guiyang City territory are: Cheng Gui railway, Chongqing-Guizhou railway, long Nanning-Kunming railway, GUI-Guang railway, city rail, your open railway and so on.

    30, viaducts range: including the most outer edge of way road under the viaduct. 31, main line railways: the Guiyang-Kunming railway, Sichuan-Guizhou railway and Xiang-Qian railway and Guiyang, Qian-GUI railway, fillistered railway junction (putie). Apart from the high-speed railway, the spur line railway, a private railway, the railway.
    32, and a level processing, and II level processing, and three level processing: a level processing is mechanical processing, as grid gate, and precipitation or gas floating, removal sewage in the by containing of stones, and gravel and fat, and oil,; II level processing is biological processing, sewage in the of pollutants in microbial of role Xia was degradation and into for sludge; three level processing is sewage of depth processing, it including nutrition real of removal and through added chlorine, and purple outside radiation or ozone technology on sewage for disinfection.

    Annex 2: rules

    Area a, building density and floor area ratio calculated in accordance with the following rules:

    (A) live building layer high is greater than 3.6 meters, is less than or is equal to 5.8 meters (that 3.6+2.2) Shi, regardless of layer within whether has sandwich, its meter capacity area by the layer level projection area (not containing balcony part) of twice times calculation; Dang layer high is greater than 5.8 meters, is less than or is equal to 8.0 meters (that 5.8+2.2) Shi, regardless of layer within whether has sandwich, its meter capacity area by the layer level projection area (not containing balcony part) of 3 times times calculation, and so on;

    (Ii) General commercial building, dang layer high is greater than 6.0 meters, is less than or is equal to 8.2 meters (that 6+2.2) Shi, regardless of layer within whether has sandwich, its meter capacity area by the layer level projection area of twice times calculation; Dang layer high is greater than 8.2 meters, is less than or is equal to 10.4 meters (that 8.2+2.2) Shi, its meter capacity area by the layer level projection area of 3 times times calculation;

    (Three) large commercial building, dang layer high is greater than 6.6 meters, is less than or is equal to 8.8 meters (that 6.6+2.2) Shi, regardless of layer within whether has sandwich, its meter capacity area by the layer level projection area of twice times calculation; Dang layer high is greater than 8.8 meters, is less than or is equal to 11 meters (that 8.8+2.2) Shi, its meter capacity area by the layer level projection area of 3 times times calculation, and so on, has special function requirements of should topic argument;

    (Four) Office, and hotel building layer high is greater than 5.5 meters, and is less than or is equal to 7.7 meters (that 5.5+2.2) Shi, regardless of its layer within whether has sandwich, its meter capacity area by the layer level projection area of twice times calculation; Dang layer high is greater than 7.7 meters is less than or is equal to 9.9 meters (that 7.7+2.2) Shi, regardless of its layer within whether has sandwich, its meter capacity area by the layer level projection area of 3 times times calculation, and so on;

    (V) the calculation rules (a), (b), (c) listed in all kinds of buildings the public part of the entrance hall, lobby, Atrium has special features require a layer of building parts-high computer capacity building area;

    (Six) jump layer type live building living room (Office) of households within pass high part not over the layer sets within area of 35% and height not is greater than 7.2 meters of, the pass high part of meter capacity area by the layer level projection area of 1 time times calculation; pass high part over the layer sets within area of 35% or height is greater than 7.2 meters of, according to this calculation rules subsection (a) items calculation;

    (G) living room (Hall) parts other than (not including balcony) appear high when calculated in accordance with the rules (a) calculation; (H) the bottom of residential buildings or commercial, Office overhead part of the podium height greater than or equal to 3.6 meters, less than or equal to 4.8 metres, and for green public leisure space, its an area of excluded volume, but the total area to be included in the project.

    Super high-rise building fire protection is absolutely necessary to set up refuge floors, refuge area not included in the volume area, but need to take into account the total construction area of the project; (I) business and the volume of commercial and residential building by the percentage of floor space of a different nature, in accordance with (schedule a) targets set by conversion of synthesis.

    The building density in accordance with the (first) of the target implementation;

    (J) commercial floor space or Office floor space of the building area of 10% is not, or only the bottom for comprehensive residential commercial or Office, plot ratio (schedule I) housing indicators in implementation, building density (schedule a) business indicators in implementation;

    (11) no podium ground floor for commercial or Office or apartment building, its plot ratio, density (schedule I) housing indicators in implementation;

    (12) building according to the requirements of article 17th after determining elevation ± 0.00, elevation ± 0.00 above ground buildings, elevation ± 0.00 following is underground and semi-underground buildings;

    (13) the half-basement floor parking garage or a free parking garage, its building area is not included in the volume, but its area to be included in the total construction area of the project, and should meet the spacing requirements and adjacent buildings;

    (14) all underground space for commercial, offices, warehouses and other business purposes, not included in the volume, but shall, in accordance with the relevant provisions to pay the corresponding fees;

    (15) the semi-underground space for commercial, offices, warehouses and other commercial purposes, its area included in the plot ratio and building density;

    (16) building industrial projects more than 8 meters high, in calculating the volume of the building area of double.

    Second, building the number calculated in accordance with the following provisions:

    (A) when the residential and other functions when it is in the same building, housing should be part of the layers and other functional space of the layer stack to calculate building layer; (B) the housing top has a two-story duplex sets when the wall-to-wall between two slabs are still calculated according to the two-story, part for part of the floor and over, according to one calculation.

    For fire control, according to the natural number of floors;

    (C) building the layers within layers arranged in accordance with the following provisions: 1. Interior Design floor elevation of plus or minus zero, according to the permutation is called a layer. Architectural design files should be marked in the floor order architectural layers, a layer may not be headed by mark or the bottom, first floor above as second-tier, by analogy to architecture at the highest level for this rule.

    Not more than 2.2 metres high regardless of the layer;

    2. Interior design elevation below plus or minus zero layer, according to the permutation is called a ground floor, basement floor slabs hereinafter referred to as two-level, underground, by analogy to building's basement for this rule the lowest layers;

    3. the fee if a sandwich between the layers above the ground, that are not included in the number, but large public buildings with atrium, surrounded by floors according to calculated in accordance with the second paragraph of rule (c) 1th Section arranges to call;

    4. Dang indoor by stairs rest platform of elevation set different elevation of floors for wrong layer, its wrong layer of building layer number, to elevation for plus or minus zero of floors (a layer) for standard, second layer floor surface elevation following of the layer building layer number for a layer (different elevation of floors should respectively indicate elevation), layer number of mark method by this rules analogy.

    Third, the building height is calculated according to the following rules:

    (A) flat roof without parapet roof buildings, building height measured from the outdoor ground to the top of the cornice, as has a parapet roof, count to the parapet top;

    (B) the construction, height is to the sloping cornice top; slope roof slope of 30 degrees or less, calculate the height is to the cornice; greater than 30 degrees, height is to the roof;

    (C) stairways, elevators, water tank on the roof, chimneys, roof decoration of buildings without building height calculation for clearance or other control of height requirements, by the Department of town and country planning of the validation;

    (D) the building part of the order, order can be calculated; (E) building a free and a height greater than or equal to 2.2 meters, can count on the free surface of the first layer to the top of a building.

    Less than 2.2 m high structure (devices) high conversion layer, suspending the aerial layer and layer is equal to or greater than the top of the 2.2 m leap Number of floors is not calculated, but shall be included in the total height, and a separate description. Four, home gardens, balconies, in accordance with the standard measurement for construction area (GB/T50353-2005), balcony in 1/2 area of rule execution.

    Any of the following circumstances shall be implemented in accordance with the following rules:

    (A) complies with the following standards of residential balcony, counted according to envelope the horizontal projection of one-second, if it does, more than calculate the total area: 1. floor area refers to the external wall (cylinder) feet above the level of peripheral projection area.

    And below 90 square meters apartment, balcony level projection area (with balcony and floor plan) sum of not more than 12 m;

    2. the area of 90 square meters-the 140 square meters apartment, balcony level projection area does not exceed 15 m;

    3. more than 140 square meters of dwelling and terrace level projection area does not exceed 18 square meters; 4. affordable housing, low-rent housing, public rental housing the terrace area can refer to an area of 90 square metre apartment standard.

    Otherwise the provisions of the State, from its provisions;

    (B) the inner balcony, balcony depth (extending from the outer edge of the main structure to the indoor vertical distance) of not more than 1.5 m, calculate the area of one-second; more than 1.5 metres, over all parts of an area;

    (C) the cantilevered balcony depth (most outside the vertical distance to the outer edge of the main structure) is not greater than 0.6 meters, is not counted; greater than 0.6 meters, calculating the area of one-second; (D) the first cover vertical height of balcony floor two and two following natural levels of balconies, calculate the area of one-second.

    More than two natural layers, and no horizontal cut in floor first cover vertical space floor, connecting beams, wall structure, such as body, is not counted, or calculate the floor area of one-second;

    (E) the balcony covered peripheral projection lines and balcony structures when, in accordance with the level of projected area small area one-second area; cover width not greater than 0.6 meters, is not counted; (F) residential buildings belonging to a proprietary air similar to a balcony garden, home garden, a panoramic terrace, regardless of its name, provided that they meet the balcony-defined, calculated according to the balcony area.

    Not in accordance with the construction area of the balcony, then calculate the total building area.

    Five flower beds according to the following rules:

    (A) shall not be outside on the balcony or outside wall of high-rise residential building outside pond, low, multi-storey residential buildings on the balcony outside or exterior settings pond, place the bottom of the pot and the building fall protection measures to be taken;

    (B) low, multi-storey residential buildings on the balcony outside or exterior set at the pond, pond bottom greater than room floor or balcony floor 0.6 meters, flower beds are not included in the volume area;

    (C) the pond floor below interior floor or balcony floor 0.6 meters, set inside or on the balcony floor garden, area at balconies provisions included in the volume rates.

    Six, Bay Windows that meets the following criteria, are not included in the volume area:

    (A) highlight the outside wall;

    (B) the window sill and interior floor height greater than 0.45 m;

    (C) the sill plate distance from outer edge to outer wall surface is less than 0.6 m.

    Does not meet the above conditions, or set up a wall, floor layer projection surface within the window, should be in accordance with a comprehensive product included in the volume area.

    Annex 3 the drawings

    (Editor's Note: this annex drawings see manuscript) Annex 4

    Schedule

Schedule:
Density and volume control indicator table
┌──────────────┬───────────────────────────┐
│                            │                  控制范围及控制指标                  │
│                            ├────────────┬──────────────┤
Highly │ │ buildings other than a link within a link │ │
│                            ├───────┬────┼───────┬──────┤
│ │ Building density (%) │ │ building volume rate density (%) ¦ volume │
├──────────────┼───────┼────┼───────┼──────┤
│低层住宅(1-3层)           │      40      │  1.2   │      35      │    1.2     │
├──────────────┼───────┼────┼───────┼──────┤
│多层住宅 (4-6层)          │      30      │  1.8   │      30      │    1.8     │
├──────────────┼───────┼────┼───────┼──────┤
│ High-rise (7-9) ¦ 30 │ │ 30 2.2 2.2 │
├──────────────┼───────┼────┼───────┼──────┤
│ High-rise buildings (above level 10) ¦ 25 │ │ 25 4.0 3.5 │
├──────────────┼───────┼────┼───────┼──────┤
│ Super high-rise residences (a height of 100 metres and 100 metres ¦ 25 │ │ 25 5.0 4.5 │
│以上150米以下)             │              │        │              │            │
├──────────────┼───────┼────┼───────┼──────┤
│ │ 40 public buildings under a height of 24 meters │ 35 │ │ 3.5 3.5 │
├──────────────┼───────┼────┼───────┼──────┤
│ Below 24 metres in height and 24 meters above the 100 m ¦ 35 │ │ 30 6.0 5.0 │
│高层公共建筑                │              │        │              │            │
├──────────────┼───────┼────┼───────┼──────┤
│ Height of 100 metres and 150 metres to 100 metres above ¦ 30 │ │ 25 8.0 7.0 │
│下超高层公共建筑            │              │        │              │            │
├──────────────┼───────┼────┼───────┼──────┤
│厂房及库房                  │      /      │   /   │    40以上    │  0.5-2.5   │
├──────────────┴───────┴────┴───────┴──────┤
│    备注:                                                                          │
│ 1. building density and floor area ratio in the table control to a maximum value (apart from the plant and warehouse building density index) │
│ 2.150 m and 150 m super high building density, plot ratio control of the building by the Department of town and country planning in accordance with the │
│市景观等要求具体确定;                                                              │
│ 3. when in shanty towns, village, the building density and floor area ratio control by the Department of town and country planning │                                                                                │.


┖──────────────────────────────────────────┘

                              Schedule II:
Sunshine technical parameters table

┌─┬──────────────┬─────────┬──────────┐

│  │         分析标准日         │       大寒       │        冬至        │

│技├──────────────┼─────────┼──────────┤

│ │ Analysis start time (solar time) │ 8:00-16:00 │ 9:00-15:00 │

│技├──────────────┼─────┬───┴──────────┤

│ │ │ │ Point longitude Guiyang City Latitude 26 ° 34 ' │

│术│                            │          │       东经106°42′        │

│  ├──────────────┼─────┴──────────────┤

│参│分析采样间隔时间            │                 5分钟                  │

│  ├──────────────┼────────────────────┤

│ │ │ Analysis height ground floor window with sunshine requirements ¦

│  ├──────────────┼────────────────────┤

│  │计算方法                    │           总有效日照(累计)           │

└─┴──────────────┴────────────────────┘

    附表三:
Different azimuth spacing reduction coefficient tables
┌─────┬─────┬─────┬─────┬─────┬──────┐
│ Directions │ 00-15 │ 450-60 │ 300-45 │ 150-30 ° ° ° 600-90 ° ° ¦ ¦
│          │  (含)  │  (含)  │  (含)  │  (含)  │   (含)   │
├─────┼─────┼─────┼─────┼─────┼──────┤
│ Reduction │ 1.0L │ 0.9L │ 0.8L │ 0.9L │ 0.95L │
├─────┴─────┴─────┴─────┴─────┴──────┤
│    备注:                                                              │
│ 1. position in the table for the South (0 °) on the East and West side of the azimuth angle (see figure II), │
│ 2.L to residential standards for just south of Guiyang sunshine distance; │
│ 3. This table only apply to no other sunshine between the parallel arrangement of block apartments; │                                │ 4. Sunshine distance to South side, East of the building height calculation.


└────────────────────────────────────┘

Schedule IV:
Road building concessions on city roads the red line control table
┌──────────────────┬─────────────────────────┐
│                                    │                     道路等级                     │
│              建筑退让              ├──────────┬──────────────┤
│                                    │   30米及30米以上   │          30米以下          │
├──────────────────┼──────────┼──────────────┤
│                                    │  退道路红线(米)  │      退道路红线(米)      │
├──────────────────┼──────────┼──────────────┤
│高度24米以下建筑                    │         5          │             5              │
├──────────────────┼──────────┼──────────────┤
│ Below 24 metres in height and 24 meters above the 50 m building ¦ 10 ¦ 8 ¦
├──────────────────┼──────────┼──────────────┤
│ 50 meters and 50 meters height or above 100 m building ¦ 12 ¦ 10 ¦
├──────────────────┼──────────┼──────────────┤
│ 100-metres in height and more than 100 meters below 150 meters building ¦ 15 ¦ 15 ¦
├──────────────────┼──────────┴──────────────┤
│ Height of 150 meters and 150 meters or above building │ after detailed evaluation by competent authorities according to the circumstances of urban and rural planning, municipal │                                        │                                    │批准执行。

├──────────────────┴─────────────────────────┤
│    备注:                                                                              │
│    1.表中数字为控制的下限值;                                                          │
│ 2. of tall building with podium, podium and some concessions from senior concession requirements should be met; │
│ 3. concession from the building, a building and building overhang along the side of the real projective line calculation of urban roads; │
│ 4. concession municipal facilities as the case may be integrated into the building planning range of buildings and used as urban pipelines, urban rail │
│ Road, the construction of municipal public facilities such as road widening the lane; │
│ 5. underground buildings should yield land border not less than 3 m building; │                             │ 6. underground buildings city roads should give city of way not less than 5 m to build.


└────────────────────────────────────────────┘

Schedule Friday:
Large garbage transfer station scale control table
┌──────┬─────────┬────────────┬───────────┐
│ Transport capacity (ton) │ area (square meter) │ subsidiary building area (m2) │ green belt width (m) │
├──────┼─────────┼────────────┼───────────┤
│   ≤150    │      ≤3000      │          ≥10          │         ≥5          │
├──────┼─────────┼────────────┼───────────┤
│ 150-450 │ 2500-10000 │ │ ≥ 8 ≥ 15 │
├──────┼─────────┼────────────┼───────────┤
│   >450    │      >8000      │          ≥30          │         ≥15         │
├──────┴─────────┴────────────┴───────────┤
│ Note: 1. the table in the area does not include land for waste sorting and stacking operations; │ │ 2. land area included in the Greenbelt along the surrounding land. Land area can be increased according to the greening rate; │
│ 3. table transit volume calculated according to daily work shifts; │
│ 4. elected land use indicators as a superposition of two parts, lower grade of green belt can be used indicators │                                            │ 5. secondary station slightly limit selected indicators.


└─────────────────────────────────────────┘

Schedule VI:
Public facilities construction
┌─────┬─────┬────┬───────────┬─────┬───────────────┐
Planning planning │ │ │ │ application area of public construction in the number area of │ │ plans setting requirements ¦
│ 数(户) │  (人)  │  名称  │                      │          │                              │
├─────┼─────┼────┼───────────┼─────┼───────────────┤
│          │          │治安值班│15平方米              │          │组团入口                      │
│          │          │室      │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ Garbage collection │ │ services │ 40 square meters radius of less than 70 meters │
│          │          │点      │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
20-50 square post │ │ │ │││ communities community portal or in combination with room for community service │
│          │          │服务站  │                      │          │置                            │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │居委会办│每50户配套10平方米,不│          │                              │
│││ Public service │ │ │ 50 foot by 50 meter set, in principle, in the 1 or 2 floor │
│          │          │房      │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │社区文化│不少于50平方米        │          │                              │
│ 300-1000 │          │图书室  │                      │          │                              │
│ (组团) │1000-3000 ├────┼───────────┼─────┼───────────────┤
│ │││ Sports venues per capita more than 1.08 sq │ │ PE │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │        │总建筑面积不足10万平方│          │                              │
│          │          │        │米的,物业服务用房按照│          │                              │
│          │          │        │总建筑面积3‰的比例配 │          │                              │
│          │          │        │置,最低不得低于90平方│          │                              │
│          │          │        │米;总建筑面积在10万平│          │                              │
│││ Property services │ square meters above, property services │ │ Guizhou province, in accordance with the management regulations of │
│          │          │用房    │房的配置以300平方米为 │          │设置                          │
│          │          │        │起点,超过10万平方米的│          │                              │
│          │          │        │部分,按照超过部分建筑│          │                              │
│          │          │        │面积2‰的比例增加配   │          │                              │
│          │          │        │置,超过50万平方米的部│          │                              │
│          │          │        │分,按照超过部分建筑面│          │                              │ ││││ Configure volume increase in the proportion of 1 per thousand.
│          │                              │
├─────┼─────┼────┼───────────┼─────┼───────────────┤
│          │          │社区卫生│150平方米             │          │                              │
│          │          │服务站  │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │再生资源│10平方米              │          │                              │
│          │          │回收点  │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │文化图书│100平方米             │          │                              │
│          │          │室      │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│ │││ Sports venues per capita more than 1.08 sq │ │ PE │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │警务室  │30平方米              │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ 800-1000 square farmers market │ │ │ service RADIUS 500-800 metres │
│          │          │        │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│ 1500-3000 │ 4500-9000 │ │ every 50 households of the neighborhood set 10 meters, │ │ not in connection with the Guiyang Downtown Community Office services │
│ (Community) │ │ service │ 50 foot by 50 meter │ │ room layout plan, set principles │
│          │          │房      │                      │          │上安排在1楼或2楼              │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │        │总建筑面积不足10万平方│          │                              │
│          │          │        │米的,物业服务用房按照│          │                              │
│          │          │        │总建筑面积3‰的比例配 │          │                              │
│          │          │        │置,最低不得低于90平方│          │                              │
│          │          │        │米;总建筑面积在10万平│          │                              │
│││ Property services │ square meters above, property services │ │ Guizhou province, in accordance with the building management Ordinance │
│││ Room │ set configurations with 300 square meters for │ │ │
│          │          │        │起点,超过10万平方米的│          │                              │
│          │          │        │部分,按照超过部分建筑│          │                              │
│          │          │        │面积2‰的比例增加配   │          │                              │
│          │          │        │置,超过50万平方米的部│          │                              │
│          │          │        │分,按照超过部分建筑面│          │                              │ ││││ Configure volume increase in the proportion of 1 per thousand.
│          │                              │
├─────┼─────┼────┼───────────┼─────┼───────────────┤
│          │          │        │                      │四班以上  │按照《城市居住区规划设计规    │
│          │          │        │                      │(含四班)│范》、设置,千人指标12-15人/ │
│││││ Kindergarten and │ thousand; class 25-30; service RADIUS │
│││ Meters/│ kindergarten │ 9-12 │ established when independent more than 500 m; live Solstice sunlight │
│││││ Reset │ not less than 3 hours 1/2 venues in standard │            │          │          │        │                      │积15-20平 │建筑日照阴影线外。
│    │          │          │        │                      │方米。
│                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │        │                      │生均面积  │按照《城市居住区规划设计规    │
│          │          │        │                      │18-20平方 │范》、《中小学布局规划》设置,│
│││ Square meters/│ elementary │ 6-8 meters/person (old │ thousand targets 70 per thousand; class 45; service │
│ │││││ City reconstruction should not be more than 500 m; teaching rooms winter │
│          │          │        │                      │15-18)   │至日日照不小于2小时;         │
│          │          ├────┼───────────┼─────┼───────────────┤
│ │││ Sports venues per capita more than 1.08 sq │ │ PE │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ Health posts │ │ │ 500 square meters 300 square meters in accordance with the planning and design of urban residential area code for │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │文化活动│                      │400-600平 │                              │
│││ (Youth │ 400-600 (youth │ square meters (youth │ in accordance with the planning and design of urban residential area planning │
│││ Years, older building 20-30 square meters/k │ │ activity year site │ fan, the Ministry of construction has built gauge (2004) 167th │
│          │          │活动中  │人)                  │40-60平方 │                              │
│          │          │心)    │                      │米/千人)│                              │
│          │          ├────┼───────────┼─────┼───────────────┤
Fitness │││ │││ residents in accordance with the planning and design of urban residential area code for │
│          │          │设施    │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ Communities, Office space of not less than 1000 │ │ │ communities in conjunction with the Office in downtown Guiyang community service │
│ 3000-5000 │ 10000 Office │-│ authority square meters, every 50 households enjoy │ │ layout of the neighborhood plan, set principles │
│ (Community) │ │ service │ 15000 property sets of 10 square meters, 50 │ │ households according to the arrangement on the 1 or 2 floor │
│          │          │        │50户计                │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│ │ │ 100-150 │││ post office square meters in accordance with the planning and design of urban residential area code for │
│          │          ├────┼───────────┼─────┼───────────────┤
Power │││ room │ │ │ 30-50 square meters in accordance with the planning and design of urban residential area code for │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ │ │ │ 20-40 square meters road lighting power distribution in accordance with the planning and design of urban residential area code for │
│          │          │室      │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ Farmers market │ │ services │ 8001000 square meters radius of 500-1000 meters │
│          │          ├────┼───────────┼─────┼───────────────┤
│ │ │ 30-60 │││ public toilet square meters in accordance with the planning and design of urban residential area code for │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ Fraternity House daycare center hits 50 │ │ │ 20 sqm/bed size bed/million, should be close to intensive green │
│          │          │        │                      │          │安排,可与老年活动中心合并设置│
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │        │总建筑面积不足10万平方│          │                              │
│          │          │        │米的,物业服务用房按照│          │                              │
│          │          │        │总建筑面积3‰的比例配 │          │                              │
│          │          │        │置,最低不得低于90平方│          │                              │
│          │          │        │米;总建筑面积在10万平│          │                              │ │││ Property services │ square meters above, property services │ │ Guizhou province, in accordance with the management regulations of │
│          │          │用房    │房的配置以300平方米为 │          │设置                          │
│          │          │        │起点,超过10万平方米的│          │                              │
│          │          │        │部分,按照超过部分建筑│          │                              │
│          │          │        │面积2‰的比例增加配   │          │                              │
│          │          │        │置,超过50万平方米的部│          │                              │
│          │          │        │分,按照超过部分建筑面│          │                              │ ││││ Configure volume increase in the proportion of 1 per thousand.
│          │                              │
├─────┼─────┼────┼───────────┼─────┼───────────────┤
│││││ 22-25 │ square in accordance with the planning and design of urban residential planning │
│││ Secondary school (Elementary │ │ meters/person (old │ fan, set the layout and planning, │
│││, High 8-10 meters/│ │ │ the urban reconstruction in thousands index 45/thousand; 50 people per class; service │
│││) │ │ 18-20) │ radius of not more than 1000 m; teaching rooms winter │
│          │          │        │                      │          │至日日照不小于2小时;         │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ Communities, Office space of not less than 1000 │ │ │ communities in conjunction with the Office in downtown Guiyang community service │
│││ Board Office │ square meters, every 50 households enjoy │ │ layout of the neighborhood plan, set principles │
│││ Service │ set of 10 square meters, 50 │ │ households according to the arrangement on the 1 or 2 floor │
│          │          │        │50户计                │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │门诊所  │                      │          │                              │
│││ (Community health │ 3000-5000 │ │ 2000-3000 square meters in accordance with the planning and design of urban residential area code for │
│          │          │生服务中│                      │平方米    │                              │
│          │          │心)    │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ Cultural events square meters/k │ 200-600 │ │ 100-200 in accordance with the planning and design of urban residential area code for │
│          │          │中心    │                      │方米/千人│                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│ │││ Sports venues per capita more than 1.08 sq │ │ PE │
│          │          │        │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │        │                      │          │按照《城市居住区规划设计规    │
│││ Farmers market square │ │ │ 1000-1200 fan of the layout plan and the farmers ' markets set up │
│          │          │        │                      │          │置,服务半径500-1200米        │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ Opening and closing │ │ │ 200-300 square meters by 500 square meters in accordance with the planning and design of urban residential area code for │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ Public toilet size │-│ 60-100 │ 30-60 square meters in accordance with the planning and design of urban residential area planning │
│  10000-  │          │        │                      │米        │范》,独立设置                │
│  16000   │  30000-  ├────┼───────────┼─────┼───────────────┤
│ (Residential area) │││ ¦ 50000 municipal institutions in accordance with the planning and design of urban residential area code for │
│          │          │管理所  │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ First │ │ │ 2000 square meters at the end of the bus in accordance with the planning and design of urban residential area code for │
│          │          │站      │                      │          │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │垃圾转运│                      │          │按照《城市居住区规划设 计规   │
│ │ │ │││ Station 800 square meters of the fan, with surrounding buildings span should not be small │
│          │          │        │                      │          │于8米                         │
│          │          ├────┼───────────┼─────┼───────────────┤
│ 700-1000 │ 600 square │ │││ police station in accordance with the planning and design of urban residential area code for │
│          │          ├────┼───────────┼─────┼───────────────┤
│││ Youth living square party m/k │ 40-60 │ 20-30 │ │
│          │          │动中心  │                      │米/千人  │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │养老、敬│10-15方米/千人       │20-30平方 │                              │
│          │          │老场所  │                      │米/千人  │                              │
│          │          ├────┼───────────┼─────┼───────────────┤
│          │          │        │总建筑面积不足10万平方│          │                              │
│          │          │        │米的,物业服务用房按照│          │                              │
│          │          │        │总建筑面积3‰的比例配 │          │                              │
│          │          │        │置,最低不得低于90平方│          │                              │
│          │          │        │米;总建筑面积在10万平│          │                              │
│││ Property services │ square meters above, property services │ │ Guizhou province, in accordance with the management regulations of │                        │││ Room with 300 square meters for │ │ │ configuration settings.

│          │          │        │起点,超过10万平方米的│          │                              │
│          │          │        │部分,按照超过部分建筑│          │                              │
│          │          │        │面积2‰的比例增加配   │          │                              │
│          │          │        │置,超过50万平方米的部│          │                              │
│          │          │        │分,按照超过部分建筑面│          │                              │ ││││ Configure volume increase in the proportion of 1 per thousand.
│          │                              │
├─────┴─────┴────┴───────────┴─────┴───────────────┤
│    说明:                                                                                          │
│ 1. construction project between the construction level when the size of the population except in accordance with the previous requirements outside the building, should also be increased according to the next level requires appropriate public construction │
│施;                                                                                                │
│ 2. public services set for the projects in line with the provisions of the code for planning design of urban residential area; │
│ 3. residential area in addition to construct community-level public construction, but should also be based on the residential community, organizing structure building when public buildings; │                              │ 4. except in residential construction community level with the public, and shall, in accordance with group structure was built, when the public.
│                                                │ 5. indicator sets limit values for facilities in this table, index of not less than the value.
│        │ 6. public facilities to meet the residence facilities should also be supporting according to regulatory requirements, more private living quarters with bus, junior high school and other public buildings.
│     │ 7. resident population is more than 50,000 people, should be fully demonstrated and urban water supply, drainage, transport, municipal facilities, supporting public construction at the city level.


└──────────────────────────────────────────────────┘

Schedule VII:
Parking index table
┌──┬──────────────┬────────────┬──────────┐
│ │ │ │ Ordinal building category index unit vehicle index │
├──┼──────────────┼────────────┼──────────┤
│ 1  │旅馆、宾馆                  │车位/客房              │         1          │
├──┼──────────────┼────────────┼──────────┤
│ │ │ Restaurants, entertainment 2 spaces per 100 square meters building area ¦ 2 ¦
├──┼──────────────┼────────────┼──────────┤
¦ 3 ¦ ¦ office spaces/100 square meters building area │ 0.7 │
├──┼──────────────┼────────────┼──────────┤
¦ 4 ¦ business ¦ spaces/100 square meters building area │ 0.7 │
├──┼──────────────┼────────────┼──────────┤
¦ ¦ 5 ¦ the gym spaces/100 sqm floor area ¦ 1 ¦
├──┼──────────────┼────────────┼──────────┤
¦ 6 ¦ theaters │ spaces/100 sqm floor area ¦ 1 ¦
├──┼──────────────┼────────────┼──────────┤
│ │ 7 │ hospital spaces/100 sqm floor area ¦ 1 ¦
├──┼──┬───────────┼────────────┼──────────┤
│ 8  │    │低层商品房住宅        │车位/户                │         2          │
├──┤    ├───────────┼────────────┼──────────┤
│ │ │ Multi-storey and 9 per cent/100 sqm floor space of commercial housing residential │ spaces ¦ 1 ¦
├──┤    ├───────────┼────────────┼──────────┤
│ 10 │ │ │ home │ spaces of affordable housing/household 0.5 │
├──┤住宅├───────────┼────────────┴──────────┤
│ │ │ 11 fetched houses residential │ executed in the high-rise housing and above residential │
├──┤    ├───────────┼────────────┬──────────┤
│ 12 │    │公租房                │车位/户                │        0.3         │
├──┤    ├───────────┼────────────┼──────────┤
│ │ │ 13 affordable housing (public parking) │ │ spaces/household 0.1 │
├──┼──┼───────────┼────────────┼──────────┤
│ │ │ │ 14 primary and secondary spaces/100 students and teachers │ 0.4 │
├──┤学校├───────────┼────────────┼──────────┤
│ │ │ │ 15 higher education spaces/100 students ¦ 2 ¦
├──┼──┴───────────┼────────────┼──────────┤
│ │ Railway station 16 per thousand passengers/peak day │ │ spaces 3.5 │
├──┼──────────────┼────────────┼──────────┤
¦ ¦ 17 ¦ farmers ' markets spaces/100 sqm floor area ¦ 2 ¦
├──┼──────────────┼────────────┼──────────┤
¦ 18 ¦ gallery │ spaces, museums, library/100 sqm floor area ¦ 1 ¦
├──┼───────┬──────┼────────────┼──────────┤
¦ 19 Park, square │ │ recreation spaces/100 sqm area of │ 0.2 │
├──┤类            ├──────┼────────────┼──────────┤
│ │ │ │ 20 natural landscape spaces/100 sqm area of │ 0.01 │
├──┼───────┴──────┼────────────┼──────────┤
│ │ │ Integrated logistics park 21 spaces per 100 square meters building area ¦ 1 ¦
├──┼───────┬──────┼────────────┼──────────┤
│ │ │ │ Factory, Office building 22 spaces/100 square meters building area │ 0.6 │
├──┤工业类        ├──────┼────────────┼──────────┤
│ │ │ │ 23 storage spaces/100 square meters building area │ 0.3 │
├──┴───────┴──────┴────────────┴──────────┤
│    备注:                                                                        │
│ 1. This table set the standard for buildings in Guiyang City parking garages, construction indicators are shown in the table should construct the building │
│停车位的最低指标;                                                                │
│ 2. allocation of other vehicles including motorcycles. bicycle. electric bikes and bike parking; │
│ 3. outdoor surface parking in General should not exceed the total number of berths 10%; │
│    4.本表车位以小汽车为标准单位;                                                │                        │ 5. indicators of other vehicles by the Department of town and country planning reference to relevant national standards.


└─────────────────────────────────────────┘

Schedule VIII:
City transmission line corridor width control table (unit: m)
┌──────┬──────┬──────┬──────┬─────────┐
│ │ Voltage level into four │ │ │ double circuit on same Tower wire protection zone │
├──────┼──────┼──────┼──────┼─────────┤
│   500KV    │     70     │     70     │     75     │        20        │
├──────┼──────┼──────┼──────┼─────────┤ │ 220KV │ 45 │ 45 │ 45-60 │ 15 │
├──────┼──────┼──────┼──────┼─────────┤
│ 110KV │ 30 │ 30 │ 30-50 │ 10 │

└──────┴──────┴──────┴──────┴─────────┘

Schedule IX:
Scope of protection for overhead lines distance table
┌───────┬─────────────────────────────┐
│   电压等级   │                       保护范围距离                       │
├───────┼─────────────────────────────┤
¦ 10KV 5 meters (since wires extending from the sidelines, with, depending on the environment in accordance with overhead) │
├───────┼─────────────────────────────┤
│ 35110KV │ 10-15 m (depending on the environment in accordance with overhead) │
├───────┼─────────────────────────────┤
│ │ 15-20 220KV m (depending on the environment in accordance with overhead) │
├───────┼─────────────────────────────┤
│    500KV     │                           20米                           │

└───────┴─────────────────────────────┘

Ten of the schedule:
Trees and other facilities the minimum horizontal distance from the control table
┌────────────┬──────────┬─────────────┐
│ │ Facility name from Arbor Center distance (m) │ from shrubs Center distance (m) │
├────────────┼──────────┼─────────────┤
│      低于2米的围墙     │         1.0        │                          │
├────────────┼──────────┼─────────────┤
│         挡土墙         │         1.0        │                          │
├────────────┼──────────┼─────────────┤
│        路灯杆柱        │         2.0        │                          │
├────────────┼──────────┼─────────────┤
│     电力、电信杆柱     │         1.5        │                          │
├────────────┼──────────┼─────────────┤
│         消防栓         │         1.5        │            2.0           │
├────────────┼──────────┼─────────────┤
│       测量水准点       │         2.0        │            2.0           │ └────────────┴──────────┴─────────────┘